1、BRITISH STANDARD BS EN 60115-9:2004 Fixed resistors for use in electronic equipment Part 9: Sectional specification Fixed surface mount resistor networks with individually measurable resistors The European Standard EN 60115-9:2004 has the status of a British Standard ICS 31.040.10 BS EN 60115-9:2004
2、 This British Standard was published under the authority of the Standards Policy and Strategy Committee on 19 March 2004 BSI 19 March 2004 ISBN 0 580 43576 8 National foreword This British Standard is the official English language version of EN 60115-9:2004. It is identical with IEC 60115-9:2003. Th
3、e UK participation in its preparation was entrusted to Technical Committee EPL/40X, Capacitors and resistors for electronic equipment, which has the responsibility to: A list of organizations represented on this committee can be obtained on request to its secretary. Cross-references The British Stan
4、dards which implement international or European publications referred to in this document may be found in the BSI Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online. Thi
5、s publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. aid enquirers to understand the text; present to the responsible inte
6、rnational/European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. Summary of pages This document comprises a front cover, an inside front cover, the EN
7、title page, pages 2 to 16, an inside back cover and a back cover. The BSI copyright notice displayed in this document indicates when the document was last issued. Amendments issued since publication Amd. No. Date CommentsEUROPEAN STANDARD EN 60115-9 NORME EUROPENNE EUROPISCHE NORM February 2004 CENE
8、LEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2004 CENELEC - All rights of exploitation in any form and by any means reserved worl
9、dwide for CENELEC members. Ref. No. EN 60115-9:2004 E ICS 31.040.10 English version Fixed resistors for use in electronic equipment Part 9: Sectional specification - Fixed surface mount resistor networks with individually measurable resistors (IEC 60115-9:2003) Rsistances fixes utilises dans les qui
10、pements lectroniques Partie 9: Spcification intermdiaire - Rseaux de rsistances fixes monts en surface avec des rsistances mesurables individuellement (CEI 60115-9:2003) Festwiderstnde zur Verwendung in Gerten der Elektronik Teil 9: Rahmenspezifikation - Oberflchenmontierbare Netzwerke aus Festwider
11、stnden mit einzeln messbaren Widerstnden (IEC 60115-9:2003) This European Standard was approved by CENELEC on 2004-02-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard w
12、ithout any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other lan
13、guage made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estoni
14、a, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. Foreword The text of document 40/1344/FDIS, future edition 1 of IEC 60115-9, prepared
15、 by IEC TC 40, Capacitors and resistors for electronic equipment, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 60115-9 on 2004-02-01. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical
16、 national standard or by endorsement (dop) 2004-11-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2007-02-01 Annex ZA has been added by CENELEC. _ Endorsement notice The text of the International Standard IEC 60115-9:2003 was approved by CENELEC as
17、a European Standard without any modification. _ Page2 EN601159:2004FIXED RESISTORS FOR USE IN ELECTRONIC EQUIPMENT Part 9: Sectional specification: Fixed surface mount resistor networks with individually measurable resistors 1 General 1.1 Scope This part of IEC 60115 is applicable to fixed surface m
18、ount resistor networks with individually measurable resistors for use in electronic equipment. 1.2 Object The object of this standard is to prescribe preferred ratings and characteristics and to select from IEC 60115-1, the appropriate Quality Assessment procedures, tests and measuring methods and t
19、o give general performance requirements for this type of resistor. Test severities and requirements prescribed in detail specifications referring to this sectional specification must be of equal or higher performance level, because lower performance levels are not permitted. 1.3 Normative references
20、 The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 60063:1963, Preferred number series for resi
21、stors and capacitors Amendment 1 (1967) Amendment 2 (1977) IEC 60068-1: Environmental testing Part 1: General and guidance IEC 60068-2-1: Environmental testing Part 2: Tests. Tests A: Cold IEC 60068-2-2: Environmental testing Part 2: Tests. Tests B: Dry heat IEC 60115-1:1999, Fixed resistors for use
22、 in electronic equipment Part 1: Generic specification 1.4 Information to be given in a detail specification Detail specifications shall be derived from the relevant blank detail specification. Detail specifications shall not specify requirements inferior to those of the generic, sectional specifica
23、tion or blank detail specification. When more severe requirements are included, they shall be listed in 1.8 of the detail specification and indicated in the test schedules, for example by an asterisk. Page3 EN601159:2004The following information shall be given in each detail specification and the va
24、lues quoted shall preferably be selected from those given in the appropriate clause of this sectional specification. 1.4.1 Outline drawing and dimensions There shall be an illustration of the surface mount resistor network as an aid to easy recognition and for comparison of the surface mount resisto
25、r network with others. Dimensions and their associated tolerances, which affect interchangeability and mounting, shall be given in the detail specification. All dimensions shall be stated in millimetres. Normally the numerical values shall be given for the length, width and thickness of the body. Sc
26、hematic diagrams and pin identifications shall be given in the detail specification. Those are prescribed in Annex A. Configurations of terminations shall be given in the detail specification. Those are prescribed in Annex B. When the outline drawing is other than described above, the detail specifi
27、cation shall state such dimensional information as will adequately describe the surface mount resistor network. 1.4.2 Mounting The detail specification shall give guidance on methods of mounting for normal use. Mounting for test and measurement purposes (when required) shall be in accordance with 4.
28、31 of IEC 60115-1. 1.4.3 Style (2.2.2 of IEC 60115-1) The styles given in Table 1 are preferred. All dimensions are in mm. Table 1 Style and outline dimensions Dimensions in mm Code Length L Width W Thickness T Diagram a) Construction of terminalsa) 1005X2 1 0,1 1 0,1 0,35 0,1 AC o n v e x 1005X4 2
29、0,1 1 0,1 0,4 0,15 A Convex Concave 1608X2 1,6 0,2 1,6 0,2 0,55 0,15 A Convex Concave 1608X4 3,2 0,2 1,6 0,2 0,55 0,15 A Convex Concave 3216X4 5,08 0,2 3,1 0,2 0,55 0,15 A Convex Concave 3216 3,2 0,2 1,6 0,2 0,5 0,15 B, C Convex 4021 4 0,2 2,1 0,2 0,6 0,15 D Concave 6431 6,4 0,2 3,1 0,2 0,6 0,15 B,
30、C Convex Concave a) Diagrams are shown in Annex A. Constructions of terminals are shown in Annex B. Page4 EN601159:20041.4.4 Ratings and characteristics The ratings and characteristics shall be in accordance with the relevant clauses of this specification together with the following: Rated resistanc
31、e range See 2.2.1. The preferred values are those of the E-series of IEC 60063. NOTE When products approved to the detail specification have different ranges, the following statement should be added: “The range of values available in each style is given in the qualified products list”. 1.4.5 Marking
32、 The detail specification shall specify the content of the marking on the surface mount resistor network and on the package. Surface mount resistor networks are generally not marked on the body. If some marking can be applied, the surface mount resistor network shall be clearly marked with the rated
33、 resistance and as many of the remaining items in 2.4 of IEC 60115-1 as possible. All items shall be marked on the package. Deviations from the above mentioned requirements shall be specifically stated. 2 Preferred ratings, characteristics and test severities 2.1 Preferred ratings and characteristic
34、s The values given in detail specifications shall preferably be selected from the following: 2.1.1 Preferred climatic categories The surface mount resistor networks covered by this specification are classified into climatic categories according to the general rules given in IEC 60068-1. The lower an
35、d upper category temperature and the duration of the damp heat, steady state shall be chosen from the following: Lower category temperature: 55 C, 40 C, 25 C and 10 C. Upper category temperature: +85 C, +100 C, +125 C and +155 C. Duration of the damp heat, steady state test: 4, 10, 21 and 56 days. T
36、he severities for the cold and dry heat tests are the lower and upper category temperatures respectively. Because of the construction of some surface mount resistor networks these temperatures will occur between two of the preferred temperatures given in IEC 60068-2-1 and IEC 60068-2-2. In this even
37、t, the nearest preferred temperature within the actual temperature range of the surface mount resistor network shall be chosen for this severity. 2.1.2 Temperature coefficients and temperature characteristics of resistance The preferred limits of change in resistance for the temperature characterist
38、ics of resistance test are given in Table 2. Page5 EN601159:2004Each line in the table gives the preferred temperature coefficient and corresponding temperature characteristic for 20 C to 70 C and limits of change in resistance for the measurement of the temperature characteristic of resistance (see
39、 4.8 of IEC 60115-1) on the basis of category temperature ranges of 2.1.1 of this sectional specification. Table 2 Temperature coefficients and temperature characteristics of resistance Temperature characteristic of resistance (limits of percentage change in resistance) Temper- ature coeffi- cient T
40、emper- ature charac- teristic 20/70 C Reference temperature /lower category temperature Reference temperature /upper category temperature 10 6 /K % +20/55 +20/40 +20/25 +20/10 +20/+85 +20/+100 +20/+125 +20/+155 500 2,5 3,75 3 2,25 1,500 3,25 4 5,25 6,75 250 1,25 1,88 1,5 1,13 0,750 1,62 2 2,62 3,38
41、100 0,5 0,75 0,6 0,45 0,300 0,65 0,8 1,05 1,35 50 0,25 0,375 0,3 0,23 0,150 0,325 0,4 0,525 0,675 25 0,125 0,188 0,15 0,113 0,075 0,162 0,2 0,262 0,338 15 0,075 0,113 0,09 0,068 0,045 0,098 0,12 0,158 0,203 10 0,05 0,075 0,06 0,045 0,030 0,065 0,08 0,105 0,135 NOTE 1 Resistors having an upper catego
42、ry temperature of +85 C need not be measured between 20 C and 70 C. NOTE 2 If measurements are required at additional temperatures, these shall be specified in the detail specification. 2.1.3 Limits for change in resistance For each stability class the preferred limits for change in resistance for e
43、ach of the tests listed in the heading of Table 3 are as indicated. Table 3 Limits for change in resistance Stability class in % Long-term tests 4.23 Climatic sequence 4.24 Damp heat, steady state 4.25.1 Endurance at 70 C 4.25.3 Endurance at upper category temperature Short-term tests 4.13 Overload
44、4.18 Resistance to soldering heat 4.19 Rapid change of temperature 4.32 Shear 4.33 Substrate bending test 5 3 2 1 0,5 0,25 0,1 (5 % +0,1 ) (3 % +0,1 ) (2 % +0,1 ) (1 % +0,05 ) (0,5 % +0,05 ) (0,25 %+0,05 ) (0,1 % +0,01 ) (1 % +0,05 ) (0,5 % +0,05 ) (0,5 % +0,05 ) (0,25 %+0,05 ) (0,1 % +0,01 ) (0,05
45、%+0,01 ) (0,02 %+0,01 ) NOTE The clause numbers in the heading refer to IEC 60115-1. Page6 EN601159:20042.2 Preferred values of ratings 2.2.1 Rated resistance See 2.2.6 of IEC 60115-1. 2.2.2 Tolerances on rated resistance The preferred tolerances on rated resistance are: 5 %; 2 %; 1 %; 0,5 %; 0,25 %
46、 and 0,1 %. 2.2.3 Rated dissipation (in the mounted state) The preferred values of rated dissipation, at 70 C, are: For the network: 0,125 W; 0,25 W and 0,5 W. For the resistor element: 0,03 W; 0,05 W; 0,063 W; 0,1 W and 0,125 W. The detail specification shall prescribe the applicable value of rated
47、 dissipation for each resistor element in the network and also the maximum allowable total dissipation for the network. The derated values of dissipation at temperatures in excess of 70 C shall be as indicated by the curve in Figure 1: Figure 1 Rated dissipation curve A larger area of operation may
48、be given in the detail specification, provided it includes all of the area given above. In this event, the detail specification shall state the maximum allowable dissipation at temperatures other than 70 C. All break points on the curve shall be verified by test. 2.2.4 Limiting element voltage The preferred values of limiting element voltage are: 25 V; 50 V; 100 V and 200 V DC or AC r.m.s. 2.2.5 Insulation resistance (if applicable) The insulation resistance shall be not less than 1 G after dry heat tests. 1000 Lower category temperature +70