1、Mechanical structures for electronic equipment Tests for IEC 60917 and IEC 60297 seriesPart 1: Environmental requirements, test set-up and safety aspects for cabinets, racks, subracks and chassis under indoor condition use and transportationBS EN 61587-1:2017BSI Standards PublicationWB11885_BSI_Stan
2、dardCovs_2013_AW.indd 1 15/05/2013 15:06EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 61587-1 April 2017 ICS 31.240 Supersedes EN 61587-1:2012 English Version Mechanical structures for electronic equipment - Tests for IEC 60917 and IEC 60297 series - Part 1: Environmental requirements, test s
3、et-up and safety aspects for cabinets, racks, subracks and chassis under indoor condition use and transportation (IEC 61587-1:2016) Structures mcaniques pour quipement lectronique - Essais pour les sries IEC 60917 et IEC 60297 - Partie 1: Exigences environnementales, montage dessai et aspects lis la
4、 scurit des baies, btis, bacs cartes et chssis dans des conditions dutilisation intrieure ou de transport (IEC 61587-1:2016) Mechanische Bauweisen fr elektronische Einrichtungen - Prfungen fr die Reihen IEC 60917 und IEC 60297 - Teil 1: Umgebungsanforderungen, Prfaufbau und Sicherheitsaspekte fr Sch
5、rnke, Gestelle, Baugruppentrger und Einschbe bei Bedingungen in Innenrumen und beim Transport (IEC 61587-1:2016) This European Standard was approved by CENELEC on 2017-01-11. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this
6、European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member. This European Standard exists in three official
7、 versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CENELEC members are the national electrotechnica
8、l committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Serb
9、ia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
10、 2017 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members. Ref. No. EN 61587-1:2017 E National forewordThis British Standard is the UK implementation of EN 61587-1:2017. It is identical to IEC 61587-1:2016. It supersedes BS EN 61587-1:2012, which is
11、 withdrawn.The UK participation in its preparation was entrusted to Technical Committee EPL/48, Electromechanical components and mechanical structures for electronic equipment.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not
12、purport to include all the necessary provisions of a contract. Users are responsible for its correct application. The British Standards Institution 2017 Published by BSI Standards Limited 2017ISBN 978 0 580 85410 1ICS 31.240Compliance with a British Standard cannot confer immunity from legal obligat
13、ions. This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 May 2017.Amendments/corrigenda issued since publicationDate Text affectedBRITISH STANDARDBS EN 61587-1:2017EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 61587-1 April 2017 ICS 31
14、.240 Supersedes EN 61587-1:2012 English Version Mechanical structures for electronic equipment - Tests for IEC 60917 and IEC 60297 series - Part 1: Environmental requirements, test set-up and safety aspects for cabinets, racks, subracks and chassis under indoor condition use and transportation (IEC
15、61587-1:2016) Structures mcaniques pour quipement lectronique - Essais pour les sries IEC 60917 et IEC 60297 - Partie 1: Exigences environnementales, montage dessai et aspects lis la scurit des baies, btis, bacs cartes et chssis dans des conditions dutilisation intrieure ou de transport (IEC 61587-1
16、:2016) Mechanische Bauweisen fr elektronische Einrichtungen - Prfungen fr die Reihen IEC 60917 und IEC 60297 - Teil 1: Umgebungsanforderungen, Prfaufbau und Sicherheitsaspekte fr Schrnke, Gestelle, Baugruppentrger und Einschbe bei Bedingungen in Innenrumen und beim Transport (IEC 61587-1:2016) This
17、European Standard was approved by CENELEC on 2017-01-11. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical refer
18、ences concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a
19、 CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yug
20、oslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. European Committee for Electrotechn
21、ical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2017 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members. Ref. No.
22、 EN 61587-1:2017 E BS EN 61587-1:2017EN 61587-1:2017 2 European foreword The text of document 48D/623/FDIS, future edition 4 of IEC 61587-1, prepared by SC 48D “Mechanical structures for electrical and electronic equipment” of IEC/TC 48 “Electrical connectors and mechanical structures for electrical
23、 and electronic equipment“ was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as EN 61587-1:2017. The following dates are fixed: latest date by which the document has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2017
24、-10-21 latest date by which the national standards conflicting with the document have to be withdrawn (dow) 2020-04-21 This document supersedes EN 61587-1:2012. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC and/or CEN sh
25、all not be held responsible for identifying any or all such patent rights. Endorsement notice The text of the International Standard IEC 61587-1:2016 was approved by CENELEC as a European Standard without any modification. In the official version, for Bibliography, the following notes have to be add
26、ed for the standards indicated: IEC 60068 (series) NOTE Harmonized as EN 60068 (series). IEC 60068-2-75 NOTE Harmonized as EN 600068-2-75. IEC 62262 NOTE Harmonized as EN 62262. BS EN 61587-1:2017EN 61587-1:2017 2 European foreword The text of document 48D/623/FDIS, future edition 4 of IEC 61587-1,
27、prepared by SC 48D “Mechanical structures for electrical and electronic equipment” of IEC/TC 48 “Electrical connectors and mechanical structures for electrical and electronic equipment“ was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as EN 61587-1:2017. The following dates are
28、 fixed: latest date by which the document has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2017-10-21 latest date by which the national standards conflicting with the document have to be withdrawn (dow) 2020-04-21 This document supersed
29、es EN 61587-1:2012. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC and/or CEN shall not be held responsible for identifying any or all such patent rights. Endorsement notice The text of the International Standard IEC 6158
30、7-1:2016 was approved by CENELEC as a European Standard without any modification. In the official version, for Bibliography, the following notes have to be added for the standards indicated: IEC 60068 (series) NOTE Harmonized as EN 60068 (series). IEC 60068-2-75 NOTE Harmonized as EN 600068-2-75. IE
31、C 62262 NOTE Harmonized as EN 62262. EN 61587-1:2017 3 Annex ZA (normative) Normative references to international publications with their corresponding European publications The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its applic
32、ation. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE 1 When an International Publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. N
33、OTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is available here: www.cenelec.eu. Publication Year Title EN/HD Year IEC 60068-1 - Environmental testing - Part 1: General and guidance EN 60068-1 - IEC 60068-2-1 - Environmental testing - Part 2-1: Te
34、sts - Test A: Cold EN 60068-2-1 - IEC 60068-2-2 - Environmental testing - Part 2-2: Tests - Test B: Dry heat EN 60068-2-2 - IEC 60068-2-6 - Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal) EN 60068-2-6 - IEC 60068-2-11 - Basic environmental testing procedures - Part 2-11: Te
35、sts - Test Ka: Salt mist EN 60068-2-11 - IEC 60068-2-27 - Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock EN 60068-2-27 - IEC 60068-2-30 - Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) EN 60068-2-30 - IEC 60068-2-42 - Environmental t
36、esting - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections EN 60068-2-42 - IEC 60068-2-43 - Environmental testing - Part 2-43: Tests - Test Kd: Hydrogen sulphide test for contacts and connections EN 60068-2-43 - IEC 60068-2-49 - Environmental testing - Part 2: Tests - Gui
37、dance to Test Kc: Sulphur dioxide test for contacts and connections - - IEC 60068-2-52 - Environmental testing - Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution) EN 60068-2-52 - IEC 60068-2-64 - Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband random a
38、nd guidance EN 60068-2-64 - IEC 60297 series Dimensions of mechanical structures of the 482,6 mm (19 in) series - series IEC 60297-3-100 - Mechanical structures for electronic equipment - Dimensions of mechanical structures of the 482,6 mm (19 in) series - Part 3-100: Basic dimensions of front panel
39、s, subracks, chassis, racks and cabinets EN 60297-3-100 - IEC 60297-3-101 - Mechanical structures for electronic equipment - Dimensions of mechanical structures of the 482,6 mm (19 in) series - Part 3-101: Subracks and associated plug-in units EN 60297-3-101 - BS EN 61587-1:2017EN 61587-1:2017 4 IEC
40、 60297-3-107 - Mechanical structures for electronic equipment - Dimensions of mechanical structures of the 482,6 mm (19 in) series - Part 3-107: Dimensions of subracks and plug-in units, small form factor EN 60297-3-107 - IEC 60297-3-108 - Mechanical structures for electronic equipment - Dimensions
41、of mechanical structures of the 482,6 mm (19 in) series - Part 108: Dimensions of R-type subracks and plug-in units EN 60297-3-108 - IEC 60512-1-1 - Connectors for electronic equipment - Tests and measurements - Part 1-1: General examination - Test 1a: Visual examination EN 60512-1-1 - IEC 60529 - D
42、egrees of protection provided by enclosures (IP Code) - - IEC 60654-4 - Operating conditions for industrial-process measurement and control equipment - Part 4: Corrosive and erosive influences EN 60654-4 - IEC 60695-11-10 - Fire hazard testing - Part 11-10: Test flames - 50 W horizontal and vertical
43、 flame test methods EN 60695-11-10 - IEC 60721-3-3 - Classification of environmental conditions - Part 3: Classification of groups of environmental parameters and their severities - Section 3: Stationary use at weatherprotected locations EN 60721-3-3 - IEC 60917 series Modular order for the developm
44、ent of mechanical structures for electronic equipment practices EN 60917 series IEC 60917-2-1 - Modular order for the development of mechanical structures for electronic equipment practices - Part 2: Sectional specification - Interface co-ordination dimensions for the 25 mm equipment practice - Sect
45、ion 1: Detail specification - Dimensions for cabinets and racks EN 60917-2-1 - IEC 60917-2-2 - Modular order for the development of mechanical structures for electronic equipment practices - Part 2: Sectional specification - Interface co-ordination dimensions for the 25 mm equipment practice - Secti
46、on 2: Detail specification - Dimensions for subracks, chassis, backplanes, front panels and plug-in units EN 60917-2-2 - IEC 60917-2-3 - Modular order for the development of mechanical structures for electronic equipment practices - Part 2-3: Sectional specification - Interface co-ordination dimensi
47、ons for the 25 mm equipment practice - Extended detail specification - Dimensions for subracks, chassis, backplanes, front panels and plug-in units EN 60917-2-3 - IEC 60950-1 (mod) 2005 Information technology equipment - Safety - Part 1: General requirements EN 60950-1 2006 - - + A11 2009 + A1 (mod)
48、 2009 + A1 2010 - - + A12 2011 - - + AC 2011 + A2 (mod) 2013 + A2 2013 BS EN 61587-1:2017EN 61587-1:2017 4 IEC 60297-3-107 - Mechanical structures for electronic equipment - Dimensions of mechanical structures of the 482,6 mm (19 in) series - Part 3-107: Dimensions of subracks and plug-in units, sma
49、ll form factor EN 60297-3-107 - IEC 60297-3-108 - Mechanical structures for electronic equipment - Dimensions of mechanical structures of the 482,6 mm (19 in) series - Part 108: Dimensions of R-type subracks and plug-in units EN 60297-3-108 - IEC 60512-1-1 - Connectors for electronic equipment - Tests and measurements - Part 1-1: General examination - Test 1a: Visual examination EN 60512-1-1 - IEC 60529 - Degrees of p