1、BRITISH STANDARD Electric vehicle conductive charging system Part 22: AC electric vehicle charging station The European Standard EN 61851-22:2002 has the status ofa British Standard ICs 43.120 BS EN 6 1 85 1-22 12002 A present to the responsible internationalEuropean committee any enquiries on the i
2、nterpretation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. - A list of organizations represented on this committee can be obtained on request to its secretary. From 1 January 1997, all IEC publica
3、tions have the number 60000 added to the old number. For instance, IEC 27-1 has been renumbered as IEC 60027-1. For a period of time during the change over fi-om one numbering system to the other, publications may contain identifiers from both systems. Cros s-r e fer en ces The British Standards whi
4、ch implement international or European publications referred to in this document may be found in the BSI Standards Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Find” facility of the BSI Standards Electronic Catalogue. A British Standard does n
5、ot purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside
6、front cover, the EN title page, pages 2 to 23, and a back cover. The BSI copyright date displayed in this document indicates when the document was last issued. O BSI 20 May 2002 ISBN O 580 39632 O EUROPEAN STANDARD EN 61851-22 NORME EUROPENNE EUROPISCHE NORM Januaw 2002 ICs 43.120 English version El
7、ectric vehicle conductive charging system Part 22: AC electric vehicle charging station (IEC 61 851 -2212001) Systme de charge conductive pour vhicules lectriques Partie 22: Borne de charge conductive en courant alternatif pour vhicules lectriques (CE1 61851-2212001) Kondu ktive Ladesysteme f U r E
8、le kt rofa h rze u g e Te I 22 : W ec hse Istro m -Lad estat io n f U r E le kt rofa h rze u g e (I E C 6 1 85 1 -22 120 O 1 ) This European Standard was approved by CENELEC on 2001-12-04. CENELEC members are bound to comply with the CENKENELEC Internal Regulations which stipulate the conditions for
9、 giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three offic
10、ial versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the oficial versions. CENELEC members are the national electrotechnical commit
11、tees of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom. CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisatio
12、n Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels O 2002 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 61851-22:2002 E Page 2 EN 61851-222002 Foreword
13、The text of document 69/129/FDIS, future edition 1 of IEC 61851-22, prepared by IEC TC 69, Electric road vehicles and electric industrial trucks, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 61851-22 on 2001-12-04. The following dates were fixed: - latest date by
14、which the EN has to be implemented at national level by publication of an identical national standard or by endorsement - latest date by which the national standards conflicting with the EN have to be withdrawn This European Standard shall be read in conjunction with EN 61851-1 Annexes designated “n
15、ormative“ are part of the body of the standard. In this standard, annex ZA is normative. Annex ZA has been added by CENELEC. (dop) 2002-10-01 (dow) 2005-01-01 En dorse ment not i ce The text of the International Standard IEC 61851-22:2001 was approved by CENELEC as a European Standard without any mo
16、dification. In the official version, for Bibliography, the following notes have to be added for the standards indicated: IEC 60309-1 NOTE Harmonized as EN 60309-1:1999 (not modified) IEC 60364-5-54 NOTE Harmonized as HD 384.5.54 S1:1988 (modified). CISPR 11 NOTE Harmonized as EN 55011:1998 (modified
17、). CISPR 14 NOTE Harmonized as EN 55014 Series (not modified) O BSI 20 May 2002 Page 3 EN 61851-222002 CONTENTS 1 2 3 4 5 6 7 8 9 10 11 Scope Norm at ive references . . . 7 General requirements . 7 Standard conditions for o Rating of the a.c. input and output . General test requirements. . Functiona
18、l and constructional requirements . 8.1 Control functions 8.2 Emergency service . 8.3 Permissible surface temperature 8.4 Charging station prot 8.5 Storage means for th 8.6 Location of the socket-outlet and storage means for the connector 8.7 Extension cord 8.8 Metering . Electrica I safety . 9.1 Pr
19、otection against indirect contact 9.2 Earthing electrode and continuity 7 7 9.3 Detection of the elec Dielectric test requirements . 10.1 Dielectric withstan . IO 10.1 .I Dielectric withstand voltage . . IO 10.1.2 Impulse diel . II 10.1.3 Insulation resistance . . II 10.2 Touch current . . II 10.3 P
20、rotection measures . . 12 10.4 Creepage and clearance distances . . 12 Environmental tests . . 12 11 .I Climatic environmental tests . . 12 11 .I .I General . 12 11 .I .2 Ambient air temperature . 12 11 .I .3 Dry heat . 12 11 .I .4 Ambient humidity . . 12 1 1 .I .5 Cold test . 13 11 .I .6 Ambient ai
21、r pressure . 13 11 .I .7 Solar radiation (optional) . . 13 11 .I .8 Saline mist (optional) . 13 O BSI 20 May 2002 Page 4 EN 61851-222002 11.2 Mechanical environmental tests . 11.2.1 General . . 11.2.2 Mechanical impact . . 11.2.3 Stability . . 11.3 Electromagnetic environmental tests . 11.3.1 Immuni
22、ty to EM disturbances 11.3.2 Immunity to electrostatic discharges 11.3.3 Emitted EM disturbances . 12 Specific socket-outlet/connector requir ts 13 Classification . 14 Marking and instructions . . 14.1 Connection instructions . 14.2 Legibility . 14.3 Marking of a.c. electric vehicle chargi . . . Bib
23、liography .20 17 18 18 8 Figure 1 - Limit levels of conducted emission (a.c. input terminal) Figure 3 - Limit levels of radiated emission Table 1 -Values of output voltage and current rating . Table 2 - Touch current limits . . II corresponding European publications Figure 2 - Limit levels of conduc
24、ted emission (signal 110 and control) . Annex ZA (normative) Normative references to international publications with their . 21 O BSI 20 May 2002 Page 5 EN 61851-222002 ELECTRIC VEHICLE CONDUCTIVE CHARGING SYSTEM - Part 22: AC electric vehicle charging station 1 Scope This part of IEC 61851, togethe
25、r with part 1, gives the requirements for a.c. electric vehicle charging stations for conductive connection to an electric vehicle, with a.c. supply voltages according to IEC 60038 up to 690 V. This standard does not cover all safety aspects related to maintenance. The scope of this part of IEC 6185
26、1 does not cover box type assemblies with socket-outlets, installed for the purpose of delivering energy to the vehicle, which have no charging control functions. 2 Normative references The following normative documents contain provisions which, through reference in this text, constitute provisions
27、of this part of IEC 61851. For dated references, subsequent amendments to, or revisions of, any of these publications do not apply. However, parties to agreements based on this part of IEC 61851 are encouraged to investigate the possibility of applying the most recent editions of the normative docum
28、ents indicated below. For undated references, the latest edition of the normative document referred to applies. Members of IS0 and IEC maintain registers of currently valid International Standards. IEC 60038:1983, IEC sfandard volfages IEC 60068-2-1 :I 990, Environmenfal fesfing - Parf 2: Tesfs - Te
29、sfs A: Cold IEC 60068-2-2:1974, Environmenfal fesfing - Parf 2: Tesfs - Tesfs 6: Dry heaf IEC 60068-2-3:1969, Environmenfal fesfing - Parf 2: Tesfs - Tesf Ca: Damp heaf, sfeady sfafe IEC 60068-2-5:1975, Environmenfal fesfing - Parf 2: Tesfs - Tesf Sa: Simulafed solar radiafion af ground level IEC 60
30、068-2-14:1984, Environmenfal fesfing - Parf 2: Tesfs - Tesf N: Change of femperafure IEC 60068-2-30:1980, Environmenfal fesfing - Parf 2: Tesfs - Tesf Db and guidance: Damp heaf, cyclic (12 + 12-hour cycle) IEC 60068-2-52:1996, Environmenfal fesfing - Parf 2: Tesfs - Tesf Kb: Salf misf, cyclic (sodi
31、um chloride solufion) O BSI 20 May 2002 Page 6 EN 61851-222002 IEC 60068-2-75:1997, Environmenfal fesfing - Parf 2: Tesfs - Tesf Eh: Hammer fesfs IEC 60364-4-43:1977, Elecfrical insfallafions of buildings - Parf 4: Profecfion for safefy - Chapfer 43: Profecfion againsf overcurrenf IEC 60364-4-443:19
32、95, Elecfrical insfallafions of buildings - Parf 4: Profecfion for safefy - Chapfer 44: Profecfion againsf overvolfages - Secfion 443: Profecfion againsf overvolfages of afmospheric origin or due fo swifching Amendment 1 (1998) 1) IEC 60439-1 :I 999 Low-volfage swifchgear and confrolgear assemblies
33、- Parf 1: Type-fesfed and parfially fype-fesfed assemblies IEC 60529:1989, Degrees of profecfion provided by enclosures (IP Code) IEC 60664-1 :I 992, Insulafion coordinafion for equipmenf wifhin low-volfage sysfems - Parf 1: Principles, requiremenfs and fesfs IEC 60950:1999, Safefy of informafion fe
34、chnology equipmenf IEC 61 000-2-2:1990, Elecfromagnefic compafibilify (EMC) - Parf 2: Environmenf - Compafi- bilify levels for low-frequency conducfed disfurbances and signalling in public low-volfage power supply sysfems IEC 61 000-3-2:2000, Elecfromagnefic compafibilify (EMC) - Parf 3-2: Limifs -
35、Limifs for harmonic currenf emissions (equipmenf inpuf currenf 116 A per phase) IEC 61 000-4-1 :2000, Elecfromagnefic compafibilify (EMC) - Parf 4-1: Tesfing and measure- menf fechniques - Overview of IEC 61000-4 series IEC 61 000-4-2:1995, Elecfromagnefic compafibilify (EMC) - Parf 4-2: Tesfing and
36、 measuremenf fechniques - Secfion 2: Elecfrosfafic discharge immunify fesf - Basic EMC publicafion 2) Amendment 1 (1998) Amendment 2 (2000) IEC 61 000-4-3:1995, Elecfromagnefic compafibilify (EMC) - Parf 4: Tesfing and measuremenf fechniques - Secfion 3: Radiafed, radio-frequency, elecfromagnefic fi
37、eld immunify fesf 3) Amendment 1 (1998) Amendment 2 (2000) IEC 61 000-4-4:1995, Elecfromagnefic compafibilify (EMC) - Parf 4: Tesfing and measuremenf fechniques - Secfion 4: Elecfrical fasf fransienflbursf immunify fesf - Basic EMC publicafion Amendment 1 (2000) IEC 61 000-4-5:1995, Elecfromagnefic
38、compafibilify (EMC) - Parf 4: Tesfing and measuremenf fechniques - Secfion 5: Surge immunify fesf 1) There exists a consolidated edition 2.1 (1999) that includes IEC 60364-4-443 (1995) and its amendment 1 (1998). 2) There exists a consolidated edition 1.1 (1999) that includes IEC 61000-4-2 (1995) an
39、d its amendment 1 (1998). 3) There exists a consolidated edition 1.1 (1998) that includes IEC 61000-4-3 (1995) and its amendment 1 (1998). O BSI 20 May 2002 Page 7 EN 61851-222002 IEC 61 000-4-1 1 :I 994, Elecfromagnefic compafibilify (EMC) - Parf 4: Tesfing and measuremenf fechniques - Secfion 1 1:
40、 Volfage dips, shorf inferrupfions and volfage variafions immunify fesfs IEC 61 036:1996, Alfernafing currenf sfafic waff-hour mefers for acfive energy (Classes 1 and 2) IEC 61 180-1 :I 992, High-volfage fesf fechniques for low-volfage equipmenf - Parf 1: Definifions, fesf and procedure requiremenfs
41、 CISPR 16 (all parts), Specificafion for radio disfurbance and immunify measuring apparafus and mefhods CISPR 22: 1997, Informafion fechnology equipmenf - Radio disfurbance characferisfics - Limifs and mefhods of measuremenf 3 Definitions Clause 3 of part 1 applies. Additional definitions relating t
42、o this part of the standard are under consideration. 4 General requirements The connection of electric vehicles can be made by one or more of the methods described in part 1. The a.c. electric vehicle charging station may have one or more socket-outletshehicle connectors. The a.c. electric vehicle c
43、harging station shall be connected to the electric vehicle so that in normal conditions of use the equipment operates to reduce the risk of fire, electric shock or injury to persons, either indoors or outdoors. In general, this is achieved by fulfilling the relevant requirements specified in this st
44、andard and compliance is checked by carrying out all relevant tests. General requirements for the a.c. electric vehicle charging station can also be found in IEC 60439-1. 5 Standard conditions for operation in service and for installation The rated value of the a.c. supply voltage is up to 690 V. Th
45、e equipment shall operate correctly within I10 % of the standard nominal voltage (see IEC 60038). The rated value of the frequency is 50 Hz f 1 % or 60 Hz f 1 %. The ambient temperature range during charging may be between -30 “C and +50 “C and at a relative humidity of between 5 % and 95 %. NOTE Na
46、tional codes and regulations may require different operating temperature ranges. 6 Rating of the a.c. input and output The input voltage and current rating is according to IEC 60038. The output voltage and current rating shall not exceed the values given in table 1. Lower current values may be used.
47、 O BSI 20 May 2002 Page 8 EN 61851-222002 A B Table 1 -Values of output voltage and current rating Single-phase, 230 V, 32 A Single/three-phase, 230/400 V, 32 A I Output option I AC output I I C I Three-phase, 500 V, 250 A I 7 General test requirements 7.1 All tests in this standard are type tests.
48、7.2 Unless otherwise specified, type tests shall be carried out on a single specimen as delivered and configured in accordance with the manufacturers instructions. 7.3 The tests in 11.3 may be conducted on separate samples at the discretion of the manufacturer. Unless otherwise specified, all other
49、tests shall be carried out in the order of the clauses and subclauses in this part. 7.4 The tests shall be carried out with the specimen, or any movable part of it, placed in the most unfavourable position which may occur in normal use. 7.5 an ambient temperature of 20 “C f 5 “C. Unless otherwise specified, the tests shall be carried out in a draught-free location and at 7.6 The characteristics of the test voltages in 10.1 shall comply with IEC 61 180-1 8 Functional and constructional requirements 8.1 Control functions For mode 3 charging, the a.c. electric vehicle