1、 INCH-POUND MIL-DTL-22244F (OS) 7 February 2012SUPERSEDING MIL-DTL-22244E (OS) 27 May 1997 DETAIL SPECIFICATION CARTRIDGE, IMPULSE, MARK 23 MOD 0 This specification is approved for use by the Naval Sea Systems Command, Department of the Navy, and is available for use by all departments and agencies
2、of the Department of Defense. 1. SCOPE 1.1 Scope. This specification covers the requirements for the manufacture and acceptance of the Mark 23 Mod 0 Impulse Cartridge (see 6.1). 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this section are specified in sections 3, 4 or 5 of this spec
3、ification. This section does not include documents cited in other sections of this specification or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned that they must meet all specified requirem
4、ents documents specified in Sections 3, 4 or 5 of this specification, whether or not they are listed. 2.2 Government documents. 2.2.1 Specifications, standards, and handbooks. The following specifications, standards, and handbooks form a part of this document to the extent specified herein. Unless o
5、therwise specified, the issues of these documents are those cited in the solicitation or contract. DEPARTMENT OF DEFENSE SPECIFICATIONS MIL-D-21625 Design and Evaluation of Cartridge Actuated Devices MIL-DTL-83420 Wire Rope, Flexible, for Aircraft Control DEPARTMENT OF DEFENSE STANDARDS DOD-STD-2101
6、 Classification of Characteristics Comments, suggestions, or questions on this document should be addressed to Department of the Navy, Indian Head Division, NSWC, Code E12P, Document Control, 4123 Artisans Court, Suite 103, Indian Head, Maryland 20640-5085, OFFICIAL BUSINESS, or emailed to amanda.pe
7、nnnavy.mil. Since contact information can change, you may want to verify the currency of this address information using the ASSIST Online database at https:/assist.daps.dla.mil/. AMSC N/A FSC 1377 Distribution Statement A: Approved for public release: distribution is unlimited. Provided by IHSNot fo
8、r ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-22244F (OS) 2 (Copies of these documents are available online at https:/assist.daps.dla.mil/ or from the Standardization Documents Order Desk, Building 4D, 700 Robbins Avenue, Philadelphia PA 19111- 5094.) 2.2.2 Oth
9、er Government documents, drawings, and publications. The following other Government documents, drawings, and publications form a part of this document to the extent specified herein. Unless otherwise specified, the issues are those cited in the solicitation or contract. DRAWINGS Naval Air Systems Co
10、mmand (Code Ident 30003) DL491837 Cartridge, Impulse, Mark 23 Mod 0 1861735 Unloaded Shell Assembly PUBLICATIONS Naval Sea Systems Command (Code Ident 53711) OP 5 Ammunition and Explosives Ashore (Application for copies should be addressed to the Commanding Officer, Naval Publications and Forms Cent
11、er, Attn: 1053, 5801 Tabor Avenue, Philadelphia, PA 19120-5099.) 2.3 Non-Government publications. The following documents form a part of this document to the extent specified herein. Unless otherwise specified, the issues of the documents are those cited in the solicitation or contract. AMERICAN SOC
12、IETY FOR TESTING AND MATERIALS (ASTM) ASTM E 545 Image Quality in Direct Thermal Neutron Radiographic Examination (Copies of this document are available online at http:/www.astm.org/ or from the American Society for Testing and Materials Customer Service, 100 Barr Harbor Drive, West Conshohocken, PA
13、 19428-2959.) 2.4 Order of precedence. Unless otherwise noted herein or in the contract, in the event of a conflict between the text of this document and the references cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulat
14、ions unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 First article. When specified (see 6.2), a sample shall be subjected to first article inspection in accordance with 4.3. 3.2 Conformance to documents. The Mark 23 Mod 0 Impulse Cartridge covered by this specification shall be ma
15、nufactured in accordance with DL491837. 3.3 Materials. All materials used in the manufacture of the cartridges shall conform strictly to the Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-22244F (OS) 3 specifications referred to on the respe
16、ctive drawings. When alternate materials or methods of manufacture are specified on the drawings, the bidders selections shall be clearly stated in the proposal. 3.4 Bridgewire. The bridgewire shall be soldered in place as specified on Drawing 1861735. 3.5 Bridgewire continuity. The bridgewire shall
17、 glow when subjected to the continuity test (see 4.5.4). 3.6 Unloaded shell assembly leakage. The unloaded shell assembly shall not leak (see 4.5.5). 3.7 Propellant charge. 3.7.1 Quantity. All propellant charges shall be determined by weight rather than by volume measurement. 3.7.2 Smokeless powder:
18、 handling, and loading. The smokeless powder shall be subjected to no unnecessary handling or exposure to the atmosphere. The handling and loading of smokeless powder exposed to the atmosphere shall be performed only under conditions that do not permit the relative humidity to exceed 75 percent. 3.7
19、.3 Smokeless powder, condition. The smokeless powder used shall exhibit no evidence of decomposition (see 4.5.1). 3.8 Cartridge inspection. 3.8.1 Bridge circuit resistance. The resistance of the bridge circuit in each completely assembled cartridge, when measured electrically (see 4.5.3), shall be n
20、ot less than 3.0 ohms nor greater than 6.5 ohms. 3.8.2 N-ray. Cartridges shall be free of imperfections when N-rayed (see 4.5.6). 3.9 Ballistic requirements. Cartridges shall meet the ballistic requirements specified in 3.9.1 through 3.9.3 when subjected to the test of 4.5.7. 3.9.1 Output. Cartridge
21、s shall furnish sufficient power to completely sever the steel cable specified in 4.5.7. 3.9.2 Misfire. There shall be no misfires (see 4.5.7.2). 3.9.3 Hangfire. There shall be no hangfires (see 4.5.7.3). 3.10 Workmanship. Cartridges shall be free of the following defects: burrs, dents, incomplete o
22、r damaged threads, improper crimp, perforated closure disc, bent pins, or other defects which may prevent entry of the cartridge into the firing chamber, or affect resistance of the cartridge to moisture. All cartridge marking and identification shall be verified as proper (see 4.5.2). 4. VERIFICATI
23、ON 4.1 Classification of inspections. a. First article inspection (see 4.3) Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-22244F (OS) 4 b. Quality conformance inspection (see 4.4) 4.2 Inspection conditions. Unless otherwise specified, all i
24、nspections shall be performed in accordance with the test conditions specified in 4.5. 4.3 First article inspection. First article inspection shall be performed after award of contract and prior to production by a facility designated in the contract or order (see 6.2). A first article sample accepta
25、ble for environmental and function testing shall be considered a sample which has met the requirements of 3.2 through 3.8.2 and 3.10. First article inspection shall be performed on sample units which have been produced using the same materials, equipment, processes, and procedures as will be used in
26、 regular production. All parts and materials, including packaging and packing shall be the same as used for regular production and shall be from the same sources of supply. 4.3.1 Sample size. The first article sample shall consist of 66 cartridges plus retain samples. 4.3.2 Inspection routine. Sixty
27、-six cartridges shall be expended in the tests listed below and a quantity, specified in the contract, of retain samples used for investigative purposes. Testing shall consist of the following tests as prescribed in MIL-D-21625F: 40-foot drop (6); temperature and humidity cycling (12), except that 1
28、4 days shall be used in lieu of 28 days; vibration (12); -65F temperature (12); 160F temperature (12); 70F temperature (12). The number in parenthesis denotes the number of cartridges allocated for each test. No cartridge shall produce results which fail to meet the requirements of 3.9.1 through 3.9
29、.3. Firings shall be conducted in the test fixture of 4.5.7. 4.3.3 Failure. Failure of any cartridge shall be cause for rejection of the first article sample. 4.4 Quality conformance inspection. Quality conformance inspection shall consist of the tests and examinations specified in table I and verif
30、ication of the characteristics classified on the drawings of DL491837. 4.4.1 Lot size. Unless otherwise specified (see 6.2), the production lot size shall be not less than 281 and not greater than 10,000. Only primary components from a single lot shall be used in a production lot of cartridges; howe
31、ver, one primary component lot may be used in more than one cartridge production lot. 4.4.2 Sampling. Unless otherwise specified (see 6.2), sampling shall be in accordance with table II. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-22244F
32、(OS) 5 TABLE I. Quality conformance tests and examinations. Item Nature of test Requirement Test method Classification (DOD-STD-2101) Bridgewire Soldering 3.4 (M101) Bridgewire Continuity 3.5 4.5.4 (C1) Unloaded shell assembly Leakage 3.6 4.5.5 (C2) Propellant charge Type and weight 3.7.1 (C3) Smoke
33、less powder Condition 3.7.3 4.5.1 (C4) Cartridge Visual inspection 3.10 4.5.2 (M102) Cartridge Bridgewire resistance 3.8.1 4.5.3 (C5) Cartridge N-ray 3.8.2 4.5.6 (C6) Cartridge Ballistics 3.9 4.5.7 (C7) Cartridge Preservation-packaging, packing, and marking Section 5, Contract 4.5.2 (M103) TABLE II.
34、 Quality conformance sample size. Lot size Sample size Retained sample 51 to 90 13 * 91 to 150 20 * 151 to 280 32 * 281 to 500 50 * 501 to 1200 80 * 1201 to 3200 125 * 3201 to 10,000 200 * 10,001 to 35,000 315 * * Quantity to be specified in the contract. 4.4.3 Classification of characteristics. The
35、 characteristics verified by the tests and examinations herein are classified as Critical, Major or Minor in accordance with DOD-STD-2101. Tests and examinations that verify critical characteristics are identified by the symbol (C) and major characteristics by the symbol (M). The number following th
36、e classification symbol indicates the serial number of test or examination. Tests and examinations which are not annotated with a classification code are classified minor. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-22244F (OS) 6 4.5 Test
37、s. 4.5.1 Smokeless powder, condition. Smokeless powder shall be inspected in accordance with the applicable paragraphs of OP 5. Evidence of decomposition shall be cause for rejection. 4.5.2 Visual examination. All cartridges shall be visually examined. Cartridges having any of the defects of 3.10 sh
38、all be cause for rejection. The preservation-packaging, packing, and marking of the cartridges shall be examined for conformance to section 5 and the contract (see 6.3). 4.5.3 Bridge circuit resistance. Conformance with the bridge circuit resistance of 3.8.1 shall be ascertained on all completely as
39、sembled cartridges by means of a test circuit which limits the bridge circuit current to 50 milliamperes, maximum. A safety chamber with an interlock switch shall be used to protect the operator during the application of current. A suitable instrument which is known to be accurate to within 0.005 oh
40、m in the range of resistance specified shall be used to determine whether or not the requirement is being met. Units which fail to meet the requirement of 3.8.1 shall be cause for rejection. The results of bridge circuit resistance measurements shall not be affected by resistance of the test circuit
41、 and connector. 4.5.4 Bridgewire circuit continuity. After soldering the bridgewire, the unloaded shell assembly (Drawing 1861735) shall be thoroughly cleaned to remove flux and contamination. After cleaning, the bridgewire shall be flashed with an electric current using a voltage source of 6 volts
42、ac or dc to produce a visible red glow of the bridge and ensure continuity. A suitable resistor may be used to regulate the current to the bridge. Flashing is a necessary manufacturing operation and shall be conducted on each loaded assembly. Assemblies with bridgewires which fail to glow shall be c
43、ause for rejection. Any faulty assemblies may be reworked by replacement of the bridges. 4.5.5 Unloaded shell assembly leakage. Apply not less than 10 psi of air pressure internally to all unloaded shell assemblies (Drawing 1861735) which have passed the continuity test of 4.5.4 and check for leaks.
44、 All assemblies that show evidence of leakage shall be cause for rejection. 4.5.6 Radiographic inspection. All cartridges shall be radiographically examined in accordance with ASTM E 545. Cartridges having any observable imperfections in assembly shall be cause for rejection. The cartridges shall be
45、 positioned on their sides for the most revealing exposure. All cartridges shall be identified with serial numbers prior to examination. The cartridge serial numbers shall be in consecutive numerical order beginning with the number 001 in each production lot. The cartridges shall be arranged on tray
46、s or boards in consecutive numerical order, and each radiograph shall carry a permanent identification of the cartridges displayed thereon. The radiograph identification shall include the complete lot number, as stamped on the cartridges, and the span of serial numbers displayed. Discontinuities in
47、serial numbers shall be identified on the N-ray. Defective cartridges found by the vendor shall be clearly identified on the N-ray and those defectives removed from the production lot. The serial numbers shall be pen or ink stamped on the cartridge with approximately 1/8-inch-high characters. The se
48、rial numbers shall be located apart from the other cartridge markings. 4.5.6.1 Sample radiographic plate. A sample radiographic plate and technique shall be submitted for n-ray by the contractor for approval prior to submitting radiographs for the production lot. The production lot radiographs shall
49、 be made using the identical technique utilized to produce the approved sample plate. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-22244F (OS) 7 4.5.6.2 N-ray examination. Each cartridge shall be n-rayed in accordance with ASTM E 545, to confirm the presence of the propellant, non-metal parts, no foreign hydrogenous material and proper assemby of py