1、Beneficial comments, recommendations, additions, deletions, clarifications, etc. and any data that may improve this document should be sent to: Commander, Naval Sea Systems Command, ATTN: SEA 05M2, 1333 Isaac Hull Avenue, SE, Stop 5160, Washington Navy Yard DC 20376-5160 or emailed to CommandStandar
2、dsnavy.mil, with the subject line “Document Comment”. Since contact information can change, you may want to verify the currency of this address information using the ASSIST Online database at http:/assist.daps.dla.mil. FSC 4730 INCH-POUND A-A-59822 12 February 2009 COMMERCIAL ITEM DESCRIPTION PLUG A
3、SSEMBLIES, GRIPPERS, OD AND ID TYPES FOR TEMPORARY PRESSURE TESTING OF WATER, OIL AND GAS TRANSMISSION PIPING The General Services Administration has authorized the use of this commercial item description, for all federal agencies. 1. SCOPE. This commercial item description describes high pressure h
4、ydrostatic test plugs and fittings (hereafter referred to jointly as “plugs”) that can be used to make mechanical attachments to pipes, tubes, and other piping fittings (hereafter referred to jointly as “pipes”), for the purposes of isolating components and making pressure seal boundaries for hydros
5、tatic testing. As a secondary function, the test plug provides a means for making a connection of the hydrostatic test medium and pressure. 2. CLASSIFICATION. The hydrostatic test plugs shall be of the following types: Type I Hydrostatic test plugs that are installed in and seal on the pipe internal
6、 diameter. Type II Hydrostatic test plugs that are installed on and seal on the pipe outside diameter. 3. SALIENT CHARACTERISTICS. 3.1 Size. 3.1.1 Standard sizes. 3.1.1.1 Type I. Type I hydrostatic test plugs shall be provided in sizes that can be used in the series of pipe diameters and schedules o
7、r classes shown in table I. TABLE I. Pipe sizes for type I hydrostatic test plugs. Pipe Material Schedule or Class National Pipe Sizes inches 40 1, 1, 1, 2, 2, 3, 3, 4, 5, 6, 8, 10 80 1, 1, 1, 2, 2, 3, 3, 4, 5, 6, 8, 10 120 4, 5, 6, 8, 10 160 1, 1, 112, 2, 212, 3, 4, 5, 6, 8, 10 XS 10 Standard Steel
8、 Pipe XXS 1, 1, 1, 2, 2, 3, 3, 4, 5, 6, 8 5 S 1, 1, 1, 2, 2, 3, 3, 4, 5, 6, 8 Stainless Steel Pipe 10 S 1, 1, 112, 2, 212, 3, 312, 4, 5, 6, 8 90-10 Copper-Nickel Pipe/Tubing 200 As defined in MIL-T-16420 200 700 1650 3300 70-30 Copper-Nickel Pipe/Tubing 6000 As defined in MIL-T-16420 Provided by IHS
9、Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59822 2 3.1.1.2 Type II. Type II hydrostatic test plugs shall be sized to apply to the following standard nominal pipe sizes: -inch, 38-inch, -inch, -inch, 1-inch, 1-inch, 1-inch, 2-inch, 2-inch, and 3-inch, or as
10、 defined by MIL-T-16420. 3.1.1.3 Tolerances. For Type I or II plugs intended for use in standard pipe sizes, the dimensions shall be such that the plug can be properly set and used in pipes with diametrical and wall thickness dimensional tolerance ranges as specified in table II. TABLE II. Tolerance
11、s for standard pipe. Type of Pipe Standard for Outside Diameter Tolerance Standard for Wall Thickness Tolerance Standard Steel Pipe ASTM A530/A530M ASME B36.10 Stainless Steel Pipe ASTM A530/A530M ASME B36.19 Copper-Nickel Pipe/Tubing MIL-T-16420 MIL-T-16420 3.1.2 Non-standard sizes. For plugs requi
12、red for service in non-standard dimensioned pipes, the dimensional design shall be suitable for use in outside and inside diameter tolerance ranges, and/or wall thickness tolerance ranges, as provided by the purchaser. 3.2 Marking. Hydrostatic test plug assemblies shall be marked by stamping or othe
13、r permanent means that will not be subject to degradation by corrosion or contact with water. Marking shall be done on a prominent location that does not interfere with the sealing or gripping function. Characters shall be at least -inch high. All assemblies shall be marked with the following: a. Ma
14、nufacturers name, abbreviation, acronym, or symbol b. Manufacturers part number c. Maximum pressure rating of the plug in pounds per square inch gauge (see 3.4.4) d. Notation if a safety gag is required (see 3.4.9) e. Drawing Number f. Material Type g. Material Specification h. Additionally, the fol
15、lowing items shall be included in the marking for the specific hydrostatic test plug types: Type I: The internal pipe diameter range, in inches, over which the hydrostatic test plug can be installed and set properly. Type II: The Nominal Pipe Size (NPS) diameter, in inches, for which the hydrostatic
16、 test plug is intended. 3.3 Materials. All pressure containing materials shall be metallic except for the expandable mechanical stopper material, and any other seals or o-rings required. Materials shall be selected based on a service temperature range of 60 to 120 F and shall be resistant to corrosi
17、on or degradation in fresh water service. 3.4 Design details. 3.4.1 General design. In general, hydrostatic test plugs shall contain: expandable mechanical stopper seals or other sealing devices to seal against the surface of the pipe being tested, gripper assemblies to grip the surface of the pipe
18、in order to ensure against ejection of the plug during hydrostatic testing, and wedging devices activated by tightening the plug fitting(s) in order to activate the gripping elements and the seals. See figures 1 and 2 for a typical OD and ID type design. Provided by IHSNot for ResaleNo reproduction
19、or networking permitted without license from IHS-,-,-A-A-59822 3 FIGURE 1. Typical OD hydro test plug (for information only). FIGURE 2. Typical ID hydro test plug (for information only). 3.4.2 Porting. The hydrostatic test plugs shall have a central port that connects the pressurized region of the p
20、ipe being hydrostatically tested to an outside, external fitting to which the hydrostatic pressure source pump can be connected. This fitting shall have an appropriately sized male or female pipe thread, conforming to ASME B1.20.1 tapered National Pipe Thread (NPT) inch-series threads or as specifie
21、d by the buyer. The hydrostatic plug shall be supplied with a pipe cap or plug which can be used to seal the port. 3.4.3 Design of pressurized components. All components subjected to the hydrostatic pressure shall be designed in accordance with the ASME Boiler and Pressure Vessel Code, for a maximum
22、 allowable working pressure at least 1.5 times as great as the pressure rating stamped on the fitting. All components subjected to hydrostatic pressure shall be designed in accordance with the ASME Boiler and Pressure Vessel Code Section B31.1 or alternate method of design as approved by NAVSEA. The
23、 design shall be for the maximum allowable working pressure of the components using the material allowable stresses as dictated by the Code. Designs for which the maximum allowable working pressure cannot be computed with satisfactory assurance, refer to ASME Boiler and Pressure Vessel Code Section
24、B31.1 or the ASME Boiler and Pressure Vessel Code Section VIII (Proof tests to establish maximum allowable working pressure). All hydrostatic test plugs shall be proven through hydrostatic testing using a test fixture representative of the intended final use. The test medium shall be fresh water at
25、room temperature. The test shall be conducted after the fitting has been installed in the test fixture bore using the manufacturers recommended tightening procedure. The test pressure shall be maintained for a minimum of 10 minutes. The fitting shall not blow out of the fixture or noticeably shift i
26、n position, and shall not leak. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59822 4 3.4.4 Pressure rating. The pressure rating stamped or marked on the hydrostatic test plug shall be at most the lesser of either two thirds the design pressure
27、 (see 3.4.3) or two thirds the pressure required to produce the holding load for which the plug is designed (see 3.4.6). The manufacturer has the option of using a pressure rating less than this, based on the maximum pressure rating of the pipe material, size, and schedule for which the hydrostatic
28、test plug is specifically designed. 3.4.5 Gripper assemblies. Hydrostatic test plugs shall be provided with segmented, serrated gripper assemblies that are spring loaded or otherwise configured to be activated when tightening the hydro plug fittings and to readily relax when pressure is removed and
29、the fitting loosened. The gripping assemblies shall contact and grip the inside diameter surface of the pipe, tube, or fitting in Type I designs, and the outside diameter surface in Type II designs. In the installation of the hydrostatic test plug in the pipe, tube, or fitting ,the gripper assemblie
30、s shall be set to the proper contact force against the surface by the tightening of the plug nuts or other fittings used for setting the fixture. 3.4.6 Holding load. The gripper assembly design shall be such that when the hydrostatic test plug is properly set in accordance with manufacturers instruc
31、tions, the entire holding load preventing blowout of the fitting at the maximum pressure, as defined in 3.4.4, will be provided by the gripper assembly contact force alone. Any holding force provided by the seal shall be extra holding force and shall not be required for keeping the plug from dischar
32、ging from the pipe or fitting at the maximum qualification test pressure. 3.4.7 Insertion depth. Hydro plug assemblies shall be provided with dimensional offsets, as required, to ensure that the entire gripper assembly length will be contacting the pipe or fitting when the hydrostatic test plug is i
33、nstalled in any standard design pipe or fitting end. 3.4.8 Surface marking. Gripper elements shall not cause surface marking in pipe surfaces deeper than 10 mils. 3.4.9 Safety gag. At the manufacturers option, a safety gag may be provided with the hydrostatic test plug that links the plug to a clamp
34、 that is secured on the pipe. If this gag is required by the manufacturer in order to ensure that the plug will not eject upon hydrostatic testing, the plug shall be marked indicating that the gag is required. 3.4.10 External pipe support clamps. When requested (see 6.3), the manufacturer shall supp
35、ly clamped external pipe support rings to be used with Type I hydrostatic test plugs. These clamps shall be sized for the external diameter of the pipe, and shall be dimensioned so that the clamp abutting faces are flush at an external pipe diameter at the negative of the diametrical tolerance as gi
36、ven in table II. The support clamps shall be designed to prevent the flaring of the pipe by the Type I hydrostatic plug gripper element. 4. PRODUCT CONFORMANCE PROVISIONS. 4.1 Product conformance. The products provided shall meet the salient characteristics of this Commercial Item Description, confo
37、rm to the producers own drawings, specifications, standards, and quality assurance practices, and be the same product offered for sale in the commercial marketplace. The government reserves the right to require proof of such conformance. 5. PACKAGING. Preservation, packing, and marking shall be as s
38、pecified in the contract or order. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59822 5 6. NOTES. 6.1 Part or Identification Number (PIN). The following PIN procedure is for government purposes and does not constitute a requirement for the con
39、tractor. This example describes a part numbering system for CID A-A-59822. AA59822-1-03000-02440-02540-1-2 External clamp: 1 Required 2 None Gag: 1 Required 2 None Maximum diameter: Maximum (OD or ID) diameter of applicable piping in inches (5 digits, in thousandths of an inch) Minimum diameter: Min
40、imum (OD or ID) diameter of applicable piping in inches (5 digits, in thousandths of an inch) Pressure: Maximum allowable working pressure in pounds per square inch (maximum 5 digits) Type: 1 Type I (Internal mounted hydro plug) 2 Type II (External mounted hydro plug) CID number For example, AA59822
41、-1-03000-02440-02540-1-2 represents an internal mounted hydro plug, 3000 pounds per square inch working pressure, a diameter of 2.440 inches to 2.540 inches, with a gag required, and no external clamp. 6.2 Source of documents. 6.2.1 ASME International. ASME International documents are available from
42、 ASME International, 22 Law Drive, PO Box 2900, Fairfield, NJ 07007-2900 or online at www.asme.org. 6.2.2 ASTM International. ASTM International documents are available from ASTM International, 100 Barr Harbor Dr., PO Box C700, West Conshohocken, PA 19428-2959 or online at www.astm.org. 6.2.3 Milita
43、ry specifications. Military specifications are available at http:/assist.daps.dla.mil/quicksearch/ or http:/assist.daps.dla.mil or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094. Provided by IHSNot for ResaleNo reproduction or networking pe
44、rmitted without license from IHS-,-,-A-A-59822 6 6.3 Ordering data. The contract or order should specify the following: a. CID document number, revision, and title. b. Whether a Type I or Type II plug is required. c. Product conformance provisions including certification documentation that all hydro
45、static test plugs meet the pressure requirements. d. Pipe diameter and schedule or class for standard pipe sizes. e. Specific pipe outside diameter, inside diameter and/or wall thickness, for non-standard sizes. f. Required minimum pressure rating. g. Quantity required. h. Whether an external pipe s
46、upport ring is required with Type I plugs, and pipe diameter, if required (see 3.4.10). i. Packaging, preservation, and marking requirements. 6.4 Potential sources. Based on information available at the time this document was developed, the following companies manufacture products that are believed
47、to comply with the salient characteristics of this CID: Expansion Seals Technology Group, Inc. 334 Godshall Drive Harleysville, PA 19438-2008 Hy-Tech Machine, Inc. Mashuda Industrial Park 25 Leonberg Road Cranberry Twp, PA 16066 Sealfast Products 3501B S. 26thSt. Manitowoc, WI 54220 6.5 Key words. H
48、ydro Hydrostatic test Pipe plug Pipe stopper Test plug MILITARY INTERESTS CIVIL AGENCY COORDINATING ACTIVITY: GSA - FAS Custodians: Navy - SH Preparing Activity: Air Force - 99 Navy - SH (Project 4730-2007-017) Review Activities: Navy - AS, NP Air Force - 03, 71 DLA - CC GSA - FAS NOTE: The activiti
49、es listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at http:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-
copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1