1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationSafety of transportable motor-operated electric toolsPart 2-12: Particular requirements for threading machinesBS EN 61029-2-12:2011National forewordThis British Standard is the U
2、K implementation of EN 61029-2-12:2011. It isidentical to IEC 61029-2-12:2010.The UK participation in its preparation was entrusted to Technical CommitteeCPL/116, Portable motor-operated tools.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publi
3、cation does not purport to include all the necessary provisions of acontract. Users are responsible for its correct application. BSI 2011ISBN 978 0 580 56305 8ICS 25.080.99; 25.100.50Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published u
4、nder the authority of the StandardsPolicy and Strategy Committee on 31 July 2011.Amendments issued since publicationAmd. No. Date Text affectedBRITISH STANDARDBS EN 61029-2-12:2011EUROPEAN STANDARD EN 61029-2-12 NORME EUROPENNE EUROPISCHE NORM April 2011 CENELEC European Committee for Electrotechnic
5、al Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Management Centre: Avenue Marnix 17, B - 1000 Brussels 2011 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 61029-
6、2-12:2011 E ICS 25.080.99; 25.100.50 English version Safety of transportable motor-operated electric tools - Part 2-12: Particular requirements for threading machines (IEC 61029-2-12:2010, modified) Scurit des machines-outils lectriques semi-fixes - Partie 2-12: Exigences particulires pour les machi
7、nes fileter (CEI 61029-2-12:2010, modifie) Sicherheit transportabler motorbetriebener Elektrowerkzeuge - Teil 2-12: Besondere Anforderungen fr Gewindeschneidmaschinen (IEC 61029-2-12:2010, modifiziert) This European Standard was approved by CENELEC on 2011-01-02. CENELEC members are bound to comply
8、with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secret
9、ariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as th
10、e official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, P
11、oland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. BS EN 61029-2-12:2011EN 61029-2-12:2011 - 2 - Foreword The text of the International Standard IEC 61029-2-12:2010, prepared by IEC TC 116, Safety of hand-held motor-operated electric tools, together with
12、 common modifications prepared by the Technical Committee CENELEC TC 116, Safety of motor-operated electric tools, was submitted to the formal vote and was approved by CENELEC as EN 61029-2-12 on 2011-01-02. Attention is drawn to the possibility that some of the elements of this document may be the
13、subject of patent rights. CEN and CENELEC shall not be held responsible for identifying any or all such patent rights. The following dates are proposed: latest date by which the amendment has to be implementedat national level by publication of an identical national standard or by endorsement (dop)
14、2012-01-02 latest date by which the national standards conflicting with the amendment have to be withdrawn (dow) 2014-01-02 This European Standard is divided into two parts: Part 1 General requirements, which are common to most transportable motor, operated tools (for the purpose of this European St
15、andard referred to simply as tools) which could come within the scope of this European Standard. Part 2 Requirements for particular types of tool which either supplement or modify the requirements given in Part 1 to account for the particular hazards and characteristics of these specific tools. This
16、 European Standard has been prepared under Mandate M/396 given to CENELEC by the European Commission and the European Free Trade Association and covers essential requirements of EU Directive 2006/42/EC. See Annex ZZ. Compliance with the relevant clauses of Part 1 together with a relevant Part 2 of t
17、his European Standard provides one means of confirming with the specified essential requirements of the Directive. For noise and vibration this European Standard covers the requirements for their measurement, the provisions of information arising from these measurements and the provision of informat
18、ion about the Personal Protective Equipment required. Specific requirements for the reduction of the risk arising from noise and vibration through the design of the tool are not given as this reflects the current state of art. Warning: Other requirements arising from other European Directives can be
19、 applicable to the products falling within the scope of this European Standard. CEN have prepared standards for industrial machines, which may extend transportable machines. Although CEN and CENELEC have where appropriate used common solutions to provide uniform levels of protection, person using th
20、is European Standard should check the scope of both this and CEN standards to ensure that a correct standard is used. This Part 2-12 is to be used in conjunction with EN 61029-1:2009. This Part 2-12 supplements or modifies the corresponding clauses of EN 61029-1, so as to convert it into the Europea
21、n Standard: “Particular requirements for threading machines”. BS EN 61029-2-12:2011- 3 - EN 61029-2-12:2011 Where a particular subclause of Part 1 is not mentioned in this Part 2-12, that subclause applies as far as reasonable. Where this Part 2-12 states “addition“ “modification“ or “replacement“,
22、the relevant text of Part 1 is to be adapted accordingly. NOTE In this European Standard the following print types are used: - requirements proper: in roman type; - test specifications: in italic type; - explanatory matter: in smaller roman type. The terms defined in Clause 2 are printed in bold typ
23、eface. Clauses, subclauses, notes, tables and figures which are additional to those in Part 1 are numbered starting from 101. Clauses, subclauses, notes, tables and figures which are additional to those in IEC 61029-2-12:2010 are prefixed “Z“. The common modifications towards IEC 61029-2-12:2010 are
24、 identified by a vertical line in the left margin. BS EN 61029-2-12:2011EN 61029-2-12:2011 - 4 - Contents 1 Scope . 52 Definitions . 53 General requirement 54 General notes on tests . 55 Rating . 56 Classification 57 Marking and information for use . 68 Protection against electric shock 109 Starting
25、 .1010 Input and current 1111 Heating .1112 Leakage current .1113 Environmental requirements 1114 Protection against ingress of foreign bodies and moisture resistance .1215 Insulation resistance and electric strength .1216 Endurance 1217 Abnormal operation 1218 Stability and mechanical hazards .1219
26、 Mechanical strength .1220 Construction .1221 Internal wiring .1322 Components .1323 Supply connection and external flexible cables and cords 1324 Terminals for external conductors 1325 Provision for earthing .1326 Screws and connections 1327 Creepage distances, clearances and distance through insul
27、ation .1328 Resistance to heat, fire and tracking 1429 Resistance to rusting 1430 Radiation 14BS EN 61029-2-12:2011- 5 - EN 61029-2-12:2011 1 Scope This clause of Part 1 is applicable except as follows: 1.1 Addition: This European Standard applies to pipe threading tools that create external threads
28、 by rotating either the workpiece or the cutting head. 2 Definitions This clause of Part 1 is applicable except as follows: 2.21 Replacement: normal load load to obtain rated input 2.101 threading machine tool that is capable of creating an external thread through a mechanical process such as cuttin
29、g or forming 2.102 BSPT style threads British Standard Pipe Taper style threads: 55 degree pressure-tight taper pipe threads (R) per ISO 7-1 2.103 NPT style threads National Pipe Taper style threads: 60 degree pressure-tight taper pipe threads (NPT) per ANSI/ASME B1.20.2M 3 General requirement This
30、clause of Part 1 is applicable. 4 General notes on tests This clause of Part 1 is applicable. 5 Rating This clause of Part 1 is applicable. 6 Classification This clause of Part 1 is applicable. BS EN 61029-2-12:2011EN 61029-2-12:2011 - 6 - 7 Marking and information for use This clause of Part 1 is a
31、pplicable except as follows: 7.1 Addition: In addition the tool shall have the following marking: maximum diameter, in millimetres, of thread which can be cut. The diameter shall refer to a unified ISO thread to be cut on a pipe of steel having a tensile strength of 390 N/mm2, unless otherwise indic
32、ated on the tool. 7.13 Replacement: An instruction manual and safety instructions shall be provided with the tool and packaged in such a way that is noticed by the user when the tool is removed from the packaging. The safety instructions may be separate from the instruction manual. An explanation of
33、 the symbols required by this standard shall be provided in either the instruction manual or the safety instructions. They shall be written in the official language(s) of the country in which the tool is sold. They shall be legible and contrast with the background. The words Original instructions sh
34、all appear on the language version(s) verified by the manufacturer or his authorised representative. Where no Original instructions exist in the official language(s) of the country where the tool is to be used, a translation into that/those language(s) shall be provided by the manufacturer or his au
35、thorised representative or by the person bringing the tool into the language area in question. The translations shall bear the words Translation of the original instructions and they shall be accompanied by a copy of the Original instructions. 7.13.101 Safety warnings The safety warnings specified i
36、n 7.13.101.1 and 7.13.101.2, if in English, shall be verbatim and in the exact order as given and in any other official language to be equivalent. Format of all safety instructions must differentiate, by font highlighting or similar means, the context of the clauses as illustrated below. All notes i
37、n the safety warnings are not to be printed, they are information for the designer of the manual. 7.13.101.1 General power tool safety warnings WARNING Read all safety warnings and all instructions. Failure to follow the warnings and instructions may result in electric shock, fire and/or serious inj
38、ury. Save all warnings and instructions for future reference. 1) Work area safety a) Keep work area clean and well lit. Cluttered or dark areas invite accidents. b) Do not operate power tools in explosive atmospheres, such as in the presence of flammable liquids, gases or dust. Power tools create sp
39、arks which may ignite the dust or fumes. c) Keep children and bystanders away while operating a power tool. Distractions can cause you to lose control. BS EN 61029-2-12:2011- 7 - EN 61029-2-12:2011 2) Electrical safety a) Power tool plugs must match the outlet. Never modify the plug in any way. Do n
40、ot use any adapter plugs with earthed (grounded) power tools. Unmodified plugs and matching outlets will reduce risk of electric shock. b) Avoid body contact with earthed or grounded surfaces, such as pipes, radiators, ranges and refrigerators. There is an increased risk of electric shock if your bo
41、dy is earthed or grounded. c) Do not expose power tools to rain or wet conditions. Water entering a power tool will increase the risk of electric shock. d) Do not abuse the cord. Never use the cord for carrying, pulling or unplugging the power tool. Keep cord away from heat, oil, sharp edges or movi
42、ng parts. Damaged or entangled cords increase the risk of electric shock. e) When operating a power tool outdoors, use an extension cord suitable for outdoor use. Use of a cord suitable for outdoor use reduces the risk of electric shock. f) If operating a power tool in a damp location is unavoidable
43、 or there is the likelihood of cutting into the cord, use a residual current device (RCD) protected supply. Use of an RCD reduces the risk of electric shock. NOTE The term “residual current device (RCD)” may be replaced by the term “ground fault circuit interrupter (GFCI)” or “earth leakage circuit
44、breaker (ELCB)”. 3) Personal safety a) Stay alert, watch what you are doing and use common sense when operating a power tool. Do not use a power tool while you are tired or under the influence of drugs, alcohol or medication. A moment of inattention while operating power tools may result in serious
45、personal injury. b) Use personal protective equipment. Always wear eye protection. Protective equipment such as dust mask, non-skid safety shoes, hard hat, or hearing protection used for appropriate conditions will reduce personal injuries. c) Prevent unintentional starting. Ensure the switch is in
46、the off-position before connecting to power source and/or battery pack, picking up or carrying the tool. Carrying power tools with your finger on the switch or energising power tools that have the switch on invites accidents. d) Remove any adjusting key or wrench before turning the power tool on. A
47、wrench or a key left attached to a rotating part of the power tool may result in personal injury. e) Do not overreach. Keep proper footing and balance at all times. This enables better control of the power tool in unexpected situations. f) Dress properly. Do not wear loose clothing or jewellery. Kee
48、p your hair and clothing away from moving parts. Loose clothes, jewellery or long hair can be caught in moving parts. g) If devices are provided for the connection of dust extraction and collection facilities, ensure these are connected and properly used. Use of dust collection can reduce dust-relat
49、ed hazards. 4) Power tool use and care a) Do not force the power tool. Use the correct power tool for your application. The correct power tool will do the job better and safer at the rate for which it was designed. b) Do not use the power tool if the switch does not turn it on and off. Any power tool that cannot be controlled with the switch is dangerous and must be repaired. c) Disconnect the plug from the power source and/or