1、METRICMIL-STD-2042-2B(SH)25 July 2002SUPERSEDINGMIL-STD-2042-2A(SH)29 September 1997MIL-STD-2042-2(SH)7 July 1993DEPARTMENT OF DEFENSESTANDARD PRACTICEFIBER OPTIC CABLE TOPOLOGY INSTALLATIONSTANDARD METHODS FOR NAVAL SHIPS(EQUIPMENT)(PART 2 OF 7 PARTS)AMSC N/A AREA GDRQDISTRIBUTION STATEMENT A. Appr
2、oved for public release; distribution is unlimited.Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-STD-2042-2B(SH)iiFOREWORD1. This Department of Defense Standard Practice is approved for use by theNaval Sea Systems Command, Department of the Nav
3、y, and is available for use by allDepartments and Agencies of the Department of Defense.2. Beneficial comments (recommendations, additions, deletions) and anypertinent data which may be of use in improving this document should be addressedto: Department of the Navy, Naval Sea Systems Command, ATTN:
4、SEA 05Q, 1333 IsaacHull Avenue Southeast, Stop 5160, Washington Navy Yard, DC 20376-5160 by using theself-addressed Standardization Document Improvement Proposal (DD Form 1426)appearing at the end of this document or by letter.3. This standard practice provides detailed information and guidance tope
5、rsonnel concerned with the installation of fiber optic cable topologies (opticalfiber cabling and associated components) on Naval surface ships and submarines. Themethods specified herein are not identifiable to any specific ship class or type,but are intended to standardize and minimize variations
6、in installations to enhancethe compatibility of the installations on all Naval ships.4. In order to provide flexibility in the use and update of the installationmethods, this standard practice is issued in eight parts; the basic standardpractice and seven numbered parts as follows:Part 1 CablesPart
7、2 EquipmentPart 3 Cable PenetrationsPart 4 CablewaysPart 5 Connectors and InterconnectionsPart 6 TestsPart 7 Pierside Connectivity Cable Assemblies and Interconnection HardwareProvided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-STD-2042-2B(SH)iiiCONT
8、ENTSPARAGRAPH PAGE1. SCOPE . 11.1 Scope . 11.1.1 Applicability . 12. APPLICABLE DOCUMENTS 22.1 General . 22.2 Government documents 22.2.1 Specifications, standards and handbooks . 22.2.2 Other government documents 32.3 Non-Government publications . 32.4 Order of precedence . 43. DEFINITIONS . 53.1 G
9、eneral fiber optics terms 53.2 Acronyms 53.3 Allocated and not used fiber 53.4 Allocated and used fiber 53.5 Alternate channel . 53.6 Authorized approval . 53.7 BOF bundle 53.8 BOF cable . 53.9 BOF fiber . 53.10 BOF path 53.11 BOF tube 53.12 BOF tube coupler 53.13 BOF tube routing box (TRB) 53.14 En
10、d user equipment 53.15 Fiber optic cable plant . 53.16 Fiber optic cable topology 63.17 Fiber optic interconnection box (FOICB) . 63.18 Installing activity . 63.19 Local cable . 63.20 Minimum bend diameter . 63.21 Multicable penetrator (MCP) . 63.22 Non-redundant channel (NRC) . 63.23 Normal channel
11、 63.24 Optical fiber cable . 63.25 Optical fiber cable component (OFCC). . 63.26 Outlet box 63.27 Spare fiber . 63.28 Trunk . 73.29 Trunk cable . 73.30 Tube furcation unit . 73.31 Unused fiber 74. GENERAL REQUIREMENTS 84.1 Fiber optic equipment installation 84.1.1 Interconnection box and tube routin
12、g box selection 84.1.2 Location 84.1.3 Interconnection box mounting 84.1.3.1 Bonding, grounding, and shielding . 84.1.3.2 Holes drilled in beams 94.1.3.3 Welding . 94.1.3.4 Fasteners . 94.1.3.5 Dissimilar metals . 9Provided by IHSNot for ResaleNo reproduction or networking permitted without license
13、from IHS-,-,-MIL-STD-2042-2B(SH)ivCONTENTSPARAGRAPH PAGE4.2 Cable entrance to equipment . 94.2.1 Cable slack . 94.2.2 Cable forming and shaping 104.2.3 Tube forming and shaping . 104.2.4 Splice assembly and alignment 104.2.5 Interconnection organization . 104.2.5.1 Connector organization . 104.2.6 N
14、ameplates and marking . 114.2.6.1 Internal interconnection box marking . 114.2.6.2 Internal tube routing box marking 114.2.7 BOF tube end termination . 114.3 Safety precautions . 125. DETAILED REQUIREMENTS 135.1 Fiber optic interconnection equipment installation . 135.1.1 Non-watertight decks and bu
15、lkheads . 135.1.2 Watertight decks and bulkheads . 135.1.3 Stanchions . 135.1.4 Metal joiner bulkheads . 135.1.5 Expanded metal or wire mesh bulkhead . 135.1.6 Refrigerated spaces 135.1.7 GRP (glass reinforced plastic) bulkheads . 135.1.8 Locking devices for installations on submarines 145.2 Cable e
16、ntrance to equipment 145.2.1 Nylon stuffing tubes . 145.2.2 Multiple cable penetrator (MCP) 145.2.3 Cable clamps . 145.3 Interconnection organization . 145.3.1 Conventional cable . 145.3.2 BOF cable 145.4 Splice assembly and alignment 145.5 BOF tube furcation unit fabrication 145.6 BOF tube furcatio
17、n unit installation . 145.7 BOF tube end sealing . 146. NOTES 156.1 Intended use . 156.2 Issue of DODISS 156.3 Standard method designation 156.4 Subject term (key word) listing 15METHOD2A1 Conventional cable entrance to equipment via nylon stuffing tubes . 2A1-12B1 Conventional cable entrance to equ
18、ipment via MCP 2B1-12C1 Conventional cable and buffered fiber forming and shaping . 2C1-12D1 Splice assembly and alignment . 2D1-12E1 BOF tube furcation unit fabrication . 2E1-12F1 BOF tube furcation unit installation 2F1-12G1 BOF cable entrance to equipment via nylon stuffing tubes 2G1-12H1 BOF cab
19、le entrance to equipment via MCP . 2H1-12I1 BOF cable forming, routing, and shaping within tube routing boxes . 2I1-1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-STD-2042-2B(SH)vCONTENTSMETHOD PAGE2I2 BOF cable forming, routing, and shaping wi
20、thininterconnection boxes . 2I2-12J1 BOF tube end sealing 2J1-1TABLE2A1-I Equipment and materials. 2A1-12A1-II Nylon stuffing tube sizes for optical fiber cable. 2A1-22A1-III Nylon stuffing tube data 2A1-22B1-I Equipment and materials. 2B1-12B1-II MCP data and insert block sizes for optical fiber ca
21、bles 2B1-22C1-I Equipment and materials . 2C1-12D1-I Equipment and materials. 2D1-12E1-I Equipment and materials . 2E1-12F1-I Equipment and materials. 2F1-12F1-II Fiber color coding. . 2F1-82G1-I Equipment and materials . 2G1-12G1-II Nylon stuffing tube sizes for BOF cable. 2G1-22G1-III Nylon stuffi
22、ng tube data 2G1-22H1-I Equipment and materials. 2H1-12H1-II MCP data and insert block sizes for BOF cables 2H1-22I1-I Equipment and materials. 2I1-12I2-I Equipment and materials . 2I2-12J1-I Equipment and materials. 2J1-1FIGURE2-1 Example patch panel configuration . 112A1-1 Straight tube 2A1-32A1-2
23、 “Y“ (45o) tube 2A1-42A1-3 90oangle tube. 2A1-42A1-4 NPT tube 2A1-52B1-1 Interconnection box integral MCP-(typical) 2B1-32C1-1 Forming and shaping - (typical) . 2C1-32C1-2 Compressing ferrule springs . 2C1-52C1-3 Splices installed in splice tray - (typical) 2C1-52D1-1 Opening alignment sleeve 2D1-22
24、D1-2 Inserting ferrule into alignment sleeve . 2D1-32D1-3 Inserting second ferrule into alignment sleeve 2D1-32D1-4 Aligning tabs . 2D1-42D1-5 Active splice alignment cable hookup 2D1-42E1-1 Aligning the loose tube furcation cables 2E1-32E1-2 Folding back the kevlar . 2E1-32E1-3 Furcation cables joi
25、ned to the BOF tube . 2E1-42E1-4 Completed assembly 2E1-52F1-1 Short BOF tube and fibers . 2F1-42F1-2 Short BOF tube and fibers . 2F1-62F1-3 BOF tube and fibers . 2F1-72F1-4 Feeding fibers into the furcation unit 2F1-72F1-5 Installed furcation unit 2F1-82G1-1 Straight tube . 2G1-32G1-2 “Y“ (45o) tub
26、e. 2G1-32G1-3 90oangle tube. 2G1-42G1-4 NPT tube 2G1-4Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-STD-2042-2B(SH)viCONTENTSFIGURE PAGE2H1-1 Interconnection box integral MCP typical 2H1-22I1-1 Routing BOF tubes in TRB 2I1-22I1-2 Typical jumper
27、 tube paths . 2I1-42I2-1 Routing BOF tubes in a FOICB 2I1-3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-STD-2042-2B(SH)11. SCOPE1.1 Scope. This standard provides detailed methods for the installation offiber optic cable topology equipment (see
28、 3.16), and optical fiber cable entry tofiber optic cable topology and other equipment.1.1.1 Applicability. These criteria apply to installations on specific shipswhen invoked by the governing ship specification or other contractual document.They are intended primarily for new construction; however,
29、 they are also applicablefor conversion or alteration of existing ships. The rapidly changing state of theart in fiber optic technology makes it essential that some degree of flexibility beexercised in enforcing this document. When there is a conflict between thisdocument and the ship specification
30、or contract, the ship specification or contractshall take precedence. Where ship design is such that the methods herein cannot beimplemented, users shall submit new methods or modifications of existing methods forapproval prior to implementation to: Department of the Navy, Naval Surface WarfareCente
31、r, Dahlgren Division, ATTN: Code B35, 17320 Dahlgren Road, Dahlgren, VA 22448-5100.Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-STD-2042-2B(SH)22. APPLICABLE DOCUMENTS2.1 General. The documents listed in this section are specified in sections3
32、, 4 and 5 of this standard practice. This section does not include documents citedin other sections of this standard practice or recommended for additionalinformation or as examples. While every effort has been made to ensure thecompleteness of this list, document users are cautioned that they must
33、meet allspecified requirements documents cited in sections 3, 4 and 5 of this standardpractice, whether or not they are listed.2.2 Government documents.2.2.1 Specifications, standards and handbooks. The following specifications,standards, and handbooks form a part of this document to the extent spec
34、ifiedherein. Unless otherwise specified, the issues of these documents are those listedin the issue of the Department of Defense Index of Specifications and Standards(DODISS) and supplement thereto, cited in the solicitation (see 6.2).FEDERAL SPECIFICATIONSA-A-00272 - Caulking Compounds.A-A-59728 -
35、Plug, Tube Fitting, Blown Optical Fiber.A-A-59729 - Furcation Units, Tube, Blown Optical Fiber.A-A-59730 - Plugs, Tapered Tube, Blown Optical Fiber.A-A-59731 - Fittings, Tube, Blown Optical Fiber.DEPARTMENT OF DEFENSE SPECIFICATIONSMIL-DTL-15024 - Plates, Tags and Bands for Identification ofEquipmen
36、t.MIL-DTL-15024/5 - Plate, Identification.MIL-E-24142 - Enclosures for Electrical Fittings and Fixtures,General Specification For.MIL-S-24235 - Stuffing Tubes, Metal and Packing Assemblies forElectric Cables, General Specification for.MIL-PRF-24623 - Splice, Fiber Optic Cable, General Specification
37、for(Metric).MIL-PRF-24623/4 - Splice, Fiber Optic, Housing, Fiber.MIL-I-24728 - Interconnection Box, Fiber Optic, Metric, GeneralSpecification for.DEPARTMENT OF DEFENSE STANDARDSMIL-STD-461 - Electromagnetic Emission and SusceptibilityRequirements for the Control of ElectromagneticInterference.MIL-S
38、TD-889 - Dissimilar Metals.MIL-STD-1310 - Shipboard Bonding, Grounding, and other Techniquesfor Electromagnetic Compatibility and Safety.MIL-STD-2003 - Electric Plant Installation Standard Methods forSurface Ships and Submarines.Provided by IHSNot for ResaleNo reproduction or networking permitted wi
39、thout license from IHS-,-,-MIL-STD-2042-2B(SH)3MIL-STD-2003-1 - Electric Plant Installation Standard Methods forSurface Ships and Submarines (Cable).MIL-STD-2003-2 - Electric Plant Installation Standard Methods forSurface Ships and Submarines (Equipment).MIL-STD-2042-1 - Fiber Optic Topology Install
40、ation Standard Methodsfor Naval Ships (Cables)(Part 1 of 7 Parts).MIL-STD-2042-5 - Fiber Optic Topology Installation Standard Methodsfor Naval Ships (Connections andInterconnections)(Part 5 of 7 Parts).MIL-STD-2042-6 - Fiber Optic Topology Installation Standard Methodsfor Naval Ships (Tests)(Part 6
41、of 7 Parts).(Unless otherwise indicated, copies of the above specifications, standards, andhandbooks are available from the Standardization Documents Order Desk, 700 RobbinsAve, Building 4D, Philadelphia, PA, 19111-5094.)2.2.2 Other Government documents. The following other Government documentsform
42、a part of this document to the extent specified herein. Unless otherwisespecified, the issues are those cited in the solicitation.DEPARTMENT OF DEFENSE DRAWINGSNAVSEA Drawing - 6872812 Tool Kit, MIL-S-24623, Fiber Optic, NavyShipboard.NAVSEA TECHNICAL PUBLICATIONSS9074-AR-GIB-010/278 - Welding and C
43、asting.(Copies of documents should be obtained from the contracting activity or asdirected by the contracting officer.)2.3 Non-Government publications. The following documents form a part of thisdocument to the extent specified herein. Unless otherwise specified, the issues ofthe documents which are
44、 DOD adopted are those listed in the issue of the DODISScited in the solicitation. Unless otherwise specified, the issues of documents notlisted in the DODISS are the issues of the documents cited in the solicitation (see6.2).AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI)ANSI Z136.2 - Safe Use of Opti
45、cal Fiber Communication SystemsUtilizing Laser Diode and LED Sources(Application for copies should be addressed to the American National StandardsInstitute, 1430 Broadway, New York, NY 10018-3308.)AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM)ASTM F1836M - Standard Specification for Stuffing Tube
46、s, Nylon,and Packing Assemblies (Metric)(Application for copies should be addressed to the American Society for Testingand Materials, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959.)Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-STD-204
47、2-2B(SH)4ELECTRONICS INDUSTRY ASSOCIATION/TELECOMMUNICATIONS INDUSTRY ASSOCIATIONEIA/TIA-440 - Fiber Optic Terminology.(Application for copies should be addressed to Global Engineering Documents,1990 M Street NW, Suite 400, Washington, DC 20036.)SOCIETY OF AUTOMOTIVE ENGINEERS (SAE)SAE AMS-DTL-23053
48、/5 - Insulation Sleeving, Electrical, HeatShrinkable, Polyolefin, Flexible, Crosslinked.SAE AS 23190 - Straps, Clamps and Mounting Hardware, Plasticand Metal for Cable Harness Tying and Support.(Application for copies should be addressed to Society of Automotive Engineers,400 Commonwealth Drive, War
49、rendale, PA 15096-0001)2.4 Order of precedence. In the event of a conflict between the text of thisdocument and the references cited herein, the text of this document takesprecedence. Nothing in this document, however, supersedes applicable laws andregulations unless a specific exemption has been obtained.Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-
copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1