1、 INCH-POUND MIL-DTL-24643/12F 1 October 2009 SUPERSEDING MIL-DTL-24643/12E 22 August 2002 DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, -20 C TO +90 C, 300 VOLTS, TYPE LSTTOP This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acq
2、uiring the product described herein shall consist of this specification sheet and MIL-DTL-24643. Construction, Non-Watertight First - Copper conductor, coated or uncoated, 20 AWG, Class K stranding. Second - Separator may be used at manufacturers option where required to provide free-stripping insul
3、ation. Third - Thermoset insulation. Minimum average wall thickness of 0.020 inch. Telephone identification code applied by Method 3. Fourth - Two conductors shall be cabled together to form pair. The length of lay shall be determined to permit a completed cable to meet the twisting and bending endu
4、rance tests. Fifth - The specified number of pairs (see table I) shall be cabled together in one or more layers, with the minimum amount of fillers necessary to obtain a firm well-rounded assembly. Cabling sequence to be consecutive, starting with no. 1, from the center outward. The length of lay sh
5、all be determined to permit a completed cable to meet the twisting and bending endurance tests. A single pair shall not be used as center for the cable core. Outer layer shall be left-hand. Inner layer(s) direction of lay shall be at the manufacturers option. Sixth - An optional binder. Seventh - Cr
6、oss-linked polyolefin jacket. Minimum average wall thickness of 0.060 inch. AMSC N/A FSC 6145 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-24643/12F TABLE I. Details. Military part no. M24643/12 Type and size Number of pairs Overall diamet
7、er max. (inches) Roller diameter max. (inches) -01UN LSTTOP-3 3 0.480 1.4 -02UN LSTTOP-5 5 0.590 1.8 -03UN LSTTOP-10 10 0.700 2.1 -04UN LSTTOP-15 15 0.830 3.0 REQUIREMENTS: Qualification required. INSPECTION: Basic Electricals: Conductor resistance (ohms/1000 feet at 25 C, max.) 11.53 Voltage withst
8、and (volts, root mean square, min.) Conductor to conductor 2000 Insulation resistance (megohms/1000 feet, min.) Conductor to conductor 100 Conductor continuity No failure Group A: Visual and dimensional No failure Group B: Thermoset proof test (percent, max.) Insulation 50 Jacket (when tested at 200
9、 C) 50 Twisting and bending endurance (see table I for roller sizes) At 75 C (cycles, min.) 6000 At minus 302 C (cycles, min.) 2000 Physicals (unaged) Insulation (extruded) Tensile strength (lb/in2, min.) 700 Elongation (percent, min.) 150 Jacket (cable) Tensile strength (lb/in2, min.) 1300 Elongati
10、on (percent, min.) 160 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-24643/12F Tear (lb/in thickness, min.) 35 Group C: Physicals (aged) air oven Insulation (extruded) Tensile strength (percent of unaged, min.) 75 Elongation (percent of u
11、naged, min.) 75 Jacket (cable) Tensile strength (percent of unaged, min.) 60 Elongation (percent of unaged, min.) 60 Permanence of printing (jacket) (cycles, min.) 125 Heat distortion (percent of unaged, max.) 30 Group D: Flame propagation (cable) No failure Qualification Inspection: Qualification i
12、nspection shall include basic electricals; groups A, B, C, and D; plus the following: Aging and compatibility (cable) (1255 C) No failure Abrasion resistance (jacket) (scrapes, min.) 75 Acid gas equivalent (percent, max.) Jacket 2 Fillers 2 Insulation 18Halogen content (percent, max.) Jacket 0.2 Fil
13、lers 0.2Insulation 0.2 Immersion (jacket) Tensile strength (percent of unaged, min.) 50 Elongation (percent of unaged, min.) 50 Smoke index (max.) Jacket 25 Fillers 45Insulation 45 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-24643/12F 4
14、 Toxicity index (max.) Jacket 5 Fillers 5 Insulation 1.5Durometer (jacket) - Type A (hardness, min.) 80 Weathering (jacket) No failure Electrical moisture absorption No failure UNIT ORDERING LENGTHS: Type and size Feet (nominal) LSTTOP-3, 5, and 10 2500 LSTTOP-15 1500 CHANGES FROM PREVIOUS ISSUE: Ma
15、rginal notations are not used in this revision to identify changes with respect to the previous issue due to the extent of the changes. Custodians: Preparing Activity: Army MI Navy SH Navy SH (Project 6145-2008-016) Review Activities: Army AR, AV, CR Navy CG, EC DLA CC NOTE: The activities listed ab
16、ove were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at http:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-