1、BRITISH STANDARDBS EN 60317-44:1997+A1:2010Specifications for particular types of winding wires Part 44: Aromatic polyimide tape wrapped rectangular copper wire, class 240ICS 29.060.10National forewordThis British Standard is the UK implementation of EN 60317-44:1997+A1:2010. It is identical to IEC
2、60317-44:1997, incorporating amendment 1:2010. It supersedes BS EN 60317-44:1997 which is withdrawn.The start and finish of text introduced or altered by amendment is in-dicated in the text by tags. Tags indicating changes to IEC text carry the number of the IEC amendment. For example, text altered
3、by IEC amendment 1 is indicated by !“.The UK participation in its preparation was entrusted to Technical Committee GEL/55, Winding wires.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary pr
4、ovisions of a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations.BS EN 60317-44:1997+A1:2010This British Standard, having been prepared under the direction of the Electrotechnical Sector Board, was published un
5、der the authority of the Standards Board and comes into effect on on 15 August 1997 BSI 2010Amendments/corrigenda issued since publicationDate Comments 31 July 2010 Implementation of IEC amendment 1:2010 with CENELEC endorsement A1:2010 ISBN 978 0 580 67190 6EUROPEAN STANDARD NORME EUROP ENNE EUROPI
6、SCHE NORMEN 60317-44:1997+A1April 2010ICS 29.060.10Descriptors: Winding, electric wire, insulated wire, wrapped wire, copper, aromatic polyimide, rectangular shape, specification, dimensionEnglish versionSpecifications for particular types of winding wires Part 44: Aromatic polyimide tape wrapped re
7、ctangular copper wire, class 240(IEC 60317-44:1997+A1:2010)Spcifications pour types particuliers de fils de bobinage Partie 44: Fil de section rectangulaire en cuivre recouvert d un ruban de polyimide aromatique, classe 240 (CEI 60317-44:1997+A1:2010)Technische Lieferbedingungen f r bestimmte Typen
8、von Wickeldr hten Teil 44: Flachdr hte aus Kupfer, mit Band aus aromatischem Polyimid umwickelt, Klasse 240 (IEC 60317-44:1997+A1:2010)This European Standard was approved by CENELEC on 1997-03-11. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the condi
9、tions for giving this European Standard the status of a national standard without any alteration.Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member.This European Standard exists in thre
10、e official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions.CENELEC members are the national electrotechnical
11、 committees of Austria, Belgium, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom.CENELECEuropean Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique
12、 Europ isches Komitee f r Elektrotechnische NormungCentral Secretariat: rue de Stassart 35, B-1050 Brussels 1997 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.Ref. No. EN 60317-44:1997 E+A12ForewordThe text of document 55/541/FDIS, future edit
13、ion 1 of IEC 60317-44, prepared by IEC TC 55, Winding wires, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 60317-44 on 1997-03-11.The following dates were fixed: Annexes designated normative are part of the body of the standard.In this standard, Annex ZA is normati
14、ve.Annex ZA has been added by CENELEC.Endorsement noticeThe text of the International Standard IEC 60317-44:1997 was approved by CENELEC as a European Standard without any modification.ContentsPageForeword 2Introduction 31 Scope 32 Normative references 33 Definitions and general notes on methods of
15、test 34 Dimensions 45 Electrical resistance 56 Elongation 57 Springiness 68 Flexibility and adherence 69 Heat shock 610 Cut-through 611 Resistance to abrasion 612 Resistance to solvents 613 Breakdown voltage 614 Continuity of insulation 615 Temperature index 716 Resistance to refrigerants 717 Solder
16、ability 718 Heat or solvent bonding 719 Dielectric dissipation factor 720 Resistance to transformer oil 721 Loss of mass 730 Packaging 7Annex ZA (normative) Normative reference to international publications with their corresponding European publications 8Table 1 Minimum increases due to the insulati
17、on 5Table 2 Maximum increases due to the insulation 5Table 3 Elongation requirements 6Table 4 Breakdown voltage 6latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 1997-12-01latest date by which the national st
18、andards conflicting with the EN have to be withdrawn (dow) 1997-12-01Foreword to amendment A1The text of document 55/1182/FDIS, future amendment 1 to IEC 660317-44:1997, prepared by IEC TC 55, Winding wires, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as amendment A1 t
19、o EN 60317-44:1997 on 2010-04-01. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and CENELEC shall not be held responsible for identifying any or all such patent rights. The following dates were fi xed: Endorsement noticeThe
20、text of amendment 1:2010 to the International Standard IEC 60317-44:1997 was approved by CENELEC as an amendment to the European Standard without any modifi cation. BSI 2010BS EN 60317-44:1997+A1:2010EN 60317-44:1997+A1:2010 (E)latest date by which the amendment has to be implemented at national lev
21、el by publication of an identical national standard or by endorsement (dop) 2011-01-01 latest date by which the national standards con icting with the amendment have to be withdrawn (dow) 2013-04-013IntroductionThis part of IEC 317 forms an element of a series of standards which deals with insulated
22、 wires used for windings in electrical equipment. The series has three groups describing:1) methods of test (IEC 851);2) specifications (IEC 317);3) packaging (IEC 264).1 ScopeThis part of IEC 317 specifies the requirements of tape wrapped rectangular copper winding wire of class 240. The insulation
23、 consists of one or two wrappings of aromatic polyimide tape.Class 240 is a thermal class that requires a temperature index of 240 and a heat shock temperature of at least 260 C.NOTE In some countries, e.g. Canada, Russia, USA, this product is assigned a class 220.The tape is coated on one or both s
24、ides with a suitable adhesive, for instance, fluorinated ethylene propylene. After wrapping, the tape is heat-sealed to form a continuous and adherent sheath.Specific requirements may be subject to contract.The temperature in degrees Celsius corresponding to the temperature index is not necessarily
25、that at which the wire is recommended to be used and this will depend on many factors, including the types of equipment involved.The range of nominal conductor dimensions covered by this standard is: The specified combinations of width and thickness as well as the specified ratio width/thickness are
26、 given in IEC 317-0-2.When a reference is made to winding wire according to this standard, the following information should be given:reference to IEC 60317-44;dimension of the nominal conductor (width thickness);grade.Example: 60317-44 IEC 4,00 mm 1,00 mm grade A22 Normative referencesThe following
27、normative documents contain provisions which, through reference in this text, constitute provisions of this part of IEC 317. At the time of publication, the editions indicated were valid. All normative documents are subject to revision, and parties to agreements based on this part of IEC 317 are enc
28、ouraged to investigate the possibility of applying the most recent editions of the normative documents indicated below. Members of IEC and ISO maintain registers of currently valid International Standards.IEC 60172, Test procedure for the determination of the temperature index of enamelled winding w
29、ires. IEC 60317-0-2:1990, Specifications for particular types of winding wires Part 0: General requirements Section 2: Enamelled rectangular copper wire. IEC 60851, Methods of test for winding wires. ISO 3:1973, Preferred numbers Series of preferred numbers. 3 Definitions and general notes on method
30、s of test3.1 Terms and definitionsFor the purpose of this part of IEC 317, the following definitions apply.3.1.1 classthe thermal performance of a wire expressed by the temperature index and the heat shock temperaturewidth: min. 2,00 mm, max. 16,00 mm;thickness: min. 0,80 mm, max. 5,60 mm. BSI 2010B
31、S EN 60317-44:1997+A1:2010EN 60317-44:1997+A1:2010 (E)!“43.1.2 conductorthe bare metal after removal of the insulation3.1.3 coveringa material which is wound, wrapped or braided around a bare or insulated conductor3.1.4 crackan opening in the insulation which exposes the conductor to view at the sta
32、ted magnification3.1.5 gradea range of thickness of the insulation of a wire3.1.6 insulationa coating or covering on the conductor with the specific function of withstanding voltage3.1.7 nominal conductor dimensionthe designation of the conductor size in accordance with IEC 3173.1.8 winding wirea wi
33、re used for winding a coil to provide a magnetic field3.1.9 wirea conductor coated or covered with an insulation3.2 General notes on methods of testAll methods of test used in this part of IEC 317 are given in IEC 851.The clause numbers used in this standard are identical with the respective test nu
34、mbers of IEC 851.In case of inconsistencies between IEC 851 on methods of test and this part of IEC 317, the latter shall prevail.Where no specific range of nominal conductor dimensions is given for a test, the test applies to all nominal conductor dimensions covered by the specification sheet.Unles
35、s otherwise specified, all tests shall be carried out at a temperature from 15 C to 35 C and a relative humidity from 45 % to 75 %. Before measurements are made, the specimens shall be preconditioned under these atmospheric conditions for a time sufficient to allow the specimens to reach stability.T
36、he wire to be tested shall be removed from the packaging in such a way that the wire will not be subjected to tension or unnecessary bends. Before each test, sufficient wire should be discarded to ensure that any damaged wire is not included in the test specimens.4 DimensionsThe dimensions due to th
37、e insulation depend upon an agreement between purchaser and supplier. The dimensions in this standard shall be used as a guide in forming that agreement.4.1 Conductor dimensionsSee 4.1 of IEC 317-0-2.4.2 Tolerance on conductor dimensionsSee 4.2 of IEC 317-0-2.4.3 Rounding of cornersSee 4.3 of IEC 31
38、7-0-2. BSI 2010BS EN 60317-44:1997+A1:2010EN 60317-44:1997+A1:2010 (E)54.4 Increase in dimensions due to the insulationThe minimum increase in width or thickness due to the insulation shall be as given in Table 1.Table 1 Minimum increases due to the insulation4.5 Maximum overall dimensionsThe overal
39、l dimensions shall not exceed the sum of the maximum conductor dimensions given in 4.2 and the maximum increase in dimensions due to the insulation given in Table 2.Before wrapping, the conductor shall be completely free from copper dust and other extraneous matter.One or two tapes may be applied wi
40、th a degree of overlapping agreed upon between purchaser and supplier.The tape shall be wrapped on the conductor, tightly, evenly and free from creases or wrinkles, with the adhesive on the inside.After wrapping, the tape shall be heat-sealed by suitable means to form an adherent and continuous shea
41、th.Table 2 Maximum increases due to the insulationExample: The maximum overall dimensions of a wire with a nominal conductor width of 4,000 mm and a conductor thickness of 1,000 mm, insulated with a single tape to grade A.3 (including adhesive) are: 5 Electrical resistanceThe resistance of the wire
42、shall be expressed as the d.c. resistance at 20 C. The method used shall provide an accuracy of 0,5 %.The maximum value of resistance shall be not greater than the value calculated for the minimum tolerated cross-sectional area of the conductor resulting from the minimum dimensions in thickness and
43、width and the maximum for the corner radius, with a resistivity of 1/58 7 mm2m1.One measurement shall be made.6 ElongationSingle tape Double tapeGrade Minimum increase in dimensions due to the insulationGrade Minimum increase in dimensions due to the insulationmm mmA1 0,100 B1 0,200A2 0,130 B2 0,260
44、A3 0,170 B3 0,340A4 0,210 B4 0,430A5 0,260 B5 0,510Single tape Double tapeGrade Maximum increase in dimensions due to the insulationGrade Maximum increase in dimensions due to the insulationmm mmA1 0,140 B1 0,280A2 0,180 B2 0,360A3 0,240 B3 0,480A4 0,300 B4 0,600A5 0,340 B5 0,680for the width: 4,050
45、 mm + 0,240 mm = 4,290 mm; andfor the thickness: 1,030 mm + 0,240 mm = 1,270 mm. BSI 2010BS EN 60317-44:1997+A1:2010EN 60317-44:1997+A1:2010 (E)Test inappropriate. ! “6Table 3 Elongation requirements7 SpringinessThe wire shall not exceed the maximum springback of 5,5.8 Flexibility and adherence8.1 M
46、andrel winding testThe covering shall show no crack or delamination after the wire has been bent flatwise and edgewise on a mandrel with a diameter four times the width and thickness, respectively.8.2 Adherence testThe wire shall be stretched by 15 % for a single taped wire or by 10 % for a double t
47、aped wire.The distance of loss of adhesion shall be less than one times the conductor width.9 Heat shockThe wire shall be stretched by 15 % for a single taped wire or by 10 % for a double taped wire.The covering shall show no crack.The minimum heat shock temperature shall be 260 C.10 Cut-throughWhen
48、 using a nominal round conductor diameter of 1,600 mm, no failure shall occur within 2 min at 450 C.11 Resistance to abrasionTest inappropriate.12 Resistance to solventsTest inappropriate.13 Breakdown voltageAt least four of the five specimens tested shall not break down at a voltage less than or eq
49、ual to that given in Table 4.Table 4 Breakdown voltage14 Continuity of insulationThe method of test and requirement may be agreed upon between purchaser and supplier.Nominal thickness of the conductormmMinimum elongationOver Up to and including %2,500 302,500 5,600 33Nominal conductor thickness Minimum breakdown voltage (r.m.s.)mm Single tape Double tapeOver Up to and including Grade VoltageVGrade VoltageVA1 1 500 B1 2 500A2 2 000 B2 3 0001,600 5,600 A3 2 300 B3 3 500A4 2 600 B4 4 200A5 3 000 B5 5 000 BSI 2010BS EN 60317-44:1997+A1:201