1、Alarm systems Social alarm systems Part 1 : System requirements The European Standard EN 50134-1:2002 has the status ofa British Standard ICs 13.320 BS EN 50 134- 1 12002 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW BS EN 50134-112002 National foreword This British Standard
2、 is the official English language version of The UKparticipation in its preparation was entrusted by Technical Committee GW/l, Electronic security systems, to Subcommittee GW/1/12, Social alarms, which has the responsibility to: EN 50134-112002. - - aid enquirers to understand the text; present to t
3、he responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. - A list of organizations represented on this subcommittee can be o
4、btained on request to its secretary. Cross-references The British Standards which implement international or European publications referred to in this document may be found in the BSI Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Search”faci1it
5、y ofthe BSI Electronic Catalogue or ofBritish Stan dards Online. This publication does not purport to include all the necessary provisions of a contract. Users of this publication are responsible for their correct application. Compliance with a British Standard does not ofitself confer immunity from
6、 legal obligations. This British Standard. having - been prepared under the direction of the Consumer Products and Services Sector Summary of pages This document comprises a front cover, an inside front cover, the EN title page, Policyand Strategycommittee, was published under the authoritv of the S
7、tandards The BSI copyright date displayed in this document indicates when the pages 2 to 11 and a back cover. Policy and Strategy Committee on 3 July 2002 document was last issued. Amendments issued since publication Amd.No. I Date I Comments O BSI 3 July 2002 ISBN O 580 40015 8 EUROPEAN STANDARD EN
8、 50134-1 NORME EUROPENNE EUROPISCHE NORM June 2002 ICs 13.320 English version Alarm systems - Social alarm systems Part 1 : System requirements Systmes dalarme - Systmes dalarme sociale Partie 1 : Rgles relatives aux systmes Alarmanlagen - Personen-H ilferufan lagen Teil 1 : Systemanforderungen This
9、 European Standard was approved by CENELEC on 2002-06-01. CENELEC members are bound to comply with the CENKENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical refer
10、ences concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC m
11、ember into its own language and notified to the Central Secretariat has the same status as the oficial versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Luxembourg,
12、Malta, Netherlands, Norway, Portugal, Slovakia, Spain, Sweden, Switzerland and United Kingdom. CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B -
13、 1050 Brussels O 2002 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 50134-1:2002 E EN 50134-1 :2002 -2- Contents Page I n troduct ion 4 1 Scope . . 5 2 Normative references 5 . 5 3 4 System requirements 6 4.1 Local unit and cont
14、roller identification . 7 4.2 Alarm and fault identification 7 4.3 2-way speech communication facility . . 7 4.4 Use of personal receiver(s) . 7 4.5 Fault indication . 7 4.6 Calling the user 7 4.7 Logging alarm and fault conditions 7 4.8 System design . 4.9 Confirmation of alarm or fault reception .
15、 8 5 Environmental classes . 8 6 Document at i on . 8 Annex A (normative) Functional elements of a social alarm system . 9 Defi ni tions . . 8 Annex B (informative) Examples of different types of local unit and Fig ures Figure A.l - Functional elements of a social system . 9 Figure B.l - Local unit
16、and controller combined 10 controller configurations 10 Figure B 2 - Multiple local units connected to a single controller 11 -3- EN 50134-1 :2002 Foreword This European Standard was prepared by the Technical Committee CENELEC TC 79, Alarm systems. The text of the draft was submitted to the formal v
17、ote and was approved by CENELEC as EN 50134-1 on 2002-06-01. The following dates were fixed: - latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2003-06-01 - latest date by which the national standards conflic
18、ting with the EN have to be withdrawn (dow) 2005-06-01 Annexes designated “normative“ are part of the body of the standard. Annexes designated “informative“ are given for information only. In this standard, annex A is normative and annex B is informative. EN 50134-1 :2002 -4- Introduction A social a
19、larm system provides 24 hours facilities for alarm triggering, identification, signal transmission, alarm reception, logging and 2-way speech communication, to provide reassurance and assistance for people living at home and considered to be at risk. A social alarm system is comprised of a number of
20、 system parts which can be configured in different ways to provide this functionality. A user can request assistance by the use of a manually activated trigger device resulting in an alarm triggering signal. In certain cases, alarm triggering signals can be generated by automatic trigger devices. A
21、local unit or controller receives the alarm triggering signal, switching from the normal to the alarm condition and indicating this to the user (some systems use an optional pre-alarm condition that allows the user to reset the alarm for a short period of time). The controller normally transmits the
22、 alarm condition to an Alarm Receiving Centre (ARC) via the alarm transmission system. The ARC can either be local to the controller or remote from the controller. The ARC has the facility to identify the local unit, alarm type and to then establish two-way speech communication between the alarm rec
23、ipient and the user. The alarm recipient provides reassurance to the user and directs assistance where appropriate. In some cases, the alarm may be diverted to an alarm recipient using a personal receiver. In this case, the alarm is identified to the alarm recipient and a two-way speech communicatio
24、n path established to the user and receipt of the alarm acknowledged to the controller. In all cases, the system records the time, date, location and type of alarm. The system is designed to detect and report fault conditions affecting the transmission of alarms. In some cases, temporary disconnecti
25、on of a local unit is possible to minimise faults or prevent alarms triggered inadvertently affecting the correct operation of the system. -5- EN 50134-1 :2002 1 Scope This standard specifies the minimum requirements for a social alarm system. For people with disabilities (e.g. visual and hearing im
26、pairment), additional requirements not covered in this series of standards may apply. 2 Normative references This European Standard incorporates, by dated or undated reference, provisions from other publications. These normative references are cited at appropriate places in the text and the publicat
27、ions are listed hereafter. For dated references, subsequent amendments to or revisions of any of these publications apply to this European Standard only when incorporated in it by amendment or revision. For undated references, the latest edition of the publication referred to applies. EN 50134-2 199
28、9 Alarm sysfems - Social alarm sysfems Par 2: Trigger devices EN 50134-3 2001 Alarm sysfems - Social alarm sysfems Par 3: Local unif and confroller EN 50134-5 Alarm sysfems - Social alarms sysfems Par 5: Inferconnecfions and communicafions EN 50134-7 1996 Alarm sysfems - Social alarm sysfems Par 7:
29、Applicafion guidelines ISOAEC Guide 37 1995 Insfrucfions for use of producfs of consumer inferesf 3 Definitions For the purpose of this standard, the following definitions apply: 3.1 social alarm system system providing 24 hour facilities for alarm triggering, identification, signal transmission, al
30、arm reception, 2-way speech communication, reassurance and assistance, for use by persons who can be considered to be living at home at risk 3.2 alarm receiving centre (ARC) system part which provides facilities for communication with a number of controllers and providing the alarm receiving and inf
31、ormation processing system as an interface to the alarm recipient 3.3 controller interface between one or more local units and the alarm transmission system or alarm recipient 3.4 local unit interface between the user and the controller which enables 2-way speech At draft stage EN 50134-1 :2002 -6-
32、3.5 trigger device system part, operated by a human or automatically, that communicates to the local unit and controller, initiating the alarm triggering signal 3.6 personal receiver system part which provides 2-way speech communication and facilities for identifying and acknowledging the alarm 3.7
33、alarm transmission system transmission system that provides communication between the controller and the alarm receiving centre or an alarm recipient 3.8 pre-al arm condition condition following the reception of an alarm triggering signal 3.9 alarm condition condition following the pre-alarm conditi
34、on 3.10 normal condition condition during which the system is fully operational and is not in any other condition 3.1 1 fault condition condition following detection of a fault by the local unit and controller that prevents the functioning of the system 3.12 fau I t i nd cat ion indication of a faul
35、t condition 3.13 alarm triggering signal signal transmitted by a trigger device to indicate an alarm 3.14 alarm recipient person who receives and acts upon an alarm signal 4 System requirements As a minimum, a social alarm system shall consist of the following system parts: - manually activated trig
36、ger device; - local unit; - controller; - alarm transmission system; -ARC. -7- EN 50134-1 :2002 All system parts shall comply with the relevant part of the EN 50134 series. Additional equipment shall not prohibit the correct functioning of the social alarm system. Please refer to Annex A (normative)
37、 and Annex B (informative). 4.1 Local unit and controller identification The system shall be capable of identifying the local unit and the controller which is in the alarm or fault condition. 4.2 Alarm and fault identification The system shall identify the different types of alarms and faults. 4.3 2
38、-way speech communication facility a) A social alarm system shall be equipped with a 2-way speech communication facility to allow verbal contact between alarm recipient and the user. b) 2-way speech communication between the alarm recipient and the user shall be provided following the receipt of an
39、alarm from a manually activated trigger device. c) In a system where the direction of the speech communication is manually switched, the direction shall be controlled by the alarm recipient. 4.4 Use of personal receiver(s) In the case of a personal receiver(s) being used to receive alarm and fault s
40、ignals, the system shall be configured so that, in the case of no response from the personal receiver(s), the alarm and fault signals shall be automatically transmitted to an ARC. 4.5 Fault indication The system shall have the facility to indicate faults affecting the transmission of alarms and faul
41、ts. 4.6 Calling the user If the facility exists to call the user in a non-alarm situation, then a) the call shall be preceded by an audible signal, b) the system shall have a privacy function to allow the user to prevent listening in and this function shall be overridden in an alarm condition, c) if
42、 the privacy function is active, the user shall have to take a positive action before a 2-way speech communication can be established. 4.7 Logging alarm and fault conditions The system shall log alarms and faults by recording the following: - date and time of alarm or fault; - identity of the local
43、unit and controller; - type of alarm or fault condition. EN 50134-1 :2002 -8- 4.8 System design a) The design of the system shall prevent any single local unit and controller prohibiting the functioning of other local units and controllers. b) The design of the system shall incorporate a back-up ARC
44、. 4.9 Confirmation of alarm or fault reception The system shall confirm to the controller the reception of an alarm or fault signal. Environ mental classes There are 4 environmental classes which apply to system parts: Class Environment I II Indoor in general III Indoor but restricted to a residenti
45、al environment Outdoor but sheltered from direct rain and sunshine or indoor with extreme environmental conditions IV Outdoor in general Classes I, II, III and IV are progressively more severe and therefore, class IV equipment may be used in class III applications etc. NOTE The order of the environm
46、ental classes is not representative of radio transmission performance System parts with the appropriate environmental class shall be selected to ensure correct operation in their service environment. Docu ment at i on Documentation relating to the system and system design shall be concise, complete
47、and unambiguous and shall include as a minimum the following: - name of manufacturer or supplier; - description of equipment; - environmental class. The documentation provided shall be sufficient to install, commission, and maintain the system. Instructions relating to the operation of the system sh
48、all be provided and shall be in accordance with ISOAEC Guide 37. -9- Annex A (normative) EN 50134-1 :2002 Functional elements of a social alarm system . . 1 Assistance provided when appropriate 1 Trigger device I Local unit t Controller Alarm transmission system t Alarm Receiving Centre . . I Social
49、 alarm system (minimum configuration) / Personal receiver (optional) Alarm recipient Figure A.l - Functional elements of a social system EN 50134-1 :2002 -10- Annex B (informative) Examples of different types of local unit and controller configurations Trigger device / Local unit & Trigger device Local unit & transmission I I I Trigger device Personal receiver (optional) -* 4-b = communication path Figure B.l - Local unit and controller combined - 11 - EN 50134-1 :2002 Trigger device Trigger device ! ! ! i Personal receiver (optional) - = communication path Figure B.2