1、 ETSI TS 102 869-2 V1.4.1 (2015-07) Intelligent Transport Systems (ITS); Testing; Conformance test specifications for Decentralized Environmental Notification Basic Service (DEN); Part 2: Test Suite Structure and Test Purposes (TSS Essential, or potentially Essential, IPRs notified to ETSI in respec
2、t of ETSI standards“, which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web server (http:/ipr.etsi.org). Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee can be given as to the existence of othe
3、r IPRs not referenced in ETSI SR 000 314 (or the updates on the ETSI Web server) which are, or may be, or may become, essential to the present document. Foreword This Technical Specification (TS) has been produced by ETSI Technical Committee Intelligent Transport Systems (ITS). The present document
4、is part 2 of a multi-part deliverable covering Conformance test specification for Decentralized Environmental Notification Basic Service (DEN) as identified below: Part 1: “Test requirements and Protocol Implementation Conformance Statement (PICS) pro forma“; Part 2: “Test Suite Structure and Test P
5、urposes (TSS Part 3: “Abstract Test Suite (ATS) and Protocol Implementation eXtra Information for Testing (PIXIT)“. Modal verbs terminology In the present document “shall“, “shall not“, “should“, “should not“, “may“, “need not“, “will“, “will not“, “can“ and “cannot“ are to be interpreted as describ
6、ed in clause 3.2 of the ETSI Drafting Rules (Verbal forms for the expression of provisions). “must“ and “must not“ are NOT allowed in ETSI deliverables except when used in direct citation. ETSI ETSI TS 102 869-2 V1.4.1 (2015-07)51 Scope The present document provides the Test Suite Structure and Test
7、 Purposes (TSS Vehicular Communications; Basic Set of Applications; Part 3: Specifications of Decentralized Environmental Notification Basic Service“. 2 ETSI TS 102 869-1 (V1.4.1): “Intelligent Transport Systems (ITS); Testing; Conformance test specifications for Decentralized Environmental Notifica
8、tion Basic Service (DEN); Part 1: Test requirements and Protocol Implementation Conformance Statement (PICS) pro forma“. 3 ETSI TS 102 871-1 (V1.3.1): “Intelligent Transport Systems (ITS); Testing; Conformance test specifications for GeoNetworking ITS-G5; Part 1: Test requirements and Protocol Imple
9、mentation Conformance Statement (PICS) pro forma“. 4 ISO/IEC 9646-1 (1994): “Information technology - Open Systems Interconnection - Conformance testing methodology and framework - Part 1: General concepts“. 5 ISO/IEC 9646-2 (1994): “Information technology - Open Systems Interconnection - Conformanc
10、e testing methodology and framework - Part 2: Abstract Test Suite specification“. 6 ISO/IEC 9646-6 (1994): “Information technology - Open Systems Interconnection - Conformance testing methodology and framework - Part 6: Protocol profile test specification“. 7 ISO/IEC 9646-7 (1995): “Information tech
11、nology - Open Systems Interconnection - Conformance testing methodology and framework - Part 7: Implementation Conformance Statements“. 8 ETSI ETS 300 406 (1995): “Methods for testing and Specification (MTS); Protocol and profile conformance testing specifications; Standardization methodology“. ETSI
12、 ETSI TS 102 869-2 V1.4.1 (2015-07)62.2 Informative references References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the r
13、eference document (including any amendments) applies. NOTE: While any hyperlinks included in this clause were valid at the time of publication, ETSI cannot guarantee their long term validity. The following referenced documents are not necessary for the application of the present document but they as
14、sist the user with regard to a particular subject area. i.1 ETSI EG 202 798 (V1.1.1): “Intelligent Transport Systems (ITS); Testing; Framework for conformance and interoperability testing“. 3 Definitions and abbreviations 3.1 Definitions For the purposes of the present document, the terms and defini
15、tions given in ETSI EN 302 637-3 1, ISO/IEC 9646-6 6 and ISO/IEC 9646-7 7 apply. 3.2 Abbreviations For the purposes of the present document, the following abbreviations apply: ATS Abstract Test Suite BO Inopportune test events for Behaviour tests BTP Basic Transport Protocol BTP-B Basic Transport Pr
16、otocol Type B BV valid test events for Behaviour tests CAN Controller Area Network CLT Current Local Time DE Data Element DEN Decentralized Environmental Notification DENM Decentralized Environmental Notification Message EVGN Message transmission - Event Generation EVRP Message transmission - Messag
17、e Repetition EVTR Message transmission - Event Termination EVUP Message transmission - Event Update GBC Geographically-Scoped BroadcastISO International Organization for Standardization ITS Intelligent Transportation Systems ITS-S Intelligent Transport System - Station IUT Implementation Under Test
18、KAFW Keep-alive Forwarding MSGF Message Format MSRV Message receptionPAR Message transmission - Lower-layer parameters PDU Protocol Data Unit PICS Protocol Implementation Conformance Statement SSP Service Specific Permissions TI Timer testsTP Test Purposes TS Test SuiteTSS Test Suite Structure ETSI
19、ETSI TS 102 869-2 V1.4.1 (2015-07)74 Test Suite Structure (TSS) 4.1 Structure for DEN tests Table 1 shows the DEN Test Suite Structure (TSS) including its subgroups defined for conformance testing. Table 1: TSS for DEN Root Group category DEN Message format Valid Event Generation ValidEvent Update V
20、alid and Inopportune Event Termination Valid, Inopportune and Timer Message Repetition Valid Lower-layer parameters ValidMessage reception Valid and Inopportune Keep-alive Forwarding Valid and Timers The test suite is structured as a tree with the root defined as DEN. The tree is of rank 2 with the
21、first rank a functional area and the second rank is the standard ISO conformance test categories. 4.2 Test groups 4.2.1 Introduction The test suite has a total of three levels. The first level is the root. The second level separates the root into various functional areas. The third level is the stan
22、dard ISO conformance test categories. 4.2.2 Root The root identifies the Decentralized Environmental Notification Basic Service (DEN) given in ETSI EN 302 637-3 1. 4.2.3 Groups This level contains height functional areas identified as: Message format Event Generation Event Update Event Termination M
23、essage Repetition Lower-layer parameters Message reception Keep-alive Forwarding 4.2.4 Categories This level contains the standard ISO conformance test categories behaviour: valid events and inopportune events and Timer. ETSI ETSI TS 102 869-2 V1.4.1 (2015-07)85 Test Purposes (TP) 5.1 Introduction 5
24、.1.1 TP definition conventions The TP definition is built according to ETSI EG 202 798 i.1. 5.1.2 TP Identifier naming conventions The identifier of the TP is built according to table 2. Table 2: TP naming convention Identifier: TP/ = root DEN = group MSGF Message transmission - Message format EVGN
25、Message transmission - Event Generation EVUP Message transmission - Event Update EVTR Message transmission - Event Termination EVRP Message transmission - Message Repetition PAR Message transmission - Lower-layer parameters MSRV Message reception KAFW Keep-alive Forwarding = type of testing BV Behav
26、iour: Valid event tests BO Behaviour: Inopportune event tests TI Timer tests = sequential number 01 to 99 5.1.3 Rules for the behaviour description The description of the TP is built according to ETSI EG 202 798 i.1. ETSI EN 302 637-3 1 does not use the finite state machine concept. As consequence,
27、the test purposes use a generic “Initial State“ that corresponds to a state where the IUT is ready for starting the test execution. Furthermore, the IUT shall be left in this “Initial State“, when the test is completed. Being in the “Initial State“ refers to the starting point of the initial device
28、configuration. There are no pending actions, no instantiated buffers or variables, which could disturb the execution of a test. 5.1.4 Sources of TP definitions All TPs are specified according to ETSI EN 302 637-3 1. 5.1.5 Mnemonics for PICS reference To avoid an update of all TPs when the PICS docum
29、ent is changed, table 3 introduce mnemonics name and the correspondence with the real PICS item number. The PICS item column refers to Table/Item of ETSI TS 102 869-1 2. ETSI ETSI TS 102 869-2 V1.4.1 (2015-07)9Table 3: Mnemonics for PICS reference Mnemonic PICS item PICS_DENM_GENERATION A.2/1 PICS_D
30、ENM_UPDATE A.2/2PICS_DENM_REPETITION A.2/3PICS_DENM_CANCELLATION A.2/4PICS_DENM_NEGATION A.2/5PICS_DENM_RECEPTION A.2/6 PICS_DENM_KAF A.2/7PICS_IMPACT_REDUCTION A.12/2PICS_SECURITY ETSI TS 102 871-1 3, A.32/12 5.2 Test purposes for DEN 5.2.1 Message Transmission 5.2.1.1 Message Format TP Id TP/DEN/
31、MSGF/BV-01 Test objective Check that protocolVersion is set to 1 and messageID is set to 1 Reference ETSI EN 302 637-3 1, clause B.1 PICS Selection PICS_DENM_GENERATION Initial conditions with the IUT being in the “initial state“ Expected behaviour ensure that when the IUT receives an AppDENM_Trigge
32、r request from the application layer then the IUT sends a valid DENM containing ITS PDU header containing protocolVersion indicating value 1 and containing messageID indicating value 1 TP Id TP/DEN/ MSGF/BV-02 Test objective Check that sent DENM contains at least one trace DE Reference ETSI EN 302 6
33、37-3 1, clause 6.1.3.2 PICS Selection PICS_DENM_GENERATION Initial conditions with the IUT being in the “initial state“ Expected behaviour ensure that when the IUT receives an AppDENM_Trigger request from the application layer then the IUT sends a valid DENM containing location container containing
34、at least one trace ETSI ETSI TS 102 869-2 V1.4.1 (2015-07)105.2.1.2 Event Generation TP Id TP/DEN/EVGN/BV-01 Test objective Check that DEN Basic Service generates a new DENM on reception of a valid AppDENM_Trigger request Reference ETSI EN 302 637-3 1, clause 6.1.2.1 PICS Selection PICS_DENM_GENERAT
35、ION Initial conditions with the IUT being in the “initial state“ Expected behaviour ensure that when the IUT receives an AppDENM_Trigger request from the application layer then the IUT sends a valid DENM TP Id TP/DEN/EVGN/BV-02 Test objective Check that a new ActionID value is assigned for each newl
36、y generated DENM Reference ETSI EN 302 637-3 1, clause 6.1.1.1 PICS Selection PICS_DENM_GENERATION Initial conditions with the IUT being in the “initial state“ and the IUT having generated several events Expected behaviour ensure that when the IUT is requested to generate a new event then the IUT se
37、nds a valid DENM containing management container containing actionID indicating an unused value ETSI ETSI TS 102 869-2 V1.4.1 (2015-07)11TP Id TP/DEN/EVGN/BV-03 Test objective Check that a newly created ActionID contains the StationID of the originating ITS-S that detected the event Reference ETSI E
38、N 302 637-3 1, clause 6.1.1.1 PICS Selection PICS_DENM_GENERATION Initial conditions with the IUT being in the “initial state“ Expected behaviour ensure that when the IUT is requested to generate a new event then the IUT sends a valid DENM containing management container containing actionID containi
39、ng originatingStationID indicating its own StationID TP Id TP/DEN/EVGN/BV-04 Test objective Check that cause and subcause values included in DENM as provided by application Reference ETSI EN 302 637-3 1, clauses 7.1.4, B.17 PICS Selection PICS_DENM_GENERATION Initial conditions with the IUT being in
40、 the “initial state“ Expected behaviour ensure that when the IUT receives an AppDENM_trigger request from the application layer containing situation container containing eventType containing causeCode indicating Value1 containing subCauseCode indicating Value2 then the IUT sends a valid DENM contain
41、ing situation container containing eventType containing causeCode indicating Value1 containing subCauseCode indicating Value2 ETSI ETSI TS 102 869-2 V1.4.1 (2015-07)12TP Id TP/DEN/EVGN/BV-05 Test objective Check that referenceTime is set to the current time when generating a DENM for a new event Ref
42、erence ETSI EN 302 637-3 1, clause 8.2.1.3 PICS Selection PICS_DENM_GENERATION Initial conditions with the IUT being in the “initial state“ and the IUT having generated several events Expected behaviour ensure that when the IUT is requested to generate a new event then the IUT sends a valid DENM con
43、taining management container containing referenceTime indicating CLT TP Id TP/DEN/EVGN/BV-07 Test objective Check that sequenceNumber is set to a next unused value each time an event is detected Reference ETSI EN 302 637-3 1, clauses 6.1.1.1 and 8.2.1.2 PICS Selection PICS_DENM_GENERATION Initial co
44、nditions with the IUT being in the “initial state“ and the IUT having generated several events and the IUT having generated its last DENM containing management container containing actionID containing sequenceNumber indicating SEQ1 and no active event being associated with sequenceNumber SEQ1 + 1 Ex
45、pected behaviour ensure that when the IUT is requested to generate a new event then the IUT sends a valid DENM containing management container containing actionID containing sequenceNumber indicating SEQ1 + 1 ETSI ETSI TS 102 869-2 V1.4.1 (2015-07)13TP Id TP/DEN/EVGN/BV-08 Test objective Check that
46、sequenceNumber is set to a next unused value each time an event is detected (Sequence number wrap around) Reference ETSI EN 302 637-3 1, clauses 6.1.1.1 and 8.2.1.2 PICS Selection PICS_DENM_GENERATION Initial conditions with the IUT being in the “initial state“ and the IUT having generated several e
47、vents and the IUT having generated its last DENM containing management container containing actionID containing sequenceNumber indicating SEQ1 and an active event being associated with sequenceNumber SEQ1 + 1 and no active event being associated with sequenceNumber SEQ1 + 2 Expected behaviour ensure
48、 that when the IUT is requested to generate a new event then the IUT sends a valid DENM containing management container containing actionID containing sequenceNumber indicating SEQ1 + 2 TP Id TP/DEN/EVGN/BV-10 Test objective Check that actionID are generated using newly assigned stationID when a pse
49、udonym change occurs Reference ETSI EN 302 637-3 1, clause 6.1.1.2 PICS Selection PICS_DENM_GENERATION Initial conditions with the IUT being in the “initial state“ and the IUT having generated several events containing management container containing actionID containing originatingStationID indicating STATION_ID_1 and the IUT having changed its StationID Expect