1、BRITISH STANDARDBS EN 60684-3-233:2006Flexible insulating sleeving Part 3: Specifications for individual types of sleeving Sheet 233: Heat-shrinkable fluoroelastomer sleeving, flame retarded, fluid resistant, shrink ratio 2:1The European Standard EN 60684-3-233:2006 has the status of a British Stand
2、ardICS 29.035.20g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58BS EN 60684-3-233:2006This British Standard was published under the authority of the
3、 Standards Policy and Strategy Committee on 28 April 2006 BSI 2006ISBN 0 580 48081 XNational forewordThis British Standard is the official English language version of EN 60684-3-233:2006. It is identical with IEC 60684-3-233:2006. It supersedes BS EN 60684-3-233:1998 which is withdrawn.The UK partic
4、ipation in its preparation was entrusted to Technical Committee GEL/15, Standards on specifications for electrical insulating materials, which has the responsibility to: A list of organizations represented on this committee can be obtained on request to its secretary.Cross-referencesThe British Stan
5、dards which implement international or European publications referred to in this document may be found in the BSI Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online.This
6、 publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. aid enquirers to understand the text; present to the responsible inter
7、national/European committee any enquiries on the interpretation, or proposals for change, and keep UK interests informed; monitor related international and European developments and promulgate them in the UK.Summary of pagesThis document comprises a front cover, an inside front cover, the EN title p
8、age, pages 2 to 11 and a back cover.The BSI copyright notice displayed in this document indicates when the document was last issued.Amendments issued since publicationAmd. No. Date CommentsEUROPEAN STANDARD EN 60684-3-233 NORME EUROPENNE EUROPISCHE NORM March 2006 CENELEC European Committee for Elec
9、trotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2006 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref.
10、 No. EN 60684-3-233:2006 E ICS 29.035.20 Supersedes EN 60684-3-233:1998English version Flexible insulating sleeving Part 3: Specifications for individual types of sleeving Sheet 233: Heat-shrinkable fluoroelastomer sleeving, flame retarded, fluid resistant, shrink ratio 2:1 (IEC 60684-3-233:2006) Ga
11、ines isolantes souples Partie 3: Spcifications pour types particuliers de gaines Feuille 233: Gaines thermortractables en fluorolastomre, retardes la flamme, rsistant aux fluides, rapport de rtreint 2:1 (CEI 60684-3-233:2006) Isolierschluche Teil 3: Anforderungen fr einzelne Schlauchtypen Blatt 233:
12、 Fluorelastomer-Wrmeschrumpfschluche, flammwidrig, flssigkeitsbestndig, Schrumpfverhltnis 2:1 (IEC 60684-3-233:2006) This European Standard was approved by CENELEC on 2005-11-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving t
13、his European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versi
14、ons (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of
15、Austria, Belgium, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. Forewor
16、d The text of document 15/231/FDIS, future edition 2 of IEC 60684-3-233, prepared by IEC TC 15, Standards on specifications for electrical insulating materials, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 60684-3-233 on 2005-11-01. This European Standard supersed
17、es EN 60684-3-233:1998. The main change with regard to EN 60684-3-233:1998 concerns the replacement of the thermal endurance test, according to EN 60216, by a long-term ageing test, i.e. 3 000 h, at the maximum recommended temperature for such use, in order to furnish thermal test data within a work
18、able time frame. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2006-11-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2008
19、-11-01 This European Standard makes reference to International Standards. Where the International Standard referred to has been endorsed as a European Standard or a home-grown European Standard exists, this European Standard shall be applied instead. Pertinent information can be found on the CENELEC
20、 web site. _ Endorsement notice The text of the International Standard IEC 60684-3-233:2006 was approved by CENELEC as a European Standard without any modification. _ EN 60684-3-233:2006 2 3 CONTENTS INTRODUCTION 4 1 Scope 5 2 Normative references .5 3 Designation6 4 Conditions of test .6 5 Requirem
21、ents.6 6 Sleeving conformance 6 7 Breakdown voltage .10 Table 1 Type A Dimensional and mass requirements7 Table 2 Type B Dimensional and mass requirements7 Table 3 Property requirements.8 Table 4 Requirements for breakdown voltage.10 Table 5 Resistance to selected fluids .11 Table 6 Additional prope
22、rty requirements .11 EN 60684-3-233:2006 4 INTRODUCTION This International Standard is one of a series which deals with flexible insulating sleeving for electrical purposes. The series consists of three parts: Part 1: Definitions and general requirements (IEC 60684-1) Part 2: Methods of test (IEC 60
23、684-2) Part 3: Specifications for individual types of sleeving (IEC 60684-3) This standard gives one of the sheets comprising part 3 as follows: Sheet 233: Heat-shrinkable fluoroelastomer sleeving, flame retarded, fluid resistant, shrink ratio 2:1. EN 60684-3-233:2006 5 FLEXIBLE INSULATING SLEEVING
24、Part 3: Specifications for individual types of sleeving Sheet 233: Heat-shrinkable fluoroelastomer sleeving, flame retarded, fluid resistant, shrink ratio 2:1 1 Scope This standard gives the requirements for two types of heat-shrinkable, flame retarded, fluid resistant1), nominal shrink ratio 2:1, f
25、luoroelastomer sleeving for use at temperatures up to 200 C: Type A: thick wall; Type B: thin wall. These sleevings are normally supplied with internal diameters up to 51 mm, and the standard colour is black. Sizes or colours other than those specifically listed in this standard may be available as
26、custom items. These items shall be considered to comply with this standard if they comply with the property requirements listed in Tables 3, 4, 5 and 6 except for . dimensions and mass Materials which conform to this specification meet established levels of performance. However, the selection of a m
27、aterial by a user for a specific application should be based on the actual requirements necessary for adequate performance in that application and not based on this specification alone 2 Normative references The following referenced documents are indispensable for the application of this document. F
28、or dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 60684-1:2003, Flexible insulating sleeving Part 1: Definitions and general requirements IEC 60684-2.1:1997, Flexible insulating sleeving
29、Part 2: Methods of test Amendment (2003) IEC 60757:1983, Code for designation of colours ISO 846:1997, Plastics Evaluation of the action of micr-organisms ISO 1817:1999, Rubber, vulcanized Determination of the effect of liquids _ 1)Except to phosphate ester-based hydraulic fluids. EN 60684-3-233:200
30、6 6 3 Designation The sleeving shall be identified by the following designation: Description IEC publication number IEC Part number IEC sheet number Type Size (expanded and recovered internal diameter in mm) Colour Sleeving IEC 60684 - 3 -233 -A - 12,7/6,4 - BK Any colour abbreviation shall comply w
31、ith IEC 60757, where applicable. Non-standard colours shall be written out in full. 4 Conditions of test Unless otherwise specified, the sleeving shall be shrunk in a forced air circulation oven for (5 1) min at 200 C 5 K prior to testing. 5 Requirements In addition to the general requirements given
32、 in IEC 60684-1, the sleeving shall comply with the requirements of Tables 1, 2, 3, 4, 5 and 6. 6 Sleeving conformance Product conformance shall normally be based on the results from size 12,7/6,4 mm black sleeving. The colour fastness to light shall be qualified for all colours. EN 60684-3-233:2006
33、 7 Table 1 Type A dimensional and mass requirements Internal diameter mm Size code Expanded min. Recovered max. Recovered wall thickness mm Mass per unit length g/m Max. 3,2 / 1,6 3,2 1,6 0,75 0,15 13,8 4,8 / 2,4 4,8 2,4 0,85 0,20 22,2 6,4 / 3,2 6,4 3,2 0,90 0,20 29,0 9,5 / 4,8 9,5 4,8 1,00 0,20 44,
34、1 12,7 / 6,4 12,7 6,4 1,20 0,30 72,6 19,0 / 9,5 19,0 9,5 1,45 0,35 125 25,4 / 12,7 25,4 12,7 1,80 0,45 206 38,0 / 19,0 38,0 19,0 2,40 0,50 389 51,0 / 25,4 51,0 25,4 2,80 0,50 580 Table 2 Type B dimensional and mass requirements Internal diameter mm Size code Expanded min. Recovered max. Recovered wa
35、ll thickness mm Mass per unit length g/m Max. 3,2 / 1,6 3,2 1,6 0,90 0,20 20,5 4,8 / 2,4 4,8 2,4 0,90 0,20 26,6 6,4 / 3,2 6,4 3,2 0,90 0,20 32,7 9,5 / 4,8 9,5 4,8 0,90 0,20 44,8 12,7 / 6,4 12,7 6,4 0,90 0,20 57,0 19,0 / 9,5 19,0 9,5 1,10 0,20 97,0 25,4 / 12,7 25,4 12,7 1,20 0,30 147 38,0 / 19,0 38,0
36、 19,0 1,40 0,40 259 51,0 / 25,4 51,0 25,4 1,70 0,40 409 76,2/38,1 76,2 38,1 1,70 0,40 600 EN 60684-3-233:2006 8 Table 3 Property requirements Property IEC 60684-2 Clause or subclause Units Max. or min. Requirements Remarks Dimensions internal diameter wall thickness concentricity expanded recovered
37、3 3.1.2 3.3.2 3.3.3 mm mm % Min. Tables 1 and 2 Tables 1 and 2 65 85 Heat shock Tensile strength Elongation at break 6 19.1 and 19.2 19.1 and 19.2 MPa % Min. Min. 8 150 Heat at 300 C 5 K Longitudinal change 9 % Max. 20 Heat the expanded sleeving at 200 C 5 K for (15 1) min Bending at low temperature
38、 14 There shall be no signs of cracking Test temperature 55 C 3 K. For strips, the mandrel shall be no more than 20 times the wall thickness. Full section sleeving is tested unfilled and the mandrel shall be no more than 20 times the outer diameter Dimensional stability on storage 16 The dimensions
39、shall be as specified in Tables 1 and 2 Tensile strength Elongation at break 19.1 and 19.2 19.1 and 19.2 MPa % Min. Min. 8,2 250 Rate of jaw separation 100 mm/min. Below 6,5 mm diameter as sleeving; at 6,5 mm diameter and above as dumb-bells Secant modulus at 2 % elongation 19.4 MPa MPa Min. Max. 30
40、 100 Breakdown voltage 21 kV Min. Table 4 Volume resistivity at room temperature after damp heat 23 23.4.2 23.4.4 m m Min. Min. 1010109Flame propagation Time of burning Length burned 26 Method C s mm Max. Max. 30 75 EN 60684-3-233:2006 9 Table 3 (continued) Property IEC 60684-2 Clause or subclause U
41、nits Max. or min. Requirements Remarks Copper corrosion 33 % Max. None above the allowable 8 % Heat for (16 0,5) h at 175 C 3 K Colour fastness to light 34 The colour contrast between the exposed and unexposed parts of the specimens shall be equal to or less than that of the fastness standard Fastne
42、ss standard No. 5Resistance to selected fluids Tensile strength Elongation at break 36 19.1 and 19.2 19.1 and 19.2 MPa % Min. Min. 8 200 Use the fluids and test temperatures specified in Table 5 Mass per unit length 38 g/m Max. Tables 1 and 2 Heat ageing Tensile strength Elongation at break 39 19.1
43、and 19.2 19.1 and 19.2 MPa % Min. Min. 8,2 150 Heat at 250 C 5 K Water absorption 40 % Max. 1,0 Long term ageing Elongation 50 19.1 and 19.2 % Min 125 ; The ageing temperature shall be 200 C 5K EN 60684-3-233:2006 10 7 Breakdown voltage The breakdown voltage shall be determined by any of the methods
44、 described in 21.2, 21.3 or 21.4 of IEC 60684-2. The central value shall comply with the minimum value in this table. The rate of application of the voltage shall be 500 V/s. Table 4 Requirements for breakdown voltage Nominal recovered wall thickness* mm Breakdown voltage min. kV 0,75 0,85 0,90 1,00
45、 1,10 1,20 1,40 1,45 1,70 1,80 2,40 2,80 4,5 5,0 5,5 6,0 6,5 7,0 8,5 8,5 10,0 11,0 14,5 17,0 * For non-standard wall thicknesses, the electric strength shall be at least that of the next smallest standard wall thickness. For wall thicknesses smaller than 0,75 mm, the electric strength shall be at le
46、ast 6,0 kV/mm. EN 60684-3-233:2006 11 Table 5 Resistance to selected fluids Fluids Type Standard or symbol Immersion temperature C 2 K Gasoline ISO 1817 Liquid B 23 Fuels Kerosene ISO 1817 Liquid F 70 Silicone base S-1714* 70 Hydraulic fluids Mineral base H-520* 50 Synthetic base ISO 1817 Liquid 101
47、 70 Mineral base ISO 1817 Oil no. 2 70 Mineral base O-1176* 70 Oils Mineral base O-142* 50 Isopropyl alcohol 23 Cleaning fluids Solvent Propanol 25 % White spirit 75 % 23 Runway de-icers Inhibited potassium acetate in water, 50 % 23 De-icing fluids Aircraft de-icers Ethylene glycol 80 % Water 20 % 2
48、3 * These are commercially available fluids which can be identified in aviation fluid guides. NOTE Other fluids and/or temperatures may be specified with specific needs. These additional fluids and/or temperatures should be applicable when incorporated into agreements between the supplier and custom
49、er. Table 6 Additional property requirements Property IEC 60684-2 subclause Units Max. or min. Requirements Remarks Fungus resistance Tensile strength Elongation at break 19.1 and 19.2 19.1 and 19.2 MPa % Min. Min. 10,5 250 The test method shall be ISO 846, method B. 56 days exposure Shelf life* The dimensions shall be as specified in Tables 1 and 2