1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationPassive RF and microwave devices, intermodulation level measurementPart 3: Measurement of passive intermodulation in coaxial connectorsBS EN 62037-3:2012National forewordThis Bri
2、tish Standard is the UK implementation of EN 62037-3:2012. It is identical to IEC 62037-3:2012. Together with BS EN 62037-1:2012, BS EN 62037-2:2013, BS EN 62037-4:2012, BS EN 62037-5:2013 and BS EN 62037-6:2013, it supersedes BS EN 62037:2000, which will be withdrawn on 15 July 2015.The UK particip
3、ation in its preparation was entrusted to Technical Committee EPL/46, Cables, wires and waveguides, radio frequency connectors and accessories for communication and signalling.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not
4、purport to include all the necessary provisions of a contract. Users are responsible for its correct application. The British Standards Institution 2013.Published by BSI Standards Limited 2013.ISBN 978 0 580 58418 3 ICS 33.040.20Compliance with a British Standard cannot confer immunity from legal ob
5、ligations.This British Standard was published under the authority of the Standards Policy and Strategy Committee on 30 April 2013.Amendments issued since publicationDate Text affectedBRITISH STANDARDBS EN 62037-3:2012EUROPEAN STANDARD EN 62037-3 NORME EUROPENNE EUROPISCHE NORM September 2012 CENELEC
6、 European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Management Centre: Avenue Marnix 17, B - 1000 Brussels 2012 CENELEC - All rights of exploitation in any form and by any means reserved worldwide f
7、or CENELEC members. Ref. No. EN 62037-3:2012 E ICS 33.040.20 Supersedes EN 62037:1999 (partially)English version Passive RF and microwave devices, intermodulation level measurement - Part 3: Measurement of passive intermodulation in coaxial connectors (IEC 62037-3:2012) Dispositifs RF et micro-ondes
8、 passifs, mesure du niveau dintermodulation - Partie 3: Mesure de lintermodulation passive dans les connecteurs coaxiaux (CEI 62037-3:2012) Passive HF- und Mikrowellenbauteile, Messung des Intermodulationspegels - Teil 3: Messung der passiven Intermodulation in koaxialen Steckverbindern (IEC 62037-3
9、:2012) This European Standard was approved by CENELEC on 2012-08-28. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliogra
10、phical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the respons
11、ibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland
12、, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 62037-3:2012EN 62037-3:20
13、12 Foreword The text of document 46/417/FDIS, future edition 1 of IEC 62037-3, prepared by IEC TC 46 “Cables, wires, waveguides, R.F. connectors, R.F. and microwave passive components and accessories“ was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as EN 62037-3:2012. The foll
14、owing dates are fixed: latest date by which the document has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2013-05-28 latest date by which the national standards conflicting with the document have to be withdrawn (dow) 2015-08-28 This do
15、cument supersedes EN 62037:1999 (PART). Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC and/or CEN shall not be held responsible for identifying any or all such patent rights. Endorsement notice The text of the Internation
16、al Standard IEC 62037-3:2012 was approved by CENELEC as a European Standard without any modification. BS EN 62037-3:2012EN 62037-3:2012 Annex ZA (normative) Normative references to international publications with their corresponding European publications The following documents, in whole or in part,
17、 are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE When an international publication has been modi
18、fied by common modifications, indicated by (mod), the relevant EN/HD applies. Publication Year Title EN/HD Year IEC 62037-1 - Passive RF and microwave devices, intermodulation level measurement - Part 1: General requirements and measuring methods EN 62037-1 - IEC 62037-4 - Passive RF and microwave d
19、evices, intermodulation level measurement - Part 4: Measurement of passive intermodulation in coaxial cables EN 62037-4 - BS EN 62037-3:201262037-3 IEC:2012(E) CONTENTS 1 Scope . . 5 2 Normative references . 5 3 Abbreviations . 5 4 Test method . 5 4.1 Samples for testing . 5 4.2 Connection of unit .
20、 6 4.3 Setup 1 Fixed frequency test considerations . 6 4.4 Setup 2 considerations . 6 4.5 Impacts . 6 5 Report . 8 Figure 1 Impact test illustration . 7 Figure 2 Impact device . 7 Table 1 Impact information for some popular connectors 7 BS EN 62037-3:201262037-3 IEC:2012(E) 5 PASSIVE RF AND MICROWAV
21、E DEVICES, INTERMODULATION LEVEL MEASUREMENT Part 3: Measurement of passive intermodulation in coaxial connectors 1 Scope This part of IEC 62037 defines the impact test on coaxial connectors to evaluate their robustness against weak connections and particles inside the connector as independently as
22、possible from the effects of cable PIM (passive intermodulation). For other connectors (e.g. panel mounted connectors), the cable can be replaced by an adequate transmission-line (e.g. airline, stripline). In order to evaluate the effects of mechanical stresses on the connectors, a series of impacts
23、 is applied to the connectors while measuring the PIM. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest
24、edition of the referenced document (including any amendments) applies. IEC 62037-1, Passive r.f. and microwave devices, intermodulation level measurement Part 1: General requirements and measuring methods1IEC 62037-4, Passive r.f. and microwave devices, intermodulation level measurement Part 4: Meas
25、urement of passive intermodulation in coaxial cables23 Abbreviations DUT Device under test IM Intermodulation PIM Passive intermodulation 4 Test method 4.1 Samples for testing One of two setups may be used. NOTE Correct assembly methods and techniques are critical to the proper operation of the conn
26、ector on the cable. _ 1To be published. 2To be published. BS EN 62037-3:2012 6 62037-3 IEC:2012(E) a) Setup 1 Multi-port DUT In order to minimize the effect of the transmission line, a short assembly should be tested. Identical connectors should be assembled to each end. An assembly, as short as phy
27、sically practical, should be constructed. b) Setup 2 One port DUT A single connector can be assembled on a length of transmission line for which it is designed, loss or low loss, that exhibits at least 10 dB of attenuation in one direction at the lowest frequency in the receive band. 4.2 Connection
28、of unit The unit should be connected as described in the IEC 62307-1 base document. 4.3 Setup 1 Fixed frequency test considerations Due to the phase interaction of the connectors and the length of the transmission line (configuration A) when measured in the reverse (reflected) mode, the frequency at
29、 which maximum PIM occurs within the band can vary and shall be determined. An accepted method of sweeping is to fix F1 at the low end of the transmit band and step F2 down, starting at the top of the band for all combination of frequencies that result in IM in the receive band. If desired, this pro
30、cedure can be reversed by fixing F1 at the highest frequency in the transmit band and then stepping F2 up, starting at the bottom of the band. If fixed frequency is used, assemblies of varying lengths shall be made to ensure that the PIM adds in-phase. Assemble 2 additional DUTs. The first one is to
31、 be /6 longer and the second one is to be /3 longer at the receive frequency of test. The PIM of the three (3) assemblies is measured to determine which DUT exhibits maximum PIM. The impact test shall be performed on this DUT. Multiple fixed frequency may be used in lieu of varying the cable length.
32、 The impact test is to be conducted at the frequency where the maximum PIM is measured. The cable used as a load should be verified as having suitable PIM performance prior to being used in testing as measured by IEC 62037-4. 4.4 Setup 2 considerations The cable used as a load should be verified as
33、having suitable PIM performance prior to being used in testing as measured by IEC 62037-4. 4.5 Impacts Mount the DUT as shown in Figure 1. A minimum of five (5) impacts in accordance with Table 1 should be applied. (See Figure 1 for impact setup and Figure 2 for description of drop mass and tube.) T
34、he tube should be vertical to the axis of the DUT to 3. The points of impact should cover as many different areas along the length of the connector as possible, but it is not necessary to rotate or otherwise disconnect and reposition the DUT. The PIM is measured prior to, during, and after the impac
35、t. BS EN 62037-3:201262037-3 IEC:2012(E) 7 Table 1 Impact information for some popular connectors Connector interface Mass (min.) g Drop height (min.) mm 7-16 30 300 N 30 300 TNC 30 300 SMA 30 300 The length dimension of the brass rod shall be greater than its diameter. The given values are guidelin
36、es, and other connectors can be used as determined between customer and supplier. (Pine) DUT PIM test setup Drop height Tube does not touch DUT Drop mass PIM setup per IEC 62037-1 PIM test setup IEC 1533/12 Figure 1 Impact test illustration Brass rod, flat ends: See Table 1 for mass. Tube: Any mater
37、ial IEC 1534/12 Figure 2 Impact device BS EN 62037-3:2012 8 62037-3 IEC:2012(E) 5 Report The report should document the height, mass, and distance dropped if different from the table and the PIM values prior to each impact, during impact, and after impact. _ BS EN 62037-3:2012This page deliberately
38、left blankBSI is the independent national body responsible for preparing British Standards and other standards-related publications, information and services. It presents the UK view on standards in Europe and at the international level. BSI is incorporated by Royal Charter. British Standards and ot
39、her standardisation products are published by BSI Standards Limited.British Standards Institution (BSI)raising standards worldwideBSI389 Chiswick High Road London W4 4AL UKTel +44 (0)20 8996 9001Fax +44 (0)20 8996 Standards and PASs are periodically updated by amendment or revision. Users of Britis
40、h Standards and PASs should make sure that they possess the latest amendments or editions.It is the constant aim of BSI to improve the quality of our products and services. We would be grateful if anyone finding an inaccuracy or ambiguity while using British Standards would inform the Secretary of t
41、he technical committee responsible, the identity of which can be found on the inside frontcover. Similary for PASs, please notify BSI Customer Services.Tel: +44 (0)20 8996 9001 Fax: +44 (0)20 8996 7001BSI offers BSI Subscribing Members an individual updating service called PLUS which ensures that su
42、bscribers automatically receive the latest editions of British Standards and PASs.Tel: +44 (0)20 8996 7669 Fax: +44 (0)20 8996 7001Email: Buying standardsYou may buy PDF and hard copy versions of standards directly using acredit card from the BSI Shop on the website addition all orders for BSI, int
43、ernational and foreign standards publicationscan be addressed to BSI Customer Services.Tel: +44 (0)20 8996 9001 Fax: +44 (0)20 8996 7001Email: In response to orders for international standards, BSI will supply the British Standard implementation of the relevant international standard, unless otherwi
44、se requested.Information on standardsBSI provides a wide range of information on national, Europeanand international standards through its Knowledge Centre.Tel: +44 (0)20 8996 7004 Fax: +44 (0)20 8996 7005Email: BSI Subscribing Members are kept up to date with standards developments and receive subs
45、tantial discounts on the purchase priceof standards. For details of these and other benefits contact Membership Administration. Tel: +44 (0)20 8996 7002 Fax: +44 (0)20 8996 7001 Email: Information regarding online access to British Standards and PASs via British Standards Online can be found at in
46、formation about British Standards is available on the BSI website at www.bsi- the data, software and documentation set out in all British Standards and other BSI publications are the property of and copyrighted by BSI, or some person or entity that own copyright in the information used (such as the
47、international standardisation bodies) has formally licensed such information to BSI for commerical publication and use. Except as permitted under the Copyright, Designs and Patents Act 1988 no extract may be reproduced, stored in a retrieval system or transmitted in any form or by any means electron
48、ic, photocopying, recording or otherwise without prior written permission from BSI. This does not preclude the free use, in the course of implementing the standard, of necessary details such as symbols, and size, type or grade designations. If these details are to be used for any other purpose than implementation then the prior written permission of BSI must be obtained. Details and advice can be obtained from the Copyright & Licensing Department.Tel: +44 (0)20 8996 7070Email:
copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1