1、BRITISH STANDARDBS EN 50377-10-2: 2005Connectors sets and interconnect components to be used in optical fibre communication systems Product specifications Part 10-2: MU/APC singlemode terminated on IEC 60793-2 category B1 fibreThe European Standard EN 50377-10-2:2005 has the status of a British Stan
2、dardICS 33.180.20g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58BS EN 50377-10-2:2005This British Standard was published under the authority of the
3、 Standards Policy and Strategy Committee on 28 April 2006 BSI 2006ISBN 0 580 46238 2National forewordThis British Standard is the official English language version of EN 50377-10-2:2005.The UK participation in its preparation was entrusted by Technical Committee GEL/86, Fibre optics, to Subcommittee
4、 GEL/86/2, Fibre optic interconnecting devices and passive components, which has the responsibility to:A list of organizations represented on this subcommittee can be obtained on request to its secretary.Cross-referencesThe British Standards which implement international or European publications ref
5、erred to in this document may be found in the BSI Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online.This publication does not purport to include all the necessary provi
6、sions of a contract. Users are responsible for its correct application.Compliance with a British Standard does not of itself confer immunity from legal obligations. aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpretation,
7、or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK.Summary of pagesThis document comprises a front cover, an inside front cover, the EN title page, pages 2 to 32, an inside back cover and a back cover.The
8、 BSI copyright notice displayed in this document indicates when the document was last issued.Amendments issued since publicationAmd. No. Date CommentsEUROPEAN STANDARD EN 50377-10-2NORME EUROPENNE EUROPISCHE NORM May 2005 CENELECEuropean Committee for Electrotechnical Standardization Comit Europen d
9、e Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels ICS 33.180.20 English version Connectors sets and interconnect componentsto be used in optical fibre communication systems Product specifications Part 10-2: MU
10、-APC singlemode terminated on IEC 60793-2category B1 fibre Jeux de connecteurs et composants dinterconnexion utiliser dansles systmes de communicationpar fibres optiques Spcifications de produit Partie 10-2: Type MU-APC cablsur une fibre unimodale de la catgorie B1 de la CEI 60793-2 Steckverbinderst
11、ze und Verbindungs-bauelemente fr Lichtwellenleiter-Datenbertragungssysteme ProduktnormenTeil 10-2: Bauart MU-APC zum Anschluss an Einmodenfasern der Kategorie B1.1 nach IEC 60793-50 This European Standard was approved by CENELEC on 2004-12-01. CENELEC members are bound to comply with the CEN/CENELE
12、C Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENE
13、LEC member. This European Standard exists in three official versions (English, French, German). A version in any otherlanguage made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions.
14、CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, CzechRepublic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Swede
15、n,Switzerland and United Kingdom. 2005 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 50377-10-2:2005 E EN 50377-10-2:2005 - 2 - ForewordThis European Standard was prepared by the Technical Committee CENELEC TC 86BXA, Fibre optic
16、 interconnect, passive and connectorised components. The text of the project was submitted to the Unique Acceptance Procedure and was approved by CENELEC on 2004-12-01.The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical n
17、ational standard or by endorsement (dop) 2005-12-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2007-12-01_- 3 - EN 50377-10-2:2005PRODUCT SPECIFICATION FOR CONNECTOR SET TO BE USED IN SINGLE MODE OPTICAL FIBRE COMMUNICATION SYSTEMS Type: MU-APC sin
18、glemode terminated on IEC 60793-2 category B1 fibreDescription PerformanceCoupling mechanism:Configuration:Fibre category: Cable typepush-pullplug/adaptor/plugIEC 60793-2-50 type B1see Table 3 Application:Attenuation Grades:(Random Mate)Return Loss: For use in EN Category U and ES 200-671 environmen
19、ts (see 1.3) P: 97% of measurementsQ: 99% of measurementsV: 55 dB unmatedRelated documents:IEC 61754-6 Fibre optic connector interfaces - Part 6: Type MU connector familyEN 61300-series Fibre optic interconnecting devices and passive components Basic test and measurement procedures IEC 60794-2 Optic
20、al Fibre Cables - Part 2: Indoor cables Sectional specificationIEC 61753-1-1 Fibre optic interconnecting devices and passive components performance standard Part 1-1: General and guidance - Interconnecting devices (connectors)EN 186000 Generic Specification connector sets for optical fibres and cabl
21、esES 200 671 Transmission and Multiplexing (TM) Passive optical components Optical fibre connectors for single-mode optical fibre communication systems Commonrequirements and conformance testingEN 300 019-series Equipment Engineering (EE) Environmental conditions and environmental tests for telecomm
22、unications equipmentIEC 60793-2 -50 Optical Fibre Cables - Part 2-50: Product SpecificationsOutline and maximum dimensions:78534166EN 50377-10-2:2005 - 4 - Contents1 Scope . 6 1.1 Product definition . 6 1.2 Intermateability . 6 1.3 Operating environment . 6 1.4 Reliability 6 1.5 Quality assurance 6
23、2 Normative references. 7 3 Description. 8 3.1 Plug . 8 3.2 Adaptor . 8 3.3 Materials . 8 3.4 Dimensions . 8 3.5 Colour and marking 8 4 Variants 9 4.1 Terminated plug 9 4.2 Adaptor . 9 4.2.1 Identification of variants. 9 5 Dimensional requirements . 10 5.1 Outline dimensions . 10 5.1.1 Plug variants
24、 10 5.1.2 Adaptor variants 11 5.2 Mating face and other limit dimensions 135.2.1 Plug . 13 5.2.2 Ferrule endface geometry after termination 15 5.2.3 Positioning of fibre core centre . 16 5.2.4 Control of fibre axis 17 5.2.5 Adaptor 18 5.2.6 Pin gauge for adaptor 206 Tests. 21 6.1 Sample size . 21 6.
25、2 Test and measurement methods 21 6.3 Test sequence 21 6.4 Pass/fail criteria. 21 7 Test report 21 8 Testing requirements . 22 8.1 Dimensional and marking requirements . 22 8.2 Optical performance requirements 22 8.3 Mechanical performance requirements. 248.4 Environmental performance requirements 2
26、8 Annex A (normative) Reference connector details. 31 Annex B (normative) Sample size and product sourcing requirements 32 Figures Figure 1 - Outline dimensions Plug .10 Figure 2 Outline dimensions Adaptor.12 Figure 3 - Plug mating face and other limit dimensions .13 Figure 4 - Ferrule endface geome
27、try after termination .15 Figure 5 - Positioning of fibre core to ferrule centre and connector key 16Figure 6 - Allowable angle of fibre axis versus position of fibre core .17Figure 7 - Mating face and other limit dimensions Adaptor18 Figure 8 - Pin gauge for adaptor .20 TablesTable 1 - Ensured leve
28、l of random attenuation . 6 Table 2 - Preferred colour scheme 8 Table 3 - Plug variants 9 - 5 - EN 50377-10-2:2005Table 4 - Adaptor variants 9 Table 5 - Grade P plug variants 9 Table 6 - Grade Q plug variants 9 Table 7 - Adaptor variants 9 Table 8 - Optical performance requirements 22 Table 9 - Mech
29、anical performance requirements 24 Table 10 - Environmental performance requirements. 28 EN 50377-10-2:2005 - 6 - 1 Scope 1.1 Product definition This European Standard contains the initial, start of life dimensional, optical, mechanical and environmental performance requirements which a terminated a
30、nd assembled singlemode resilient alignment sleeve MU-APC simplex connector set (plug adaptor plug) must meet in order for it to be categorised as an EN standard product. Since different variants and grades of performance are permitted, product marking details are given in Section 3.5. 1.2 Intermate
31、ability Although all products conforming to the requirements of this specification will intermate, the resulting level of random attenuation performance will only be ensured in accordance with Table 1. The intention is that this will be true irrespective of the manufacturing source(s) of the product
32、. In all cases, the intermating of plug variants having different attenuation or return loss grades will result in an uncertain level of random attenuation performance. When intermating plug variants having different return loss grades, the resulting level of return loss can not be assured to be any
33、 better than the worst return loss grade Similarly, the intermating of a grade P plug with a grade Q plug will result in an uncertain level of random attenuation performance. Table 1 - Ensured level of random attenuation Plug variant/Attenuation grade P QPPPQP1.3 Operating environment The tests sele
34、cted combined with the severities and durations are representative of an IEC Category U environment and the ES 200 671 environment. 1.4 Reliability Whilst the anticipated service life expectancy of the product in this environment is 20 years, compliance with this specification does not guarantee the
35、 reliability of the product. This should be predicted using a recognised reliability assessment programme. 1.5 Quality assurance Compliance with this specification does not guarantee the manufacturing consistency of the product. This should be maintained using a recognised quality assurance programm
36、e. - 7 - EN 50377-10-2:20052 Normative references IEC 61754-6 Fibre optic connector interfaces dimensions - Part 6: Type MU connector family EN 61300 series Fibre optic interconnecting devices and passive components - Basic test and measurement procedures (IEC 61300 series) EN 61300-2-1 Part 2-1: Te
37、sts - Vibration (sinusoidal) (IEC 61300-2-1) EN 61300-2-2 Part 2-2: Tests - Mating durability (IEC 61300-2-2) EN 61300-2-4 Part 2-4: Tests - Fibre/cable retention (IEC 61300-2-4) EN 61300-2-5 Part 2-5: Tests Torsion/twist (IEC 61300-2-5) EN 61300-2-6 Part 2-6: Tests - Tensile strength of coupling me
38、chanism (IEC 61300-2-6) EN 61300-2-7 Part 2-7: Tests Bending moment (IEC 61300-2-7) EN 61300-2-12 Part 2-12: Tests Impact (IEC 61300-2-12) EN 61300-2-17 Part 2-17: Tests Cold (IEC 61300-2-17) EN 61300-2-18 Part 2-18: Tests - Dry heat - High temperature endurance (IEC 61300-2-18) EN 61300-2-19 Part 2
39、-19: Tests - Damp heat (steady state) (IEC 61300-2-19) EN 61300-2-21 Part 2-21: Tests Composite temperature-humidity cyclic test (IEC 61300-2-21) EN 61300-2-22 Part 2-22: Tests - Change of temperature (IEC 61300-2-22) EN 61300-2-26 Part 2-26: Tests salt mist (IEC 61300-2-26) EN 61300-2-27 Part 2-27:
40、 Tests Dust Laminar flow (IEC 61300-2-27) EN 61300-2-42 Part 2-42: Tests - Static side load for connectors (IEC 61300-2-42) EN 61300-2-46 Part 2-46 Test Dampheat Cyclic EN 61300-3-3 Part 3-3: Examinations and measurements - Monitoring change in attenuation and in return loss (multiple paths) (IEC 61
41、300-3-3) EN 61300-3-4 Part 3-4: Examinations and measurements Attenuation (IEC 61300-3-4) EN 61300-3-6 Part 3-6: Examinations and measurements - Return loss (IEC 61300-3-6) EN 61300-3-23 Part 3-23: Examination and measurements - Fibre position relative to ferrule endface (IEC 61300-3-23) EN 61300-3-
42、28 Part 3-28: Examination and measurements - Transient loss (IEC 61300-3-28) EN 61300-3-34 Part 3-34: Examinations and measurements - Attenuation of random mated connectors (IEC 61300-3-34) EN 61753-1-1 Fibre optic interconnecting devices and passive components performance standard - Part 1-1: Gener
43、al and guidance - Interconnecting devices (connectors) (IEC 61753-1-1) EN 186000-1 Generic Specification: Connector sets for optical fibres and cables Part 1: Requirements, test methods and qualification approval procedures EN 300 019-series Equipment Engineering (EE) Environmental conditions and en
44、vironmental tests for telecommunications equipment ES 200 671 Transmission and Multiplexing (TM) Passive optical components Optical fibre connectors for single-mode optical fibre communication systems Common requirements and conformance testing IEC 60793-2-50 Optical fibres - Part 2-50: Product spec
45、ifications Sectional specification for class B single-mode fibres IEC 60794-2 Optical fibre cables - Part 2: Indoor cables - Sectional specification EN 50377-10-2:2005 - 8 - 3 Description The MU-APC connector is a single position plug connector set of plug adaptor plug configuration characterised by
46、 a cylindrical, spring loaded butting ferrule of 1,25 mm nominal diameter and a push-pull coupling mechanism. The optical alignment mechanism of the connectors is of a resilient sleeve style. 3.1 Plug The plug features a cylindrical zirconia ferrule and a push-pull mechanism. It has a single male ke
47、y which is used to limit and may be used to orientate, the relative rotation between mated connectors. A cover (dustcap) to protect the ferrule endface when the connector is in the unmated condition shall be provided. Alternative materials may be used for the ferrule that have directly compatible ma
48、terial properties to the specified materials but the endface and performance requirements must be met under all conditions 3.2 Adaptor The adaptor has a zirconia ceramic resilient alignment sleeve. The mounting styles are duplex rectangular flange with snap-latches with a panel cut out as SC connect
49、or and simplex rectangular flange with snap-latches. Covers (dustcaps) shall be provided to protect each port of the adaptor. Alternative material may be used for the sleeve that have directly compatible material properties to zirconia but the performance requirements must be met under all conditions 3.3 Materials Materials which are not specified or which are not specifically described are left to the discretion of the manufacturer.3.4 Dimensions Outline dimensions and other dimensions necess