1、BRITISH STANDARDBS EN 61169-16:2007Radio-frequency connectors Part 16: Sectional specification RF coaxial connectors with inner diameter of outer conductor 7 mm (0,276 in) with screw coupling Characteristic impedance 50 ohms (75 ohms) (type N)The European Standard EN 61169-16:2007 has the status of
2、a British StandardICS 33.120.30g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58BS EN 61169-16:2007This British Standard was published under the auth
3、ority of the Standards Policy and Strategy Committee on 31 May 2007 BSI 2007ISBN 978 0 580 50828 8National forewordThis British Standard was published by BSI. It is the UK implementation of EN 61169-16:2007. It is identical with IEC 61169-16:2007. It supersedes BS QC222100:1997 which is withdrawn.Th
4、e UK participation in its preparation was entrusted by Technical Committee EPL/46, Cables, wires and waveguides, radio frequency connectors and accessories for communication and signalling, to Subcommittee EPL/46/2, Radio frequency connectors and waveguides.A list of organizations represented on thi
5、s committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations. Amendments issued since
6、 publicationAmd. No. Date CommentsEUROPEAN STANDARD EN 61169-16 NORME EUROPENNE EUROPISCHE NORM April 2007 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stas
7、sart 35, B - 1050 Brussels 2007 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 61169-16:2007 E ICS 33.120.30 English version Radio-frequency connectors - Part 16: Sectional specification - RF coaxial connectors with inner diamete
8、r of outer conductor 7 mm (0,276 in) with screw coupling - Characteristic impedance 50 ohms (75 ohms) (type N) (IEC 61169-16:2006) Connecteurs pour frquences radiolectriques - Partie 16: Spcification intermdiaire - Connecteurs coaxiaux pour frquences radiolectriques avec diamtre intrieur du conducte
9、ur extrieur de 7 mm (0,276 in) verrouillage vis - Impdance caractristique de 50 ohms (75 ohms) (Type N) (CEI 61169-16:2006) Hochfrequenz-Steckverbinder - Teil 16: Rahmenspezifikation - Koaxiale Hochfrequenzsteckverbinder mit 7 mm (0,276 in) Innendurchmesser des Auenleiters und Schraubverbindung - We
10、llenwiderstand 50 Ohm (75 Ohm) (Typ N) (IEC 61169-16:2006) This European Standard was approved by CENELEC on 2007-03-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard wi
11、thout any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other lang
12、uage made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, De
13、nmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. EN 61169-16:2007 2 Foreword The text of document 46F/54
14、/FDIS, future edition 1 of IEC 61169-16, prepared by SC 46F, R.F. and microwave passive components, of IEC TC 46, Cables, wires, waveguides, R.F. connectors, R.F. and microwave passive components and accessories, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 61169-
15、16 on 2007-03-01. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2007-12-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 201
16、0-03-01 Annex ZA has been added by CENELEC. _ Endorsement notice The text of the International Standard IEC 61169-16:2006 was approved by CENELEC as a European Standard without any modification. _ 3 EN 61169-16:2007 CONTENTS 1 Scope 5 2 Normative references .5 3 IEC type designation 6 4 Interface di
17、mensions 6 4.1 Dimensions General purpose connectors Grade 2 6 5 Mechanical gauges and standard test connectors11 5.1 Mechanical gauges11 5.2 Standard test connectors Grade 0 .12 6 Overall dimensions .16 7 Quality assessment procedures 16 7.1 General .16 7.2 Ratings and characteristics16 7.3 Test sc
18、hedule and inspection requirements19 7.4 Procedures21 8 Instructions for preparation of detail specifications 21 8.1 General .21 8.2 Identification of the Detail specification 21 8.3 Identification of the component 22 8.4 Performance22 8.5 Marking, ordering information and related matters 22 8.6 Sel
19、ection of tests, test conditions and severities.22 8.7 Blank detail specification pro-forma for type N connector23 Annex A (informative) Guidance information for interface dimensions of 75 characteristic impedance general purpose connectors .28 Annex ZA (normative) Normative references to internatio
20、nal publications with their corresponding European publications31 Bibliography .30 Figure 1 Connector with pin centre contact 7 Figure 2 Details of pin centre contact 7 Figure 3 Connector with socket centre contact .9 Figure 4 Details of socket centre contact .9 Figure 5 Gauge rings for outer contac
21、t of pin connector 11 Figure 6 Gauge and test pins for socket centre contact 12 Figure 7 Standard test connector with pin centre contact .13 Figure 8 Details of pin centre contact 13 Figure 9 Standard test connector with socket centre contact 15 Figure 10 Details of socket centre contact .15 Figure
22、A.1 Details of pin centre contact 28 Table 1 Dimensions for connector with pin centre contact .8 Table 2 Dimensions for connector with socket centre contact10 EN 61169-16:2007 4 Table 3 Dimensions for test pins for socket centre contact 12 Table 4 Dimensions for standard test connector with pin cent
23、re contact 14 Table 5 Dimensions for standard test connector with socket centre contact .16 Table 6 Ratings and characteristics17 Table 7 Acceptance tests .19 Table 8 Periodic tests 20 5 EN 61169-16:2007 RADIO-FREQUENCY CONNECTORS Part 16: Sectional specification RF coaxial connectors with inner dia
24、meter of outer conductor 7 mm (0,276 in) with screw coupling Characteristics impedance 50 (75 ) (type N) 1 Scope This part of IEC 61169, which is a Sectional Specification (SS), provides information and rules for the preparation of Detail Specifications (DS) for pin and socket R.F. coaxial connector
25、s, with screw coupling mechanism, for low to medium power applications. The connector is commonly known as the “type N“. Three versions of the 50 characteristic impedance type N connector are included, each version being mateable with each of the others. The general purpose connector (grade 2) deriv
26、ed from the specifications MIL-C17B and MIL-C-39012 may preferably be used with R.F. cable 60096 IEC 50-7 up to about 12 GHz maximum frequency. The high performance connector (grade 1) is particularly suitable for microwave applications when lower reflection factors than are offered by the general p
27、urpose connector are required. The connectors may also be suitable for microwave components. The tolerances of the interface dimensions lie between those for grade 0 and grade 2, and are chosen to give the performance required. Some grade 1 connectors conforming to this specification may be used up
28、to 18 GHz maximum frequency. The standard test connector (grade 0) has a closely controlled interface to provide a reference for the measurement of connectors, cable assemblies, components and equipment with the above two interfaces. It may also be used as a microwave connector in situations when th
29、e most precise interface for use up to 18 GHz maximum frequency is required. A 75 characteristic impedance connector is given in Annex A even though the use of 75 type N connectors is strongly deprecated. Accidental cross-coupling of 75 with 50 connectors can destructively damage the 75 version, but
30、 in view of the extensive use of a number of marginally different 75 versions, the interface now given provides common design guidance. 75 connectors should be clearly identified. This specification indicates the recommended performance characteristics to be considered when writing a DS and covers t
31、est schedules and inspection requirements. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amen
32、dments) applies. IEC 60068-1:1988, Environmental testing Part 1: General and guidance Amendment 1 (1992) EN 61169-16:2007 6 IEC 60096-2:1988, Radio-frequency cables Part 2: Relevant cable specifications IEC 61169-1:1992, Radio-frequency connectors Part 1: Generic specification General requirements a
33、nd measuring methods Amendment 1 (1996) Amendment 2 (1997) ISO 263:1973, ISO inch screw threads General plan and selection for screws, bolts and nuts Diameter range 0.06 to 6 in 3 IEC type designation Connectors conforming to this specification shall be designated by: a) the reference to this specif
34、ication: 61169-16 IEC; b) characteristic impedance 50 (75 ); c) number of the grade : grade 0 = standard test connector = G 0; grade 1 = high performance connector = G 1; grade 2 = general purpose connector if grade 2 is required, no grade designation is necessary; d) a group of figures specifying t
35、he climatic category (see 7.2.5). Example: 61169-16 IEC-50-G 0 denotes a standard test connector, type N, 50 . 4 Interface dimensions 4.1 Dimensions General purpose connectors Grade 2 4.1.1 General Inch dimensions are original dimensions. NOTE The values for dimensions in millimetres derived from th
36、ose in inches are not necessarily exact (according to ISO 3701), but they should be considered as acceptable alternatives to the original values. All undimensioned pictorial configurations are for reference purposes only. _ 1This document has been withdrawn. 7 EN 61169-16:2007 4.1.2 Connector with p
37、in centre contact ab c h r (Note 9) kmnfNote 5 Note 3 Note 1 Note 6 H O M H MIEC 2246/06 Figure 1 Connector with pin centre contact (for notes and dimensions, see Table 1) p Note 1e s g q d Note 7 ab IEC 2247/06Figure 2 Details of pin centre contact (for notes and dimensions, see Table 1) EN 61169-1
38、6:2007 8 Table 1 Dimensions for connector with pin centre contact mm inches Reference Min. Max. Min. Max. Note a 7,00 nom. 0,275 6 nom. 2, diam. b 8,027 0,316 3/10, diam. c 5/8-24 UNEF-2B 4 d 3,04 nom. 0,120 nom. 2, diam. e f g h k m n p q r s ab 5.33 9,25 0,0 16,0 0,41 4,013 4,5 1,600 0,15 2,79 1,5
39、7 1,52 4,267 1,676 0,1 3,56 0,64 0.210 0,364 0,0 0,630 0,016 0,158 0,177 0,063 0,006 0,110 0,062 0,060 0,168 0,066 0,004 0,140 0,025 6 10, diam. 8 10, diam. radius 9 7, radius NOTE 1 Mechanical and electrical reference plane. NOTE 2 Diameter of outer and centre contact to provide nominal (50 ) chara
40、cteristic impedance to meet electrical performance requirements. NOTE 3 Slots or other forms of resilience optional. If slotted, indicated dimension b should not exceed 8,38 mm (0,330 in). Gauging requirements (see 5.1.1) to be met. NOTE 4 Thread 5/8-24 UNEF-2B (according to ISO 263). NOTE 5 Compens
41、ation for inductance of inner conductor gap in mated pair of connectors optional. NOTE 6 Dimensions given assume no sealing gasket fitted. If sealing is required, dimension (Figure 1) should be arranged so that with the gasket chosen adequate pressure is applied to the front face (dimensions w and x
42、) of the socket connector (Figure 2) to ensure adequate sealing. NOTE 7 Radius or chamfer, shape of tip optional. 0,25 mm (0,010 in) maximum flat permitted. NOTE 8 Applies with nut biased forward. NOTE 9 External form of leading edge of outer contact optional, but connector should meet electrical an
43、d mechanical performance requirements. NOTE 10 Diameters b, h and p and thread c should be gauged to ensure that on MMC, each feature is on or can take up a common axis. 9 EN 61169-16:2007 4.1.3 Connector with socket centre contact aNote 1 H b y x w cy h f e madn z k r (Note 5) Note 4 O M H M IEC 22
44、48/06 Figure 3 Connector with socket centre contact (for notes and dimensions, see Table 2) dNote 6 spIEC 2249/06Figure 4 Details of socket centre contact (for notes and dimensions, see Table 2) EN 61169-16:2007 10 Table 2 Dimensions for connector with socket centre contact mm inches Reference Min.
45、Max. Min. Max. Note a 7,06 0,278 2, diam. b 8,027 8,13 0,316 0,320 diam. c 5/8-24 UNEF-2A 3 d 3,04 nom. 0,120 nom. 2, diam. e f h k m n p r s w x y z ad 4,75 9,05 10,72 1,19 4,37 5,33 8,53 6,76 5,26 9,19 15,93 1,96 1,2 8,74 0,13 0,187 0,356 0,422 0,047 0,172 0,210 0,336 0,266 0,207 0,362 0,627 0,077
46、 0,047 0,344 0,005 diam. 7 6, diam. 5 4, diam. 4, diam. diam. radius NOTE 1 Mechanical and electrical reference plane. NOTE 2 Nominal inner diameter of outer conductor 7,0 mm (0,275 6 in). Diameter of outer and centre contact to provide nominal (50 ) characteristic impedance to meet electrical perfo
47、rmance requirements. NOTE 3 Thread 5/8-24 UNEF-2A (according to ISO 263). NOTE 4 If sealing is required, dimension (Figure 1) should be arranged so that with the gasket chosen, adequate pressure is applied to the front face (dimensions w and x) of the socket connector (Figure 3) to ensure adequate s
48、ealing. NOTE 5 Radius only to ensure satisfactory sealing, but if chamfer is used, it should not encroach into minimum material condition of the design using the radius. NOTE 6 Centre contact design is optional. It should however, meet the gauging requirements of 5.1.2 and relevant reflection factor requirements of Clause 3 using grade 0 connector in accordance with Figure 7. NOTE 7 Applies to length of thread and not undercut. 11 EN 61169-16:2007 5 Mechanical gauges and standard test connectors 5.1 Mechanical gauges 5.1.1 Connectors with pin centre contact 5.1.1.1 Gauge for oute