ImageVerifierCode 换一换
格式:PDF , 页数:64 ,大小:1.20MB ,
资源ID:836261      下载积分:10000 积分
快捷下载
登录下载
邮箱/手机:
温馨提示:
如需开发票,请勿充值!快捷下载时,用户名和密码都是您填写的邮箱或者手机号,方便查询和重复下载(系统自动生成)。
如填写123,账号就是123,密码也是123。
特别说明:
请自助下载,系统不会自动发送文件的哦; 如果您已付费,想二次下载,请登录后访问:我的下载记录
支付方式: 支付宝扫码支付 微信扫码支付   
注意:如需开发票,请勿充值!
验证码:   换一换

加入VIP,免费下载
 

温馨提示:由于个人手机设置不同,如果发现不能下载,请复制以下地址【http://www.mydoc123.com/d-836261.html】到电脑端继续下载(重复下载不扣费)。

已注册用户请登录:
账号:
密码:
验证码:   换一换
  忘记密码?
三方登录: 微信登录  

下载须知

1: 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。
2: 试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。
3: 文件的所有权益归上传用户所有。
4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
5. 本站仅提供交流平台,并不能对任何下载内容负责。
6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

版权提示 | 免责声明

本文(NASA NACA-TN-2324-1951 Fatigue strengths of aircraft materials axial load-fatigue tests on unnotched sheet specimens of 24S-T3 and 75S-T6 aluminum alloys and of SAE 4130 steel《24S-.pdf)为本站会员(bowdiet140)主动上传,麦多课文库仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知麦多课文库(发送邮件至master@mydoc123.com或直接QQ联系客服),我们立即给予删除!

NASA NACA-TN-2324-1951 Fatigue strengths of aircraft materials axial load-fatigue tests on unnotched sheet specimens of 24S-T3 and 75S-T6 aluminum alloys and of SAE 4130 steel《24S-.pdf

1、t a c a 2 NATIONAL ADVISORY COMMITTEE FOR AERONAUTICS / TECHNICAL NOTE 2324 FATIGUE STRENGTHS OF AIRCRAFT MATERIALS AXLAL-LOAD FATIGUE TESTS ON UNNOTCHED SHEET SPECIMENS OF 24S-T3 AND 75S-T6 ALUMINUM ALLOYS AND OF SAE 4130 STEEL By H. J. Grover, S. M. Bishop, and L. R. Jackson Battelle Memorial Inst

2、itute Washington March 1951 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-NOTICE THIS DOCUM.ENT HAS BEEN REPRODUCED FROM THE BEST COPY FURNISHED US BY THE SPONSORING AGENCY. ALTHOUGH IT IS RECOGNIZED THAT CERTAIN PORTIONS ARE ILLEGIBLE, IT IS BEING

3、 RELEASED IN THE INTEREST OF MAKING AVAILABLE AS MUCH INFORMATION AS POSSIBLE. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-1 . NATIONAL ADVISORY COMMITTEE FOR AERONAUTICS TECHNICAL NOTE 2324 FATIGUE STRENGTHS OF AIRCRAFT MATERIALS AXIAL-LOAD FATI

4、GUE TESTS ON UNNOTCEED SHEET SPECIMENS OF 24S-T3 AND 75S-T6 ALUMINUM ALLOYS AND OF SAE 4130 STEEL By H. J. Grover, S. M. Bishop, and L. R. Jackson SUMMARY This report presents information on the axial-load fatigue behavior of unnotched specimens of each of three sheet materials: 75S-T6 aluminum allo

5、ys and normalized SAE 4130 steel. 24S-T3 and The experimental investigation of these materials included the following items: 1. Determination of fatigue strengths, in tests at a speed of about 1100 cycles per minute, covering a range of mean loads from zero to a high tensile value and, for each load

6、ing condition, lifetimes from 10,000 to 10,000,000 cycles 2. Determination of fatigue strengths in tests at a slower speed of about 90 cycles per minute 3. Several measurements of damage or strengthening at one stress level due to previous loading at another stress level; these tests included interc

7、hanging the order of application of high stress level and low stress level In several respects, fatigue test data are extended beyond thos,e previously available. However, results are in general agreement with such previously reported data as are available for comparison, The main observation unpred

8、ictable from previous work is that fatigue strengths at 90 cycles per minute appear, in some ranges of loading, appreciably lower (up to 10 percent) than corresponding strengths at 1100 cycles per minute. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,

9、-,-NACA TN 2324 INTRODUCTION A wartime survey (reference 1) showed a lack of complete information on the fatigue properties of sheet materials used in airframe construc- tion. Although a great deal of information was available, it appeared that no material had been investigated fully and that no str

10、ictly com- parative tests of large extent had been made on different materials under carefully controlled conditions. Therefore, it was planned to investi- gate rather fully the fatigue behavior of each of three metals commonly used in airframe construction: SAE 4130 steel. Each metal has been teste

11、d in one thickness (0.090 in. for the aluminum alloys and 0.075 in. for the steel), and all tests have been conducted under axial loading (of obvious importance in stressed- skin construction). 2bS-T3 and 75S-T6 aluminum alloys and The results, of interest in themselves, also furnish basic informa-

12、tion for further studies of the same materials. In view of this possi- bility, care has been taken to evaluate the experimental errors involved and to estimate, insofar as is possible, the residual “scatter“ of test points. This investigation was conducted at the Battelle Memorial Institute under th

13、e sponsorship and with the financial assistance of the National Advisory Committee for Aeronautics. Acknowledgment is due to Mr. David 0. Leeser, who, while on the staff of Battelle Memorial Institute, contributed a major part of the experimental work described in this report. The authors would also

14、 like to express appreciation to Mr. Paul Kuhn, of the Structures Research Division of the Langley Aeronautical Laboratory of the NACA at Langley Field, Virginia, for many helpful discussions during the course of the investigation. SHEET MATERIAL AND TEST SPECDENS Coupons cut from 135 sheets (0.090

15、in. thick) of each aluminum alloy and from 270 sheets (0.075 in. thick) of the steel were furnished by the NACA. Each sheet was laid out to provide four static tension blanks with the grain (rolling direction) and four static tension blanks across the grain, four static compression blanks with the g

16、rain and four static com- pression blanks across the grain, four fatigue test blanks with the grain, and a number of blanks for possible future use. As shown in figures 1 and 2, the layouts were such that a sample was taken from each section of each sheet for the various tests. Test pieces were mach

17、ined at Battelle from these coupons. . Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-NACA TN 2324 3 I- Static Test Specimens Static tension test coupons were machined to conform with the A.S.T.M. standard for sheet metals (reference 2). The static

18、compression test coupons were machined and ground 0.625 inch in width by 2.625 inches in length with ends parallel to each other and normal to the longitudinal or vertical axis of the specimen. Fatigue Test Specimens For fatigue test specimens, blanks of each material were cut approxi- mately 3 by 1

19、8 inches with the grain running the long dimension of the blank. These were protected on each face with a zinc chromate primer. With this coating still on, each blank was machined to the shape shown in figure 3. Previous experience had shown this to be a desirable speci- men for sheet fatigue tests

20、(reference 3). A reduction from a width of 1.000 to 0.800 inch in some of the steel specimens was necessitated by the load capacities of the available fatigue testing machines. Cross checks indicated that this decrease in width did not significantly affect test results. Specimens were polished elect

21、rolytically (after preliminary tests to justify this procedure for the materials concerned; see appendix A). TEST EQUIPMENT AND PROCEDURE Static Tests Tension tests were made in a Baldwin-Southwark universal testing machine with a Templin type recorder. Compression tests were made in the same machin

22、e with a Montgomery-Templin roller-type compression jig. Tests conducted at the Langley Aeronautical Laboratory showed that com- pression stress-strain curves obtained with the roller-type support were more accurate than curves obtained with other types of support available (reference 4). Loading ra

23、te for the static tests was 0.03 inch per minute. Fatigue Tests All fatigue tests were run on Krouse direct repeated-stress testing machines (reference 3) , one of which is shown in figure 4. have a nominal capacity of 10,000 pounds tension to 10,000 pounds com- pression. These machines When the mac

24、hines were operated at the normal speed of about I Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-4 NACA TN 2324 1100 cycles per minute, the determination of fatigue strengths covered a range of mean loads from zero to a high tensile value and, for

25、each loading condition, lifetimes from 10,000 to 10,000,000 cycles. A belt drive was arranged for the low-speed tests to give a speed of about 90 cycles per minute. The machines are of constant-deflection type; however, each is equipped with a sensitive means of detection of load decrease, so that t

26、ests can be generally considered as run at nearly constant load. Before this investigation was undertaken, the machines were recalibrated both statically and dynamically. The estimated pre- cision of setting and maintaining loads was about $3 percent for tension- tension tests and about k5 percent f

27、or tension-compression tests. Tension-tension tests were run with the self-alining type of grips used in previous investigations conducted at Battelle (reference 3). Measurements with bonded wire strain gages have shown that, with careful loading, the tension-tension grips have uniformity of stresse

28、s across the 1-inch gage length of a sheet specimen to about k500 psi. ment of the grips in the testing machine keeps bending stresses below about 500 psi. The aline- Tension-compression tests probably have somewhat less precision. Construction details of the tension-compression grips and guide plat

29、es are shown in figures 5 and 6. National Bureau of Standards (reference 5). There are two difficulties: This general method was developed at the (1) If the guide plates are too tight and specimens are not perfectly flat, an appreciable, unmeasured fraction of the applied load goes into friction (2)

30、 If the guide plates are too loose, the specimen buckles on the compression part of the cycle and bending stresses may become large Experiments with bonded wire strain gages were performed to determine optimum conditions for using the guide plates. These experiments are described in appendix B; it a

31、ppeared that errors did not exceed about 500 psi or 5 percent of maximum stress. Surface Finish Surface finish is known to be of major importance in determining fatigue strength. It appeared desirable to use a method of surface finishing which would: (1) Leave no transverse scratches (2) Slightly an

32、d reproducibly round edges to prevent development of “feather“ edges Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-NACA TN 2324 5 I- 1. - (3) Introduce negligible residual stresses (under 500 psi, if possible ) (4) Not cold-work the surface layers

33、(5) Be reasonably economical for use on the large number of speci- mens anticipated (6) Satisfactorily polish the roots of deep, narrow notches in anticipation of future tests to be run on notched specimens Several methods of mechanical polishj.ng were tried. was also investigated rather thoroughly

34、and was finally chosen as most nearly fulfilling the requirements listed above. Electropolishing While a considerable amount of work was done in selecting the sur- face finish, the results may be summarized briefly. Electropolishing gave as high (or higher) fatigue strengths on aluminum-alloy specim

35、ens as mechanical polishing, gave as little scatter in fatigue tests, presumably introduced negligible residual stresses, did not cold-work the surface, and was relatively simple and economical. Appendix A gives details of tests which were made to justify these conclusions. After polishing, fatigue

36、test specimens were coated with Vinylseal fcr protection against corrosion and against surface damage due to handling. This coating was removed, with acetone, only immediately before testing a given specimen. Testing Procedure Basic fatigue-strength values were obtained by testing specimens of each

37、type of sheet at constant-load ratios varying from R = 0.70 to R = -1.00 (R Min. stress/Max. stress). The range covered, as far as feasible, the values of fatigue strength for each material. Fatigue Damage Tests Fatigue damage tests were made for each material at a constant mean stress of one-fourth

38、 the ultimate tensile strength of that material. While this procedure has not been generally followed previously (refer- ences 6 to g), it seems useful for calculations with respect to gust loading (references 10 and 11). (one-fourth the ultimate tensile stress), while chosen arbitrarily, is one tha

39、t might be used in airframe design. The particular value of the mean stress Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-6 NACA TN 2324 s Tests were taken for each material at two levels of maximum stress. These levels were chosen with the followi

40、ng considerations: (1) The low level was above the relatively flat part of the S-N curve so that scatter in lifetime was not too large (2) The high level was below the yield stress (with some question in the case of 24S-T3) (3) The difference between stress levels was as great as possible in view of

41、 the above considerations A test was made in the following manner: One specimen was run at the higher stress for a predetermined fraction (say, one-half) of its average expected lifetime; it was then run to failure at the lower stress. A second specimen was run in the reverse order (lower stress for

42、 one-half of its expected life, then higher stress to failure). Each test was repeated on other specimens so as to obtain average results. The tests were then repeated with several different fractional lifetimes at the first stress level. A major purpose of these tests was to find out the effect of

43、order of occurrence of high and low stresses. EXPERIMENTAL FC3SULTS Static Strength Tests Table 1 gives the results of the static tension tests and the static compression tests on the three materials. The results of these static tests indicated that the sheet materials were up to standard in mechani

44、cal properties. The variations observed, from one sheet to another or from one specimen in a given sheet to another in the same sheet, were small in view of the precision possible in the fatigue tests. Fatigue Strength Tests Results of the fatigue tests for the 2kT3, 75S-T6, and SAE 4130 sheet speci

45、mens are given in tables 2, 3, and 4, respectively. (Some typical specimen failures are shown in fig. 7.) These results are shown plotted in the form of S-N curves in figures 8, 9, and 10. of scatter for the test data is illustrated in figure 11, which indi- cates that the scatter for the steel was

46、relatively slight. the S-N curves were extrapolated conservatively into the 1000- to 10,000-cycle range. The degree Some of Part of the difficulty in obtaining accurate values c Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-NACA TI1 2324 7 . in thi

47、s range, particularly at high load ratios, was attributed to the difficulty in maintaining loads well above the yield point and to the increase in strength due to the work-hardening effect. Some of the S-N curves represent intermediate test-ratio plots outlined with a few critical points and fitted

48、into the general pattern of the more com- pletely determined curves. Calculations indicated that, for a region f1/2 inch from the line of minimum cross section in each specimen, any variation in stress due to specimen shape was well within the loading precision (reference 3). The few specimens in wh

49、ich failures occurred beyond this region were not used in plotting the S-N curves. When the fatigue behavior of each material had been established for stresses up to the tensile yield point, some explorations at still higher stresses were pursued. It was anticipated that a specimen so loaded in the Krouse testing machines would elongate sufficiently to cause dif