1、I . MIL-T-82049C (2) 73 = 777770b 0242671 7 c-73- 67 MIL-T-82049C AMENDMENT 2 30 November 1988 SUPERSEDING . MIL-T-82049C AMENDMENT 1 (- 18 November 1987 MILITARY s PEC I FI CAT ION TABLES, HOT FOOD, ELECTRIC, MOBILE This amendment forms a part of Military Specification MIL-T-82049C, dated 19 April
2、1984, and is approved for use by all Departments and Agencies of the Department of Defense. PAGE 1 ADD “1.3 Definitive specification part number. The specification part number is definitive to identify each item covered by selecting from the options available (see 1.2). designated as follows: The pa
3、rt number is formatted and X - X M82049 - Military specification number I I I I /- Type designator .I I Size designator l i .-. I I I I Option type I Desiqnator I I I 1 l I I II (With Drain) I 2 I I Size I 1 I 3 I 4 I 5 I I I I I I (Without Drain) I 3 I 4 I 5 I I i 6 6 i Example: A size 4 mobile hot
4、 food table without a drain is designated, M82049-1-4. # AMSC N/A FSC 7310 Approved for public release; distribution is 1 of 3 I k DISTRIBUTION STATEMENT A. unlimited. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- k - MIL-T-2097C (2) 73 m 9799906
5、0292692 7 m PAGE 5 3.7.l;delete second sentence in its entirety. 3.7.4, in the second sentence delete the word “deep“ and substitute 8idrop.11 3.7.5, delete second sentence in its entirety and substitute: “Heating compartments shall be fabricated of corrosionyesistant steel conforming to ASTM, class
6、 302 or 304, having a minimum thickness of 0.050 inches.“ PAGE 6 3.7.5, delete fifth sentence in its entirety and substitute: “The top edge of the compartment shall be fabricated in accordance with FIGURE 1 .I Delete seventh sentence in its entirety and substitute: “The heating compartments shall co
7、nform to MIL-W-43896 and NSF No. 2 or 4.l 3.7.6, delete fourth and fifth sentences in their entirety and substitute: “Electrical input power shall either be 208 to 240 volt (V) 60 Hertz (Hz), or 480V, 60 Hz and provide for either single or three phase alternating current, as specified (see 6.2).“ PA
8、GE 7 3.7.8.1, in the next to last sentence delete the word “trail“ and s u b s t i tut e I t ray. It 3.7.8.1, add the following to the end of the paragraph: “The tray rails shall be capable of supporting the weights listed below dlstrlbuted uniformally over their full length with no evidence of defo
9、rmation when tested as specified In 4.6.5: Size 3 - 75 pounds (lbs) Size 4 - 100 lbs Size 5 - 125 lbs Size 6 - 150 lbs . 20f3 -3- - - -. - Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-PAGE 8 3.7.9, delete third sentence in its entirety and substit
10、ute: “The sides of the shelf inside the end panels shall be turned and fastened to the top per the manufacturers standard procedure; the juncture of the sides and back thus formed shall be welded.“ PAGE 13 Add “4.6.5 Tray rail weight bearing test. One unit shall be selected at random from each lot a
11、nd tested for the tray rail weight bearing requirement of 3.7.8.1. The required weight for the size being tested shall be equally distributed over the full length of the tray rail for a full ten minutes before being removed. Any evidence of bending, distortion, deflection, or other deformation of th
12、e tray rail after removal of the weight shall be cause for rejection of the lot.“ Custodians: Army - GL Navy - YD Air Force - 99 Review activities: Navy - MS, SA Amy - CE, MD i Air Force - 84 DLA - GS .- User activity: Air Force - 03 Prepari ng activity : Navy - YD (Project 7310-0756) I 3 of 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-
copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有