1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationSelf-ballasted lamps for general lighting services Safety requirementsBS EN 60968:2013Copyright European Committee for Electrotechnical Standardization Provided by IHS under lice
2、nse with CENELECNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-National forewordThis British Standard is the UK implementation of EN 60968:2013. It is identical to IEC 60968:2012. It supersedes BS EN 60968:2000 which is withdrawn.The UK participation in its prepar
3、ation was entrusted by Technical Committee CPL/34, Lamps and Related Equipment, to Subcommittee CPL/34/1, Electric lamps.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a co
4、ntract. Users are responsible for its correct application. The British Standards Institution 2013.Published by BSI Standards Limited 2013 ISBN 978 0 580 77737 0 ICS 29.140.30 Compliance with a British Standard cannot confer immunity from legal obligations.This British Standard was published under th
5、e authority of the Standards Policy and Strategy Committee on 28 February 2013.Amendments issued since publicationDate Text affectedBRITISH STANDARDBS EN 60968:2013Copyright European Committee for Electrotechnical Standardization Provided by IHS under license with CENELECNot for ResaleNo reproductio
6、n or networking permitted without license from IHS-,-,-EUROPEAN STANDARD EN 60968 NORME EUROPENNE EUROPISCHE NORM January 2013 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Management C
7、entre: Avenue Marnix 17, B - 1000 Brussels 2013 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 60968:2013 E ICS 29.140.30 Supersedes EN 60968:1990 + A1:1993 + A2:1999 English version Self-ballasted lamps for general lighting serv
8、ices - Safety requirements (IEC 60968:2012) Lampes ballast intgr pour lclairage gnral - Exigences de scurit (CEI 60968:2012) Lampen mit eingebautem Vorschaltgert fr Allgemeinbeleuchtung - Sicherheitsanforderungen (IEC 60968:2012) This European Standard was approved by CENELEC on 2012-10-31. CENELEC
9、members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on appli
10、cation to the CEN-CENELEC Management Centre or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the CEN-CEN
11、ELEC Management Centre has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Ic
12、eland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 60968:2013Copyright European Committee for Electrotechnical Standardization Provided by IHS under lice
13、nse with CENELECNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-EN 60968:2013 - 2 - Foreword The text of document 34A/1540/CDV, future edition 2 of IEC 60968, prepared by SC 34A “Lamps“ of IEC/TC 34A “Lamps and related equipment“ was submitted to the IEC-CENELEC pa
14、rallel vote and approved by CENELEC as EN 60968:2013. The following dates are fixed: latest date by which the document has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2013-07-31 latest date by which the national standards conflicting w
15、ith the document have to be withdrawn (dow) 2015-10-31 This document supersedes EN 60968:1990 + A1:1993 + A2:1999. EN 60968:2013 includes the following significant technical changes with respect to EN 60968:1990 + A1:1993 + A2:1999: - for reasons of photobiological safety, the scope has been extende
16、d; - a new definition and clause on UV radiation have been introduced; - clauses on normative references and an annex on literature were added; - the latest IEC template has been adapted. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent ri
17、ghts. CENELEC and/or CEN shall not be held responsible for identifying any or all such patent rights. This standard covers the Principle Elements of the Safety Objectives for Electrical Equipment Designed for Use within Certain Voltage Limits (LVD - 2006/95/EC). Endorsement notice The text of the In
18、ternational Standard IEC 60968:2012 was approved by CENELEC as a European Standard without any modification. In the official version, for Bibliography, the following note has to be added for the standard indicated : IEC 62471:2006 NOTE Harmonised as EN 62471:2008 (modified). BS EN 60968:2013Copyrigh
19、t European Committee for Electrotechnical Standardization Provided by IHS under license with CENELECNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- 3 - EN 60968:2013 Annex ZA (normative) Normative references to international publications with their corresponding E
20、uropean publications The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendme
21、nts) applies. NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. Publication Year Title EN/HD Year IEC 60061 - Lamp caps and holders together with gauges for the control of interchangeability and safety - - IEC 60061-1 -
22、Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 1: Lamp caps EN 60061-1 - IEC 60061-3 - Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 3: Gauges EN 60061-3 - IEC 60238 - Edison screw lampholders EN
23、 60238 - IEC 60360 - Standard method of measurement of lamp cap temperature rise EN 60360 - IEC 60695-2-10 2000 Fire hazard testing - Part 2-10: Glowing/hot-wire based test methods - Glow-wire apparatus and common test procedure EN 60695-2-10 2001 IEC 60695-2-11 + corr. January 2000 2001 Fire hazard
24、 testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products EN 60695-2-11 2001 IEC 60695-2-12 2010 Fire hazard testing - Part 2-12: Glowing/hot-wire based test methods - Glow-wire flammability index (GWFI) test method for materials EN 60695-2-12 20
25、10 IEC 60695-2-13 + corr. February 2010 2012 Fire hazard testing - Part 2-13: Glowing/hot-wire based test methods - Glow-wire ignition temperature (GWIT) test method for materials EN 60695-2-13 2010 IEC 60901 - Single-capped fluorescent lamps - Performance specifications EN 60901 - BS EN 60968:2013C
26、opyright European Committee for Electrotechnical Standardization Provided by IHS under license with CENELECNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- 2 60968 IEC:2012 CONTENTS INTRODUCTION . 5 1 Scope . 6 2 Normative references . 6 3 Terms and definitions . 7
27、 4 General requirement and general test requirements . 8 5 Marking 8 6 Interchangeability . 9 7 Protection against electric shock 10 8 Insulation resistance and electric strength after humidity treatment 10 8.1 General . 10 8.2 Insulation resistance . 10 8.3 Electric strength 10 9 Mechanical strengt
28、h . 11 10 Cap temperature rise 11 11 Resistance to heat 12 12 Resistance to flame and ignition . 12 13 Fault conditions 13 14 UV radiation . 17 Bibliography 18 Figure 1 Dimming not allowed 9 Figure 2 Standard test finger 14 Figure 3 Holder for torsion test on lamps with screw caps 15 Figure 4 Holder
29、 for torque test on lamps with bayonet caps . 16 Figure 5 Ball-pressure apparatus . 17 Table 1 Interchangeability gauges and lamp cap dimensions . 9 BS EN 60968:2013Copyright European Committee for Electrotechnical Standardization Provided by IHS under license with CENELECNot for ResaleNo reproducti
30、on or networking permitted without license from IHS-,-,-60968 IEC:2012 5 INTRODUCTION With IEC 62471 and IEC/TR 62471-2, there are horizontal requirements available that need to be introduced into product standards, e.g. to IEC 60968. The horizontal requirement is transformed into a requirement for
31、self-ballasted lamps. The lamps within the scope of this standard are general lighting service (GLS) lamps according to the definition 3.11 in IEC 62471:2006. “.lamps intended for lighting spaces that are typically occupied or viewed by people.“. According to Clause 6 of IEC 62471:2006, radiation of
32、 GLS lamps is measured at a distance equivalent to 500 lx. Measured at the 500 lx distance, GLS lamps will not exceed risk group 1 for blue light hazard and risk group 0 for IR radiation. This combination of risk group and hazard does not require marking (Table 1 of IEC/TR 62471-2:2009). Hazards fro
33、m UV radiation of GLS lamps will be covered by Clause 14 of IEC 60968. Hence, IEC 62471 does not require any additional marking for GLS lamps. BS EN 60968:2013Copyright European Committee for Electrotechnical Standardization Provided by IHS under license with CENELECNot for ResaleNo reproduction or
34、networking permitted without license from IHS-,-,- 6 60968 IEC:2012 SELF-BALLASTED LAMPS FOR GENERAL LIGHTING SERVICES Safety requirements 1 Scope This International Standard specifies the safety and interchangeability requirements, together with the test methods and conditions, required to show com
35、pliance of tubular fluorescent and other gas-discharge lamps with integrated means for controlling starting and stable operation (self-ballasted lamps), intended for domestic and similar general lighting purposes, having: a rated wattage up to 60 W; a rated voltage of 100 V to 250 V; Edison screw or
36、 bayonet caps. The requirements of this standard relate only to type testing. Recommendations for whole product testing or batch testing are under consideration. This part of the standard covers photobiological safety according to IEC 62471 and IEC/TR 62471-2. Blue light and infrared hazards are bel
37、ow the level which requires marking. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the ref
38、erenced document (including any amendments) applies. IEC 60061, Lamp caps and holders together with gauges for the control of interchangeability and safety IEC 60061-1, Lamp caps and holders together with gauges for the control of interchangeability and safety Part 1: Lamp caps IEC 60061-3, Lamp cap
39、s and holders together with gauges for the control of interchangeability and safety Part 3: Gauges IEC 60238, Edison screw lampholders IEC 60360, Standard method of measurement of lamp cap temperature rise IEC 60695-2-10:2000, Fire hazard testing Part 2-10: Glowing/hot-wire based test methods Glow-w
40、ire apparatus and common test procedure IEC 60695-2-11:2000, Fire hazard testing Part 2-11: Glowing/hot-wire based test methods Glow-wire flammability test method for end products BS EN 60968:2013Copyright European Committee for Electrotechnical Standardization Provided by IHS under license with CEN
41、ELECNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-60968 IEC:2012 7 IEC 60695-2-12:2010, Fire hazard testing Part 2-12: Glowing/hot-wire based test methods Glow-wire flammability test method for materials IEC 60695-2-13:2010, Fire hazard testing Part 2-13: Glowing
42、/hot-wire based test methods Glow-wire ignitability test method for materials IEC 60901, Single-capped fluorescent lamps Performance specifications 3 Terms and definitions For the purposes of this document, the following terms and definitions apply: 3.1 self-ballasted lamp unit which cannot be disma
43、ntled without being permanently damaged, provided with a lamp cap and incorporating a light source and any additional elements necessary for starting and stable operation of the light source 3.2 type lamps that, independent of the type of cap, are identical in photometric and electrical rating 3.3 r
44、ated voltage voltage or voltage range marked on the lamp 3.4 rated wattage wattage marked on the lamp 3.5 rated frequency frequency marked on the lamp 3.6 cap temperature rise tssurface temperature rise (above ambient) of a standard test lampholder fitted to the lamp, when measured in accordance wit
45、h the standard method described in IEC 60360 3.7 live part conductive part which may cause an electric shock in normal use 3.8 type test test or series of tests made on a type test sample for the purpose of checking compliance of the design of a given product with the requirements of the relevant st
46、andard 3.9 type test sample sample consisting of one or more similar units submitted by the manufacturer or responsible vendor for the purpose of the type test 3.10 specific effective radiant UV power effective power of the UV radiation of a lamp related to its luminous flux BS EN 60968:2013Copyrigh
47、t European Committee for Electrotechnical Standardization Provided by IHS under license with CENELECNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- 8 60968 IEC:2012 Note 1 to entry: The specific effective radiant UV power is expressed in mW/klm. Note 2 to entry: T
48、he effective power of the UV radiation is obtained by weighting the spectral power distribution of the lamp with the UV hazard function SUV(). Information about the relevant UV hazard function is given in IEC 62471. It only relates to possible hazards regarding UV exposure of human beings. It does not deal with the possible influence of optical radiation on materials, like mechanical damage or discoloration. 4 General requirement and general test requirements 4.1 Self-ballasted lamps shall be so designed and constructed t