1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationFibre optic interconnectingdevices and passive components Basic test and measurement proceduresPart 2-1: Tests Vibration (sinusoidal)BS EN 61300-2-1:2009National forewordThis Bri
2、tish Standard is the UK implementation of EN 61300-2-1:2009. It is identical to IEC 61300-2-1:2009, incorporating corrigendum January 2010. It supersedes BS EN 61300-2-1:2003 which is withdrawn.The UK participation in its preparation was entrusted by Technical Committee GEL/86, Fibre optics, to Subc
3、ommittee GEL/86/2, Fibre optic interconnecting devices and passive components.A list of organizations represented on this subcommittee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its co
4、rrect application. BSI 2010ISBN 978 0 580 54392 0ICS 33.180.20Compliance with a British Standard cannot confer immunity from legal obligations.This British Standard was published under the authority of the Standards Policy and Strategy Committee on 30 April 2010.Amendments/corrigenda issued since pu
5、blicationDate Text affectedBRITISH STANDARDBS EN 61300-2-1:2009The start and finish of text introduced or altered by corrigendum is indicated in the text by tags. Text altered by IEC corrigendum January 2010 is indicated in the text by .EUROPEAN STANDARD EN 61300-2-1 NORME EUROPENNE EUROPISCHE NORM
6、November 2009 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: Avenue Marnix 17, B - 1000 Brussels 2009 CENELEC - All rights of exploitation in any form and by any mea
7、ns reserved worldwide for CENELEC members. Ref. No. EN 61300-2-1:2009 E ICS 33.180.20 Supersedes EN 61300-2-1:2003English version Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-1: Tests - Vibration (sinusoidal) (IEC 61300-2-1:2009) Disposi
8、tifs dinterconnexion et composants passifs fibres optiques - Mthodes fondamentales dessais et de mesures - Partie 2-1: Essais - Vibrations (sinusodales) (CEI 61300-2-1:2009) Lichtwellenleiter - Verbindungselemente und passive Bauteile - Grundlegende Prf- und Messverfahren - Teil 2-1: Prfungen - Schw
9、ingung (sinusfrmig) (IEC 61300-2-1:2009) This European Standard was approved by CENELEC on 2009-10-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alterati
10、on. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by trans
11、lation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Fi
12、nland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. BS EN 61300-2-1:2009EN 61300-2-1:2009 - 2 - Foreword The text of document
13、 86B/2862/FDIS, future edition 3 of IEC 61300-2-1, prepared by SC 86B, Fibre optic interconnecting devices and passive components, of IEC TC 86, Fibre optics, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 61300-2-1 on 2009-10-01. This European Standard supersedes E
14、N 61300-2-1:2003. Changes from EN 61300-2-1:2003 are to reconsider the severity and the structure of this standard. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2010-07-01
15、latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2010-10-01 Annex ZA has been added by CENELEC. _ Endorsement notice The text of the International Standard IEC 61300-2-1:2009 was approved by CENELEC as a European Standard without any modification. _ BS E
16、N 61300-2-1:2009- 3 - EN 61300-2-1:2009 Annex ZA (normative) Normative references to international publications with their corresponding European publications The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited appli
17、es. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. Publication Year Title EN/HD Year IEC 60068-2-6 -1)Environme
18、ntal testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal) EN 60068-2-6 20082)IEC 61300-1 -1)Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 1: General and guidance EN 61300-1 20032)IEC 61300-3-1 -1)Fibre optic interconnecting devices a
19、nd passive components - Basic test and measurement procedures - Part 3-1: Examinations and measurements - Visual examination EN 61300-3-1 20052)IEC 61300-3-3 -1)Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-3: Examinations and measurement
20、s - Active monitoring of changes in attenuation and return loss EN 61300-3-3 20092)IEC 61300-3-28 -1)Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-28: Examinations and measurements - Transient loss EN 61300-3-28 20022)1)Undated reference.
21、 2)Valid edition at date of issue. BS EN 61300-2-1:2009 2 CONTENTS 1 Scope.5 2 Normative references5 3 General description.5 4 Apparatus .5 4.1 General .5 4.2 Vibration generator 6 4.3 Mounting fixture.6 4.4 Measuring equipment 6 5 Procedure.6 5.1 Preparation of DUT6 5.2 Pre-conditioning 6 5.3 Initi
22、al measurement .6 5.4 Conditioning 6 5.5 Monitoring .6 5.6 Recovery .7 5.7 Final measurements 7 6 Severity 7 7 Details to be specified.8 Figure 1 Example of vibration apparatus .7 Table 1 Connectors and passive components .8 Table 2 Closures 8 BS EN 61300-2-1:2009IEC 61300-2-1:2009 5 FIBRE OPTIC INT
23、ERCONNECTING DEVICES AND PASSIVE COMPONENTS BASIC TEST AND MEASUREMENT PROCEDURES Part 2-1: Tests Vibration (sinusoidal) 1 Scope This part of IEC 61300 evaluates the effects of vibration on fibre optic devices at the predominant frequency ranges and magnitudes that may be encountered during field se
24、rvice. NOTE Most vibrations encountered in service are not of a simple harmonic nature. However, it has been shown that tests based on vibrations of this type are satisfactory to simulating actual service. 2 Normative references The following referenced documents are indispensable for the applicatio
25、n of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 60068-2-6, Environmental testing Part 2-6: Tests Test Fc: Vibration (sinusoidal) IEC 61300-1, Fibre optic interconne
26、cting devices and passive components Basic test and measurement procedures Part 1: General and guidance IEC 61300-3-1, Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 3-1: Examinations and measurements Visual examination IEC 61300-3-3, Fibre opti
27、c interconnecting devices and passive components Basic test and measurement procedures Part 3-3: Examinations and measurements Active monitoring of changes in attenuation and return loss IEC 61300-3-28, Fibre optic interconnecting devices and passive components Basic test and measurement procedures
28、Part 3-28: Examinations and measurements Transient loss 3 General description This procedure is derived from IEC 60068-2-6, test Fc. The device under test (DUT) is mounted on a vibration generator and vibrated with a sinusoidal motion. The DUT is exposed to vibration in three mutually perpendicular
29、directions, one of which is parallel to the optical axis. The vibration amplitude is specified either in terms of constant displacement or constant acceleration. 4 Apparatus 4.1 General The apparatus shall be in accordance with IEC 60068-2-6, test Fc and consists of the following elements. BS EN 613
30、00-2-1:2009IEC 61300-2-1:2009 6 4.2 Vibration generator A vibration generator capable of generating a sinusoidal excitation and its auxiliary test equipment. 4.3 Mounting fixture A suitable DUT mounting fixture capable of transmitting the vibration conditions specified shall be used. The mounting fi
31、xture shall be designed so that the resonant vibration inherent in the fixture shall not have an effect on the specified frequency range. The amplitude and the acceleration of the applied vibration shall be monitored on the test fixture near the DUT mounting points. 4.4 Measuring equipment Unless ot
32、herwise specified, measuring equipment specified in IEC 61300-3-3 shall be connected to the DUT for monitoring the optical performances during the test; moreover the transient loss measuring equipment specified in IEC 61300-3-28 shall be used to detect fast variation of attenuation. 5 Procedure 5.1
33、Preparation of DUT Prepare the DUT according to the manufacturers instructions or as specified in the relevant specification. 5.2 Pre-conditioning Pre-condition the DUT for 2 h at the standard test conditions specified in IEC 61300-1, unless otherwise specified in the relevant specification. 5.3 Ini
34、tial measurement Complete initial examinations and measurements of the DUT as required by the relevant specification. 5.4 Conditioning The DUT shall be mounted rigidly to the fixture in a manner that simulates normal mounting as closely as possible. A minimum of 200 mm of optical fibre/cable shall b
35、e unsupported on both ends of the DUT and be attached free of tension to the vibrating surface. Conduct the procedure in accordance with IEC 60068-2-6, test Fc. The DUT shall be vibrated in three mutually perpendicular axes coincident with the principal axes of the device. If the sample has axial sy
36、mmetry the number of axes to be tested can be reduced to two. The vibration endurance shall be performed by sweeping continuously between minimum and maximum frequency at a specified rate. An example of vibration apparatus test is outlined in Figure 1. 5.5 Monitoring The attenuation and/or return lo
37、ss of the DUT shall be monitored during the test using an x-y-plotter, an oscilloscope or/and a digital data acquisition system for recording as described in IEC 61300-3-28, unless otherwise specified in the relevant specification. Any change in optical performance shall be within the limit given in
38、 the relevant specification. BS EN 61300-2-1:2009IEC 61300-2-1:2009 7 Mounting fixtureDevice under testFibre lead (length 20 cm)To optical monitoring apparatusTo vibration control systemDUT cabling holderAccelerometerVibration generatorIEC 2656/02Figure 1 Example of vibration apparatus 5.6 Recovery
39、Allow the DUT to remain under standard test conditions for 2 h, as defined in IEC 61300-1, unless otherwise specified in the relevant specification. Clean the DUT in accordance with the manufacturers instructions. 5.7 Final measurements On completion of the test, remove all fixtures and make final m
40、easurements, as defined by the relevant specification, to ensure that there is no permanent damage to the DUT. The results of the final measurement shall be within the limit established in the relevant specification. Unless otherwise specified, visually examine the DUT in accordance with IEC 61300-3
41、-1. Check for evidence of any degradation in the DUT. This may include, for example: broken, loose or damaged parts or accessories; breaking or damage to the cable jacket, seals, strain relief, or fibres; displaced, bent, broken or chipped parts. 6 Severity The severity consists of the combination o
42、f frequency range, vibration amplitude, sweep rate and either number of sweeps or endurance duration per axis. The severity shall be specified in the relevant specification. Recommended values of the test parameters are given below in Table 1 and 2. BS EN 61300-2-1:2009IEC 61300-2-1:2009 8 7 Details
43、 to be specified The following details, as applicable, shall be specified in the relevant specification: frequency range; vibration amplitude; number of sweeps; endurance duration per axis; frequency change at constant rate; initial examinations and measurements and performance requirements; examina
44、tions and measurements during test and performance requirements; final examinations and measurements and performance requirements; deviations from test procedure; additional pass/fail criteria. _ BS EN 61300-2-1:2009Table 1 Connectors and passive components Category Parameter Value Frequency range 1
45、0 Hz 55 Hz Sweep rate 1 oct/min Number of sweeps 15/axis Categories C, U and E Amplitude 0,75 mm Frequency range 10 Hz 55 Hz Sweep rate 1 oct/min for passive components 45 Hz/min for connectors Duration 2 h/axis Category O Amplitude 1,52 mm for passive components 0,75 mm for connectors Table 2 Fibre
46、 management systems and closures Category Parameter Value Frequency range 5 Hz 500 Hz Sweep rate 1 oct/min Number of sweeps 10/axis Amplitude 3,5 mm below 9 Hz Categories C, A, G and S Acceleration 9,8 m/s2above 9 Hz IEC 61300-2-1:2009This page deliberately left blankBSI is the independent national
47、body responsible for preparing British Standardsand other standards-related publications, information and services. It presents the UK view on standards in Europe and at the international level. It is incorporated by Royal Charter.British Standards Institution (BSI)raising standards worldwideBSI Gro
48、up Headquarters389 Chiswick High Road London W4 4AL UKTel +44 (0)20 8996 9001Fax +44 (0)20 8996 Standards are updated by amendment or revision. Users of British Stan-dards should make sure that they possess the latest amendments or editions.It is the constant aim of BSI to improve the quality of ou
49、r products and serv-ices. We would be grateful if anyone finding an inaccuracy or ambiguity whileusing this British Standard would inform the Secretary of the technical com-mittee responsible, the identity of which can be found on the inside frontcover.Tel: +44 (0)20 8996 9001 Fax: +44 (0)20 8996 7001BSI offers Members an individual updating service called PLUS which ensurestha
copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1