1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI British StandardsWB9423_BSI_StandardColCov_noK_AW:BSI FRONT COVERS 5/9/08 12:55 Page 1Digital addressable lighting interface Part 208: Particular requirements for control gear Switching function (dev
2、ice type 7)BS EN 62386-208:2009National forewordThis British Standard is the UK implementation of EN 62386-208:2009. It isidentical to IEC 62386-208:2009.The UK participation in its preparation was entrusted by Technical CommitteeCPL/34, Lamps and related equipment, to Subcommittee CPL/34/3, Auxilia
3、riesfor lamps.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisions of acontract. Users are responsible for its correct application. BSI 2009ISBN 978 0 580 60938 1ICS 29.130.99; 29.14
4、0.50; 29.140.99Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of the StandardsPolicy and Strategy Committee on 31 October 2009Amendments issued since publicationAmd. No. Date Text affectedBRITISH STANDARDBS EN 6
5、2386-208:2009EUROPEAN STANDARD EN 62386-208 NORME EUROPENNE EUROPISCHE NORM August 2009 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: Avenue Marnix 17, B - 1000 Bru
6、ssels 2009 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 62386-208:2009 E ICS 29.140.50; 29.140.99 English version Digital addressable lighting interface - Part 208: Particular requirements for control gear - Switching function
7、(device type 7) (IEC 62386-208:2009) Interface dclairage adressable numrique - Partie 208: Exigences particulires pour les appareillages de commande - Fonction de commutation (dispositifs de type 7) (CEI 62386-208:2009) Digital adressierbare Schnittstelle fr die Beleuchtung - Teil 208: Besondere Anf
8、orderungen an Betriebsgerte - Schaltfunktion (Gertetyp 7) (IEC 62386-208:2009) This European Standard was approved by CENELEC on 2009-07-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a
9、national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A versi
10、on in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, th
11、e Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. BS EN 62386-208:2009EN 62386-208:20
12、09 - 2 - Foreword The text of document 34C/821/CDV, future edition 1 of IEC 62386-208, prepared by SC 34C, Auxiliaries for lamps, of IEC TC 34, Lamps and related equipment, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 62386-208 on 2009-07-01. This Part 208 is inte
13、nded to be used in conjunction with EN 62386-101 and EN 62386-102, which contain general requirements for the relevant product type (control gear or control devices). The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical na
14、tional standard or by endorsement (dop) 2010-04-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2012-07-01 Annex ZA has been added by CENELEC. _ Endorsement notice The text of the International Standard IEC 62386-208:2009 was approved by CENELEC as a
15、 European Standard without any modification. In the official version, for Bibliography, the following notes have to be added for the standards indicated: IEC 60598-1 NOTE Harmonized as EN 60598-1:2008 (modified). IEC 60669-2-1 NOTE Harmonized as EN 60669-2-1:2004 (modified). IEC 60921 NOTE Harmonize
16、d as EN 60921:2004 (not modified). IEC 60923 NOTE Harmonized as EN 60923:2005 (not modified). IEC 60925 NOTE Harmonized as EN 60925:1991 (not modified). IEC 60929 NOTE Harmonized as EN 60929:2006 (not modified). IEC 61347-1 NOTE Harmonized as EN 61347-1:2008 (modified). IEC 61347-2-3 NOTE Harmonized
17、 as EN 61347-2-3:2001 (not modified). IEC 61547 NOTE Harmonized as EN 61547:2009 (not modified). CISPR 15 NOTE Harmonized as EN 55015:2006 (not modified). _ BS EN 62386-208:2009- 3 - EN 62386-208:2009 Annex ZA (normative) Normative references to international publications with their corresponding Eu
18、ropean publications The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE When an international pu
19、blication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. Publication Year Title EN/HD Year IEC 62386-101 2009 Digital addressable lighting interface - Part 101: General requirements - System EN 62386-101 2009 IEC 62386-102 2009 Digital addressable lighting
20、 interface - Part 102: General requirements - Control gearEN 62386-102 2009 BS EN 62386-208:2009 2 62386-208 IEC:2009 CONTENTS FOREWORD.5 INTRODUCTION.7 1 Scope.8 2 Normative references .8 3 Terms and definitions .8 4 General description 8 5 Electrical specification9 6 Interface power supply .9 7 Tr
21、ansmission protocol structure9 8 Timing 9 9 Method of operation .9 10 Declaration of variables11 11 Definition of commands 12 12 Test procedures .18 Annex A (informative) Examples of algorithms .70 Bibliography71 Figure 1 Example of a possible configuration .11 Figure 2 Application extended configur
22、ation command sequence example.13 Figure 3 Test sequence QUERY FEATURES .19 Figure 4 Test sequence Reset State / Persistent Memory 20 Figure 5 Test sequence QUERY LOAD ERROR.22 Figure 6 Test sequence QUERY LOAD ERROR with HOLD-OFF TIME 23 Figure 7 Test sequence QUERY LOAD ERROR with indefinitely HOL
23、D-OFF TIME 24 Figure 8 Test sequence QUERY Control Gear Information .25 Figure 9 Test sequence REFERENCE SYSTEM POWER.26 Figure 10 Test sequence REFERENCE SYSTEM POWER: 100 ms-timeout.27 Figure 11 Test sequence REFERENCE SYSTEM POWER: Command in-between .28 Figure 12 Test sequence REFERENCE SYSTEM P
24、OWER: 15 min timer29 Figure 13 Test sequence REFERENCE SYSTEM POWER: failed 30 Figure 14 Test sequence THRESHOLDS: Configuration Sequence 31 Figure 15 Test sequence ERROR HOLD-OFF TIME: Configuration Sequence .33 Figure 16 Test sequence STORE DTR AS THRESHOLD X 34 Figure 17 Test sequence STORE DTR A
25、S MIN / MAX LEVEL35 Figure 18 Test sequence STORE DTR AS ERROR HOLD-OFF TIME 36 Figure 19 Test sequence ENABLE DEVICE TYPE: Appl. extended query commands.37 Figure 20 Test sequence ENABLE DEVICE TYPE: Reference System Power 38 Figure 21 Test sequence ENABLE DEVICE TYPE: Other Application Extended Co
26、nfiguration Commands39 Figure 22 Test sequence ENABLE DEVICE TYPE: Error Hold-Off Time .41 Figure 23 Test sequence ENABLE DEVICE TYPE: Application Extended Configuration Commands 2.42 BS EN 62386-208:200962386-208 IEC:2009 3 Figure 24 Test sequence DEFAULT ON AND OFF.44 Figure 25 Test sequence DEFAU
27、LT OFF WITH FADING .45 Figure 26 Test sequence SWITCHING ON AND OFF FULL RANGE47 Figure 27 Test sequence SWITCHING ON AND OFF LIMITED RANGE 51 Figure 28 Test sequence VIRTUAL DIMMING FADE TIME54 Figure 29 Test sequence VIRTUAL DIMMING FADE RATE.56 Figure 30 Test sequence SWITCHING ON AND OFF IAPC.57
28、 Figure 31 Test sequence SWITCHING ON AND OFF ADJUSTING THRESHOLDS .58 Figure 32 Test sequence SWITCHING ON AND OFF ADJUSTING MIN/MAX 60 Figure 33 Test sequence SWITCHING ON AND OFF DEFAULT POL/SYS62 Figure 34 Test sequence SWITCHING ON AND OFF POWER ON 64 Figure 35 Test sequence SWITCHING ON AND OF
29、F SYSTEM FAILURE66 Figure 36 Test sequence QUERY EXTENDED VERSION NUMBER.68 Figure 37 Test sequence RESERVED APPLICATION EXTENDED COMMANDS69 Figure A.1 Examples of switching characteristics .70 Table 1 virtual arc power level (VAPL) .11 Table 2 Declaration of variables.12 Table 3 Summary of the appl
30、ication extended command set 18 Table 4 Parameters for the test sequence State / Persistent Memory.21 Table 5 Test step QUERY LOAD ERROR with HOLD-OFF TIME23 Table 6 Test steps REFERENCE SYSTEM POWER: Command in-between.28 Table 7 Test parameter and test steps 1 THRESHOLDS: Configuration Sequence.31
31、 Table 8 Test parameter and test steps 2 THRESHOLDS: Configuration Sequence.32 Table 9 Test parameter and test steps 3 THRESHOLDS: Configuration Sequence.32 Table 10 Test steps ERROR HOLD-OFF TIME: Configuration Sequence .33 Table 11 Test steps STORE DTR AS THRESHOLD X34 Table 12 Test steps STORE DT
32、R AS MIN / MAX LEVEL35 Table 13 Test steps STORE DTR AS ERROR HOLD-OFF TIME 36 Table 14 Test steps ENABLE DEVICE TYPE: Appl. extended query commands.37 Table 15 Test steps ENABLE DEVICE TYPE: Reference System Power 38 Table 16 Test steps 1 ENABLE DEVICE TYPE: Other Application Extended Configuration
33、 Commands40 Table 17 Test steps 2 ENABLE DEVICE TYPE: Other Application Extended Configuration Commands40 Table 18 Test steps 3 ENABLE DEVICE TYPE: Other Application Extended Configuration Commands40 Table 19 Test steps ENABLE DEVICE TYPE: Error Hold-Off Time.41 Table 20 Test steps 1 ENABLE DEVICE T
34、YPE: Application Extended Configuration Commands 2 43 Table 21 Test steps 2 ENABLE DEVICE TYPE: Application Extended Configuration Commands 2 43 Table 22 Test steps DEFAULT ON AND OFF.44 Table 23 Test steps 1 DEFAULT OFF WITH FADING 45 BS EN 62386-208:2009 4 62386-208 IEC:2009 Table 24 Test steps 2
35、DEFAULT OFF WITH FADING 46 Table 25 Test steps and parameter 1 SWITCHING ON AND OFF FULL RANGE.48 Table 26 Test steps and parameter 2 SWITCHING ON AND OFF FULL RANGE.48 Table 27 Test steps and parameter 3 SWITCHING ON AND OFF FULL RANGE.48 Table 28 Test steps and parameter 4 SWITCHING ON AND OFF FUL
36、L RANGE.49 Table 29 Test steps and parameter 5 SWITCHING ON AND OFF FULL RANGE.50 Table 30 Test steps and parameter 1 SWITCHING ON AND OFF LIMITED RANGE52 Table 31 Test steps and parameter 2 SWITCHING ON AND OFF LIMITED RANGE52 Table 32 Test steps and parameter 3 SWITCHING ON AND OFF LIMITED RANGE52
37、 Table 33 Test steps and parameter 4 SWITCHING ON AND OFF LIMITED RANGE53 Table 34 Test steps and parameter 5 SWITCHING ON AND OFF LIMITED RANGE53 Table 35 Test steps and parameter 1 VIRTUAL DIMMING FADE TIME .54 Table 36 Test steps and parameter 2 VIRTUAL DIMMING FADE TIME .55 Table 37 Test steps a
38、nd parameter 3 VIRTUAL DIMMING FADE TIME .55 Table 38 Test steps VIRTUAL DIMMING FADE RATE.56 Table 39 Test steps SWITCHING ON AND OFF IAPC.57 Table 40 Test steps and parameter 1 SWITCHING ON AND OFF ADJUSTING THRESHOLDS59 Table 41 Test steps and parameter 2 SWITCHING ON AND OFF ADJUSTING THRESHOLDS
39、59 Table 42 Test steps and parameter 3 SWITCHING ON AND OFF ADJUSTING THRESHOLDS59 Table 43 Test steps and parameter 1 SWITCHING ON AND OFF ADJUSTING MIN/MAX 60 Table 44 Test steps and parameter 2 SWITCHING ON AND OFF ADJUSTING MIN/MAX 61 Table 45 Test steps and parameter 3 SWITCHING ON AND OFF ADJU
40、STING MIN/MAX 61 Table 46 Test steps and parameter 1 SWITCHING ON AND OFF DEFAULT POL/SYS 62 Table 47 Test steps and parameter 2 SWITCHING ON AND OFF DEFAULT POL/SYS 63 Table 48 Test steps and parameter 1 SWITCHING ON AND OFF POWER ON .64 Table 49 Test steps and parameter 2 SWITCHING ON AND OFF POWE
41、R ON .65 Table 50 Test steps and parameter 1 SWITCHING ON AND OFF SYSTEM FAILURE 66 Table 51 Test steps and parameter 2 SWITCHING ON AND OFF SYSTEM FAILURE 67 Table 52 Test steps RESERVED APPLICATION EXTENDED COMMANDS .69 BS EN 62386-208:200962386-208 IEC:2009 5 INTERNATIONAL ELECTROTECHNICAL COMMIS
42、SION _ DIGITAL ADDRESSABLE LIGHTING INTERFACE Part 208: Particular requirements for control gear Switching function (device type 7) FOREWORD 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising all national electrotechnical committees (IEC
43、 National Committees). The object of the IEC is to promote international co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Repor
44、ts, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)“). Their preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with may participate in this preparatory work. International, governmental and no
45、n-governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for Standardization (ISO) in accordance with conditions determined by agreement between the two organizations. 2) The formal decisions or agreements o
46、f IEC on technical matters express, as nearly as possible, an international consensus of opinion on the relevant subjects since each technical committee has representation from all interested IEC National Committees. 3) IEC Publications have the form of recommendations for international use and are
47、accepted by IEC National Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any misinterpretation by any end user. 4) In order to promote intern
48、ational uniformity, IEC National Committees undertake to apply IEC Publications transparently to the maximum extent possible in their national and regional publications. Any divergence between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter. 5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any equipment declared to be in conformity with an IEC Publication. 6) All users should ensure that they have the latest edition
copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1