1、ETSI EN 300 396-8-2 VI .I .I (2001-01) European Standard (Telecommunications series) Terrestrial Trunked Radio (TETRA); Technical requirements for Direct Mode Operation (DMO); Part 8: Protocol Implementation Conformance Statement (PICS) proforma specification; Sub-part 2: Type 1 repeater Air Interfa
2、ce (AI) 2 ETSI EN 300 396-8-2 V1.l.l (2001-01) Th Reference DENnETRA-02007-8-2 Keywords ICs, PICS, TETRA, DMO, radio ETSI 650 Route des Lucioles F-O6921 Sophia Antipolis Cedex - FRANCE Tel.: +33 4 92 94 42 O0 Fax: +33 4 93 65 47 16 Siret No 348 623 562 00017 - NAF 742 C Association but non lucratif
3、enregistre la Sous-prfecture de Grasse (06) No 7803/88 Important notice Individual copies of the present document can be downloaded from: htti3:lwww. etsi I oq present document may be made available in more than one electronic version or in print. I any cas Df existing perceived difference in conten
4、ts between such versions, the reference version is the Portable Document Format (PDF). In case of dispute, the reference shall be the printing on ETSI printers of the PDF version kept on a specific network drive within ETSI Secretariat. Users of the present document should be aware that the document
5、 may be subject to revision or change of status. Information on the current status of this and other ETSI documents is available at If you find errors in the present document, send your comment to: editor etsi.fr Copyright Notification No part may be reproduced except as authorized by written permis
6、sion. The copyright and the foregoing restriction extend to reproduction in all media. 8 European Telecommunications Standards Institute 2001. All rights reserved. ETSI 3 ETSI EN 300 396-8-2 V1.l.l (2001-01) Contents Intellectual Property Rights 5 Foreword 5 Introduction 6 1 Scope 7 2 References 7 3
7、 Definitions and abbreviations 8 3.1 Definitions 8 3.2 Abbreviations 8 4 Conformance to this PICS proforma specification . 8 Protocol ICs proforma (PICS) for EN 300 396-4 . 9 Guidance for completing the PICS proforma . 9 Instructions for completing the PICS proforma 11 Annex A (normative): A . 1 A.l
8、.l A.1.2 A.1.3 A.2 Identification of the implementation 11 A.2.1 Date of the statement . 11 A.2.2 Implementation Under Test (IUT) identification 11 A.2.3 System Under Test (SUT) identification 11 A.2.4 Product supplier 12 A.2.5 Client (if different from product supplier) 12 A.2.6 PICS contact person
9、 12 A.3 Identification of the Protocol . 13 A.4 Global statement of conformance 13 AS Roles 13 A.6 Protocols for DM-MS supporting operation with a type 1 DM-REP (MS-REP1) . 13 A.6.1 MS-REP1 Direct Mode Call Control (DMCC) at Layer 3 . 13 A.6.1.1 DMCC major capabilities . 14 A.6.1.2 Circuit mode call
10、 14 A.6.1.3 Circuit mode call Set-up . 15 A.6.1.4 Circuit mode services offered . 15 A.6.1.5 Short data services . 16 A.6.1.6 Type of short data service . 16 A.6.1.7 Data transmission . 17 A.6.1.8 SDS user defined data 18 A.6.1.9 DMCC PDUs . 18 A.6.1.10 DMCC constants 20 A.6.1.11 DMCC timers 20 A.6.
11、2 A.6.2.1 MS-REP1 MAC features 21 A.6.2.3 MS-REP1 MAC PDUs . 26 A.6.2.4 A.6.2.5 MS-REP1 MAC constants 27 A.6.2.6 MS-REP1 MAC timers 29 A.7 Type 1 DM-REP Protocol . 30 A.7.1 DM-REP1 Data link layer (DLL) at Layer 2 30 A.7.1.1 Major services 30 A.7.1.2 DM-REP1 MAC features . 30 Purposes and structure
12、. 9 Abbreviations and conventions 9 MS-REP1 Data link layer (DLL) at Layer 2 . 21 A.6.2.2 MS-REP1-MAC procedures . 22 MS-REP1 MAC generated messages 27 ETSI 4 ETSI EN 300 396-8-2 V1.l.l (2001-01) A.7.1.3 DM-REP1 MAC procedures . 31 A.7.1.5 DM-REP1 MAC generated messages . 33 A.7.1.6 DM-REP1 MAC cons
13、tants . 33 A.7.1.7 DM-REP1 MAC timers 34 A.8. PDU parameters for MS-REP1 and DM-REP1 used in DMCC at layer 3 and DLL at layer 2 35 A.7.1.4 DM-REP1 MAC PDUS 33 A.8.1 A.8.1.1 A.8.1.2 A.8.1.3 A.8.1.4 A.8.1.5 A.8.1.6 A.8.1.7 A.8.1.8 A.8.1.9 A.8.1.10 A.8.1.11 A.8.1.12 A.8.1.13 A.8.1.14 A.8.1.15 A.8.1.16
14、A.8.1.17 A.8.2 A.8.2.1 A.8.2.2 A.8.2.3 A.8.2.4 A.8.2.5 A.8.2.6 A.8.3 A.8.3.1 A.8.3.2 A.8.3.3 A.8.3.4 MS-REP1 PDU parameters for DMCC at layer 3 . 35 DM-SETUP . 35 DM-SETUP PRES . 36 DM-CONNECT . 36 DM-DISCONNECT . 36 DM-CONNECT ACK 37 DM-OCCUPIED 37 DM-RELEASE 37 DM-TX CEASED 38 DM-TX REQUEST 38 DM-
15、TX ACCEPT 38 DM-PREEMPT . 38 DM-PRE ACCEPT 39 DM-REJECT . 39 DM-INFO 39 DM-SDS UDATA . 40 DM-SDS DATA 40 DM-SDS ACK . 41 MS-REP1 and DM-REP1 PDU parameters for DLL at layer 2 . 41 DMAC-SYNC in SCWS 41 DPRES-SYNC PDU 42 DMAC-DATA . 43 DMAC-FRAG . 43 DMAC-END 43 DMAC-U SIGNAL 44 DM-MAC generated messa
16、ge parameters 44 DM-RESERVED . 44 DM-SDS OCCUPIED 44 DM-TIMING REQUEST . 44 DM-TIMING ACK 44 History . 45 ETSI 5 ETSI EN 300 396-8-2 V1.l.l (2001-01) Intellectual Property Rights IPRs essential or potentially essential to the present document may have been declared to ETSI. The information pertainin
17、g to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be found in ETSI SR O00 314: “Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in respect of ETSI standards“, which is available from the ETSI Secretariat
18、. Latest updates are available on the ETSI Web server ClattD:/www.etsP.c/iDr. Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee can be given as to the existence of other IPRs not referenced in ETSI SR O00 314 (or the updates on the
19、ETSI Web server) which are, or may be, or may become, essential to the present document. Foreword This European Standard (Telecommunications series) has been produced by ETSI Project Terrestrial Trunked Radio (TETRA). The present document had been submitted to Public Enquiry as ETS 300 396-8-2. Duri
20、ng the processing for Vote it was converted into an EN. The present document is part 8 of a multi-part deliverable covering the Terrestrial Trunked Radio (TETRA); Technical requirements for Direct Mode Operation (DMO); as identified below: Part 1: “General network design“; Part 2: “Radio aspects“; P
21、art 3: “Mobile Station to Mobile Station (MS-MS) Air Interface (AI) protocol“; Part 4: “Type 1 repeater air interface“; Part 5: “Gateway air interface“; Part 6: “Security“; Part 7: “Type 2 repeater air interface“; Part 8: “Protocol Implementation Conformance Statement (PICS) proforma specification“;
22、 Part 9: “Service and Description Language (SDL) model“; Part 10: “Managed Direct Mode Operation (DMO)“. National transposition dates Date of adoption of this EN Date of latest announcement of this EN (doa): Date of latest publication of new National Standard or endorsement of this EN (dop/e): Date
23、of withdrawal of any conflicting National Standard (dow): 22 December 2000 31 March 2001 30 September 2001 30 September 2001 ETSI 6 ETSI EN 300 396-8-2 V1.l.l (2001-01) Introduction To evaluate conformance of a particular implementation, it is necessary to have a statement of which capabilities and
24、options have been implemented for a telecommunication specification. Such a statement is called an Implementation Conformance Statement (ICs). ETSI 7 ETSI EN 300 396-8-2 V1.l.l (2001-01) 1 Scope The present document provides the Protocol Implementation Conformance Statement (PICS) proforma for TETRA
25、 Direct Mode Operation (DMO) Mobile Stations (MS) connected to type 1 repeater (MS-REP1) and for TETRA Direct Mode Operation type 1 repeaters (DM-REP1) Air Interface (AI) protocol, defined in EN 300 396-4 i in compliance with the relevant requirements, and in accordance with the relevant guidance gi
26、ven in ISO/IEC 9646-7 5 and ETS 300 406 3. 2 References The following documents contain provisions which, through reference in this text, constitute provisions of the present documen t. References are either specific (identified by date of publication, edition number, version number, etc.) or non-sp
27、ecific. For a specific reference, subsequent revisions do not apply. For a non-specific reference, the latest version applies. u1 ETSI EN 300 396-4: “Terrestrial Trunked Radio (TETRA); Technical requirements for Direct Mode Operation (DMO); Part 4: Type 1 repeater air interface“. ETSI ETS 300 396-8-
28、1: “Terrestrial Trunked Radio (TETRA); Technical requirements for Direct Mode Operation (DMO); Part 8: Protocol Implementation Conformance Statement (PICS) proforma specification; Sub-part 1: Mobile Station to Mobile Station (MS-MS) Air Interface (AI)“. ETSI ETS 300 406: “Methods for Testing and Spe
29、cification (MTS); Protocol and profile conformance testing specifications Standardization Methodology“. ISO/IEC 9646-1 (1994): “Information technology - Open systems interconnection - Conformance testing methodology and framework - Part 1: General concepts“. ISO/IEC 9646-7 (1995): “Information techn
30、ology - Open systems interconnection - Conformance testing methodology and framework - Part 7: Implementation Conformance Statements“. ETSI ETS 300 396-3 (1998): “Terrestrial Trunked Radio (TETRA); Technical requirements for Direct Mode Operation (DMO); Part 3: Mobile Station to Mobile Station (MS-M
31、S) Air Interface (AI) protocol“. 121 131 141 151 161 ETSI 8 ETSI EN 300 396-8-2 V1.l.l (2001-01) 3 3.1 Definitions and abbreviations Def i n it ions For the purposes of the present document, the terms and definitions given in EN 300 396-4 i, ISO/IEC 9646-1 4, ISO/IEC 9646-7 5 and the following apply
32、. Implementation Conformance Statement (ICs): statement made by the supplier of an implementation or system claimed to conform to a given specification, stating which capabilities have been implemented. The ICs can take several forms: protocol ICs, profile ICs, profile specific ICs, information obje
33、ct ICs, etc. ICs proforma: document, in the form of a questionnaire, which when completed for an implementation or system becomes an ICs Protocol ICs (PICS): ICs for an implementation or system claimed to conform to a given protocol specification 3.2 Abbreviations For the purposes of the present doc
34、ument, the following abbreviations apply: ICs Implementation Conformance Statement IUT Implementation Under Test PICS Protocol Implementation Conformance Statement SCS System Conformance Statement SUT System Under Test 4 Conformance to this PICS proforma specification If it claims to conform to the
35、present document, the actual PICS proforma to be filled in by a supplier shall be technically equivalent to the text of the PICS proforma given in annex A, and shall preserve the numbering/naming and ordering of the proforma items. A PICS which conforms to the present document shall be a conforming
36、PICS proforma completed in accordance with the guidance for completion given in clause A. 1. ETSI 9 ETSI EN 300 396-8-2 V1.l.l (2001-01) Annex A (normative): Protocol ICs proforma (PICS) for EN 300 396-4 Notwithstanding the provisions of the copyright clause related to the text of the present docume
37、nt, ETSI grants that users of the present document may freely reproduce the PICS proforma in this annex so that it can be used for its intended purposes and may further publish the completed PICS. A.l Guidance for completing the PICS proforma A.1 .I Purposes and structure The purpose of this PICS pr
38、oforma is to provide a mechanism whereby a supplier of an implementation of the requirements defined in EN 300 396-4 i may provide information about the implementation in a standardized manner. The PICS proforma is subdivided into clauses for the following categories of information: - - identificati
39、on of the implementation; - global statement of conformance; - - - - DM-REP1 part (layer 2); - guidance for completing the PICS proforma; identification of the roles, MS-REP1 or DM-REP1; MS-REP1 layer 3 protocol part; MS-REP1 layer 2 protocol part; PDU parameters at layer 3 and layer 2. A. 1.2 Abbre
40、viations and conventions The PICS proforma contained in this annex is comprised of information in tabular form in accordance with the guidelines presented in ISO/IEC 9646-7 5. Item column The item column contains a number which identifies the item in the table. Item description column The item descr
41、iption column describes in free text each respective item (e.g. parameters, timers, etc.). It implicitly means “is supported by the implementation?“. Status column The following notations, defined in ISO/IEC 9646-7 5, are used for the status column: m O n/a X mandatory - the capability is required t
42、o be supported; optional - the capability may be supported or not; not applicable - in the given context, it is impossible to use the capability; prohibited (excluded) - there is a requirement not to use this capability in the given context; ETSI 10 ETSI EN 300 396-8-2 V1.l.l (2001-01) 0.i qualified
43、 optional - for mutually exclusive or selectable options from a set. “i“ is an integer which identifies a unique group of related optional items and the logic of their selection which is defined immediately following the table; conditional - the requirement on the capability (“m“, “o“, “x“ or “n/a“)
44、 depends on the support of other optional or Conditional items. “i“ is an integer identifying a unique conditional status expression which is defined immediately following the table. ci Reference column The reference column makes reference to EN 300 396-4 i, except where explicitly stated otherwise.
45、 Support column The support column shall be filled in by the supplier of the implementation. The following common notations, defined in ISOAEC 9646-7 5, are used for the support column: Y or y N or n N/A, n/a or - supported by the implementation; not supported by the implementation; no answer requir
46、ed (allowed only if the status is n/a, directly or after evaluation of a conditional status). If this PICS proforma is completed in order to describe a multiple-profile support in a system, it is necessary to be able to answer that a capability is supported for one profile and not supported for anot
47、her. In that case, the supplier shall enter the unique reference to a conditional expression, preceded by “?“ (e.g. ?3). This expression shall be given in the space for comments provided at the bottom of the table. It uses predicates defined in the SCS, each of which refers to a single profile and w
48、hich takes the value TRUE if and only if that profile is to be used. EXAMPLE: ?3: IF prof1 THEN Y ELSE N. It is also possible to provide a comment to an answer in the space provided at the bottom of the table. NOTE: As stated in ISO/IEC 9646-7 5, support for a received PDU requires the ability to pa
49、rse all valid parameters of that PDU. Supporting a PDU while having no ability to parse a valid parameter is non- conformant. Support for a parameter on a PDU means that the semantics of that parameter are supported. Values allowed column The values allowed column contains the type, the list, the range, or the length of values allowed. The following notations are used: range of values: example: 5 20 list of values: , , , example: 2,4, 6, 8, 9 example: llOlB, lOllB, 1111B example: OA“, 34H, 2F“ list of named values: (), (), , ( example: reject(l),