1、MIL-D-2477C (LI 73 m 99999Ob 0238908 8 m MIL-D-2477C AMENDMENT-1 17 June 1981 MILITARY SPECIFICATION &. DOUGH MOULDING MACHINES, LOAF This amendment forms a part of Military Specification MIL-D-2477C, dated 29 February 1968,. and is approved for use by all Departments and Agencies of the Department
2、of Defense. PAGE 1 2.1 Add the following paragraph title: “Issues of documents“. under “SPECIFICATIONS FEDEU“: Delete “CC-M-636“ AND “CC-M-641“ and their titles, and substitute: “CC-M-1807 - Motors, Alternating Current, Fractional and Integral Horsepower (500 HP and Smaller)“. PAGE 2 2.1, under “STA
3、NDARDS MILITARY“: Delete title for “MIL-STD-461“ and substitute “Electromagnesic Emission and Susceptibility Requirements for the Control of Electromagnetic Interference“. 2.2, line 4, after “STANDARD“: Add “COMMITTEE“. lines 8 thru 12, delete all references to “UNDERWRITERS LABORATORIES, INC. (UL)“
4、. 3.1 Delete. PAGE 3 3.3 Delete and substitute: “3.3 Standards. The complete dough molding machine shall conform to the requirements of BISSC Standard No. 9 for Bread Moulders.“ 3.3.1 Delete and substitute: “3.3.1 Certification. Prior to approval of the first shipment, the contractor shall submit sa
5、tisfactory evidence to the contracting officer or his authorized representative that the electrical components and the dough molding machine(s) he proposes to furnish under this specification meet the requirements of BISSC Standard NO. 9.“ FSC 7320 Provided by IHSNot for ResaleNo reproduction or net
6、working permitted without license from IHS-,-,- MIL-D-2477C (1) 73 M 7777906 0238707 T W MIL-D-2 47 7C Amendment - 1 PAGE 3 (contd) 3.3.2 Delete. 3.4, at nd.of paragraph: Add “(see 6.6).“ 3.4.1, delete first sentence and substitute: C C-M- 1 8 O 7 . “ line 2: Delete “continous“ and substitute: “cont
7、inuous“. “Electric motors shall conform to Add the following new paragraph: “3.5.1 Type I. When specified for shipboard use (see 6.2), the type I dough moulding machine shall be designed to operate on a nominal 120 volt, 60 hertz, single phase power source and have the additional capability to produ
8、ce hoagie and frankfurter rolls. following: The maximum overall dimensions of the dough moulding machine shall be 28 inches wide by 63 inches long and 60 inches high.“ Also, the machine shall be equipped with one each of the a 5-5/8 inch plate, a 10 inch plate and an 11 inch plate. PAGE 5 . 3.7 Dele
9、te and substitute: “3.7 Electromagnetic compatibility. When specified (see 6.2), the dough molding machines shall be designed and equipped for electromagnetic compatibility in accordance with part 10, class C3, group 1 of MIL-STDi461 (see 4.5.2).“ PAGE 6 3.11, line 3: Delete “froo acess“ and substit
10、ute “free access“. 4.2 Delete. Add the following new paragraph: “4.3 Quality conformance inspection. Unless otherwise specified, sampling for inspection shall be performed in accordance with MIL-STD-105.“ PAGE 7 Table I, opposite examination for “Construction and workmanship, general (applicable to
11、all components and assemblies).“ component part omitted or not as specified -Major X“. Add the following new defect: “Any Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-D-ZLI77C (1) 73 W 77777Ob 023B9LO b M PAGE 9 MIL-D-2 47 7C Amendment -1 c 4.
12、3.3 Delete first sentence. 4.5.2 Delete and substitute: “4.5.2 Electromametic compatibility. When electromagnetic compatibility is required, one end item from the initial production lot shall be tested by the contractor in accordance with test methods of MIL-STD-462. the right to witness the test pe
13、rformed by the contractor or by an independent testing agency. certification that the Interference Control Plan, the EMI/EMC Test Plan, and the Electromagnetic Compatibility Test Report meet the requirements of MIL-STD-461.“ The Government reserves The contractor shall furnish the contracting office
14、r written 6.2, (c) Delete and substitute the following: “(c) When electromagnetic compatibility is required (see 3.7).“ PAGE 10 6.3 Delete. 6.6 Add the following new paragraph: “6.6 Recycled material. It is encouraged that recycled material be used when ,practical as long as it meets the requirement
15、s of the specification (see 3.4).“ Custodians: Preparing activity: Army - GL Navy - YD Air Force - 99 . Project No. 7320-0474 Army - GL Review activities: Army - CR, MD Navy - SA DU - GS User activity: Navy - MC Page 3 of 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-