1、BRITISH STANDARDBS EN 60384-2-1:2005Fixed capacitors for use in electronic equipment Part 2-1: Blank detail specification: Fixed metallized polyethylene-terephthalate film dielectric d.c. capacitors Assessment levels E and EZICS 31.060.30g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g4
2、4g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58Incorporating corrigendum March 2010National forewordThis British Standard is the UK implementation of EN 60384-2-1:2005. It is identical to IEC 60384-2-1:2005. I
3、t supersedes BS QC 300401:1984 which is withdrawn.The UK participation in its preparation was entrusted to Technical Committee EPL/40X, Capacitors and resistors for electronic equipment.A list of organizations represented on this committee can be obtained on request to its secretary.This publication
4、 does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations.BS EN 60384-2-1:2005This British Standard was published under the authority of the Standards Pol
5、icy and Strategy Committee on 30 June 2006 BSI 2010Amendments/corrigenda issued since publicationDate Comments 31 March 2010 Supersession text amended ISBN 978 0 580 70365 2EUROPEAN STANDARD EN 60384-2-1 NORME EUROPENNE EUROPISCHE NORM December 2005 CENELEC European Committee for Electrotechnical St
6、andardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2005 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 60384-2
7、-1:2005 E ICS 31.060.30 English version Fixed capacitors for use in electronic equipment Part 2-1: Blank detail specification: Fixed metallized polyethylene-terephthalate film dielectric d.c. capacitors Assessment levels E and EZ (IEC 60384-2-1:2005) Condensateurs fixes utiliss dans les quipements l
8、ectroniques Partie 2-1: Spcification particulire cadre: Condensateurs fixes pour courant continu dilectrique en film de polytrphtalate dthylne mtallis Niveaux dassurances E et EZ (CEI 60384-2-1:2005) Festkondensatoren zur Verwendung in Gerten der Elektronik Teil 2-1: Vordruck fr Bauartspezifikation:
9、 Festkondensatoren mit metallisierter Kunststofffolie aus Polyethylen-Terephthalat fr Gleichspannung Qualittsbewertungsstufen E und EZ (IEC 60384-2-1:2005) This European Standard was approved by CENELEC on 2005-11-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations whic
10、h stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European
11、Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the n
12、ational electrotechnical committees of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and Unite
13、d Kingdom. Foreword The text of document 40/1594/FDIS, future edition 2 of IEC 60384-2-1, prepared by IEC TC 40, Capacitors and resistors for electronic equipment, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 60384-2-1 on 2005-11-01. The following dates were fixed
14、: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2006-08-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2008-11-01 Annex ZA has been added by CENELEC. _ En
15、dorsement notice The text of the International Standard IEC 60384-2-1:2005 was approved by CENELEC as a European Standard without any modification. _ EN 60384-2-1:2005 2 BS EN 60384-2-1:2005FIXED CAPACITORS FOR USE IN ELECTRONIC EQUIPMENT Part 2-1: Blank detail specification: Fixed metallized polyet
16、hylene-terephthalate film dielectric d.c. capacitors Assessment levels E and EZ INTRODUCTION Blank detail specification A blank detail specification is a supplementary document to the sectional specification and contains requirements for style and layout and minimum content of details specifications
17、. Detail specifications not complying with these requirements may not be considered as being in accordance with IEC specifications nor shall they be so described. In the preparation of detail specifications the content of 1.4 of the sectional specification shall be taken into account. The numbers be
18、tween brackets on the first page correspond to the following information which shall be inserted in the position indicated: Identification of the detail specification 1 The “International Electrotechnical commission“ or the National Standards Organization under whose authority the detail specificati
19、on is drafted. 2 The IEC or National Standards number of the detail specification, date of issue and any further information required by the national system. 3 The number and issue number of the IEC or national Generic Specification. 4 The IEC number of the blank detail specification. Identification
20、 of the capacitor 5 A short description of the type of capacitor. 6 Information on typical construction (when applicable). NOTE When the capacitor is not designed for use in printed board applications, this shall be clearly stated in the detail specification in this position. 7 Outline drawing with
21、main dimensions which are of importance for interchangeability and/or reference to the national or international documents for outlines. Alternatively, this drawing may be given in an appendix to the detail specification. 8 Application or group of applications covered and/or assessment level. NOTE T
22、he assessment level(s) to be used in a detail specification shall be selected from the sectional specification, 3.5.4. This implies that one blank detail specification may be used in combination with several assessment levels provided the grouping of the tests does not change. 9 Reference data on th
23、e most important properties, to allow comparison between the various capacitor types. 3 EN 60384-2-1:2005BS EN 60384-2-1:20051 IEC 60384-2-1-XXX QC XXXXXXXXXXX 2 IEC 60384-2-1 QC XXXXXX 4 ELECTRONIC COMPONENTS OF ASSESSED QUALITY IN ACCORDANCE WITH: 3 FIXED METALLIZED POLYETHYLENE-TEREPHTHALATE FILM
24、 DIELECTRIC DC CAPACITORS 5 6 Outline drawing (see table 1 (first angle projection) 7 (Other shapes are permitted within the dimensions given) Assessment levels E and EZ 8 Performance grade: NOTE For 1 to 9: see previous page. Information on the availability of components qualified to this detail sp
25、ecification is given in IEC QC 001005 9 1 General data 1.1 Recommended method(s) of mounting (to be inserted) See IEC 60384-2, 1.4.2. 1.2 Dimensions Table 1 Case size reference and dimensions Dimensions Case size reference L H d . . . . . . . When there is no case size reference, Table 1 may be omit
26、ted and the dimensions shall be given in Table 2, which then becomes Table 1. The dimensions shall be given as maximum dimensions or as nominal dimensions with a tolerance. 4 EN 60384-2-1:2005BS EN 60384-2-1:20051.3 Ratings and characteristics Capacitance range (see Table 2) Tolerance on rated capac
27、itance Rated voltage (see Table 2) Category voltage (if applicable) (see Table 2) Climatic category Rated temperature Maximum a.c. voltage (if applicable) Maximum pulse load Tangent of loss angle Insulation resistance Maximum dissipation Table 2 Values of capacitance and of voltage related to case s
28、izes Rated voltage Category voltage* Case size Case size Case size Case size Rated capacitance (in nF and/or F) * If different from the rated voltage. 1.4 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the ed
29、ition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 60384-1, Fixed capacitors for use in electronic equipment Part 1: Generic specification IEC 60384-2, Fixed capacitors for use in electronic equipment Part 2: Sectional s
30、pecification: Fixed metallized polyethylene-terephthalate film dielectric d.c. capacitors 1.5 Marking The marking of the capacitor and the packing shall be in accordance with the requirements of IEC 60384-2, 1.6. NOTE The details of the marking of the component and packing must be given in full in t
31、he detail specification. 1.6 Ordering information Orders for capacitors covered by this specification shall contain, in clear or in coded form, the following minimum information: a) Rated capacitance; b) Tolerance on rated capacitance; c) Rated d.c. voltage; d) Number and issue reference of the deta
32、il specification and style reference. 5 EN 60384-2-1:2005BS EN 60384-2-1:20051.7 Certified records of released lots Required/not required. 1.8 Additional information (not for inspection purposes) 1.9 Additional or increased severities or requirements to those specified in the generic and/or sectiona
33、l specification NOTE Additions or increased requirements should be specified only when essential. Table 3 Other characteristics This table is to be used for defining characteristics which are additional to or more severe than those given in the sectional specification. 2 Inspection requirements 2.1
34、Procedures 2.1.1 For qualification approval the procedures shall be in accordance with the sectional specification, IEC 60384-2, 3.4. 2.1.2 For quality conformance inspection the test schedule (Table 4) includes sampling, periodicity, severities and requirements. The formation of inspection lots is
35、covered by 3.5.1 of the sectional specification IEC 60384-2. Table 4 Test schedule for Quality Conformance Inspection E lev. EZ lev. IL AQL n cSubclause number and test a) D or ND c) Conditions of test1) c) Performance requirements a) Group A inspection (lot-by-lot) Subgroup A0 4.3.2 Capacitance 4.3
36、.3 Tangent of loss angle 4.3.1 Voltage proof (Test A) 4.3.4 Insulation resistance (Test A) ND Frequency : 1 kHz for all capacitance values Method: Measuring point 1a Measuring point 1a 100%d) Within specified tolerance As in 4.3.3.2 No breakdown or flashover. Self-healing breakdowns allowed As in 4.
37、3.4.3 Subgroup A1 ND S-3 2,5%b) 0 4.1 Visual examination As in 4.1 Legible marking and as specified in 1.5 of this specification 4.1 Dimensions (gauging) As specified in Table 1 of this specification Subgroup A2 ND S-3 1,0%b) 0 4.2.2 Capacitance Within specified tolerance 4.2.3 Tangent of loss angle
38、 As in 4.2.3.2 4.2.1 Voltage proof (Test A) No breakdown or flashover 4.2.4 Insulation resistance (Test A) As in 4.2.4.2 6 EN 60384-2-1:2005BS EN 60384-2-1:2005Table 4 (continued) E lev. EZ lev. IL AQL n cSubclause number and test a) D or ND c) Conditions of test1) c) Performance requirements a) Gro
39、up B inspection (lot-by-lot) Subgroup B1 ND S-3 2,5%b) 0 4.5 Solderability Without ageing Method: . Good tinning as evidenced by free flowing of the solder with wetting of the termina-tions or solder shall flow within . s, as applicable 4.15 Solvent resistance of the marking (if applicable) Solvent:
40、 . Solvent temperature: . Method 1 Rubbing material: . Recovery time: Legible marking NOTES: see end of table. 7 EN 60384-2-1:2005BS EN 60384-2-1:2005Table 4 (continued) Subclause number and test a) D orND c) Conditions of test a) Sample size and criterion of acceptability c)Performance requirements
41、 a) E EZ p n c p n c Group C inspection (periodic) Subgroup C1A Part of sample of Subgroup C1 D 6 9 1 6 5 0 4.1 Dimensions (detail) See detail specification 4.3.1 Initial measurements Capacitance Tangent of loss angle: for CR 1 F: at 1 kHz CR 1 F: at 10 kHz 4.3 Robustness of terminationsVisual exami
42、nation No visible damage 4.4 Resistance to soldering heat Method: 4.14 Component solvent resistance (if applicable) Solvent: . Solvent temperature: . Method 2 Recovery time: See detail specification 4.4.2 Final measurements Visual examination No visible damage Legible marking Capacitance C/C 2 % of
43、value measured initially Tangent of loss angle Increase of tan : 0,003 C 1 F Grade 10,002 C 1 F Grade 10,005 C 1 F Grade 20,003 C 1 F Grade 2compared to values measured in 4.3.1 Subgroup C1B Other part of sample of Subgroup C1 D 6 18 1 6 5 0 4.6.1 Initial measurements Capacitance Tangent of loss ang
44、le: for CR 1 F: at 1 kHz CR 1 F: at 10 kHz 4.6 Rapid change of temperature TA= Lower category temperature TB= Upper category temperature Five cycles Duration t = 30 min Visual examination No visible damage 4.7 Vibration Method of mounting: see 1.1 of this specification Frequency range: . Hz to . Hz
45、Amplitude 0,75 mm or acceleration 100 m/s2(whichever is the less severe) Total duration: 6 h 8 EN 60384-2-1:2005BS EN 60384-2-1:2005Table 4 (continued) Subclause number and test a) D or NDc) Conditions of test a) Sample size and criterion of acceptability c)Performance requirements a) E EZ p n c p n
46、 c 4.7.2 Final inspection Visual examination No visible damage 4.8 Bump (or shock, see 4.9) Method of mounting: see 1.1 of this specification Number of bumps: Acceleration: m/s2Duration of pulse: ms 4.9 Shock (or bump, see 4.8) Method of mounting: see 1.1 of this specification Acceleration: m/s2Dura
47、tion of pulse: ms 4.8.3 or 4.9.3 Final measurements Visual examination No visible damage Capacitance C/C 5 % of the value measured in 4.6.1 Tangent of loss angle Increase of tan : 0,003 C 1 F Grade 1 0,002 C 1 F Grade 1 0,005 C 1 F Grade 2 0,003 C 1 F Grade 2 compared to values measured in 4.6.1 Ins
48、ulation resistance 50 % of the values in 4.2.4.2 Subgroup C1 Combined sample of specimens of Subgroups C1A and C1B D 6 27 2 6 10 0 4.10 Climatic sequence 4.10.2 Dry heat Temperature: upper category temperature Duration: 16 h 4.10.3 Damp heat, cyclic, Test Db, first cycle 4.10.4 Cold Temperature: low
49、er category temperature Duration: 2 h 4.10.5 Low air pressure (if required by the detail specification) Air pressure: 8 kPa 4.10.5.3 Intermediate measurement Visual examination No permanent breakdown,flashover or harmful deformation of the case 4.10.6 Damp heat, cyclic, Test dB, remaining cycles 4.10.6.2 Final measurement Visual examina