1、MIL-R-85895 (LI LO 9999906 0469249 9 I I NCH-POUND AMENDMENT 1 18 March 1991 MIL-R-85895(AS) MILITARY SPECIFICATION RACK, BOMB EJECTOR, AIRCRAFT BRU-32lA This amendment forms a part of MIL-R-85895(AS, dated 28 March 1988, and is approved for use by the Naval Air Systems Command, Department of the Na
2、vy, and is available for use by all Departments and Agencies of the Department of Defense. PAGE 1 In beneficial comments, fifth line, delete “93“ and substitute “53.“ PAGE 2 2.1.1, in “Specification and standards,“ last line, after “solicitation,“ add “(see 6.2.11.“ 2.1 . 1 , under “SPECIFICATIONS ,
3、I add “MIL-6-5087 Bonding, Electrical, and Lightning Protection, for Aerospace Sy s t ems I delete “MIL-A-85836 Armi ng Unit, Zero Retention Force“ 2.1.1, under “STANDARDS,“ delete “MIL-STD-143“ and substi tute “MIL-STD-970“ and delete “MIL-STD-794“ and its title and substi tute “MIL-STD-2073-1 DOD
4、Materiel Procedures for Development and Application of Packaging Requirements“ PAGE 3 2.1 .l , under “STANDARDS ,II delete “MS-3314“ and substitute “MS3314“ and delete “MIL-6-5087“ and its title. 2.1 .l , below “MS3314“ add “(Un1 ess otherwi se indicated, Copi es of federal and military specificatio
5、ns, standards, and handbooks are available from the Standardization Documents Order Desk, Building 4D, 700 Robbins Avenue, Phi 1 adel phi a, PA 191 1 1 -5094. “ Delete “2.1.2 Drawings“ and its sentence and substitute “2.1.2 Other Government documents, drawings, and publications. The following other
6、Government documents, drawings, and publications form a part of this document to the extent specified herein. Unless otherwise specified, the issues are those cited in the solicitation.“ 2.1 -2, above “Naval Air Sys tems Command, II add “DRAWINGS. II 2.1.2, under “Naval Air Systems Command“, add: I
7、“1534AS251 Fi 1 ter Assembly, Low Pass-EM1 1534AS462 Armi ng Unit, Zero Retention Force“ AMSC NIA 1 of 5 FSC 1095 DISTRIBUTION STATEMENT A. Approved for pub1 ic release; distribution is un1 imi ted. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- MI
8、L-R-85895 (LI LO 9999906 O469250 5 9 MIL-R-85895(AS) AMENDMENT 1 2.1.2, below “1534AS462“ delete in its entirety “(copies of specifications, standards, and drawings in connection - activity.)“ and substitute (Code 3121, 700 Robbins Avenue, Philadelphia, PA 19111-5097.)“ “(Copies are available from t
9、he Naval Air Technical Services Facility (NATSF) 3.1, delete its sentence in its entirety and substitute “When specified (see 6.2.1), a sample shall be subjected to first article inspection (see 6.3.1) in accordance with 4.3.“ 3.2, last line, delete “MIL-STD-143“ and substitute “MIL-STD-970.“ PAGE 5
10、 3.6.3, second 1 ine, delete “MIL-A-85836“ and substi tute “NAVAIR Drawing 1534AS462.“ 4.1, third line, after “requirements,“ add “(examinations and test).“ 4.1, fifth line, delete “facility“ and substitute “facilities.“ 4.1, eighth 1 ine, delete “tests“ and substi tute “inspections.“ 4.1, ninth lin
11、e, delete “assure II and substitute “ensure.“ 4.1 .l, first line, delete “must“ and substitute “shall.“ 4.1 .l, sixth line, delete “assuring“ and substitute “ensuring.“ 4.1.1, eighth line, delete “Sampling in quality conformance“ and substitute “Sampling inspection, as part of manufacturing operatio
12、ns, is an acceptable practice to ascertain conformance to requirements, however, this.“ PAGE 6 4.4, last line, delete “(see 6.3)“ and substitute “(see 6.2.2).“ 4.4.2, fourth and fifth lines, delete second sentence, “These samples shall be identified as A, B, C, D.“ PAGE 7 4.5d(4, first 1 ine, delete
13、 “2,600“ and substi tute “2,400.“ PAGE 9 4.6.2k, first 1 ine, delete “2,000“ and substi tute “2,400.“ 4.6.21, second 1 ine, delete “2,000“ and substi tute “2,400.“ 4.6.3, fourth and sixth lines, delete “300“ and substitute “600.“ 2 Provided by IHSNot for ResaleNo reproduction or networking permitted
14、 without license from IHS-,-,-MIL-R-85895 (1) 10 m 9999906 0469253 7 m MIL-R-85895(AS AMENDMENT 1 PAGE 10 4.6.5.3, second line, after “MIL-STD-461,“ add “as modified by NAVAIR Drawing 1534AS251 . II 4.6.5.6, third line, delete “2,600“ and substitute “2,400.“ 4.6.5.7, second 1 ine, before “Procedure
15、II“ add “MIL-T-7743.“ PAGE 11 4.6.5.10b, second line, delete “2,600“ and substitute “2,400.“ 4.6.5.11, last line, delete “2,600“ and substitute “2,400.“ 4.6.5.15a, first line, delete “2,600“ and substitute “2,400.“ PAGE 12 5.1, second 1 ine, delete “MIL-STD-794“ and substi tute “MIL-STD-2073-1 .II 5
16、.2 and 5.3, last line, delete “MIL-STD-794“ and substitute “MIL-STD-2073-1 .II Under “6. NOTES“ add “(This section contains information of a general or explanatory nature that may be helpful, but is not mandatory.)“ PAGE 13 6.2.1, under 1“ add specif i c issue of i ndi vi dual documents referenced (
17、see 2.1.1). II “m. When first article is required (see 3.1 and 6.3.1). n Issue of DODISS to be cited in the solicitation, and if required, the Delete 6.2.2 in its entirety and substitute “6.2.2 Consideration of dGa requirements. The following data requirements should be considered when this specific
18、ation is amlied on a contract. The amlicable Data Item Descriptions (DIDS) should be reviewed in conjunction with the specific acquisition to ensure that only essential data are requested/provided and that the DIDS are tailored to reflect the requirements of the specific acquisition. ensure correct
19、contractural application of the data requirements, a Contract Data Requirements List (DD Form 1423) must be prepared to obtain the data, except where DOD FAR Supplement 27.475-1 exempts the requirement for a DD Form 1423. Ref er e nce Suggested Paragraph DID Number DID Title Tai lor i np To 4.3, 4.4
20、 DI-T-2072 Reports, test - The above DIDS were those cleared as of the date of this specification. c,urrent issue of DOD 5010.12-L, Acquisition Management Systems and Data Requirements Cbntrol List (AMSDL), must be researched to ensure that only current, cleared DIDS are cited on the DD Form 1423.“
21、6.3.1, second line, delete “6.2“ and substitute “6.2.1 .I The 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-R-5875 (LI LO 9997906 0469252 7 MIL-R-85895(AS AMENDMENT 1 PAGE 14 Delete existing 6.5 in its entirety and substitute “6.5 Subject ter
22、m (key word) listing. Fuel tanks, multiple carriage Multiple carriage Single carriage, 14 and 30 inch suspension stores Stores, 500 to 2,600 pounds“ PAGE 15 Delete existing table I in its entirety and substitute as shown “TABLE I. First article inspections - schedule and sequence. ll Tests Bomb rack
23、 inspection Functional test Arming unit Electric fuze arming Manual operation Electrical characteristics Electromagnetic compatibility Lag time determination Icing Shock Vi bration Sand Temperature shock Hi gh-g Li fe Stress corrosion Humi di ty Fungus Lock shut firing Static test Salt spraylal ti t
24、ude Test paragraph 4.6.1 4.6.2 4.6.3 4.6.4 4.6.5.1 4.6.5.2 4.6.5.3 4.6.5.4 4.6.5.5 4.6.5.6 4.6.5.7 4.6.5.8 4.6.5.9 4.6.5.10 4.6.5.11 4.6.5.12 4.6.5.13 4.6.5.14 4.6.5.15 4.6.5.16 4.6.5.17 - 1l Inspection sequence is denoted by the numbers in An X denotes test is not required.“ Samp 1 e A 6 1 1 2 2 3
25、3 4 4 5 X 6 5 7 X 8 X 9 X X 6 X 7 10 X X 8 11 X 12 X 13 X X 9 X 10 14 X X 11 X 12 the sample columns 4 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-R-85895(AS) AMENDMENT 1 PAGE 19 Delete existing table V in its entirety and substitute table V
26、as shown “TABLE V. Static test limit loads. Simulated store characteristics Longitudinal dimension Vertical dimension Store Lug center aft of lug I/ from top of store L/ A 30 inch 15.0 inch 1.0 inch B 30 inch 15.0 inch 16.125 inch C 30 inch 11.93 inch 10.35 inch Combined limit loads and moments abou
27、t reference points (store c.g.1 21 PZ PY Px MZZ Myy Mxx vert- longi- Yaw pitch roll -,Condition Store ical side tudinal moment moment moment 1 A -15,400 1 T ,533 1,833 4,400 38,133 178,133 2 B -13,818 11,515 -13,818 -21,081 76,350 12,420 3 C -13,380 11,500 -20,700 -29,052 121,050 1,890 I Sign conven
28、tion I tPx = Longitudinal aft tMxx = Roll clockwise looking forward tPy = Side to port tMyy = Pitch nose up tPz = Vertical up tMzz = Yaw nose to port - 1/ The centroid of the loads shall act at a point in accordance with these dimensions. - 2/ All loads are in pounds. All moments are in inch-pounds.“ Preparing activity: Navy - AS (Project 1095-N257) 5 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-