1、A-A-50627 7777774 0166543 71T = (METRICI A-A-50629 9 February 1995 COMMERCIAL ITEM DESCRIPTION SIREN, ELECTRICAL, SHIPBOARD The General Services Administration has authorized the use of this commercial item description for all Federal Agencies. 1. Abstract. This commercial item description covers va
2、rious types of sirens for alarm and signalling purposes on naval ships. 2. Salient characteristics. 2.1 Mounting. Sirens shall be three-point vertically mounted as specified on figure 1. 2.2 Enclosure. Sirens shall be dripproof. Enclosure shall be tapped at the side for conduit or cable entrance. 2.
3、2.1 DriDDroof enclosure. An enclosure in which the openings are so constructed that drops of liquid or solid particles falling on the enclosure at any angle not greater than 15 degrees from the vertical either cannot enter the enclosure, or if they do enter the enclosure, they will not prevent the s
4、uccessful operation of, or cause damage to, the enclosed equipment (see IEEE 45). 2.2.2 Grounding and bonding. Metallic enclosures shall be provided with a stud for grounding and bonding. Resistance between the stud tip and any point of the enclosure or any exposed metallic components shall be zero
5、ohms when measured with a high quality ohmmeter. The stud shall be placed on the left side of the enclosure when viewed from the front of the siren. Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of use in improving this document should be addressed t
6、o: Commander, SEA 03R42, Naval Sea Systems Command, 2531 Jefferson Davis Hwy, Arlington, VA 22242-5160 by using the self-addressed Standardization Document Improvement Proposal: (DD Form 1426) appearing at the end of this document or by letter. AMSC N/A FSC 6350 DISTRIBUTION STATEMENT A. Approved fo
7、r public release; distribution is unlimited. Licensed by Information Handling ServicesA-A-50629 W 9999974 0166544 656 W A-A-50629 3 PL FIGURE 1. Mounting dimensions. 2 Licensed by Information Handling ServicesA-A-50629 = 9999974 0166545 592 = A-A- 50629 2.3 Electrical isolation. Electrical component
8、s shall be electrically isolated from the enclosure or any exposed metallic components. Electrical isolation shall be 100 megohm or greater when measured with a high quality, 500-volt megger. 2.4 TvDe. Sirens shall be of the following types, as specified (see 6.1): Freauencv OUtRUt 600 to 1200 Hz 10
9、3 decibel (dB) 1750 to 2500 Hz 103 dB Sound pressure output shall be based on a reference of 20 micropascal (pPa), and shall be measured at a distance of 3 m (meters) from the siren in accordance with ANSI S1.13. 2.5 Construction. Construction shall be such that no special tools are required for dis
10、assembly or reassembly. 2.6 Power. Operating voltages and frequencies shall be as specified (see Operating voltages shall be 115 volts direct current or root mean square 6.1). (rms) plus or minus 15 percent and operating frequency shall be 60 hertz (Hz) plus or minus 5 percent. 2.7 Preservation. Par
11、ts shall be of suitable corrosion resistant material or materials treated in a satisfactory manner to render them adequately resistant to corrosion. 3. Qualitv assurance provisions. 3.1 Contractor certification. The contractor shall certify and maintain substantiating evidence that the product offer
12、ed meets the salient characteristics of this commercial item description and that the product conforms to the pro- ducers own drawings, specifications, standards, and quality assurance practices. The Government reserves the right to require proof of such conformance prior to the first delivery and t
13、hereafter as may be otherwise provided for under the provisions of the contract. 3.2 Regulatorv resuirements. The offerer/contractor is encouraged to use recovered materials in accordance with Public Law 94-580 to the maximum extent practical. 4. Preservation, DackaginP. - uackine. labeling. and mar
14、king. The p tion, packaging, packing, labeling, and marking shall be as specified in contract or order. 5. CID based Dart identification number. The following part ident numbering procedure is for Government purposes and does not constitute a ment for the contractor. eserva- the f icat ion require-
15、3 Licensed by Information Handling ServicesA-A-50b29 = 9999974 OLbb54b 429 A-A-50629 .-A-50629 - 60A Example of part identification number. Variable characteristics 60 = type A - alternating current CID number Designated commercial item description (CID) 6. Notes. 6.1 Acsuisition requirements. Acqui
16、sition documents must specify the following: (a Type. 60 = 600 to 1200 HZ 103 dB 17 = 1750 to 2500 HZ 103 dB (b) Power. D = Direct current A = Alternating current (rms) C = Alternating or Direct current 6.2 Documents (a) NFPA-70, National Electrical Code, is available from National Fire Protection A
17、ssociation, One Batterymarch Park, P.O. Box 9101, Quincy, MA 02269-9101. available from American National Standards Institute, 11 West 42nd Street, 13th Floor, New York, NY 10036. board, is available from Institute of Electrical and Electronic Engineers, Inc., 445 Hoes Lane, P.O. Box 1331, Piscataway, NJ (b) ANSI S1.13, Methods for Measurement of Sound Pressure Levels, is (b) IEEE 45, Recommended Practice for Electric Installations on Ship- 08855-1331. CIVIL AGENCY COORDINATING ACTIVITY: GSA - FSS Preparing activity: Navy - SH (Project 6350-0139) Licensed by Information Handling Services