1、BSI Standards PublicationRadio-frequency connectorsPart 49: Sectional specification for SMAA series R.F connectorsBS EN 61169-49:2014National forewordThis British Standard is the UK implementation of EN 61169-49:2014. It isidentical to IEC 61169-49:2014.The UK participation in its preparation was en
2、trusted to TechnicalCommittee EPL/46, Cables, wires and waveguides, radio frequency connectors and accessories for communication and signalling.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necess
3、ary provisions ofa contract. Users are responsible for its correct application. The British Standards Institution 2014.Published by BSI Standards Limited 2014ISBN 978 0 580 81765 6ICS 33.120.30Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was p
4、ublished under the authority of theStandards Policy and Strategy Committee on 31 December 2014.Amendments/corrigenda issued since publicationDate Text affectedBRITISH STANDARDBS EN 61169-49:2014EUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN 61169-49 November 2014 ICS 33.120.30 English Version Rad
5、io-frequency connectors - Part 49: Sectional specification for SMAA series R.F connectors (IEC 61169-49:2014) Connecteurs pour frquences radiolectriques - Partie 49:Spcification intermdiaire relative aux connecteurs RFsrie SMAA (CEI 61169-49:2014) Hochfrequenz-Steckverbinder - Teil 49:Rahmenspezifik
6、ation fr Hochfrequenz-Steckverbinder derSerie SMAA (IEC 61169-49:2014) This European Standard was approved by CENELEC on 2014-06-12. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national
7、 standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A ver
8、sion in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria,
9、 Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland,
10、 Turkey and the United Kingdom. European Committee for Electrotechnical Standardization Comit Europen de Normalisation ElectrotechniqueEuropisches Komitee fr Elektrotechnische Normung CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2014 CENELEC All rights of exploitation in any form
11、 and by any means reserved worldwide for CENELEC Members. Ref. No. EN 61169-49:2014 E EN 61169-49:2014 - 2 - Foreword The text of document 46F/259/FDIS, future edition 1 of IEC 61169-49, prepared by SC 46F, “R.F. and microwave passive components“, of IEC TC 46, “Cables, wires, waveguides, R.F. conne
12、ctors, R.F. and microwave passive components and accessories“ was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as EN 61169-49:2014. The following dates are fixed: latest date by which the document has to be implemented at national level by publication of an identical national s
13、tandard or by endorsement (dop) 2015-05-21 latest date by which the national standards conflicting with the document have to be withdrawn (dow) 2017-06-12 Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC and/or CEN shall no
14、t be held responsible for identifying any or all such patent rights. Endorsement notice The text of the International Standard IEC 61169-49:2014 was approved by CENELEC as a European Standard without any modification. IEC 61169-35 NOTE Harmonised as EN 61169-35. BS EN 61169-49:2014- 3 - EN 61169-49:
15、2014 Annex ZA (normative) Normative references to international publications with their corresponding European publications The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cite
16、d applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE 1 When an International Publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. NOTE 2 Up-to-date information on the latest version
17、s of the European Standards listed in this annex is available here: www.cenelec.eu. Publication Year Title EN/HD Year IEC 60068-1 - Environmental testing - Part 1: General and guidance EN 60068-1 - IEC 61169-1 2013 Radio-frequency connectors - Part 1: Generic specification - General requirements and
18、 measuring methods EN 61169-1 2013 IEC 62037 series Passive RF and microwave devices, intermodulation level measurement - Part 1: General requirements and measuring methods EN 62037 series BS EN 61169-49:2014 2 IEC 61169-49:2014 IEC 2014 CONTENTS 1 Scope 6 2 Normative references 6 3 Mating face and
19、gauge information 7 3.1 Dimensions High performance connectors Grade 1 7 Connector with pin-centre contact . 7 3.1.1Connector with socket-centre contact . 8 3.1.23.2 Gauges 9 Gauge pins for socket-centre contact 9 3.2.1Test procedure . 9 3.2.23.3 Dimensions standard test connectors Grade 0 . 10 Conn
20、ector with pin-centre contact . 10 3.3.1Connector with socket-centre contact . 11 3.3.24 Quality assessment procedure . 12 4.1 General 12 4.2 Rating and characteristics (see Clause 5 of IEC 61169-1:2013) . 12 4.3 Test schedule and inspection requirements Periodic tests . 15 4.4 Procedures for the qu
21、ality conformance . 17 Quality conformance inspection 17 4.4.1Quality conformance and its maintenance General 4.4.2procedure . 17 5 Instructions for preparation of detail specifications (DS) 17 5.1 General 17 5.2 Identification of the component 17 5.3 Performance 17 5.4 Marking, ordering information
22、 and related matters . 18 5.5 Selection of tests, test conditions and severities 18 5.6 Blank detail specification pro-forma for type SMAA connector 18 6 Marking . 22 6.1 Marking of component 22 6.2 Marking and contents of package . 23 Bibliography 24 Figure 1 Connector with pin-centre contact (for
23、dimensions and notes, see Table 1) . 7 Figure 2 Connector with socket-centre contact (for dimensions and notes, see Table 2) . 8 Figure 3 Gauge pins for socket-centre contact (for dimensions and notes, see Table 3) 9 Figure 4 Connector with pin-centre contact (for dimensions and notes, see Table 4)
24、. 10 Figure 5 Connector with socket-centre contact (for dimensions and notes, see Table 5) . 11 Table 1 Dimensions of connector with pin-centre contact . 7 Table 2 Dimensions of connector with socket-centre contact 8 Table 3 Dimensions of gauge pins for socket-centre contact 9 Table 4 Dimensions of
25、connector with pin-centre contact . 10 Table 5 Dimensions of connector with socket-centre contact 11 BS EN 61169-49:2014IEC 61169-49:2014 IEC 2014 3 Table 6 Preferred climatic categories (see IEC 60068-1) 12 Table 7 Rating and characteristics . 13 Table 8 Acceptance tests . 15 Table 9 Periodic tests
26、 16 BS EN 61169-49:2014 6 IEC 61169-49:2014 IEC 2014 RADIO-FREQUENCY CONNECTORS Part 49: Sectional specification for SMAA series R.F connectors 1 Scope This part of IEC 61169, which is a sectional specification (SS) , provides information and rules for the preparation of detail specifications (DS) f
27、or type SMAA series thread mated coaxial connectors. The connectors are normally used for micro wave applications, connecting with 50 RF cables or microstrips in an operating range up to 27 GHz. These connectors can be intermated with SMA (IEC 60169-15), 3,5 mm (IEEE 287-2007), 2,92 mm (IEC 61169-35
28、) connectors. It also prescribes mating face dimensions for high performance connectors grade 1, dimensional details of standard test connectors grade 0, for general purpose with gauging information and the mandatory tests selected from IEC 61169-1, applicable to all detail specifications relative t
29、o type SMAA connectors. This specification indicates the recommended performance characteristics to be considered when writing a DS and covers all tests schedules and inspection requirements. NOTE Metric dimension are original dimensions. All undimensioned pictorial configurations are for reference
30、purpose only. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (inclu
31、ding any amendments) applies. IEC 61169-1:2013, Radio frequency connectors Part 1: Generic specification General requirements and measuring methods IEC 60068-1, Environmental testing Part 1: General and guidance IEC 62037 (all parts), Passive RF and microwave devices, intermodulation level measureme
32、nt BS EN 61169-49:2014IEC 61169-49:2014 IEC 2014 7 3 Mating face and gauge information 3.1 Dimensions High performance connectors Grade 1 Connector with pin-centre contact 3.1.1h g a (1) q (3)pdt(4)erm j ksDetail A c b Gasket (2) See Detail A f 455 (4) (5) (6) (1) IEC 1208/14 Figure 1 Connector with
33、 pin-centre contact (for dimensions and notes, see Table 1) Table 1 Dimensions of connector with pin-centre contact Ref. mm Figure footnotes Min. Max. a 3,35 b 2,54 c 0,50 1,02 d 4,52 4,59 e 6,48 6,73 f 0,08 (5) g 0,00 0,13 h 0,00 0,13 j 2,54 k 0,30 m 1,27 (1) p (3) q (6) r 1,27 (nominal value) s 0,
34、902 0,935 t 1/4-36UNS-2B (4) (1) Mechanical and electrical reference plane. (2) Gasket possible on Grade 1 connectors. (3) Diameter is chosen to obtain a normal impedance of 50 1 . (4) Coupling nut twists position. (5) 0,08 mm max rounding chamfer, optional. (6) Dimension q should ensure the referen
35、ce plane superposition while satisfying the required environmental performance. BS EN 61169-49:2014 8 IEC 61169-49:2014 IEC 2014 Connector with socket-centre contact 3.1.2(5) j Detail A Root Cut (2) f 45 5 desc b a r(4)p(4)See Detail A h g (1) q (3)IEC 1209/14 Figure 2 Connector with socket-centre c
36、ontact (for dimensions and notes, see Table 2) Table 2 Dimensions of connector with socket-centre contact Ref. mm Figure footnotes Min. Max. a 5,54 b 4,32 (5) c 0,50 1,02 d 4,605 4,673 (2) e 5,28 5,49 f 0,00 0,13 g 0,00 0,10 h 0,00 0,10 j 2,92 p q 1,88 1,98 (1) r 1,27 (nominal value) (4) s 1/4-36UNS
37、-2A Detail A (3) (1) Mechanical and electrical reference plane. (2) Design for root cut to be allowed. (3) Design for slotting is optional. It is chosen to meet electrical and mechanical requirements, when mated with a 0,902 mm to 0,935 mm gauge pin. (4) Diameter shall be chosen to obtain a normal i
38、mpedance of 50 1 . (5) The shortest full thread length. BS EN 61169-49:2014IEC 61169-49:2014 IEC 2014 9 3.2 Gauges Gauge pins for socket-centre contact 3.2.1bR0,4 max 0,25 0,05 a 60 4 IEC 1210/14 Figure 3 Gauge pins for socket-centre contact (for dimensions and notes, see Table 3) Table 3 Dimensions
39、 of gauge pins for socket-centre contact Ref. Gauge A Maximum material for sizing purposes Gauge B Minimum material for measurement of retention force Mass of gauge: 28 g +2 g mm mm Min. Max. Min. Max. a 0,950 0,955 0,899 0,902 b 0,76 1,14 1,27 1,90 Material: steel, polished, surface roughness: Ra=0
40、,4 m maximum. Test procedure 3.2.2The gauge A shall be inserted into the socket-centre contact three times with a minimum depth of 0,76 mm. This is a sizing operation and should only be carried out when the socket-centre contact is removed from the connector. After this, the gauge B shall be inserte
41、d into socket-centre contact. The contact shall retain the mass of the gauge in a vertical downward position. BS EN 61169-49:2014 10 IEC 61169-49:2014 IEC 2014 3.3 Dimensions standard test connectors Grade 0 Connector with pin-centre contact 3.3.1h g a (3) (1) q (2)pduesSee Detail A 0,013 A 0,013 A
42、b A A rB 0,4 0,4j Detail A sA 0,013 t 0,03 f 45 5 (4) IEC 1211/14 Figure 4 Connector with pin-centre contact (for dimensions and notes, see Table 4) Table 4 Dimensions of connector with pin-centre contact Ref. mm Figure footnotes Min. Max. a 2,590 3,350 b 2,540 4,320 d 4,521 4,592 e 6,480 6,730 f 0,
43、080 (4) g 0,000 0,050 h 0,000 0,076 j 2,030 2,290 p q 2,030 (1) r 1,270 (nominal value) (2) s 0,902 0,927 t 42 48 u 1/4-36UNS-2B (3) (1) Mechanical and electrical reference plane. (2) Diameter shall be chosen to obtain a normal impedance of 50 0,25 . (3) Coupling nut twists position. (4) 0,08 mm max
44、. rounding chamfer, optional. BS EN 61169-49:2014IEC 61169-49:2014 IEC 2014 11 Connector with socket-centre contact 3.3.20,013 A 0,013 A A 0,4u Detail A Root Cut (2) f 45 5 deyc b p(3)See Detail A h g (1) q j B rkw(5)sv(4)B 0,013 IEC 1212/14 Figure 5 Connector with socket-centre contact (for dimensi
45、ons and notes, see Table 5) Table 5 Dimensions of connector with socket-centre contact Ref. mm Figure footnotes Min. Max. b 4,320 c 0,510 1,020 d 4,597 4,666 (2) e 5,283 5,490 f 0,150 g 0,000 0,050 h 0,000 0,076 j 3,050 3,300 k 0,080 p 3,925 3,945 q 1,880 1,980 (1) r 1,260 1,270 (3) s 0,965 0,990 t
46、42 48 u 1,650 1,800 v 1,285 1,300 (4) w 0,150 0,200 y 1/4-36UNS-2A (1) Mechanical and electrical reference plane. (2) Design for root cut to be allowed. (3) Diameter shall be chosen to obtain a normal impedance of 50 0,25 . (4) Diameter v is for the unslotted dimensions. (5) The slot width and the s
47、lot depth should be chosen to satisfy the requirement of mechanical and the electrical specification. BS EN 61169-49:2014 12 IEC 61169-49:2014 IEC 2014 4 Quality assessment procedure 4.1 General The following Subclauses 4.2 to 4.4 provide recommended rating, performance and test conditions to be con
48、sidered when writing a detail specification. They also provide an appropriate schedule of tests with minimum levels of conformance inspection sampling, together with the pro-forma blank detail specification (BDS) and instructions for the preparation of a detail specification. 4.2 Rating and characte
49、ristics (see Clause 5 of IEC 61169-1:2013) The values indicated below are recommended for SMAA series RF connectors and are given for the writer of the detail specification. They are applicable for the condition when the connectors are fully mated. Certain tests are listed without any recommended values being gi