1、 ETSI EN 303 423 V1.2.1 (2018-08) Environmental Engineering (EE); Electrical and electronic household and office equipment; Measurement of networked standby power consumption of Interconnecting equipment; Harmonised Standard covering the measurement method for EC Regulation 1275/2008 amended by EU R
2、egulation 801/2013 HARMONISED EUROPEAN STANDARD ETSI ETSI EN 303 423 V1.2.1 (2018-08) 2 Reference REN/EE-EEPS34 Keywords customer premises networks, energy efficiency, network, power measurement ETSI 650 Route des Lucioles F-06921 Sophia Antipolis Cedex - FRANCE Tel.: +33 4 92 94 42 00 Fax: +33 4 93
3、 65 47 16 Siret N 348 623 562 00017 - NAF 742 C Association but non lucratif enregistre la Sous-Prfecture de Grasse (06) N 7803/88 Important notice The present document can be downloaded from: http:/www.etsi.org/standards-search The present document may be made available in electronic versions and/o
4、r in print. The content of any electronic and/or print versions of the present document shall not be modified without the prior written authorization of ETSI. In case of any existing or perceived difference in contents between such versions and/or in print, the only prevailing document is the print
5、of the Portable Document Format (PDF) version kept on a specific network drive within ETSI Secretariat. Users of the present document should be aware that the document may be subject to revision or change of status. Information on the current status of this and other ETSI documents is available at h
6、ttps:/portal.etsi.org/TB/ETSIDeliverableStatus.aspx If you find errors in the present document, please send your comment to one of the following services: https:/portal.etsi.org/People/CommiteeSupportStaff.aspx Copyright Notification No part may be reproduced or utilized in any form or by any means,
7、 electronic or mechanical, including photocopying and microfilm except as authorized by written permission of ETSI. The content of the PDF version shall not be modified without the written authorization of ETSI. The copyright and the foregoing restriction extend to reproduction in all media. ETSI 20
8、18. All rights reserved. DECTTM, PLUGTESTSTM, UMTSTMand the ETSI logo are trademarks of ETSI registered for the benefit of its Members. 3GPPTM and LTETMare trademarks of ETSI registered for the benefit of its Members and of the 3GPP Organizational Partners. oneM2M logo is protected for the benefit o
9、f its Members. GSMand the GSM logo are trademarks registered and owned by the GSM Association. ETSI ETSI EN 303 423 V1.2.1 (2018-08) 3 Contents Intellectual Property Rights 5g3Foreword . 5g3Modal verbs terminology 5g3Introduction 6g31 Scope 7g31.1 Equipment in the scope of the present document . 7g3
10、1.2 Equipment not in the scope of the present document . 7g32 References 7g32.1 Normative references . 7g32.2 Informative references 8g33 Definitions and abbreviations . 9g33.1 Definitions 9g33.2 Abbreviations . 10g34 Information required for testing purposes 11g34.1 Information about networked port
11、(s) 11g34.2 Power management function - periods Essential, or potentially Essential, IPRs notified to ETSI in respect of ETSI standards“, which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web server (https:/ipr.etsi.org/). Pursuant to the ETSI IPR Policy, no inve
12、stigation, including IPR searches, has been carried out by ETSI. No guarantee can be given as to the existence of other IPRs not referenced in ETSI SR 000 314 (or the updates on the ETSI Web server) which are, or may be, or may become, essential to the present document. Trademarks The present docume
13、nt may include trademarks and/or tradenames which are asserted and/or registered by their owners. ETSI claims no ownership of these except for any which are indicated as being the property of ETSI, and conveys no right to use or reproduce any trademark and/or tradename. Mention of those trademarks i
14、n the present document does not constitute an endorsement by ETSI of products, services or organizations associated with those trademarks. Foreword This Harmonised European Standard (EN) has been produced by ETSI Technical Committee Environmental Engineering (EE). The present document has been prepa
15、red under the Commissions standardisation M/544 to provide one voluntary means of conforming to the ecodesign requirements of Commission Regulation (EU) n 801/2013 i.2 of 22 August 2013 implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to ecodesign requirem
16、ents for standby, off mode electric power consumption of electrical and electronic household and office equipment (EC No 1275/2008 i.1) and ecodesign requirements for televisions (EC No 642/2009 i.10). Once the present document is cited in the Official Journal of the European Union under that Regula
17、tion, compliance with the normative clauses of the present document given in table A.1 confers, within the limits of the scope of the present document, a presumption of conformity with the corresponding ecodesign requirements of that Regulation, and associated EFTA Regulations. National transpositio
18、n dates Date of adoption of this EN: 6 August 2018 Date of latest announcement of this EN (doa): 30 November 2018 Date of latest publication of new National Standard or endorsement of this EN (dop/e): 31 May 2019 Date of withdrawal of any conflicting National Standard (dow): 31 May 2020 Modal verbs
19、terminology In the present document “shall“, “shall not“, “should“, “should not“, “may“, “need not“, “will“, “will not“, “can“ and “cannot“ are to be interpreted as described in clause 3.2 of the ETSI Drafting Rules (Verbal forms for the expression of provisions). “must“ and “must not“ are NOT allow
20、ed in ETSI deliverables except when used in direct citation. ETSI ETSI EN 303 423 V1.2.1 (2018-08) 6 Introduction The methods defined in the present document are intended to define requirements for the measurement of the power consumed by the interconnecting equipment having one or more wired or wir
21、eless networked port(s) able to resume a function by way of a remotely initiated trigger or reactivation trigger from a network connection. The present document also provides a method to test power management and whether it is possible to deactivate wireless network connection(s). For the measuremen
22、t of low power modes, reference is made to CENELEC EN 50564 1. ETSI ETSI EN 303 423 V1.2.1 (2018-08) 7 1 Scope 1.1 Equipment in the scope of the present document The present document specifies methods of measurement of electrical power consumption in networked standby and the reporting of the result
23、s for network interconnecting equipment. Example of interconnecting equipment are in Annex B. Power consumption in standby (other than networked standby) is covered by CENELEC EN 50564 1, including the input voltage range. The present document also provides a method to test power management and whet
24、her it is possible to deactivate wireless network connection(s). The present document applies to electrical products with a rated input voltage of 230 V a.c. for single phase products and 400 V a.c. for three phase products. The present document is produced under the mandate M/544 and can be used to
25、 demonstrate compliance to the EU regulation 801/2013 i.2. NOTE 1: The EU regulation 801/2013 i.2 applies to equipment designed for use with a nominal voltage rating of 250 V and below. NOTE 2: EU regulation 801/2013 i.2 does not apply to electrical and electronic household and office equipment plac
26、ed on the market with a low voltage external power supply to work as intended. NOTE 3: “Low voltage external power supply“ is the definition provided in EU regulation 278/2009 i.3. NOTE 4: The measurement of energy consumption and performance of equipment during intended use are generally specified
27、in product standards and are not covered by the present document. NOTE 5: Where the present document is referenced by more specific standards or procedures, these should define and name the relevant conditions to which this test procedure is applied. 1.2 Equipment not in the scope of the present doc
28、ument The present document does not apply to the measurement of electrical power consumption in networked standby for edge equipment. The edge equipment is a networked equipment that can be connected to a network and interact with that network or other devices and that does not have, as its primary
29、function, the passing of network traffic to provide a network. Edge equipment are covered in CENELEC EN 50643 i.8. 2 References 2.1 Normative references References are specific, identified by date of publication and/or edition number or version number. Only the cited version applies. Referenced docu
30、ments which are not found to be publicly available in the expected location might be found at https:/docbox.etsi.org/Reference/. NOTE: While any hyperlinks included in this clause were valid at the time of publication, ETSI cannot guarantee their long term validity. The following referenced document
31、s are necessary for the application of the present document. 1 CENELEC EN 50564 (2011): “Electrical and electronic household and office equipment - measurement of low power consumption“. ETSI ETSI EN 303 423 V1.2.1 (2018-08) 8 2.2 Informative references References are either specific (identified by
32、date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. NOTE: While any hyperlinks included in this clause wer
33、e valid at the time of publication, ETSI cannot guarantee their long term validity. The following referenced documents are not necessary for the application of the present document but they assist the user with regard to a particular subject area. i.1 Commission Regulation (EC) No 1275/2008 of 17 De
34、cember 2008 implementing Directive 2005/32/EC of the European Parliament and of the Council with regard to ecodesign requirements for standby and off mode electric power consumption of electrical and electronic household and office equipment. i.2 Commission Regulation (EU) No 801/2013 of 22 August 2
35、013 amending Regulation (EC) No 1275/2008 with regard to ecodesign requirements for standby, off mode electric power consumption of electrical and electronic household and office equipment, and amending Regulation (EC) No 642/2009 with regard to ecodesign requirements for televisions. i.3 Commission
36、 Regulation (EC) No 278/2009 of 6 April 2009 implementing Directive 2005/32/EC of the European Parliament and of the Council with regard to ecodesign requirements for no-load condition electric power consumption and average active efficiency of external power supplies. i.4 ETSI EN 301 575 (05-2012):
37、 “Environmental Engineering (EE); Measurement method for energy consumption of Customer Premises Equipment (CPE)“. i.5 European Commission Directorate-General, Joint Research Centre: “Code Of Conduct on Energy Consumption of Broadband Communication Equipment“; Final V5: 20 December 2013. NOTE: Avail
38、able at http:/iet.jrc.ec.europa.eu/energyefficiency/sites/energyefficiency/files/files/documents/ICT_CoC/cocv5-broadband_final.pdf. i.6 Cablelabs: “Data-Over-Cable Service Interface Specifications - DOCSIS2.0 Interface“. i.7 Cablelabs: “Data-Over-Cable Service Interface Specifications- DOCSIS3.0 Int
39、erface“. i.8 CENELEC EN 50643: “Electrical and electronic household and office equipment - Measurement of networked standby power consumption of edge equipment“. i.9 IEC 60050: “International Electrotechnical Vocabulary“. i.10 Commission Regulation (EC) No 642/2009 of 22 July 2009 implementing Direc
40、tive 2005/32/EC of the European Parliament and of the Council with regard to ecodesign requirements for televisions. i.11 IEC IEV ref 904-03-01: “Enviromental standardization for electrical and elctronic products and systems“. NOTE: Available at http:/www.electropedia.org/iev/iev.nsf/display?openfor
41、m and/or 2) manually switching the equipment into networked standby; b) the characteristics of the reactivation trigger (message, signal, etc.) that is used to reactivate the equipment when in networked standby and how to remotely initiate it; c) the maximum performance specifications, e.g. the maxi
42、mum speed or data rate supported by that networked port; d) the (maximum) power consumption of the equipment in a condition providing networked standby into which power management function, or a similar function, will switch the equipment, if only this port is used for remote activation, e.g. the de
43、clared power consumption of the equipment under defined conditions for a type of port; e) the communication protocol used by equipment; f) the radio frequency range at which each radio wireless logical network port operates; g) the characteristics of wireless logical network ports other than radio w
44、ireless logical network ports. NOTE: Annex D describes examples of product information for network equipment. 4.2 Power management function - periods the default period of time after which the power management function, or a similar function, switches the equipment automatically into a condition pro
45、viding networked standby. NOTE: According to European Regulation n 1275/2008 i.1 (as amended by EU Regulation n 801/2013 i.2), the maximum default period is given as 20 minutes during which the equipment has not been providing its main function. 4.3 Activation and deactivation of wireless network co
46、nnections The manufacturer shall provide information on the procedure the user needs to follow in order to activate and deactivate each wireless network connection, if any. The above requirement does not apply to equipment which relies on a single wireless network connection for intended use and doe
47、s not have a wired network connection. ETSI ETSI EN 303 423 V1.2.1 (2018-08) 12 5 Measurement conditions 5.1 Common requirements The general conditions for measurements specified in clause 4.1 of CENELEC EN 50564 1 shall apply. The tests described in clause 6 of the present document shall be repeate
48、d, if applicable, for each type of network port. Each type of logical network port (as declared by the manufacturer) using the same physical network port shall be tested. Where the manufacturer declares that multiple physical network ports have the same technical and logical specification(s), tests
49、shall be executed with any one of these physical network ports being connected (the other ones being deactivated for wireless network ports and disconnected for wired network ports). When a logical network port, as declared by the manufacturer, supports multiple editions of a communication technology standard (e.g. for backward compatibility), the logical network port is tested only according to the specifications of the latest standard edition used by the EUT for retrieving a reactivation message. Examples are shown
copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1