1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationBS EN 50377-13-3:2011Connector sets and interconnect components to be used in optical fibre communication systems Product specificationsPart 13-3: Type LX.5-APC DUPLEX terminated
2、 on IEC 60793-2-50 category B1.1 and B1.3 singlemode fibre, with full zirconia ferrule category UBS EN 50377-13-3:2011 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN50377-13-3:2011.The UK participation in its preparation was entrusted to TechnicalCommittee GEL/
3、86/2, Fibre optic interconnecting devices and passivecomponents.A list of organizations represented on this committee can beobtained on request to its secretary.This publication does not purport to include all the necessaryprovisions of a contract. Users are responsible for its correctapplication. B
4、SI 2011ISBN 978 0 580 64518 1ICS 33.180.20Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of theStandards Policy and Strategy Committee on 30 April 2011.Amendments issued since publicationDate Text affectedBS EN
5、50377-13-3:2011EUROPEAN STANDARD EN 50377-13-3 NORME EUROPENNE EUROPISCHE NORM March 2011 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Management Centre: Avenue Marnix 17, B - 1000 Bru
6、ssels 2011 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 50377-13-3:2011 E ICS 33.180.20 English version Connector sets and interconnect components to be used in optical fibre communication systems - Product specifications - Par
7、t 13-3: Type LX.5-APC DUPLEX terminated on IEC 60793-2-50 category B1.1 and B1.3 singlemode fibre, with full zirconia ferrule category U Jeux de connecteurs et composants dinterconnexion utiliser dans les systmes de communication par fibres optiques - Spcifications de produits - Partie 13-3: Type LX
8、.5-APC duplex raccord sur des fibres unimodales de catgorie B1.1 et B1.3 de la CEI 60793-2-50, avec frule en zircone plein de catgorie U Steckverbinderstze und Verbindungsbauelemente fr Lichtwellenleiter-Datenbertragungssysteme - Produktnormen - Teil 13-3: Bauart LX.5-APC-Duplex zum Anschluss an Ein
9、modenfasern der Kategorien B1.1 und B1.3 nach IEC 60793-2-50 mit Zirkonium-Ferrule fr die Kategorie U This European Standard was approved by CENELEC on 2011-01-02. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European St
10、andard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, F
11、rench, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgiu
12、m, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. BS
13、EN 50377-13-3:2011EN 50377-13-3:2011 2 Foreword This European Standard was prepared by the Technical Committee CENELEC TC 86BXA, Fibre optic interconnect, passive and connectorised components. The text of the draft was submitted to the formal vote and was approved by CENELEC as EN 50377-13-3 on 2011
14、-01-02. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and CENELEC shall not be held responsible for identifying any or all such patent rights. The following dates were fixed: latest date by which the EN has to be implemented
15、 at national level by publication of an identical national standard or by endorsement (dop) 2012-01-02 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2014-01-02 _ BS EN 50377-13-3:2011 3 EN 50377-13-3:2011 Connector sets and interconnect components to
16、be used in optical fibre communication systems Product specifications Part 13-3: Type LX.5-APC DUPLEX terminated on IEC 60793-2-50 category B1.1 and B1.3 singlemode fibre, with full zirconia ferrule category U Description Performance Coupling mechanism: Latched push-pull Application: For use in EN c
17、ategory U (Uncontrolled environment) Configuration: Plug/adaptor/plug Attenuation grades: (random mate) B: 0,12 dB mean 0,25 dB for 97 % of measurements C: 0,25 dB mean 0,50 dB for 97 % of measurements Fibre category: EN 60793-2-50, Types B1.1 and B1.3 Cable type: see Table 3 Return loss grades: 1:
18、60 dB mated 55 dB unmated Related documents: EN 60794-2, Optical fibre cables Part 2: Indoor cables Sectional specification (IEC 60794-2) EN 61300 series, Fibre optic interconnecting devices and passive components Basic test and measurement procedures (IEC 61300 series) EN 61753-1, Fibre optic inter
19、connecting devices and passive components performance standard Part 1: General and guidance for performance standards (IEC 61753-1) EN 61754-23, Fibre optic connector interfaces Part 23: Type LX.5 connector family (IEC 61754-23) EN 61755-1, Fibre optic connector optical interfaces Part 1: Optical in
20、terfaces for single mode non-dispersion shifted fibres General and guidance (IEC 61755-1) EN 61755-3-2, Fibre optic connector optical interfaces Part 3-2: Optical interface, 2,5 mm and 1,25 mm diameter cylindrical full zirconia ferrules for 8 degrees angled-PC single mode fibres (IEC 61755-3-2) ETSI
21、 TS 100 671, Transmission and Multiplexing (TM); Passive optical components; Optical fibre connectors for single mode optical fibre communication systems; Common requirements and conformance testing Outline and maximum dimensions: R30 min. R30 min. 0,9 1,7 60 REF. 66 REF. BS EN 50377-13-3:2011EN 503
22、77-13-3:2011 4 Contents 1 Scope . 61.1 Product definition . 61.2 Intermateability 61.3 Operating environment . 61.4 Reliability . 61.5 Quality assurance 62 Normative references 73 Description 83.1 General 83.2 Plug . 83.3 Duplex adaptor . 83.4 Materials 83.5 Dimensions 83.6 Colour and marking 84 Var
23、iants 94.1 Terminated plug . 94.2 Adaptor 105 Dimensional requirements . 105.1 Outline dimensions . 105.2 Mating face and other limit dimensions . 136 Tests. 246.1 Sample size . 246.2 Test and measurement methods 256.3 Test sequence . 256.4 Pass/Fail criteria 257 Test report 258 Performance requirem
24、ents 258.1 Dimensional and marking requirements 258.2 Optical performance requirements 268.3 Mechanical performance requirements . 288.4 Environmental performance requirements . 33Annex A (informative) Attenuation against reference . 35Annex B (normative) Adaptor matched reference plug details 36Ann
25、ex C (normative) Sample size and product sourcing requirements . 37Annex D (informative) Zirconia ferrule response surface . 38Bibliography . 39BS EN 50377-13-3:2011 5 EN 50377-13-3:2011 Figures Figure 1 Outline dimensions Plug . 11Figure 2 Outline dimensions Duplex adaptor 12Figure 3 Mating face an
26、d other limit dimensions of plug connector interface 13Figure 4 Ferrule end face geometry After termination . 17Figure 5 Positioning of fibre core . 18Figure 6 Ferrule end face geometry Allowable undercut 19Figure 7 Requirements for the attenuation grades for the plug fibre core connected to the ide
27、al reference . 20Figure 8 Adaptor mating face and other limit dimensions . 21Figure 9 Pin gauge for adaptor 24Figure D.1 Radius vs. undercut and apex offset 38Tables Table 1 Ensured level of random attenuation . 6Table 2 Preferred colour scheme 9Table 3 Plug variants 9Table 4 Adaptor variants . 10Ta
28、ble 5 Geometrical parameters . 18Table 6 Optical performance requirements 26Table 7 Mechanical performance requirements . 28Table 8 Environmental performance requirements . 33Table 8 Environmental performance requirements . 34Table A.1 . 35Table A.2 Reference connector details 35Table B.1 . 36Table
29、C.1 37BS EN 50377-13-3:2011EN 50377-13-3:2011 6 1 Scope 1.1 Product definition This European Standard contains the initial, start of life dimensional, optical, mechanical and environmental performance requirements which a terminated and assembled singlemode resilient alignment sleeve LX.5 APC connec
30、tor set (plug/ adaptor/ plug) should meet in order for it to be categorised as an EN standard product. Since different variants and grades of performance are permitted, product marking details are given in 3.6. 1.2 Intermateability Although all products conforming to the requirements of this Europea
31、n Standard will intermate, the resulting level of random attenuation performance will only be ensured in accordance with Table 1. The intention is that this will be true irrespective of the manufacturing source(s) of the product. When intermating plug variants having different attenuation grades, th
32、e resulting level of attenuation cannot be assured to be any better than the worst attenuation grade. The intermating of a grade C plug with a grade B plug will result in an uncertain level of random attenuation performance. Table 1 Ensured level of random attenuation Plug attenuation grade C B C C
33、C B C B 1.3 Operating environment The tests selected combined with the severities and durations are representative of a category U environment described in EN 61753-1. 1.4 Reliability Whilst the anticipated service life expectancy of the product in this environment is 20 years, compliance with this
34、specification does not guarantee the reliability of the product. This should be predicted using a recognised reliability assessment programme. 1.5 Quality assurance Compliance with this specification does not guarantee the manufacturing consistency of the product. This should be maintained using a r
35、ecognised quality assurance programme. BS EN 50377-13-3:2011 7 EN 50377-13-3:2011 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the
36、referenced document (including any amendments) applies. EN 60793-2-50 Optical fibres Part 2-50: Product specifications Sectional specification for class B single-mode fibres (IEC 60793-2-50) EN 61300 (series) Fibre optic interconnecting devices and passive components Basic test and measurement proce
37、dures (IEC 61300 series) EN 61300-2-1 Part 2-1: Tests Vibration (sinusoidal) (IEC 61300-2-1) EN 61300-2-2 Part 2-2: Tests Mating durability (IEC 61300-2-2) EN 61300-2-4 Part 2-4: Tests Fibre/cable retention (IEC 61300-2-4) EN 61300-2-5 Part 2-5: Tests Torsion/twist (IEC 61300-2-5) EN 61300-2-6 Part
38、2-6: Tests Tensile strength of coupling mechanism (IEC 61300-2-6) EN 61300-2-7 Part 2-7: Tests Bending moment (IEC 61300-2-7) EN 61300-2-12:2009 Part 2-12: Tests Impact (IEC 61300-2-12:2009) EN 61300-2-17 Part 2-17: Tests Cold (IEC 61300-2-17) EN 61300-2-18 Part 2-18: Tests Dry heat High temperature
39、 endurance (IEC 61300-2-18) EN 61300-2-22 Part 2-22: Tests Change of temperature (IEC 61300-2-22) EN 61300-2-26 Part 2-26: Tests Salt mist (IEC 61300-2-26) EN 61300-2-27 Part 2-27: Tests Dust Laminar flow (IEC 61300-2-27) EN 61300-2-42 Part 2-42: Tests Static side load for connectors (IEC 61300-2-42
40、) EN 61300-2-44 Part 2-44: Tests Flexing of the strain relief of fibre optic devices (IEC 61300-2-44) EN 61300-2-46 Part 2-46: Tests Damp heat cyclic (IEC 61300-2-46) EN 61300-3-6:2009 Part 3-6: Examinations and measurements Return loss (IEC 61300-3-6:2008) EN 61300-3-10 Part 3-10: Examinations and
41、measurements Gauge retention force (IEC 61300-3-10) EN 61300-3-15 Part 3-15: Examinations and measurements Dome eccentricity of a convex polished ferrule endface (IEC 61300-3-15) EN 61300-3-16 Part 3-16: Examinations and measurements Endface radius of spherically polished ferrules (IEC 61300-3-16) E
42、N 61300-3-23 Part 3-23: Examination and measurements Fibre position relative to ferrule endface (IEC 61300-3-23) EN 61300-3-28 Part 3-28: Examinations and measurements Transient loss (IEC 61300-3-28) EN 61300-3-34 Part 3-34: Examinations and measurements - Attenuation of random mated connectors (IEC
43、 61300-3-34) EN 61300-3-42 Part 3-42: Examinations and measurements - Attenuation of single mode alignment sleeves and or adaptors with resilient alignment sleeves (IEC 61300-3-42) EN 61753-1 Fibre optic interconnecting devices and passive components performance standard Part 1: General and guidance
44、 for performance standards (IEC 61753-1) EN 61754-23 Fibre optic connector interfaces Part 23: Type LX.5 connector family (IEC 61754-23) ISO 8015 Technical drawings Fundamental tolerancing principle BS EN 50377-13-3:2011EN 50377-13-3:2011 8 3 Description 3.1 General The LX.5 APC connector is a singl
45、e position plug connector set of plug/ adaptor/ plug configuration characterised by cylindrical, spring loaded butting ferrules of 1,25 mm nominal diameter and a latched push-pull coupling mechanism. The optical alignment mechanism of the connectors is of a resilient sleeve style. 3.2 Plug The plug
46、features a cylindrical zirconia ceramic ferrule and a latched push-pull mechanism. It has a single male key which is used to limit and may be used to orientate, the relative rotation between mated connectors. A cover (dustcap) to protect the ferrule endface is integrated in the connector. 3.3 Duplex
47、 adaptor The adaptor has a zirconia ceramic resilient alignment sleeve. Alternative materials may be used for the sleeve that have directly compatible material properties with zirconia, but the endface and performance requirements shall be met under all conditions. The mounting style can be: a) squa
48、re flange - 2 hole fixing; b) square flange - clip fixing. Covers (dustcaps) are integrated in each port of the adaptor. 3.4 Materials Materials which are not specified or which are not specifically described are left to the discretion of the manufacturer. 3.5 Dimensions Outline dimensions and other dimensions necessary to ensure intermateability or which affect performance are specified. All other dimensions are left to the discretion of the manufacturer. Where the mating face limit dimensions are not in
copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1