1、BSI Standards PublicationDouble-capped LED lampsdesigned to retrofit linear fluorescent lamps Safety specificationsBS EN 62776:2015BS EN 62776:2015 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 62776:2015. It is identical to IEC 62776:2014 incorporating corrig
2、endum March 2015.The start and finish of text introduced or altered by corrigendum is indicated in the text by tags. Text altered by IEC corrigendum March 2015 is indicated in the text by .The UK participation in its preparation was entrusted by Technical Committee CPL/34, Lamps and Related Equipmen
3、t, to Subcommittee CPL/34/1, Electric lamps.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. The British Standa
4、rds Institution 2015 Published by BSI Standards Limited 2015ISBN 978 0 580 81889 9ICS 29.140.99Compliance with a British Standard cannot confer immunity from legal obligations.This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 May 2015.Amendm
5、ents/corrigenda issued since publicationDate Text affectedEUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 62776 April 2015 ICS 29.140.99 English Version Double-capped LED lamps designed to retrofit linear fluorescent lamps - Safety specifications (IEC 62776:2014 + COR1:2015) Lampes LED deux cul
6、ots conues pour remplacer des lampes fluorescence linaires - Spcifications de scurit (IEC 62776:2014 + COR1:2015) Zweiseitig gesockelte LED-Lampen als Ersatz (Retrofit) fr zweiseitig gesockelte Leuchtstofflampen - Sicherheitsanforderungen (IEC 62776:2014 + COR1:2015) This European Standard was appro
7、ved by CENELEC on 2015-01-15. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such natio
8、nal standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its ow
9、n language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia
10、, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. European Committee for Electrotechnical Standardization Comit Europen
11、de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2015 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members. Ref. No. EN 62776:2015 E BS EN 62776:2015EN
12、 62776:2015 - 2 - Foreword The text of document 34A/1795/FDIS, future edition 1 of IEC 62776 + corrigendum March 2015, prepared by SC 34A “Lamps“ of IEC/TC 34 “Lamps and related equipment“ was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as EN 62776:2015. The following dates ar
13、e fixed: latest date by which the document has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2015-10-15 latest date by which the national standards conflicting with the document have to be withdrawn (dow) 2018-01-15 Attention is drawn to
14、 the possibility that some of the elements of this document may be the subject of patent rights. CENELEC and/or CEN shall not be held responsible for identifying any or all such patent rights. This standard covers the Principle Elements of the Safety Objectives for Electrical Equipment Designed for
15、Use within Certain Voltage Limits (LVD - 2006/95/EC). Endorsement notice The text of the International Standard IEC 62776:2014 + corrigendum March 2015 was approved by CENELEC as a European Standard without any modification. In the official version, for Bibliography, the following notes have to be a
16、dded for the standards indicated: IEC 60529:1989 NOTE Harmonized as EN 60529:1991 (not modified). IEC 60529:1989/A1:1999 NOTE Harmonized as EN 60529:1991/A1:2000 (not modified). IEC 60529:1989/A2:2013 NOTE Harmonized as EN 60529:1991/A2:2013 (not modified). IEC 62471 NOTE Harmonized as EN 62471. BS
17、EN 62776:2015EN 62776:2015 - 2 - Foreword The text of document 34A/1795/FDIS, future edition 1 of IEC 62776 + corrigendum March 2015, prepared by SC 34A “Lamps“ of IEC/TC 34 “Lamps and related equipment“ was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as EN 62776:2015. The fol
18、lowing dates are fixed: latest date by which the document has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2015-10-15 latest date by which the national standards conflicting with the document have to be withdrawn (dow) 2018-01-15 Attent
19、ion is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC and/or CEN shall not be held responsible for identifying any or all such patent rights. This standard covers the Principle Elements of the Safety Objectives for Electrical Equipmen
20、t Designed for Use within Certain Voltage Limits (LVD - 2006/95/EC). Endorsement notice The text of the International Standard IEC 62776:2014 + corrigendum March 2015 was approved by CENELEC as a European Standard without any modification. In the official version, for Bibliography, the following not
21、es have to be added for the standards indicated: IEC 60529:1989 NOTE Harmonized as EN 60529:1991 (not modified). IEC 60529:1989/A1:1999 NOTE Harmonized as EN 60529:1991/A1:2000 (not modified). IEC 60529:1989/A2:2013 NOTE Harmonized as EN 60529:1991/A2:2013 (not modified). IEC 62471 NOTE Harmonized a
22、s EN 62471. BS EN 62776:2015- 3 - EN 62776:2015 Annex ZA (normative) Normative references to international publications with their corresponding European publications The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application.
23、For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE 1 When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. NOTE 2 U
24、p-to-date information on the latest versions of the European Standards listed in this annex is available here: www.cenelec.eu Publication Year Title EN/HD Year IEC 60061-1 - Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 1: Lamp caps EN 60061-1 - I
25、EC 60061-3 - Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 3: Gauges EN 60061-3- IEC 60061-4 - Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 4: Guidelines and general information EN 60061-4 - IE
26、C 60081 - Double-capped fluorescent lamps - Performance specifications EN 60081 - IEC 60155 - Glow-starters for fluorescent lamps EN 60155 - IEC 60360 - Standard method of measurement of lamp cap temperature rise EN 60360 - IEC 60417-DB - Graphical symbols for use on equipment - - IEC 60598-1 - Lumi
27、naires - Part 1: General requirements and tests EN 60598-1 - IEC 60695-2-10 2013 Fire hazard testing - Part 2-10: Glowing/hot-wire based test methods - Glow-wire apparatus and common test procedure EN 60695-2-10 2013 IEC 60695-2-11 + corr. January 2000 2001 Fire hazard testing - Part 2-11: Glowing/h
28、ot-wire based test methods - Glow-wire flammability test method for end-products EN 60695-2-11 2001 1) 1)Superseded by EN 60695-2-11:2014 (IEC 60695-2-11:2014): DOW = 2017-03-13. BS EN 62776:2015EN 62776:2015 - 4 - Publication Year Title EN/HD Year IEC 60921 - Ballasts for tubular fluorescent lamps
29、- Performance requirements EN 60921 - IEC 61195 - Double-capped fluorescent lamps - Safety specifications EN 61195 - IEC 61347-1 2015 Lamp controlgear - Part 1: General and safety requirements EN 61347-1 201X 2)IEC 61347-2-8 - Lamp controlgear - Part 2-8: Particular requirements for ballasts for flu
30、orescent lamps EN 61347-2-8 - IEC 62031 - LED modules for general lighting - Safety specifications EN 62031 - IEC 62504 - General lighting - Light emitting diode (LED) products and related equipment - Terms and definitions EN 62504 - IEC/TR 62778 - Application of IEC 62471 for the assessment of blue
31、 light hazard to light sources and luminaires - - ISO 4046-4 2002 3)Paper, board, pulps and related terms - Vocabulary - Part 4: Paper and board grades and converted products - - 2)To be published. 3)Withdrawn publication. BS EN 62776:2015EN 62776:2015 - 4 - Publication Year Title EN/HD Year IEC 609
32、21 - Ballasts for tubular fluorescent lamps - Performance requirements EN 60921 - IEC 61195 - Double-capped fluorescent lamps - Safety specifications EN 61195 - IEC 61347-1 2015 Lamp controlgear - Part 1: General and safety requirements EN 61347-1 201X 2)IEC 61347-2-8 - Lamp controlgear - Part 2-8:
33、Particular requirements for ballasts for fluorescent lamps EN 61347-2-8 - IEC 62031 - LED modules for general lighting - Safety specifications EN 62031 - IEC 62504 - General lighting - Light emitting diode (LED) products and related equipment - Terms and definitions EN 62504 - IEC/TR 62778 - Applica
34、tion of IEC 62471 for the assessment of blue light hazard to light sources and luminaires - - ISO 4046-4 2002 3)Paper, board, pulps and related terms - Vocabulary - Part 4: Paper and board grades and converted products - - 2)To be published. 3)Withdrawn publication. BS EN 62776:2015 2 IEC 62776:2014
35、 IEC 2014 CONTENTS INTRODUCTION . 6 1 Scope 7 2 Normative references 7 3 Terms and definitions 8 4 General requirements and general test requirements . 9 5 Marking . 10 5.1 Marking on the lamp . 10 5.2 Marking on the lamp, on the immediate lamp wrapping (or container) or in the instructions . 12 5.3
36、 Instruction manual 12 General . 12 5.3.1Declaration of the product 12 5.3.2Graphical instruction 13 5.3.3Mounting . 13 5.3.45.4 Compliance . 13 6 Interchangeability 14 6.1 Interchangeability of the cap . 14 6.2 Mass . 14 6.3 Dimensions . 14 Requirements 14 6.3.1Dimensions at 25 C (non-operating) .
37、14 6.3.2Variation of dimension A due to self-heating at 25 C 15 6.3.3Dimension B at minimum ambient temperature 15 6.3.4Dimension A at maximum ambient temperature . 15 6.3.5Compliance . 15 6.3.66.4 Temperature . 15 Temperature requirement 15 6.4.1Power requirement 16 6.4.2Compliance . 16 6.4.36.5 Sa
38、fety of the lamp in case a wrong starter-lamp combination is used 16 7 Pin-safety during insertion . 16 8 Protection against accidental contact with live parts 17 8.1 General . 17 8.2 Test to establish whether a conductive part may cause an electric shock during operation 17 8.3 Insulation resistanc
39、e . 19 8.4 Electric strength 19 9 Mechanical requirements for caps . 19 9.1 Construction and assembly . 19 9.2 Torque test on unused lamps 19 9.3 Torque test after heat treatment 20 9.4 Repetition of 8.2 . 20 10 Cap temperature rise . 20 11 Resistance to heat . 21 BS EN 62776:2015IEC 62776:2014 IEC
40、2014 3 12 Resistance to flame and ignition 22 13 Fault conditions . 22 13.1 General . 22 13.2 Testing under extreme electrical conditions 22 13.3 Short-circuit across capacitors 23 13.4 Fault conditions across electronic components . 23 13.5 Compliance . 23 13.6 Further requirements 24 13.7 Safety o
41、f the lamp with different types of controlgear 24 13.8 Compliance for test with different types of controlgear 25 13.9 Safety of the lamp in case the luminaire controlgear short circuits 25 14 Creepage distances and clearances 25 15 Lamp with protection against dust and moisture 25 15.1 Aim of the t
42、est 25 15.2 Thermal endurance . 26 15.3 IP testing 26 16 Photobiological hazard 26 16.1 UV radiation 26 16.2 Blue light hazard . 26 16.3 Infrared radiation 26 (informative) Conformity testing during manufacture 27 Annex AA.1 Background and recommended procedure 27 A.2 Testing . 27 Bibliography 28 Fi
43、gure 1 Lamp suitable for high frequency operation 10 Figure 2 Lamp suitable for 50 Hz or 60 Hz operation 11 Figure 3 Lamp not suitable for emergency operation 11 Figure 4 LED replacement starter 11 Figure 5 Lamp to be used in dry conditions or in a luminaire that provides protection . 12 Figure 6 Di
44、mming not allowed 12 Figure 7 Schematic steps of removing a fluorescent lamp and inserting a double-capped LED lamp designed to retrofit linear fluorescent lamp . 13 Figure 8 Test configuration for touch current measurement 17 Figure 9 Standard test finger (according to IEC 60529) 18 Figure 10 Ball-
45、pressure test apparatus. 21 Table 1 Interchangeability gauges and lamp cap dimensions . 14 Table 2 Torque values for unused lamps 20 Table 3 Torque values after heating treatment . 20 Table 4 Minimum LED lamp impedances 24 Table A.1 Minimum values for electrical tests. 27 BS EN 62776:2015IEC 62776:2
46、014 IEC 2014 3 12 Resistance to flame and ignition 22 13 Fault conditions . 22 13.1 General . 22 13.2 Testing under extreme electrical conditions 22 13.3 Short-circuit across capacitors 23 13.4 Fault conditions across electronic components . 23 13.5 Compliance . 23 13.6 Further requirements 24 13.7
47、Safety of the lamp with different types of controlgear 24 13.8 Compliance for test with different types of controlgear 25 13.9 Safety of the lamp in case the luminaire controlgear short circuits 25 14 Creepage distances and clearances 25 15 Lamp with protection against dust and moisture 25 15.1 Aim
48、of the test 25 15.2 Thermal endurance . 26 15.3 IP testing 26 16 Photobiological hazard 26 16.1 UV radiation 26 16.2 Blue light hazard . 26 16.3 Infrared radiation 26 (informative) Conformity testing during manufacture 27 Annex AA.1 Background and recommended procedure 27 A.2 Testing . 27 Bibliograp
49、hy 28 Figure 1 Lamp suitable for high frequency operation 10 Figure 2 Lamp suitable for 50 Hz or 60 Hz operation 11 Figure 3 Lamp not suitable for emergency operation 11 Figure 4 LED replacement starter 11 Figure 5 Lamp to be used in dry conditions or in a luminaire that provides protection . 12 Figure 6 Dimming not allowed 12 Figure 7 Schematic steps of removing a fluorescent lamp and inserting a double-capped LED lamp designed to retrofit linear fluorescent lamp . 13