1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI British StandardsWB9423_BSI_StandardColCov_noK_AW:BSI FRONT COVERS 5/9/08 12:55 Page 1Connectors forelectronic equipment Tests and measurements Part 16-3: Mechanical tests on contacts and termination
2、s Test 16c: Contact-bendingstrengthBS EN 60512-16-3:2008NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LANational forewordThis British Standard is the UK implementation of EN 60512-16-3:2008. Itis identical to IEC 60512-16-3:2008.The UK participation in its preparation was entrus
3、ted to TechnicalCommittee EPL/48, Electromechanical components and mechanical structures for electronic equipment.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisionsof a contract. U
4、sers are responsible for its correct application. BSI 200ISBN 978 0 580 55909 9ICS 31.220.10Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of the StandardsPolicy and Strategy Committee on Amendments issued since
5、 publicationAmd. No. Date Text affectedBRITISH STANDARDBS EN 60512-16-3:2008931 January 2009EUROPEAN STANDARD EN 60512-16-3 NORME EUROPENNE EUROPISCHE NORM September 2008 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komit
6、ee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2008 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 60512-16-3:2008 E ICS 31.220.10 English version Connectors for electronic equipment -
7、Tests and measurements - Part 16-3: Mechanical tests on contacts and terminations - Test 16c: Contact-bending strength (IEC 60512-16-3:2008) Connecteurs pour quipements lectroniques - Essais et mesures - Partie 16-3: Essais mcaniques des contacts et des sorties - Essai 16c: Tenue des contacts au pli
8、age (CEI 60512-16-3:2008) Steckverbinder fr elektronische Einrichtungen - Mess- und Prfverfahren - Teil 16-3: Mechanische Prfungen an Kontakten und Anschlssen - Prfung 16c: Biegefestigkeit von Kontakten (IEC 60512-16-3:2008) This European Standard was approved by CENELEC on 2008-08-01. CENELEC membe
9、rs are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on applicatio
10、n to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat ha
11、s the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherla
12、nds, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. BS EN 60512-16-3:2008- 3 - EN 60512-16-3:2008 Annex ZA (normative) Normative references to international publications with their corresponding European publications The following referenced
13、 documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE When an international publication has been modified by common modifi
14、cations, indicated by (mod), the relevant EN/HD applies. Publication Year Title EN/HD Year IEC 60512-1-1 - 1)Connectors for electronic equipment - Tests and measurements - Part 1-1: General examination - Test 1a: Visual examination EN 60512-1-1 2002 2)1)Undated reference. 2)Valid edition at date of
15、issue. BS EN 60512-16-3:2008 4 60512-16-3 IEC:2008 CONNECTORS FOR ELECTRONIC EQUIPMENT TESTS AND MEASUREMENTS Part 16-3: Mechanical tests on contacts and terminations Test 16c: Contact-bending strength 1 Scope and object This part of IEC 60512, when required by the detail specification, is used for
16、testing electrical connectors within the scope of technical committee 48. It may also be used for similar devices when specified in a detail specification. The object of this part of IEC 60512 is to detail a standard test method to determine the ability of a contact to withstand a specified bending
17、moment or force. If so specified in the detail specification, forces other than bending may be applied. Although this test is illustrated for the mating area of cylindrical contacts, and is particularly applicable to those with a mating diameter of 1,2 mm or less, its use for contacts with other geo
18、metries is not excluded. In which case, the detail specification shall contain sufficient detail, given under Clause 6, i), j) and k), to enable the test to be done. Furthermore, it may be used for any part of a connector (such as a keying or polarizing device; cable support or contact latching feat
19、ure) provided that sufficient detail is given in the detail specification. NOTE In some cases, IEC 60068-2-21 may be cited in the detail specification. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edi
20、tion cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 60512-1-1, Connectors for electronic equipment Tests and measurements Part 1-1: General examination Test 1a: Visual examination 3 Preparations 3.1 Preparation of specimen
21、 The specimen shall consist of a contact with its terminations, and may be wired if so specified in the detail specification. Any preconditioning given in the detail specification shall be applied. 3.2 Equipment For the application of the specified loads, a suitable device able to provide the contro
22、ls on the loads (intensity, rate of increase, time of constant load application) shall be required (e.g.: a universal materials testing machine). If the detail specification requires special preconditioning of the specimen, all the necessary equipment and process steps describing such conditioning s
23、hall be included. BS EN 60512-16-3:200860512-16-3 IEC:2008 5 4 Mounting If mounting of the specimen is appropriate, it shall be as specified in the detail specification. Figure 1 shows an example of mounting and clarifies details to be given in the detail specification. SpP M L 0,8L IEC 1004/08 Key
24、L Full engagement length of the contact under test P Point and direction of application of force SpPermanent set M Mounting or support means Figure 1 Contact bending (example) 5 Test method 5.1 General The specified bending moment or force shall be applied, at a specified rate until the specified va
25、lue is reached. This shall be maintained for 1 minute. The load shall then be removed. This procedure shall be applied at four points mutually at right angles to each other. For solid (e.g. turned) cylindrical contacts that are axi-symmetrical, only one procedure is necessary. If permanent set, exce
26、eding that allowed, results from the foregoing, a new sample shall be used. NOTE In the case of asymmetric (stamped and formed) contacts, more procedures should be performed choosing worst case positions.5.2 Measurements and requirements 5.2.1 Before testing Visual examination according to IEC 60512
27、-1-1 shall be carried out. BS EN 60512-16-3:2008 6 60512-16-3 IEC:2008 5.2.2 During testing The deflection and permanent set of the contact, measured at the point of application of that load shall be measured. NOTE In the case of a contact being made from a highly resilient material (e.g. spring ste
28、el or beryllium copper) the deflection may be large whilst the permanent set is negligible. The permanent set shall not exceed any value(s) given in the detail specification 5.2.3 After testing Visual examination according to IEC 60512-1-1 shall be carried out. 6 Details to be specified When this te
29、st is required by a detail specification, the following shall be given therein. a) if preconditioning is required; b) if the specimen is to be wired, if so details of this; c) if special mounting of the specimen is required; d) maximum force to be applied; e) point of application of force and relati
30、onship to mounting or support means; f) rate application of force; g) any allowable permanent set; h) number of specimens to be tested; i) if IEC 60068-2-21 is to be used; j) if the geometry of the contact requires special equipment, and if so, details of this; k) any deviation from the standard tes
31、t method. BS EN 60512-16-3:200860512-16-3 IEC:2008 7 Bibliography IEC 60068-2-21:2006, Environmental testing Part 2-21: Tests Test U: Robustness of terminations and integral mounting devices _ BS EN 60512-16-3:2008This page deliberately left blankBSI is the independent national body responsible for
32、preparing British Standards. It presents the UK view on standards in Europe and at the international level. It is incorporated by Royal Charter.British Standards Institution (BSI)raising standards worldwideBSI Group Headquarters389 Chiswick High Road London W4 4AL UKTel +44 (0)20 8996 9001Fax +44 (0
33、)20 8996 Standards are updated by amendment or revision. Users of BritishStandards should make sure that they possess the latest amendments oreditions.It is the constant aim of BSI to improve the quality of our products andservices. We would be grateful if anyone finding an inaccuracy orambiguity w
34、hile using this British Standard would inform the Secretary ofthe technical committee responsible, the identity of which can be foundon the inside front cover.Tel: +44 (0)20 8996 9000 Fax: +44 (0)20 8996 7400BSI offers members an individual updating service called PLUS whichensures that subscribers
35、automatically receive the latest editions ofstandards.Buying standardsOrders for all BSI, international and foreign standards publicationsshould be addressed to BSI Customer Services.Tel: +44 (0)20 8996 9001 Fax: +44 (0)20 8996 7001Email: You may also buy directly using a debit/credit card from the
36、BSI Shopon the website response to orders for international standards, it is BSI policy tosupply the BSI implementation of those that have been publishedas British Standards, unless otherwise requested.Information on standardsBSI provides a wide range of information on national, European andinterna
37、tional standards through its Library.Various BSI electronic information services are also available which givedetails on all its products and services. Contact the Information Centre. Tel: +44 (0)20 8996 7111 Fax: +44 (0)20 8996 7048 Email: Subscribing members of BSI are kept up to date with standar
38、dsdevelopments and receive substantial discounts on the purchase priceof standards. For details of these and other benefits contact MembershipAdministration. Tel: +44 (0)20 8996 7002 Fax: +44 (0)20 8996 7001 Email: Information regarding online access to British Standards via BritishStandards Online
39、 can be found at information about BSI is available on the BSI website CopyrightCopyright subsists in all BSI publications. BSI also holds the copyright, in the UK, of thepublications of the international standardization bodies. Except as permitted under theCopyright, Designs and Patents Act 1988 n
40、o extract may be reproduced, stored in a retrievalsystem or transmitted in any form or by any means electronic, photocopying, recording orotherwise without prior written permission from BSI. This does not preclude the free use, in the course of implementing the standard of necessarydetails such as s
41、ymbols, and size, type or grade designations. If these details are to be used forany other purpose than implementation then the prior written permission of BSI must beobtained. Details and advice can be obtained from the Copyright & Licensing Manager.Tel: +44 (0)20 8996 7070 Email: WB9423_BSI_StandardColCov_noK_AW:BSI FRONT COVERS 5/9/08 12:55 Page 2
copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有