1、 KSKSKSKS SKSKSKS KSKSKS SKSKS KSKS SKS KS 2006 9 18 KS C IEC 60888 KS C IEC 60888: 2006C IEC 60888: 2006 ( ) ( ) ( ) ( ) : : 2006 9 18 2006 0389 : : ( ) ( 02 509 72957) . 7 5 , . ICS 29.060.10; 29.240.20 KS C IEC 60888: 2006Zinc-coated steel wires for stranded conductors 1987 1.0 IEC 60888 Zinc-coa
2、ted steel wires for stranded conductors . 1. . 1.255.50 mm . , , 3 . : 1 2 2. , . 20 1 2 7.78 kg/dm3 11.510 6/ 3. . 99.85 % . . 4. , . 5. 90 2 . , III, IV V . . . 6. , % . . 40 C IEC 60888: 2006 2 7. , . 80 % , III, IV, V (UTS) 90 % . , / . . . 8. 10 % . , . 9. , . 10. . 10.1 1 % . I 2 I 3 250 mm (1
3、00 mm 200 mm . I 250 mm ). , . I 1 % mm MPa ( 250 mm)(*)1.24 2.25 100 0.125 2.25 3.00 200 0.250 3.00 4.75 300 0.375 4.75 5.5 400 0.500 (*) , / 250 mm . 1 % . , 1 % . III, IV, V . C IEC 60888: 2006 3 10.2 . 1 % , 0.1 , 0.4 . III, IV, V . 1 % . 10.3 , . a) 1 % . , . . , . III, IV, V . , ( III, IV, V )
4、, , 250 mm . b) (2 ) , . 2 . 2 % . . 60 . 100 III, IV, V . c) 15 8 III, IV, V . . 11. 11.1 . . . , . II . C IEC 60888: 2006 4 II mm g/m2 1 2 1.24 1.50 185 370 1.50 1.75 200 400 1.75 2.25 215 430 2.25 3.00 230 460 3.00 3.50 245 490 3.50 4.25 260 520 4.25 4.75 275 550 4.75 5.50 290 580 11.2 A . 11.3 B
5、 . 11.4 3.50 mm 4 3.50 mm 5 8 15 . (bare fingers) . 11.5 . . 12. , . C IEC 60888: 2006 5 III , mm mm 1 % MPa MPa %(*) X OD (*)1 1.24 2.25 0.03 1 170 1 340 3.0 1 18 2.25 2.75 0.04 1 140 1 310 3.0 1 16 2.75 3.00 0.05 1 140 1 310 3.5 1 16 3.00 3.50 0.05 1 100 1 290 3.5 1 14 3.50 4.25 0.06 1 100 1 290 4
6、.0 1 12 4.25 4.75 0.06 1 100 1 290 4.0 1 12 4.75 5.50 0.07 1 100 1 290 4.0 1 12 2 1.24 2.25 0.05 1 100 1 240 4.0 1 2.25 2.75 0.06 1 070 1 210 4.0 1 2.75 3.00 0.06 1 070 1 210 4.0 1 3.00 3.50 0.07 1 000 1 190 4.0 1 3.50 4.25 0.09 1 000 1 190 4.0 1 4.25 4.75 0.10 1 000 1 190 4.0 1 4.75 5.50 0.11 1 000
7、 1 190 4.0 1 (*) 250 mm . , 650/( 400 mm) . (*) : 100 IV , mm mm 1 % MPa MPa %(*) X OD (*)1 1.24 2.25 0.03 1 310 1 450 2.5 3 16 2.25 2.75 0.04 1 280 1 410 2.5 3 16 2.75 3.00 0.05 1 280 1 410 3.0 4 16 3.00 3.50 0.05 1 240 1 410 3.0 4 14 3.50 4.25 0.06 1 170 1 380 3.0 4 12 4.25 4.75 0.06 1 170 1 380 3
8、.0 4 12 4.75 5.50 0.07 1 170 1 380 3.0 4 12 2 1.24 2.25 0.05 1 240 1 380 2.5 3 2.25 2.75 0.06 1 210 1 340 2.5 3 2.75 3.00 0.06 1 210 1 340 3.0 4 3.00 3.50 0.07 1 170 1 340 3.0 4 3.50 4.25 0.09 1 100 1 280 3.0 4 4.25 4.75 0.10 1 100 1 280 3.0 4 4.75 5.50 0.11 1 100 1 280 3.0 4 (*) 250 mm . , 650/( 40
9、0 mm) . (*) : 100 C IEC 60888: 2006 6 V , mm mm 1 % MPa MPa %(*) X OD (*)1 1.24 2.25 0.03 1 450 1 620 2.0 4 14 2.25 2.75 0.04 1 410 1 590 2.0 4 14 2.75 3.00 0.05 1 410 1 590 2.5 5 12 3.00 3.50 0.05 1 380 1 550 2.5 5 12 3.50 4.25 0.06 1 340 1 520 2.5 5 10 4.25 4.75 0.06 1 340 1 520 2.5 5 10 4.75 5.50
10、 0.07 1 270 1 500 2.5 5 10 (*) 250 mm . , 650/( 400 mm) . (*) : 100 C IEC 60888: 2006 7 A A.1 . , . 1 g 101.3 kPa 0 0.343 1 . , . 5 mm . A.2 . a) 1 000 mL 3 20 g 3 32 g (1.16 1.18 ) b) (1.16 1.18 ) , a) 5 mL b) 100 mL . A.2.1 a) b) , ISO 1460(Metallic coatings Hot dip galvanized coatings on ferrous
11、materialsGravimetric determination of the mass per unit area) . A.3 100 mL . 100 mL 0.5 mL . , 1.5 mm , 50 mL 0.2 mL . A.4 , ( 1 % ) . , . AI . AI mm mm 100 mL mm 50 mL mm 1.24 1.8 100 75 1.8 3.6 75 3.6 5.50 50 A.5 . , . . , . C IEC 60888: 2006 8 . , . . , 2 . 0.01 mm . A.6 . / = fdlV V: d: l: f = 8
12、66 , . A.7 ( f ) 20 , 101.3 kPa . 98.7 kPa 104.0 kPa 18 22 , AII . 0.98 1.02 , . 5 g/m2 , . , . , . , 50 mL 100 mL . AII . AII kPa 69.3 72.0 74.7 77.3 80.0 82.7 85.3 88.0 90.7 93.3 96.0 98.7 101.3 104.0 106.712 0.703 0.730 0.758 0.784 0.811 0.839 0.866 0.892 0.920 0.947 0.974 1.001 1.028 1.055 1.082
13、14 0.698 0.725 0.752 0.779 0.806 0.833 0.860 0.886 0.914 0.940 0.967 0.994 1.021 1.048 1.07516 0.694 0.720 0.747 0.774 0.800 0.827 0.854 0.880 0.908 0.934 0.960 0.988 1.014 1.040 1.06818 0.689 0.715 0.742 0.768 0.795 0.822 0.848 0.874 0.901 0.927 0.954 0.981 1.007 1.033 1.06020 0.684 0.710 0.737 0.7
14、63 0.789 0.816 0.842 0.868 0.895 0.921 0.947 0.974 1.000 1.026 1.05322 0.679 0.705 0.732 0.758 0.783 0.810 0.836 0.862 0.889 0.915 0.940 0.967 0.993 1.019 1.04624 0.674 0.700 0.727 0.752 0.778 0.805 0.830 0.856 0.882 0.908 0.934 0.960 0.986 1.012 1.03826 0.670 0.696 0.722 0.748 0.773 0.800 0.825 0.8
15、51 0.877 0.903 0.928 0.955 0.980 1.005 1.03228 0.666 0.691 0.717 0.742 0.769 0.794 0.819 0.845 0.871 0.896 0.921 0.947 0.973 0.998 1.02530 0.661 0.687 0.713 0.738 0.763 0.789 0.814 0.839 0.865 0.891 0.916 0.942 0.967 0.992 1.018520 540 560 580 600 620 640 660 680 700 720 740 760 780 800 mmHg C IEC 6
16、0888: 2006 9 B B.1 - . . 0.01 g (g) (mm) 4 . , . A A.2 . B.2 A A.2 (a) (b) A.2.1 . . 40 . , 50 mm, 150 mm 100 mL . 1 100 mL 3 . , . (right) 2 0.01 mm . 0.01 g . B.3 . (g/m2) = 1 950 dr d: (mm) r: C IEC 60888: 2006 10 Zinc-coated steel wires for stranded conductors 1. Scope This standard applies to z
17、inc-coated steel wires used in the construction and or reinforcement of conductors for overhead power transmission purposes. It is intended to cover all wires used in constructions where the individual wire diameters, including coating, are in the range of 1.25 mm to 5.50 mm. Three grades of steel a
18、re included to reflect the needs of conductor users: regular steel, high strength steel and extra high strength steel. Two classes of coating represented by minimum zinc mass per unit area are included: Class 1 and Class 2. 2. Values for zinc-coated steel wires For calculation purposes the following
19、 values for zinc-coated steel wires shall be used: Density at 20 of both Class 1 and Class 2 7.78 kg/dm3Coefficient of linear expansion 11.510 6per 3. Material The steel wires shall have the properties specified hereinafter. The slab zinc shall be of 99.85 % minimum zinc content. The coating on the
20、wires may be applied by the hot dip or the electrolytic process. 4. Freedom from defects The uncoated wires shall be smooth and free from all imperfections not consistent with good commercial practice. The zinc-coated wires shall be reasonably smooth and free from all imperfections not consistent wi
21、th good commercial practice. 5. Diameter and tolerance on diameter The diameter of the zinc-coated steel wire shall be taken as the mean of two measurements taken at 90 at the same cross-section. The zinc-coated steel wires shall not depart from the nominal diameter, when measured over the coating,
22、by more than the amounts given in Tables III, IV and V. It is recognized that the surface of zinc-coatings, particularly those produced by hot dip galvanizing, are not perfectly smooth and free from irregularities. It is therefore intended that these tolerances be used in gauging the diameters withi
23、n the uniform areas of zinc-coated wire. 6. Length and tolerance on length Unless otherwise agreed between the purchaser and manufacturer, steel wires shall be supplied with a minimum length specified by the purchaser with a permitted variation of % Random lengths shorter or longer than this requirement are only acceptable if prior agreement between the purchaser and manufacturer is made. 4 0 C IEC 60888: 2006
copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1