1、BRITISH STANDARDBS EN 61212-3-1:2006Insulating materials Industrial rigid round laminated tubes and rods based on thermosetting resins for electrical purposes Part 3: Specifications for individual materials Sheet 1: Round laminated rolled tubesThe European Standard EN 61212-3-1:2006 has the status o
2、f a British StandardICS 29.035.01g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58BS EN 61212-3-1:2006This British Standard was published under the a
3、uthority of the Standards Policy and Strategy Committee on 30 June 2006 BSI 2006ISBN 0 580 48788 1National forewordThis British Standard is the official English language version of EN 61212-3-1:2006. It is identical with IEC 61212-3-1:2006. It supersedes BS EN 61212-3-1:1996 which is withdrawn.The U
4、K participation in its preparation was entrusted to Technical Committee GEL/15, Standards on specifications for electrical insulating materials (Provisional), which has the responsibility to: A list of organizations represented on this committee can be obtained on request to its secretary.Cross-refe
5、rencesThe British Standards which implement international or European publications referred to in this document may be found in the BSI Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British
6、 Standards Online.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. aid enquirers to understand the text; present to
7、 the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep UK interests informed; monitor related international and European developments and promulgate them in the UK.Summary of pagesThis document comprises a front cover, an inside front
8、 cover, the EN title page, pages 2 to 13 and a back cover.The BSI copyright notice displayed in this document indicates when the document was last issued.Amendments issued since publicationAmd. No. Date CommentsEUROPEAN STANDARD EN 61212-3-1 NORME EUROPENNE EUROPISCHE NORM May 2006 CENELEC European
9、Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2006 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CEN
10、ELEC members. Ref. No. EN 61212-3-1:2006 E ICS 29.035.01 Supersedes EN 61212-3-1:1995English version Insulating materials - Industrial rigid round laminated tubes and rods based on thermosetting resins for electrical purposes Part 3: Specifications for individual materials Sheet 1: Round laminated r
11、olled tubes (IEC 61212-3-1:2006) Matriaux isolants - Tubes et barres industriels rigides, ronds, stratifis, base de rsines thermodurcissables, usages lectriquesPartie 3: Spcifications pour matriaux particuliers Feuille 1: Tubes ronds, stratifis, enrouls(CEI 61212-3-1:2006) Isolierstoffe - Runde Rohr
12、e und Stbe aus technischen Schichtpressstoffen auf der Basis warmhrtender Harze fr elektrotechnische Zwecke - Teil 3: Bestimmungen fr einzelne Werkstoffe - Blatt 1: Runde, gewickelte Rohre aus technischen Schichtpressstoffen (IEC 61212-3-1:2006) This European Standard was approved by CENELEC on 2006
13、-04-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be o
14、btained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the C
15、entral Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, t
16、he Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. Foreword The text of document 15/272/FDIS, future edition 2 of IEC 61212-3-1, prepared by IEC TC 15, Standards on specifications for electrical insulating materials, was submitte
17、d to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 61212-3-1 on 2006-04-01. This European Standards supersedes EN 61212-3-1:1995. The main changes from EN 61212-3-1:1995 are as follows: added application use and safety statements; reformatted document to bring it up to current IEC/
18、CENELEC document format; new types EP GC 23 and PF CC 24 added and type PF CP 24 removed. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2007-01-01 latest date by which the n
19、ational standards conflicting with the EN have to be withdrawn (dow) 2009-04-01 Annex ZA has been added by CENELEC. _ Endorsement notice The text of the International Standard IEC 61212-3-1:2006 was approved by CENELEC as a European Standard without any modification. _ EN 61212-3-1:2006 2 CONTENTS I
20、NTRODUCTION.4 1 Scope 5 2 Normative references .5 3 Terms and definitions .5 4 Designations and abbreviations 6 4.1 General .6 4.2 Designation .6 4.3 Abbreviations 6 5 Requirements.7 Annex ZA (normative) Normative references to international publications with their corresponding European publication
21、s13 Table 1 Types of round rolled laminated tubes7 Tables 2 External and internal diameters of round rolled tubes8 Table 3 Permissible deviation from nominal internal diameter of round rolled tubes, all types9 Table 4 Tolerance for wall thickness for round rolled tubes .9 Table 5 Departure from stra
22、ightness for round rolled tubes .9 Table 6 Property requirements for round rolled tubes10 Table 7 Electric strength at 90 C in oil, perpendicular to laminations, for round rolled tubes (1 min proof test or 20 s step-by-step test)a(kV/mm).12 EN 61212-3-1:2006 3 INTRODUCTION This part of IEC 61212 is
23、one of a series which deals with industrial rigid round laminated tubes and rods based on thermosetting resins for electrical purposes. This series consists of three parts: Part 1: Definitions, designations and general requirements (IEC 61212-1) Part 2: Methods of test (IEC 61212-2) Part 3: Specific
24、ations for individual materials (IEC 61212-3) IEC 61212-3-1 contains one of the specification sheets comprising Part 3, as follows: Sheet 1: Round laminated rolled tubes. EN 61212-3-1:2006 4 _ INSULATING MATERIALS INDUSTRIAL RIGID ROUND LAMINATED TUBES AND RODS BASED ON THERMOSETTING RESINS FOR ELEC
25、TRICAL PURPOSES Part 3: Specifications for individual materials Sheet 1: Round laminated rolled tubes 1 Scope This part of IEC 61212-3 gives requirements for industrial rigid round laminated rolled tubes for electrical purposes, based on different resins and different reinforcements. Applications an
26、d distinguishing properties are given in Table 1. Materials which conform to this specification meet established levels of performance. However, the selection of a material by a user for a specific application should be based on the actual requirements necessary for adequate performance in that appl
27、ication and not based on this specification alone. Safety warning: It is the responsibility of the user of the methods contained or referred to in this document to ensure that they are used in a safe manner. 2 Normative references The following referenced documents are indispensable for the applicat
28、ion of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 61212-1:2006, Insulating materials Industrial rigid round laminated tubes and rods based on thermosetting resins f
29、or electrical purposes Part 1: Definitions, designations and general requirements IEC 61212-2:2006 Insulating materials Industrial rigid round laminated tubes and rods based on thermosetting resins for electrical purposes Part 2: Methods of test 1ISO 472, Plastics Vocabulary 3 Terms and definitions
30、For the purposes of this document, the following modified definition, which is taken from ISO 472, applies. 1To be published EN 61212-3-1:2006 5 3.1 round laminated rolled tube (as applied to thermosets) tube formed by rolling impregnated layers of material on a mandrel between heated pressure rolls
31、, curing in an oven, then removing the mandrel ISO 472 MOD 4 Designations and abbreviations 4.1 General The round laminated rolled tubes covered by this standard are classified into types which differ in the resin and reinforcement used, the method of manufacture and their distinguishing properties.
32、 4.2 Designation Individual types are designated by a two-letter abbreviation denoting the resin; a second two-letter abbreviation, denoting the reinforcement; a serial number of two digits, the first digit denoting the form of the material, a “2” indicates rolled tubes, and, a second digit denoting
33、 sub-grades of the same type. The abbreviations are given in 4.3. The complete designation of the rolled tube is denoted by: description: rolled tube; number of the IEC standard: IEC 6121231; designation of the individual type; dimensions (in millimetres) of the rolled tube: internal diameter x exte
34、rnal (diameter) x length; a letter designating the finish on the external diameter of the rolled tube: “A“ designating tubes in the “as produced“ condition; “B“ designating tubes in ground or turned condition. EXAMPLE Rolled tube, IEC 61212-3-1 EP GC 21 2561000 A 4.3 Abbreviations Types of resin Typ
35、es of reinforcement EP Epoxy (epoxide) CC Woven cotton cloth MF Melamine CP Cellulosic paper PF Phenolic GC Woven glass cloth SI Silicone MP Mica paper EN 61212-3-1:2006 6 5 Requirements In addition to the general requirements given in IEC 61212-1, the rolled tubes shall comply with the additional r
36、equirements given in Tables 2a, 2b, 3, 4, 6, and 7, with the exception of the length of the material supplied, which shall be subject to agreement between buyer and seller. Table 1 Types of round rolled laminated tubes Resin Reinforce-ment Serial numberApplications and distinguishing characteristics
37、a21 Mechanical, electrical and electronic applications. Extremely high mechanical strength at moderate temperatures. Very good stability of electrical properties when exposed to high relative humidity. 22 Similar to EP GC 21, but with high mechanical strength at elevated temperature. GC 23 Similar t
38、o EP GC 21, but with improved flame resistance. EP MP 21 Mechanical, electrical and electronic applications. Good stability of electrical properties when exposed to high relative humidity. Good heat resistance. MF GC 21 Mechanical and electrical applications. High mechanical strength. Good arc and t
39、racking resistance. 21 Mechanical and electrical applications. Fine weaveb. 22 Mechanical and electrical applications. Coarse weaveb. 23 Mechanical applications. Very coarse weaveb. CC 24 Similar to PF CC 21. For close tolerance machining applications (very fine weave)b21 Mechanical and low voltage
40、electrical applications. Good electrical properties when exposed to normal relative humidity. 22 High voltage electrical applications at power frequencies. High electric strength in oil. CP 23 Similar to type PF CP 21, but with improved electrical properties when exposed to high relative humidity. P
41、F GC 21 Mechanical and electrical applications. Very high mechanical strength at moderate temperatures. GC 21 Mechanical, electrical and electronic applications when exposed to high relative humidity. SI MP 21 Mechanical, electrical and electronic applications. Good stability of electrical propertie
42、s at elevated temperatures. aIt should not be inferred from the contents of Table 1 that round laminated rolled tubes of any particular type are necessarily unsuitable for applications other than those listed for them, or that specific round laminated rolled tubes will be suitable for all applicatio
43、ns within the wide description given. bFabric weaves of type CC reinforcements: Mass per unit area g/m2Thread count cm-1Very coarse weave 200 130 18 to 29 Fine weave 130 30 to 37 Very fine weave 125 37 These values are only for information. They are not to be considered as specification values. In g
44、eneral, the finer weave materials have better machining characteristics. EN 61212-3-1:2006 7 Tables 2 External and internal diameters of round rolled tubes Table 2a Permissible deviation from nominal external diameter of round rolled tubes in the “as rolled and cured” condition Maximum deviationa mm
45、 Type Nominal external diameter D mm PF CP All other types 10 10 500 0,2 0,3 0,3 0,4 0,5 0,6 0,7 0,9 1,2 1,5 0,4 0,5 0,5 0,7 1,0 1,5 1,7 2,0 2,2 2,5 Test method: see 4.2 of IEC 61212-2 a If a unilateral tolerance is agreed between purchaser and supplier, the tolerance shall not exceed twice the valu
46、e given in the table. Table 2b Permissible deviation from nominal external diameter of round rolled tubes in ground or turned condition, all types Nominal external diameter D mm Maximum deviationa mm 10 10 200 0,15 0,20 0,25 0,30 0,35 0,45 0,50 b Test method: see 4.2 of IEC 61212-2 aIf a unilateral
47、tolerance is agreed between purchaser and supplier, the tolerance shall not exceed twice the value given in the table. bBy agreement between purchaser and manufacturer. EN 61212-3-1:2006 8 Table 3 Permissible deviation from nominal internal diameter of round rolled tubes, all types Nominal internal
48、diameter d mm Maximum deviationa mm 3 3 500 0,10 0,15 0,20 0,30 0,40 0,50 0,70 1,00 1,50 2,00 Test method: see 4.3 of IEC 61212-2 aIf a unilateral tolerance is agreed between purchaser and supplier, the tolerance may not be greater thantwice the value given in the table. Table 4 Tolerance for wall t
49、hickness for round rolled tubes Maximum deviation mm Nominal wall thickness t mm All PF CP types All other types 1,5 1,5 25,0 0,25 0,40 0,50 0,80 1,20 1,60 0,40 0,50 0,50 0,80 1,20 1,60 Test method: see 4.4 of IEC 61212-2 Table 5 Departure from straightness for round rolled tubes Nominal external diameter D mm Maximum deviation mm D 8 8 L2D 8 6 L2The deviation from straightness of any tube shall not exceed the appropriat
copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1