1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationLow-voltage switchgear and controlgear Device profiles for networked industrial devicesPart 2: Root device profiles for starters and similar equipmentBS EN 61915-2:2012Incorporat
2、ing corrigendum July 2012BS EN 61915-2:2012National forewordThis British Standard is the UK implementation of EN 61915-2:2012. It is identical to IEC 61915-2:2011, incorporating corrigendum July 2012.The start and finish of text introduced or altered by corrigendum is indicated in the text by tags.
3、Text altered by IEC corrigendum July 2012 is indicated in the text by .A list of organizations represented on this subcommittee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct a
4、pplication. The British Standards Institution 2012.Published by BSI Standards Limited 2012.ISBN 978 0 580 80314 7 ICS 29.130.20 Compliance with a British Standard cannot confer immunity from legal obligations.This British Standard was published under the authority of the Standards Policy and Strateg
5、y Committee on 30 April 2012.Amendments/corrigenda issued since publicationDate Text affected30 2012 Implementation of IEC corrigendum July 2012BRITISH STANDARDThe UK participation in its preparation was entrusted by Technical Committee PEL/17, Switchgear, controlgear, and HV-LV co-ordination, to Su
6、bcommittee PEL/17/2, Low voltage switchgear and controlgear.NovemberEUROPEAN STANDARD EN 61915-2 NORME EUROPENNE EUROPISCHE NORM March 2012 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung
7、 Management Centre: Avenue Marnix 17, B - 1000 Brussels 2012 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 61915-2:2012 E ICS 29.130 English version Low-voltage switchgear and controlgear - Device profiles for networked industri
8、al devices - Part 2: Root device profiles for starters and similar equipment (IEC 61915-2:2011) Appareillage basse tension - Profils dappareil pour les appareils industriels mis en rseau - Partie 2: Profils racines dappareil pour les dmarreurs et les matriels similaires (CEI 61915-2:2011) Niederspan
9、nungsschaltgerte - Gerteprofile fr vernetzte industrielle Schaltgerte - Teil 2: Grundlegende Gerteprofile fr Starter und hnliche Betriebsmittel (IEC 61915-2:2011) This European Standard was approved by CENELEC on 2011-11-24. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulatio
10、ns which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC membe
11、r. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions
12、. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Ro
13、mania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. Foreword The text of document 17B/1752/FDIS, future edition 1 of IEC 61915-2, prepared by SC 17B, “Low-voltage switchgear and controlgear“, of IEC/TC 17, “Switchgear and controlgear“ was submitted to the IEC-CENELE
14、C parallel vote and approved by CENELEC as EN 61915-2:2012. The following dates are fixed: latest date by which the document has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2012-08-24 latest date by which the national standards conflic
15、ting with the document have to be withdrawn (dow) 2014-11-24 Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC and/or CEN shall not be held responsible for identifying any or all such patent rights. Endorsement notice The te
16、xt of the International Standard IEC 61915-2:2011 was approved by CENELEC as a European Standard without any modification. In the official version, for Bibliography, the following notes have to be added for the standards indicated: IEC 60947 series NOTE Harmonized in EN 60947 series. IEC 60947-4-1:2
17、009 NOTE Harmonized as EN 60947-4-1:2010 (not modified). IEC 60947-4-2:2011 NOTE Harmonized as EN 60947-4-2:201X1)(not modified). IEC 60947-4-3:1999 + A1:2006 + A2:2011 NOTE Harmonized as EN 60947-4-3:2000 + A1:2006 + A2:2011 (not modified). IEC 60947-6-2:2002 + A1:2007 NOTE Harmonized as EN 60947-6
18、-2:2003 + A1:2007 (not modified). IEC 60947-8:2003 + A1:2006 + A2:2011 NOTE Harmonized as EN 60947-8:2003 + A1:2006 + A2:201X1)(not modified). 1)To be published. BS EN 61915-2:2012 EN 61915-2:2012 (E)Annex ZA (normative) Normative references to international publications with their corresponding Eur
19、opean publications The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendment
20、s) applies. NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. Publication Year Title EN/HD Year IEC 60947-1 + A1 2007 2010 Low-voltage switchgear and controlgear - Part 1: General rules EN 60947-1 + A1 2007 2011 IEC 6191
21、5-1 2007 Low-voltage switchgear and controlgear - Device profiles for networked industrial devices - Part 1: General rules for the development of device profiles EN 61915-1 2008 BS EN 61915-2:2012 EN 61915-2:2012 (E)CONTENTS INTRODUCTION . 5 1 Scope . . 6 2 Normative references . 6 3 Terms, definiti
22、ons and abbreviated terms . 6 3.1 General . 6 3.2 Terms and definitions . 6 3.3 Abbreviated terms . 9 4 Root device profiles . 9 5 Common elements of the root device profile . 11 5.1 R parameters . . 11 5.2 RW parameters . 17 5.3 Parameter groups 20 5.4 State model 22 5.4.1 Motor starter . 22 5.4.2
23、Soft starter . 24 5.4.3 Motor management starter . 24 6 Root device profiles . . 27 6.1 Assemblies supported 27 6.2 Motor starter . 28 6.3 Soft starter . 31 6.4 Motor management starter 33 7 Tests . 35 Bibliography . 36 Figure 1 State chart diagram of motor starter . 22 Figure 2 State chart diagram
24、of motor management starter . 24 Table 1 List of root device profiles . 9 Table 2 R parameters . . 11 Table 3 RW parameters . 17 Table 4 Parameters groups . 20 Table 5 State transition table of motor starter 23 Table 6 State transition table of motor management starter . . 25 Table 7 P(IEC 61915-2)0
25、0001 . 28 Table 8 P(IEC 61915-2)00002 . 31 Table 9 P(IEC 61915-2)00003 . 33 BS EN 61915-2:2012 61915-2 IEC:2011 5 INTRODUCTION This International Standard follows the rules and uses the framework of IEC 61915-1, Low-voltage switchgear and controlgear Device profiles for networked industrial devices
26、Part 1: General rules for the development of device profiles. This International Standard is to define the common set of functionality (data and behaviour) for motor starters and similar devices thereby allowing system designers, system integrators and maintenance personnel to handle profile-based d
27、evices without a special tool configuration. This International Standard gives manufacturers and other organizations the common set of functionality to represent their network capable devices. Manufacturers or other organizations may use the root device profiles specified to add their manufacturer-s
28、pecific extensions. BS EN 61915-2:2012 61915-2 IEC:2011 6 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR DEVICE PROFILES FOR NETWORKED INDUSTRIAL DEVICES Part 2: Root device profiles for starters and similar equipment 1 Scope This part of IEC 61915 specifies root device profiles as defined by IEC 61915-1 fo
29、r starters and similar equipment covered by the following product standards: electromechanical contactors and motor-starters (IEC 60947-4-1), AC semiconductor motor controllers and starters (IEC 60947-4-2), AC semiconductor controllers and contactors for non-motor loads (IEC 60947-4-3), control and
30、protective switching devices (or equipment) (CPS) (IEC 60947-6-2), control units for built-in thermal protection (PTC) for rotating electrical machines (IEC 60947-8). 2 Normative references The following referenced documents are indispensable for the application of this document. For dated reference
31、s, only the edition cited applies. For undated references, the latest edition of the referenced document (including amendments) applies. IEC 60947-1:2007, Low-voltage switchgear and controlgear Part 1: General rules Amendment 1 (2010) IEC 61915-1:2007, Low-voltage switchgear and controlgear Device p
32、rofiles for networked industrial devices Part 1: General rules for the development of device profiles 3 Terms, definitions and abbreviated terms 3.1 General For the purposes of this document, the terms, definitions, abbreviations and symbols given in IEC 61915-1, as well as the following apply. 3.2
33、Terms and definitions 3.2.1 built-in thermal protection protection of certain parts (called protected parts) of a rotating electrical machine against excessive temperatures resulting from certain conditions of thermal overload, achieved by means of a thermal protection system, the whole or part of w
34、hich is a thermally sensitive device (thermal detector or protector) incorporated within the machine IEC 60947-8:2003, 3.1.1, modified 3.2.2 thermal protection system system intended to ensure the built-in thermal protection of a rotating electrical machine by means of a thermal detector (or thermal
35、 detectors) together with a control system, or by means of a thermal protector (or thermal protectors) BS EN 61915-2:2012 61915-2 IEC:2011 7 IEC 60947-8:2003, 3.1.2, modified 3.2.3 thermal detector electrical insulated device (component), sensitive to temperature only, which will initiate a switchin
36、g function in the control system when its temperature reaches a predetermined level IEC 60947-8:2003, 3.1.3 3.2.4 control system system to translate a particular point on the characteristic of a thermal detector to a switching function on the supply to the rotating electrical machine NOTE The system
37、 is capable of being reset (either manually or automatically) when the temperature falls to the reset value. IEC 60947-8:2003, 3.1.5 3.2.5 control unit device which converts into a switching function the variation of the characteristic of a thermal detector NOTE A control unit may be an electromecha
38、nical type, a static type or a combination of both. IEC 60947-8:2003, 3.1.15, modified 3.2.6 manufacturer any person, company or organisation with ultimate responsibility as follows: to verify compliance with the appropriate standard or standards; to provide the product information according to Clau
39、se 5 of IEC 60947-1:2007 NOTE For instance, in the case of “protected starters” assembled according to the instructions of the component providers, the manufacturer will be the entity that undertook the assembly. IEC 60947-1:2007, 2.1.21, modified 3.2.7 switching device device designed to make and/o
40、r break the current in one or more electric circuits IEC 60050-441:1984, 441-14-01, modified 3.2.8 semiconductor switching device switching device designed to make and/or break the current in an electric circuit by means of the controlled conductivity of a semiconductor IEC 60050-441:1984, 441-14-03
41、, modified 3.2.9 (mechanical) contactor mechanical switching device having only one position of rest, operated otherwise than by hand, capable of making, carrying and breaking currents under normal circuit conditions including operating overload conditions NOTE Contactors may be designated according
42、 to the method by which the force for closing the main contacts is provided. BS EN 61915-2:2012 61915-2 IEC:2011 8 IEC 60050-441:1984, 441-14-33 3.2.10 semiconductor contactor solid-state contactor device which performs the function of a contactor by utilizing a semiconductor switching device NOTE A
43、 semiconductor contactor may also contain mechanical switching devices. IEC 60947-1:2007, 2.2.13 3.2.11 starter combination of all the switching means necessary to start and stop a motor, in combination with suitable overload protection NOTE Starters may be designated according to the method by whic
44、h the force for closing the main contacts is provided. IEC 60050-441:1984, 441-14-38 3.2.12 short-circuit protective device SCPD device intended to protect a circuit or parts of a circuit against short-circuit currents by interrupting them IEC 60947-1:2007, 2.2.21 3.2.13 tripping (operation) opening
45、 operation of a mechanical switching device initiated by a relay or release IEC 60947-1:2007, 2.4.22 3.2.14 switchgear and controlgear general term covering switching devices and their combination with associated control, measuring, protective and regulating equipment, also assemblies of such device
46、s and equipment with associated interconnections, accessories, enclosures and supporting structures IEC 60050-441:1984, 441-11-01 3.2.15 motor management starter starter including extended functions and with communication ability NOTE Some extended functions are described in IEC 60947-1. 3.2.16 remo
47、te control control of an operation at a point distant from the controlled switching device IEC 60050-441:1984, 441-16-07 NOTE Remote control, in the context of this standard, means control by any communication system using the profiles defined in this standard. BS EN 61915-2:2012 61915-2 IEC:2011 9
48、3.2.17 local control control of an operation at a point on or adjacent to the controlled switching device IEC 60050-441:1984, 441-16-06 NOTE Local control, in the context of this standard, means the indication to a remote host controller that, as a result of operator intervention, commands received
49、will not be accepted or acted upon. Safety control functions may still be active. 3.2.18 manual control control of an operation by human intervention IEC 60050-441:1984, 441-16-04 3.2.19 manual mode switching commands are not accepted from the regular remote controller but from a manual secondary source for the purpose for example of maintenance, test, commissioning or configuring NOTE 1 Manual mode, in the context of this standard, means that t