1、BSI Standards PublicationFibre optic interconnecting devices and passive components Fibre optic spatial switchesPart 1: Generic specificationBS EN 60876-1:2014National forewordThis British Standard is the UK implementation of EN 60876-1:2014. It is identical to IEC 60876-1:2014. It supersedes BS EN
2、60876-1:2012 which is withdrawn.The UK participation in its preparation was entrusted by TechnicalCommittee GEL/86, Fibre optics, to Subcommittee GEL/86/2, Fibre opticinterconnecting devices and passive components.A list of organizations represented on this committee can be obtained onrequest to its
3、 secretary.This publication does not purport to include all the necessary provisions ofa contract. Users are responsible for its correct application. The British Standards Institution 2014.Published by BSI Standards Limited 2014ISBN 978 0 580 84037 1ICS 33.180.20Compliance with a British Standard ca
4、nnot confer immunity fromlegal obligations.This British Standard was published under the authority of theStandards Policy and Strategy Committee on 31 October 2014.Amendments/corrigenda issued since publicationDate Text affectedBRITISH STANDARDBS EN 60876-1:2014EUROPEAN STANDARDNORME EUROPENNEEUROPI
5、SCHE NORMEN 60876-1 October 2014 ICS 33.180.20 Supersedes EN 60876-1:2012 English Version Fibre optic interconnecting devices and passive components - Fibre optic spatial switches - Part 1: Generic specification (IEC 60876-1:2014) Dispositifs dinterconnexion et composants passifs fibresoptiques - Co
6、mmutateurs spatiaux fibres optiquesPartie 1: Spcification gnrique (CEI 60876-1:2014) Lichtwellenleiter - Verbindungselemente und passiveBauteile - Rumliche Umschalter fr Lichtwellenleiter Teil 1: Fachgrundspezifikation (IEC 60876-1:2014) This European Standard was approved by CENELEC on 2014-09-26.
7、CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained
8、on application to the CEN-CENELEC Management Centre or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the
9、 CEN-CENELEC Management Centre has the same status as the official versions.CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hung
10、ary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechniq
11、ueEuropisches Komitee fr Elektrotechnische Normung CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2014 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members. Ref. No. EN 60876-1:2014 E EN 60876-1:2014 - 2 - Foreword The text of docum
12、ent 86B/3713/CDV, future edition 5 of IEC 60876-1, prepared by SC 86B “Fibre optic interconnecting devices and passive components” of IEC/TC 86 “Fibre optics” was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as EN 60876-1:2014. The following dates are fixed: latest date by whic
13、h the document has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2015-06-26 latest date by which the national standards conflicting with the document have to be withdrawn (dow) 2017-09-26 This document supersedes EN 60876-1:2012 Attentio
14、n is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC and/or CEN shall not be held responsible for identifying any or all such patent rights. Endorsement notice The text of the International Standard IEC 60876-1:2014 was approved by CEN
15、ELEC as a European Standard without any modification. In the official version, for Bibliography, the following notes have to be added for the standards indicated: IEC 60410 NOTE Harmonised as EN 60410 IEC 60869-1 NOTE Harmonised as EN 60869-1 IEC 61073-1 NOTE Harmonised as EN 61073-1 BS EN 60876-1:2
16、014- 3 - EN 60876-1:2014 Annex ZA (normative) Normative references to international publications with their corresponding European publications The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, o
17、nly the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE 1 When an International Publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. NOTE 2 Up-to-date information o
18、n the latest versions of the European Standards listed in this annex is available here: www.cenelec.eu. Publication Year Title EN/HD Year IEC 60027 Series Letter symbols to be used in electrical technology EN 60027 Series IEC 60050-731 - International Electrotechnical Vocabulary (IEV) Chapter 731: O
19、ptical fibre communication - - IEC 60617 Series Standard data element types with associated classification scheme for electric components - Series IEC 60695-11-5 - Fire hazard testing Part 11-5: Test flames - Needle-flame test method - Apparatus, confirmatory test arrangement and guidance EN 60695-1
20、1-5 - IEC 60825-1 - Safety of laser products Part 1: Equipment classification and requirements EN 60825-1 - IEC 61300 Series Fibre optic interconnecting devices and passive components - Basic test and measurement procedures EN 61300 Series IEC/TR 61930 - Fibre optic graphical symbology - - IEC 62047
21、-1 - Semiconductor devices - Micro-electromechanical devices Part 1: Terms and definitions EN 62047-1 - ISO 129-1 - Technical drawings - Indication of dimensions and tolerances Part 1: General principles - - ISO 286-1 - Geometrical product specifications (GPS) - ISO code system for tolerances on lin
22、ear sizes Part 1: Basis of tolerances, deviations and fits EN ISO 286-1 - ISO 1101 - Geometrical product specifications (GPS) - Geometrical tolerancing - Tolerances of form, orientation, location and run-out EN ISO 1101 - ISO 8601 - Data elements and interchange formats - Information interchange - R
23、epresentation of dates and times - - BS EN 60876-1:2014 2 IEC 60876-1:2014 IEC 2014 CONTENTS 1 Scope 6 2 Normative references. 6 3 Terms and definitions 7 3.1 Basic terms and definitions 7 3.2 Component definitions . 8 3.3 Performance parameter definitions 9 4 Requirements 12 4.1 Classification 12 G
24、eneral . 12 4.1.1Type 13 4.1.2Style 16 4.1.3Variant . 17 4.1.4Normative reference extension . 17 4.1.54.2 Documentation 18 Symbols . 18 4.2.1Specification system 18 4.2.2Drawings . 20 4.2.3Test and measurement . 20 4.2.4Test reports . 21 4.2.5Instructions for use 21 4.2.64.3 Standardization system .
25、 21 Interface standards 21 4.3.1Performance standards 21 4.3.2Reliability standards . 22 4.3.3Interlinking . 22 4.3.44.4 Design and construction 24 Materials 24 4.4.1Workmanship . 24 4.4.24.5 Quality 24 4.6 Performance . 24 4.7 Identification and marking 24 General . 24 4.7.1Variant identification n
26、umber 24 4.7.2Component marking . 25 4.7.3Package marking . 25 4.7.44.8 Packaging . 25 4.9 Storage conditions 25 4.10 Safety . 25 Annex A (informative) Example of magneto-optic effect (MO) switch technologies . 27 Annex B (informative) Example of mechanical switch technologies 28 Annex C (informativ
27、e) Example of micro-electromechanical system (MEMS) switch technologies . 29 Annex D (informative) Example of thermo-optic effect (TO) technologies . 30 Annex E (informative) Summary of definitions on switching time . 33 Bibliography . 34 BS EN 60876-1:2014IEC 60876-1:2014 IEC 2014 3 Figure 1 Repres
28、entation of latency time, rise time, fall time, bounce time and switching time 12 Figure 2 Single-pole, single-throw switch 14 Figure 3 Transfer matrix for one input port and one output port . 14 Figure 4 Single-pole, throw switch 14 Figure 5 Transfer matrix for one input port and N output ports . 1
29、4 Figure 6 N-port matrix switch 15 Figure 7 Transfer matrix for N-ports switch . 15 Figure 8 Four-port switch without crossover 16 Figure 9 Four-port switch with crossover 16 Figure 10 Configuration A, a device containing integral fibre optic pigtails without connectors 17 Figure 11 Configuration B,
30、 a device containing integral fibre optic pigtails, with a connector on each pigtail 17 Figure 12 Configuration C, a device containing a fibre optic connector as an integral part of the device housing . 17 Figure 13 Standards 23 Figure A.1 Example of 12 MO switch 27 Figure B.1 Example of mechanical
31、switch (mirror driving type) 28 Figure B.2 Example of mechanical switch (fibre driving type) 28 Figure C.1 Example of MEMS switch 29 Figure D.1 Example of TO switch . 30 Figure D.2 Output power of TO switch 31 Figure D.3 Example of switching response of TO switch . 31 Figure D.4 1 N and N N examples
32、 of TO switch . 32 Table 1 Example of a typical switch classification . 13 Table 2 Transfer matrix of a four-port switch without crossover . 15 Table 3 Transfer matrix of a four-port switch with crossover 16 Table 4 IEC specification structure . 19 Table 5 Standards interlink matrix 24 Table E.1 Sum
33、mary of definitions of latency time 33 Table E.2 Summary of the definitions of rise time . 33 Table E.3 Summary of the definitions of fall time 33 BS EN 60876-1:2014 6 IEC 60876-1:2014 IEC 2014 FIBRE OPTIC INTERCONNECTING DEVICES AND PASSIVE COMPONENTS IBRE OPTIC SPATIAL SWITCHES Part 1: Generic spe
34、cification 1 Scope This part of IEC 60876 applies to fibre optic switches possessing all of the following general features: they are passive in that they contain no optoelectronic or other transducing elements; they have one or more ports for the transmission of optical power and two or more states
35、in which power may be routed or blocked between these ports; the ports are optical fibres or fibre optic connectors. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only
36、the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 60027 (all parts), Letter symbols to be used in electrical technology IEC 60050-731, International Electrotechnical Vocabulary Chapter 731: Optical fibre communica
37、tion IEC 60617 (all parts), Graphical symbols for diagrams (available at ) IEC 60695-11-5, Fire hazard testing Part 11-5: Test flames Needle-flame test method Apparatus, confirmatory test arrangement and guidance IEC 60825-1, Safety of laser products Part 1: Equipment classification and requirements
38、 IEC 61300 (all parts), Fibre optic interconnecting devices and passive components Basic test and measurement procedures IEC TR 61930, Fibre optic graphical symbology IEC 62047-1, Semiconductor devices Micro-electromechanical devices Part 1: Terms and definitions ISO 129-1, Technical drawings Indica
39、tion of dimensions and tolerances Part 1: General principles ISO 286-1, Geometrical product specifications (GPS) ISO code system for tolerances on linear sizes Part 1: Basis of tolerances, deviations and fits BS EN 60876-1:2014IEC 60876-1:2014 IEC 2014 7 ISO 1101, Geometrical product specifications
40、(GPS) Geometrical tolerancing Tolerances of form, orientation, location and run-out ISO 8601, Data elements and interchange formats Information interchange Representation of dates and times 3 Terms and definitions For the purposes of this document, the terms and definitions given in IEC 60050-731, t
41、ogether with the following, apply. 3.1 Basic terms and definitions 3.1.1port optical fibre or fibre optic connector attached to a passive component for the entry and/or exit of optical power 3.1.2transfer matrix optical properties of a fibre optic switch can be defined in a n n matrix of coefficient
42、s (n is the number of ports) Note 1 to entry: The T matrix represents the on-state paths (worst-case transmission) and the T matrix represents the off-state paths (worst-case isolation). 3.1.3transfer coefficient element tijor tijof the transfer matrix Note 1 to entry: Each transfer coefficient tiji
43、s the worst-case (minimum) fraction of power transferred from port i to port j for any state with path ij switched on. Each coefficient tijis the worst-case (maximum) fraction of power transferred from port i to port j for any state with path ij switched off. 3.1.4logarithmic transfer matrix aij= 10
44、 log10tijwhere aijis the optical power reduction in decibels out of port j with unit power into port i, i.e. tijis the transfer coefficient Note 1 to entry: Similarly, for the off state, aij = 10 log10tij. 3.1.5switch state particular optical configuration of a switch, whereby optical power is trans
45、mitted or blocked between specific ports in a predetermined manner 3.1.6actuation mechanism physical means (mechanical, electrical, acoustic, optical, etc.) by which a switch is designed to change between states 3.1.7actuation energy input energy required to place a switch in a specific state BS EN
46、60876-1:2014 8 IEC 60876-1:2014 IEC 2014 3.1.8blocking inability to establish a connection from a free input port to a free output port due to the existence of some other established connection Note 1 to entry: Blocking and various degrees of non-blocking operation functionalities are of various typ
47、es: “Strict-sense non-blocking” refers to a switch matrix in which it is always possible to establish a connection between any free input port and any free output port, irrespective of previously established connections. “Wide-sense non-blocking” refers to a matrix in which it is always possible to
48、establish a desired connection provided that some systematic procedure is followed in setting up connections. Some multistage switching architectures fall into this category. “Rearrangeably non-blocking” refers to a switch matrix in which any free input port can be connected to any free output port
49、provided that other established connections are unconnected and then reconnected as part of making the new connection. 3.1.9normally on condition where a port pair is in a conducting state when there is no actuation energy applied for a non-latching switch 3.1.10normally off condition where a port pair is in an isolated state when there is no actuation energy applied for a non-latching switch 3.2