1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationElectric and optical fibre cables Test methods for non-metallic materialsPart 513: Mechanical tests Methods specific to polyethylene and polypropylene compounds Wrapping test aft
2、er conditioningBS EN 60811-513:2012National forewordThis British Standard is the UK implementation of EN 60811-513:2012. It isidentical to IEC 60811-513:2012.In the UK, the relationship between the supersessions of BS EN 60811 seriescan be summarized as follows.Superseded standards are withdrawnThe
3、UK participation in its preparation was entrusted by Technical CommitteeGEL/20, Electric cables, to Subcommittee GEL/20/17, Electric Cables - Lowvoltage.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all t
4、he necessary provisions of acontract. Users are responsible for its correct application. The British Standards Institution 2012Published by BSI Standards Limited 2012ISBN 978 0 580 65337 7ICS 29.035.01; 29.060.20Compliance with a British Standard cannot confer immunity fromlegal obligations.This Bri
5、tish Standard was published under the authority of the StandardsPolicy and Strategy Committee on 31 July 2012.Amendments issued since publicationAmd. No. Date Text affectedBRITISH STANDARDBS EN 60811-513:2012BS EN 60811-100 together with Supersedes - -201, -202, -203, -501 BS EN 60811-1-1:1995 -301,
6、 -302, -411, -601, -602, -603, -604 BS EN 60811-5-1:2000 -401, -412 BS EN 60811-1-2:1995 -402, -502, -503, -606 BS EN 60811-1-3:1995 -403, -404, -507 BS EN 60811-2-1:1998 -405, -409 BS EN 60811-3-2:1995 -406, -511, -605, -607 BS EN 60811-4-1:2004 -407, -408, -410, -510, -512, -513 BS EN 60811-4-2:20
7、04 -504, -505, -506 BS EN 60811-1-4:1995 -508, -509 BS EN 60811-3-1:1995EUROPEAN STANDARD EN 60811-513 NORME EUROPENNE EUROPISCHE NORM June 2012 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische No
8、rmung Management Centre: Avenue Marnix 17, B - 1000 Brussels 2012 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 60811-513:2012 E ICS 29.035.01; 29.060.20 Supersedes EN 60811-4-2:2004 (partially)English version Electric and optic
9、al fibre cables - Test methods for non-metallic materials - Part 513: Mechanical tests - Methods specific to polyethylene and polypropylene compounds - Wrapping test after conditioning (IEC 60811-513:2012) Cbles lectriques et fibres optiques - Mthodes dessai pour les matriaux non-mtalliques - Partie
10、 513: Essais mcaniques - Mthodes spcifiques pour les mlanges polythylne et polypropylne - Essai denroulement aprs conditionnement (CEI 60811-513:2012) Kabel, isolierte Leitungen und Glasfaserkabel - Prfverfahren fr nichtmetallene Werkstoffe - Teil 513: Mechanische Prfungen - Verfahren speziell fr Po
11、lyethylen- und Polypropylenmischungen - Wickelprfung nach Vorbehandlung (IEC 60811-513:2012) This European Standard was approved by CENELEC on 2012-04-17. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard th
12、e status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member. This European Standard exists in three official versions (English,
13、French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CENELEC members are the national electrotechnical committees of Aust
14、ria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the
15、United Kingdom. EN 60811-513:2012 - 2 - Foreword The text of document 20/1309/FDIS, future edition 1 of IEC 60811-513, prepared by IEC/TC 20 “Electric cables“ was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as EN 60811-513:2012. The following dates are fixed: latest date by wh
16、ich the document has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2013-01-17 latest date by which the national standards conflicting with the document have to be withdrawn (dow) 2015-04-17 This document supersedes Clause 9 of EN 60811-4
17、-2:2004 (partially). Full details of the replacements are shown in Annex A of EN 60811-100:2012. There are no specific technical changes with respect to EN 60811-4-2:2004, but see the Foreword to EN 60811-100:2012. This standard is to be read in conjunction with EN 60811-100. Attention is drawn to t
18、he possibility that some of the elements of this document may be the subject of patent rights. CENELEC and/or CEN shall not be held responsible for identifying any or all such patent rights. This standard covers the Principle Elements of the Safety Objectives for Electrical Equipment Designed for Us
19、e within Certain Voltage Limits (LVD - 2006/95/EC). Endorsement notice The text of the International Standard IEC 60811-513:2012 was approved by CENELEC as a European Standard without any modification. In the official version, for Bibliography, the following notes have to be added for the standards
20、indicated: IEC 60811-4-2:2004 NOTE Harmonized as EN 60811-4-2:2004 (not modified). IEC 60811-601 NOTE Harmonized as EN 60811-601. BS EN 60811-513:2012- 3 - EN 60811-513:2012 Annex ZA (normative) Normative references to international publications with their corresponding European publications The fol
21、lowing documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE When an i
22、nternational publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. Publication Year Title EN/HD Year IEC 60811-100 2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 100: General EN 60811-100 2012 BS EN 60811-513:2
23、012 2 60811-513 IEC:2012 CONTENTS 1 Scope . 6 2 Normative references . 6 3 Terms and definitions . 6 4 Test method . 6 4.1 General . 6 4.2 Conditioning procedure . 6 4.3 Test procedure 7 4.4 Evaluation of results 7 5 Test report 7 Bibliography 8 BS EN 60811-513:201260811-513 IEC:2012 5 INTRODUCTION
24、The IEC 60811 series specifies the test methods to be used for testing non-metallic materials of all types of cables. These test methods are intended to be referenced in standards for cable construction and for cable materials. NOTE 1 Non-metallic materials are typically used for insulating, sheathi
25、ng, bedding, filling or taping within cables. NOTE 2 These test methods are accepted as basic and fundamental and have been developed and used over many years principally for the materials in all energy cables. They have also been widely accepted and used for other cables, in particular optical fibr
26、e cables, communication and control cables and cables for ships and offshore applications. BS EN 60811-513:2012 6 60811-513 IEC:2012 ELECTRIC AND OPTICAL FIBRE CABLES TEST METHODS FOR NON-METALLIC MATERIALS Part 513: Mechanical tests Methods specific to polyethylene and polypropylene compounds Wrapp
27、ing test after conditioning 1 Scope This Part 513 of IEC 60811 gives procedures for a wrapping test after conditioning at elevated temperature. This test method applies specifically to polyethylene and polypropylene insulation. This test is intended for samples from filled cables of polyolefin insul
28、ation having a wall thickness of less than or equal to 0,8 mm. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the
29、 latest edition of the referenced document (including any amendments) applies. IEC 60811-100:2012, Electric and optical fibre cables Test methods for non-metallic materials Part 100: General 3 Terms and definitions For the purposes of this document, the terms and definitions given in IEC 60811-100 a
30、pply. 4 Test method 4.1 General This part of IEC 60811 shall be used in conjunction with IEC 60811-100. For multicore cables and cords, not more than three cores (of different colours, if any) shall be tested, unless otherwise specified in the relevant cable standard. All the tests shall be carried
31、out not less than 16 h after the extrusion or cross-linking, if any, of the compounds used for insulating or sheathing. 4.2 Conditioning procedure A sample of complete cable of sufficient length shall be conditioned in air (i.e. suspended in an oven). The duration of the test and temperature of the
32、air maintained continuously shall be as follows: 7 24 h at (60 2) C for filling compound having a nominal drop point above 50 C and up to and including 70 C; 7 24 h at (70 2) C for filling compound having a nominal drop point above 70 C. BS EN 60811-513:201260811-513 IEC:2012 7 NOTE For an explanati
33、on of the drop point, see IEC 60811-601. After conditioning, the cable sample shall be left at ambient temperature for at least 16 h without being exposed to direct sunlight. The sheath and cores to be tested shall then be taken from the cable and shall be cleaned by suitable means. 4.3 Test procedu
34、re Test pieces according to 4.2 shall be subjected to the following wrapping test: The conductor shall be laid bare at one end. A weight shall be applied to the exposed conductor end, exerting a pull of 15 N/mm2 20 % with respect to the conductor cross-section. Ten windings shall be made on the othe
35、r end of the test piece by means of a winding device on a metal mandrel, preferably mechanically driven, at a speed of about 1 revolution per 5 s. The winding diameter shall be 1 to 1,5 times the test piece diameter. Subsequently, the test pieces wound on the mandrel shall be removed from the latter
36、 and shall be kept in their helical form for 24 h at (70 2) C in a vertical position, substantially in the middle of an electrically heated cabinet having natural air flow. For cellular insulations, including foam skin, having a wall thickness below or equal to 0,2 mm, the pull exerted on the expose
37、d conductor shall be reduced to about 7,5 N/mm2 20 % with respect to the conductor cross-section. 4.4 Evaluation of results After cooling down to ambient temperature, the test pieces shall show no cracks when examined with normal or corrected vision without magnification. The test may be repeated on
38、ce only if one test piece fails. 5 Test report The test report shall be in accordance with that given in IEC 60811-100. BS EN 60811-513:2012 8 60811-513 IEC:2012 Bibliography IEC 60811-4-2:2004, Insulating and sheathing materials of electric and optical cables Common test methods Part 4-2: Methods s
39、pecific to polyethylene and polypropylene compounds Tensile strength and elongation at break after conditioning at elevated temperature Wrapping test after conditioning at elevated temperature Wrapping test after thermal ageing in air Measurement of mass increase Long-term stability test Test method
40、 for copper-catalyzed oxidative degradation (withdrawn) IEC 60811-601, Electric and optical fibre cables Test methods for non-metallic materials Part 601: Physical tests Measurement of the drop point of filling compounds _ BS EN 60811-513:2012This page deliberately left blankBSI is the independent n
41、ational body responsible for preparing British Standards and other standards-related publications, information and services. It presents the UK view on standards in Europe and at the international level. BSI is incorporated by Royal Charter. British Standards and other standardisation products are p
42、ublished by BSI Standards Limited.British Standards Institution (BSI)raising standards worldwideBSI389 Chiswick High Road London W4 4AL UKTel +44 (0)20 8996 9001Fax +44 (0)20 8996 Standards and PASs are periodically updated by amendment or revision. Users of British Standards and PASs should make s
43、ure that they possess the latest amendments or editions.It is the constant aim of BSI to improve the quality of our products and services. We would be grateful if anyone finding an inaccuracy or ambiguity while using British Standards would inform the Secretary of the technical committee responsible
44、, the identity of which can be found on the inside frontcover. Similary for PASs, please notify BSI Customer Services.Tel: +44 (0)20 8996 9001 Fax: +44 (0)20 8996 7001BSI offers BSI Subscribing Members an individual updating service called PLUS which ensures that subscribers automatically receive th
45、e latest editions of British Standards and PASs.Tel: +44 (0)20 8996 7669 Fax: +44 (0)20 8996 7001Email: Buying standardsYou may buy PDF and hard copy versions of standards directly using acredit card from the BSI Shop on the website addition all orders for BSI, international and foreign standards p
46、ublicationscan be addressed to BSI Customer Services.Tel: +44 (0)20 8996 9001 Fax: +44 (0)20 8996 7001Email: In response to orders for international standards, BSI will supply the British Standard implementation of the relevant international standard, unless otherwise requested.Information on standa
47、rdsBSI provides a wide range of information on national, Europeanand international standards through its Knowledge Centre.Tel: +44 (0)20 8996 7004 Fax: +44 (0)20 8996 7005Email: BSI Subscribing Members are kept up to date with standards developments and receive substantial discounts on the purchase
48、priceof standards. For details of these and other benefits contact Membership Administration. Tel: +44 (0)20 8996 7002 Fax: +44 (0)20 8996 7001 Email: Information regarding online access to British Standards and PASs via British Standards Online can be found at information about British Standards is available on the BSI website at www.bsi- the data, software and documentation set out in all British Standards and other BSI publications are the property of and copyrighted by BSI, or some person or entity that own copyri