1、BSI Standards PublicationSpecifications for particular types of winding wiresPart 40: Glass-fibre braided resin or varnish-impregnated, bare or enamelled rectangular copper wire, temperature index 200BS EN 60317-40:2015National forewordThis British Standard is the UK implementation of EN 60317-40:20
2、15. It isidentical to IEC 60317-40:2015. It supersedes BS EN 60317-40:1995 which iswithdrawn.The UK participation in its preparation was entrusted to TechnicalCommittee L/-/99, Miscellaneous Standards - Electrical.A list of organizations represented on this committee can be obtained onrequest to its
3、 secretary.This publication does not purport to include all the necessary provisions ofa contract. Users are responsible for its correct application. The British Standards Institution 2015.Published by BSI Standards Limited 2015ISBN 978 0 580 83426 4ICS 29.060.10Compliance with a British Standard ca
4、nnot confer immunity fromlegal obligations.This British Standard was published under the authority of theStandards Policy and Strategy Committee on 31 May 2015.Amendments/corrigenda issued since publicationDate Text affectedBRITISH STANDARDBS EN 60317-40:2015EUROPEAN STANDARD NORME EUROPENNE EUROPIS
5、CHE NORM EN 60317-40 April 2015 ICS 29.060.10 Supersedes EN 60317-40:1994 English Version Specifications for particular types of winding wires - Part 40: Glass-fibre braided resin or varnish-impregnated, bare or enamelled rectangular copper wire, temperature index 200 (IEC 60317-40:2015) Spcificatio
6、ns pour types particuliers de fils de bobinage - Partie 40: Fil de section rectangulaire en cuivre nu ou maill, recouvert dune tresse de fibres de verre imprgnes de rsine ou de vernis, indice de temprature 200 (IEC 60317-40:2015) Technische Lieferbedingungen fr bestimmte Typen von Wickeldrhten - Tei
7、l 40: Flachdrhte aus Kupfer, blank oder lackisoliert, umsponnen mit Glasgewebe, imprgniert mit Harz oder Lack, Temperaturindex 200 (IEC 60317-40:2015) This European Standard was approved by CENELEC on 2015-04-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which sti
8、pulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member. This Euro
9、pean Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CENELEC me
10、mbers are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, N
11、orway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung CEN-CENELEC Management Centre: Ave
12、nue Marnix 17, B-1000 Brussels 2015 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members. Ref. No. EN 60317-40:2015 E BS EN 60317-40:2015EN 60317-40:2015 - 2 - Foreword The text of document 55/1512/FDIS, future edition 2 of IEC 60317-40, prepared by
13、IEC/TC 55 “Winding wires“ was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as EN 60317-40:2015. The following dates are fixed: latest date by which the document has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2016
14、-01-01 latest date by which the national standards conflicting with the document have to be withdrawn (dow) 2018-04-01 This document supersedes EN 60317-40:1994. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC and/or CEN s
15、hall not be held responsible for identifying any or all such patent rights. Endorsement notice The text of the International Standard IEC 60317-40:2015 was approved by CENELEC as a European Standard without any modification. In the official version, for Bibliography, the following notes have to be a
16、dded for the standards indicated: IEC 60264 (series) NOTE Harmonized as EN 60264 (series). IEC 60317 (series) NOTE Harmonized as EN 60317 (series). IEC 60851 (series) NOTE Harmonized as EN 60851 (series). BS EN 60317-40:2015- 3 - EN 60317-40:2015 Annex ZA (normative) Normative references to internat
17、ional publications with their corresponding European publications The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of t
18、he referenced document (including any amendments) applies. NOTE 1 When an International Publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is availa
19、ble here: www.cenelec.eu. Publication Year Title EN/HD Year IEC 60317-0-5 2006 Specifications for particular types of winding wires - Part 0-5: General requirements - Glass-fibre braided resin or varnish impregnated, bare or enamelled rectangular copper wire EN 60317-0-5 2007 BS EN 60317-40:2015 2 I
20、EC 60317-40:2015 IEC 2015 CONTENTS FOREWORD . 3 INTRODUCTION . 5 1 Scope 6 2 Normative references 6 3 Terms, definitions, general notes and appearance . 6 3.1 Terms and definitions 6 3.2 General notes . 6 3.2.1 Methods of test 6 3.2.2 Winding wire 6 3.3 Appearance 7 4 Dimensions 7 5 Electrical resis
21、tance 7 6 Elongation . 7 7 Springiness . 7 8 Flexibility and adherence . 7 9 Heat shock 7 10 Cut-through . 7 11 Resistance to abrasion 7 12 Resistance to solvents . 7 13 Breakdown voltage 7 14 Continuity of insulation 8 15 Temperature index 8 16 Resistance to refrigerants 8 17 Solderability 8 18 Hea
22、t or solvent bonding . 8 19 Dielectric dissipation factor 8 20 Resistance to transformer oil . 8 21 Loss of mass . 8 23 Pin hole test 8 30 Packaging . 8 Bibliography 9 BS EN 60317-40:2015IEC 60317-40:2015 IEC 2015 3 INTERNATIONAL ELECTROTECHNICAL COMMISSION _ SPECIFICATIONS FOR PARTICULAR TYPES OF W
23、INDING WIRES Part 40: Glass-fibre braided resin or varnish-impregnated, bare or enamelled rectangular copper wire, temperature index 200 FOREWORD 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising all national electrotechnical committees
24、 (IEC National Committees). The object of IEC is to promote international co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Repo
25、rts, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with may participate in this preparatory work. International, governmental and n
26、on-governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for Standardization (ISO) in accordance with conditions determined by agreement between the two organizations. 2) The formal decisions or agreements
27、of IEC on technical matters express, as nearly as possible, an international consensus of opinion on the relevant subjects since each technical committee has representation from all interested IEC National Committees. 3) IEC Publications have the form of recommendations for international use and are
28、 accepted by IEC National Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any misinterpretation by any end user. 4) In order to promote inter
29、national uniformity, IEC National Committees undertake to apply IEC Publications transparently to the maximum extent possible in their national and regional publications. Any divergence between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in t
30、he latter. 5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any services carried out by independent certification bodies. 6) All user
31、s should ensure that they have the latest edition of this publication. 7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and members of its technical committees and IEC National Committees for any personal injury, property damage or othe
32、r damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC Publications. 8) Attention is drawn to the Normative references cited in this publication. U
33、se of the referenced publications is indispensable for the correct application of this publication. 9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent rights. IEC shall not be held responsible for identifying any or all such patent
34、 rights. International Standard IEC 60317-40 has been prepared by IEC technical committee 55: Winding wires. This second edition cancels and replaces the first edition published in 1992, Amendment 1:1997 and Amendment 2:2005. This edition constitutes a technical revision. This edition includes the f
35、ollowing significant technical changes with respect to the previous edition: revision to Clause 2, Normative references; new 3.2.2 containing general notes on winding wire, formerly a part of the scope; revision to references to IEC 60317-0-5 to clarify that its application is normative. BS EN 60317
36、-40:2015 4 IEC 60317-40:2015 IEC 2015 The text of this standard is based on the following documents: FDIS Report on voting 55/1512/FDIS 55/1521/RVD Full information on the voting for the approval of this standard can be found in the report on voting indicated in the above table. This publication has
37、 been drafted in accordance with the ISO/IEC Directives, Part 2. A list of all parts in the IEC 60317 series, published under the general title Specifications for particular types of winding wires, can be found on the IEC website. The numbering of clauses in this standard is not continuous from Clau
38、ses 20 and 30 in order to reserve space for possible future wire requirements prior to those for wire packaging. The committee has decided that the contents of this publication will remain unchanged until the stability date indicated on the IEC website under “http:/webstore.iec.ch“ in the data relat
39、ed to the specific publication. At this date, the publication will be reconfirmed, withdrawn, replaced by a revised edition, or amended. BS EN 60317-40:2015IEC 60317-40:2015 IEC 2015 5 INTRODUCTION This part of IEC 60317 forms an element of a series which deals with insulated wires used for windings
40、 in electrical equipment. The series has three groups describing: 1) Winding wires Test methods (IEC 60851 series); 2) Specifications for particular types of winding wires (IEC 60317 series); 3) Packaging of winding wires (IEC 60264 series). BS EN 60317-40:2015 6 IEC 60317-40:2015 IEC 2015 SPECIFICA
41、TIONS FOR PARTICULAR TYPES OF WINDING WIRES Part 40: Glass-fibre braided resin or varnish-impregnated, bare or enamelled rectangular copper wire, temperature index 200 1 Scope This part of IEC 60317 specifies the requirements of glass-fibre braided impregnated, bare, grade 1 or grade 2 enamelled rec
42、tangular copper winding wire, temperature index 200. NOTE For this type of wire, the heat shock test is inappropriate and therefore a heat shock temperature cannot be established. Consequently, a class based on the requirements for temperature index and heat shock temperature cannot be specified. 2
43、Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendme
44、nts) applies. IEC 60317-0-5:2006, Specifications for particular types of winding wires Part 0-5: General requirements Glass-fibre braided, resin or varnish impregnated, bare or enamelled rectangular copper wire 3 Terms, definitions, general notes and appearance 3.1 Terms and definitions For the purp
45、oses of this document, the terms and definitions given in 3.1 of IEC 60317-0-5:2006 apply. 3.2 General notes 3.2.1 Methods of test Subclause 3.2 of IEC 60317-0-5:2006 applies. In case of inconsistencies between IEC 60317-0-5 and this part of IEC 60317, the latter shall prevail. 3.2.2 Winding wire Th
46、e enamelled wire shall have a temperature index of at least 200 and shall be agreed between purchaser and supplier. The temperature index of the wire is dependent upon the type of impregnating agent used. The impregnating agent applied to the glass fibre shall have a minimum temperature index of 200
47、. Coverings applicable to this specification have the following grades of thickness: BGL1, bare conductor with one braided layer of glass fibre; BGL2, bare conductor with two braided layers of glass fibre; BS EN 60317-40:2015IEC 60317-40:2015 IEC 2015 7 grade 1 BGL1, enamelled grade 1 (grade 1) with
48、 one braided layer of glass fibre (BGL1); grade 1 BGL2, enamelled grade 1 (grade 1) with two braided layers of glass fibre (BGL2); grade 2 BGL1, enamelled grade 2 (grade 2) with one braided layer of glass fibre (BGL1); grade 2 BGL2, enamelled grade 2 (grade 2) with two braided layers of glass fibre
49、(BGL2). 3.3 Appearance Subclause 3.3 of IEC 60317-0-5:2006 applies. 4 Dimensions Clause 4 of IEC 60317-0-5:2006 applies. 5 Electrical resistance Clause 5 of IEC 60317-0-5:2006 applies. 6 Elongation Clause 6 of IEC 60317-0-5:2006 applies. 7 Springiness Clause 7 of IEC 60317-0-5:2006 applies. 8 Flexibility and adherence Clause 8 of IEC 60317-0-5:2006 applies. 9 Heat shock Test inappropriate. 10 Cut-through Test inappropriate. 11 Resistance to abrasion Test inappropriate. 12