1、QPL-22122013-12-06QUALIFIED PRODUCT LISTOFPRODUCTS QUALIFIED UNDER PERFORMANCE SPECIFICATIONMIL-DTL-2212Contactors and Controllers, Electric Motor AC or DC, and Associated Switching DevicesThis list has been prepared for use by or for the Government in the acquisition of products covered by the subj
2、ect specification and such listing of a product is not intended to and does not connote endorsement of the product by the Department of Defense. All products listed herein have been qualified under the requirements for the product as specified in the latest effective issue of the applicable specific
3、ation. This list is subject to change without notice; revision or amendment of this list will be issued as necessary. The listing of a product does not release the contractor from compliance with the specification requirements.The activity responsible for this QPL is Naval Sea Systems Command, 1333
4、Isaac Hull Ave. SE, Washington Navy Yard, DC 20376-5160 or email commandstandardsnavy.mil.GOVERNMENT DESIGNATION MANUFACTURER DESIGNATION TEST REFERENCE CAGE CODESupplier TypeCertified StatusStop ShipCONTROLLERS: AC MAGNETICRATING: SIZE 2/2, 440 VAC, 60 HZ, 3-PHASE ENCLOSURE: DPMASTER PLAN 27280, SI
5、ZE 2/2, DUAL SPEED, NON-REVERSING, AC MAGNETIC CONTROLLER W/N302 ELECTRONIC OVERLOAD RELAY (DWG. 27282 REV. B)Ward Leonard Test Report No. 13-12181 dated 2/01/13; NSWCCD-SSES Ltr to NAVSEA 05Z Ser 939/007 dated 1/25/1363743 M Green Until: 19-APR-15NCONTROLLERS: AC MAGNETICRATING: SIZE 2/2, 440 VAC,
6、60 HZ, 3-PHASE ENCLOSURE: DPMASTER PLAN 27280, SIZE 2/2, DUAL SPEED, NON-REVERSING, AC MAGNETIC CONTROLLER W/N302 ELECTRONIC OVERLOAD RELAY (DWG. 27282 REV. B)63743 P Green Until: 19-APR-15NRELAYS: CONTROLCONTACT RATING: 450 VAC, 6 AMPS 120 VAC, 15 AMPSCONTACTS: MAX 4 NO/ 4 NCTYPE N430 Ward Leonard
7、Test Report No. 11-1210163743 M Green Until: 05-APR-14NRELAYS: CONTROLCONTACT RATING: 450 VAC, 6 AMPS 120 VAC, 15 AMPSCONTACTS: MAX 4 NO/ 4 NCTYPE N430 63743 P Green Until: 05-APR-14NCONTACTORS: AC, ENCLOSEDRATING: SIZE 5, 200HP, 440V, 270 AMPSTYPE 6956 (APPROVED BY EXTENSION)DRS Test Report No. MC-
8、02061227192 M Green Until: 01-MAR-14NCONTACTORS: AC, ENCLOSEDRATING: SIZE 5, 200HP, 440V, 270 AMPSTYPE 6956 (APPROVED BY EXTENSION)27192 P Green Until: 01-MAR-14NSWITCHES: PRESSURE AND TEMPERATUREENCLOSURE:CONTACT RATING:115V, 16.0 AMPS AC;440V, 4.2 AMPS AC;115V, 9.6 AMPS DC;230V, 4.8 AMPS DC;250V (
9、NOMINAL), 3.1 AMPS DC(210V TO 355V)SERIES 222-20 Test Bulletin No. 16a 19278 M Green Until: 10-SEP-15NQPL-22121 of 27Source: QPD at https:/assist.daps.dla.mil - QPL Date: 2013-12-06If past the certification date, contact Qualifying Activity for status.Provided by IHSNot for ResaleNo reproduction or
10、networking permitted without license from IHS-,-,-GOVERNMENT DESIGNATION MANUFACTURER DESIGNATION TEST REFERENCE CAGE CODESupplier TypeCertified StatusStop ShipSWITCHES: PRESSURE AND TEMPERATUREENCLOSURE:CONTACT RATING:115V, 16.0 AMPS AC;440V, 4.2 AMPS AC;115V, 9.6 AMPS DC;230V, 4.8 AMPS DC;250V (NO
11、MINAL), 3.1 AMPS DC(210V TO 355V)SERIES 222-20 19278 P Green Until: 10-SEP-15NSWITCHES: PRESSURE AND TEMPERATUREENCLOSURE: SPLASHPROOFCONTACT RATING:115V, 16.0 AMPS AC;230V, 8.0 AMPS AC;440V, 4.0 AMPS ACSERIES 222-25 Test Bulletin No. 16a 19278 M Green Until: 10-SEP-15NSWITCHES: PRESSURE AND TEMPERA
12、TUREENCLOSURE: SPLASHPROOFCONTACT RATING:115V, 16.0 AMPS AC;230V, 8.0 AMPS AC;440V, 4.0 AMPS ACSERIES 222-25 19278 P Green Until: 10-SEP-15NSWITCHES: PRESSURE AND TEMPERATUREENCLOSURE: WATERTIGHTCONTACT RATING: 115V, 15.0 AMPS AC;230V, 8.0 AMPS AC;440V, 12.0 AMPS AC;115V, 0.5 AMPS DC;230V, 0.25 AMPS
13、 DCSERIES 444-10 Test Bulletin No. 16a 19278 M Green Until: 10-SEP-15NSWITCHES: PRESSURE AND TEMPERATUREENCLOSURE: WATERTIGHTCONTACT RATING: 115V, 15.0 AMPS AC;230V, 8.0 AMPS AC;440V, 12.0 AMPS AC;115V, 0.5 AMPS DC;230V, 0.25 AMPS DCSERIES 444-10 19278 P Green Until: 10-SEP-15NSWITCHES: PRESSURE AND
14、 TEMPERATUREENCLOSURE:CONTACT RATING:115V, 16.0 AMPS AC;440V, 4.2 AMPS AC;115V, 9.6 AMPS DC;230V, 4.8 AMPS DC;250V (NOMINAL), 3.1 AMPS DC(210V TO 355V)SERIES 222-10 Test Bulletin No. 16a 19278 M Green Until: 10-SEP-15NSWITCHES: PRESSURE AND TEMPERATUREENCLOSURE:CONTACT RATING:115V, 16.0 AMPS AC;440V
15、, 4.2 AMPS AC;115V, 9.6 AMPS DC;230V, 4.8 AMPS DC;250V (NOMINAL), 3.1 AMPS DC(210V TO 355V)SERIES 222-10 19278 P Green Until: 10-SEP-15NCONTROLLERS: ACRATING: SIZE 5/4, 115V, 60 HZ, 3-PHASEMASTER PLAN 27342 Ward Leonard Test Report No. 11-1210063743 M Green Until: 05-APR-14NCONTROLLERS: ACRATING: SI
16、ZE 5/4, 115V, 60 HZ, 3-PHASEMASTER PLAN 27342 63743 P Green Until: 05-APR-14NQPL-22122 of 27Source: QPD at https:/assist.daps.dla.mil - QPL Date: 2013-12-06If past the certification date, contact Qualifying Activity for status.Provided by IHSNot for ResaleNo reproduction or networking permitted with
17、out license from IHS-,-,-GOVERNMENT DESIGNATION MANUFACTURER DESIGNATION TEST REFERENCE CAGE CODESupplier TypeCertified StatusStop ShipCONTROLLERS: AC MAGNETICRATING: SIZE 3, 50HP, 440V, 90 AMPS TWO SPEED, NON-REVERSING, ACROSS-THE-LINETYPE: 6967ED DRS Test Report No. MC-02069727192 M Green Until: 0
18、1-MAR-14NCONTROLLERS: AC MAGNETICRATING: SIZE 3, 50HP, 440V, 90 AMPS TWO SPEED, NON-REVERSING, ACROSS-THE-LINETYPE: 6967ED 27192 P Green Until: 01-MAR-14NCONTROLLERS: AC MAGNETICRATING: SIZE 3, 50HP, 440V, 90 AMPS ONE SPEED, NON-REVERSING, ACROSS-THE-LINETYPE: 6962ED (APPROVED BY EXTENSION)DRS Test
19、Report No. MC-02069727192 M Green Until: 01-MAR-14NCONTROLLERS: AC MAGNETICRATING: SIZE 3, 50HP, 440V, 90 AMPS ONE SPEED, NON-REVERSING, ACROSS-THE-LINETYPE: 6962ED (APPROVED BY EXTENSION)27192 P Green Until: 01-MAR-14NCONTROLLERS: AC MAGNETICRATING: SIZE 3, 50HP, 440V, 90 AMPS ONE SPEED, REVERSING,
20、 ACROSS-THE-LINETYPE: 6963ED (APPROVED BY EXTENSION)DRS Test Report No. MC-02069727192 M Green Until: 01-MAR-14NCONTROLLERS: AC MAGNETICRATING: SIZE 3, 50HP, 440V, 90 AMPS ONE SPEED, REVERSING, ACROSS-THE-LINETYPE: 6963ED (APPROVED BY EXTENSION)27192 P Green Until: 01-MAR-14NCONTROLLERS: AC MAGNETIC
21、RATING: SIZE 3, 50HP, 440V, 90 AMPS TWO SPEED, REVERSING, ACROSS-THE-LINETYPE: 6968ED (APPROVED BY EXTENSION)DRS Test Report No. MC-02069727192 M Green Until: 01-MAR-14NCONTROLLERS: AC MAGNETICRATING: SIZE 3, 50HP, 440V, 90 AMPS TWO SPEED, REVERSING, ACROSS-THE-LINETYPE: 6968ED (APPROVED BY EXTENSIO
22、N)27192 P Green Until: 01-MAR-14NCONTROLLERS: AC MAGNETICRATING: SIZE 3, 50HP, 440V, 90 AMPS, ENCLOSED W/O OVERLOADTYPE: 6956ED (APPROVED BY EXTENSION)DRS Test Report No. MC-02069727192 M Green Until: 01-MAR-14NCONTROLLERS: AC MAGNETICRATING: SIZE 3, 50HP, 440V, 90 AMPS, ENCLOSED W/O OVERLOADTYPE: 6
23、956ED (APPROVED BY EXTENSION)27192 P Green Until: 01-MAR-14NSWITCHES: MASTERENCLOSURE: WATERTIGHTCONTACT RATING:440V, 5 AMPS AC 250V, 10 AMPS AC 115V, 10 AMPS AC 350V, 2 AMPS DC 250V, 5 AMPS DC 120V, 10 AMPS DC POLES: 12 MAXPOSITIONS: 2 TO 4TYPE IC5847 Ward Leonard Test Report No. 11-1210363743 M Gr
24、een Until: 05-APR-14NSWITCHES: MASTERENCLOSURE: WATERTIGHTCONTACT RATING:440V, 5 AMPS AC 250V, 10 AMPS AC 115V, 10 AMPS AC 350V, 2 AMPS DC 250V, 5 AMPS DC 120V, 10 AMPS DC POLES: 12 MAXPOSITIONS: 2 TO 4TYPE IC5847 63743 P Green Until: 05-APR-14NSWITCHES: MASTERENCLOSURE: WATERTIGHTCONTACT RATING:440
25、V, 5 AMPS AC 250V, 10 AMPS AC 115V, 10 AMPS AC 350V, 2 AMPS DC 250V, 5 AMPS DC 120V, 10 AMPS DC POLES: 12 MAXPOSITIONS: 2 TO 4TYPE IC5847C(APPROVED BY EXTENSION)Ward Leonard Test Report No. 11-1210363743 M Green Until: 05-APR-14NQPL-22123 of 27Source: QPD at https:/assist.daps.dla.mil - QPL Date: 20
26、13-12-06If past the certification date, contact Qualifying Activity for status.Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-GOVERNMENT DESIGNATION MANUFACTURER DESIGNATION TEST REFERENCE CAGE CODESupplier TypeCertified StatusStop ShipSWITCHES: MAS
27、TERENCLOSURE: WATERTIGHTCONTACT RATING:440V, 5 AMPS AC 250V, 10 AMPS AC 115V, 10 AMPS AC 350V, 2 AMPS DC 250V, 5 AMPS DC 120V, 10 AMPS DC POLES: 12 MAXPOSITIONS: 2 TO 4TYPE IC5847C(APPROVED BY EXTENSION)63743 P Green Until: 05-APR-14NCONTACTORS: ACRATING: SIZE 3, 440V, 90 AMPSPOLE: 3TYPE IC5181C103
28、(APPROVED BY EXTENSION)Ward Leonard Test Report No. 09-1206463743 M Green Until: 05-APR-14NCONTACTORS: ACRATING: SIZE 3, 440V, 90 AMPSPOLE: 3TYPE IC5181C103 (APPROVED BY EXTENSION)63743 P Green Until: 05-APR-14NCONTACTORS: ACRATING: SIZE 3, 440V, 90 AMPSPOLE: 3TYPE IC5181D103 (APPROVED BY EXTENSION)
29、Ward Leonard Test Report No. 09-1206463743 M Green Until: 05-APR-14NCONTACTORS: ACRATING: SIZE 3, 440V, 90 AMPSPOLE: 3TYPE IC5181D103 (APPROVED BY EXTENSION)63743 P Green Until: 05-APR-14NCONTROLLERS: AC MAGNETIC CONTACT RATING: SIZE 4, 100HP, 440V, 135 AMPS; ACROSS-THE-LINE W/O OVERLOADTYPE 6956 AP
30、PROVED BY EXTENSION)DRS Test Report No. MC-0064010 of 8/10/0927192 M Green Until: 01-MAR-14NCONTROLLERS: AC MAGNETIC CONTACT RATING: SIZE 4, 100HP, 440V, 135 AMPS; ACROSS-THE-LINE W/O OVERLOADTYPE 6956 APPROVED BY EXTENSION)27192 P Green Until: 01-MAR-14NSWITCHES: SWITCH STATION5 ELEMENT STATIONENCL
31、OSURE: WATERTIGHTCONTACT RATING:440V, 10 AMPS AC;230V, 10 AMPS AC;115V, 10 AMPS AC;230V, 5 AMPS DC;120V, 10 AMPS DCTYPE IC5844M SERIES STATION Ward Leonard Test Report No. 11-1211063743 M Green Until: 05-APR-14NSWITCHES: SWITCH STATION5 ELEMENT STATIONENCLOSURE: WATERTIGHTCONTACT RATING:440V, 10 AMP
32、S AC;230V, 10 AMPS AC;115V, 10 AMPS AC;230V, 5 AMPS DC;120V, 10 AMPS DCTYPE IC5844M SERIES STATION 63743 P Green Until: 05-APR-14NSWITCHES: SWITCH STATION2 ELEMENT STATIONENCLOSURE: WATERTIGHTCONTACT RATING:440V, 10 AMPS AC;230V, 10 AMPS AC;115V, 10 AMPS AC;230V, 5 AMPS DC;120V, 10 AMPS DCTYPE IC584
33、4K (APPROVED BY EXTENSION)Ward Leonard Test Report No. 11-1211063743 M Green Until: 05-APR-14NSWITCHES: SWITCH STATION2 ELEMENT STATIONENCLOSURE: WATERTIGHTCONTACT RATING:440V, 10 AMPS AC;230V, 10 AMPS AC;115V, 10 AMPS AC;230V, 5 AMPS DC;120V, 10 AMPS DCTYPE IC5844K (APPROVED BY EXTENSION)63743 P Gr
34、een Until: 05-APR-14NQPL-22124 of 27Source: QPD at https:/assist.daps.dla.mil - QPL Date: 2013-12-06If past the certification date, contact Qualifying Activity for status.Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-GOVERNMENT DESIGNATION MANUFACT
35、URER DESIGNATION TEST REFERENCE CAGE CODESupplier TypeCertified StatusStop ShipSWITCHES: SWITCH STATION3 ELEMENT STATIONENCLOSURE: WATERTIGHTCONTACT RATING:440V, 10 AMPS AC;230V, 10 AMPS AC;115V, 10 AMPS AC;230V, 5 AMPS DC;120V, 10 AMPS DCTYPE IC5844L (APPROVED BY EXTENSION)Ward Leonard Test Report
36、No. 11-1211063743 M Green Until: 05-APR-14NSWITCHES: SWITCH STATION3 ELEMENT STATIONENCLOSURE: WATERTIGHTCONTACT RATING:440V, 10 AMPS AC;230V, 10 AMPS AC;115V, 10 AMPS AC;230V, 5 AMPS DC;120V, 10 AMPS DCTYPE IC5844L (APPROVED BY EXTENSION)63743 P Green Until: 05-APR-14NSWITCHES: LIMIT ENCLOSURE: WAT
37、ERTIGHT OR EXPLOSION PROOFCONTACT RATING:440V, 1.5 AMPS AC;110V, 6.0 AMPS AC;230V, 1.1 AMPS DC;115V, 2.2 AMPS DCCONTACTS:2NO / 2NCBULLETIN 6984, TYPE T-12 LIMIT SWITCH (APPROVED BY EXTENSION)DRS Test Report No. 270-00470121; DRS Test Rpt MC-02135027192 M Green Until: 01-MAR-14NSWITCHES: LIMIT ENCLOS
38、URE: WATERTIGHT OR EXPLOSION PROOFCONTACT RATING:440V, 1.5 AMPS AC;110V, 6.0 AMPS AC;230V, 1.1 AMPS DC;115V, 2.2 AMPS DCCONTACTS:2NO / 2NCBULLETIN 6984, TYPE T-12 LIMIT SWITCH (APPROVED BY EXTENSION)27192 P Green Until: 01-MAR-14NCONTROLLERS: AC MAGNETICRATING: SIZE 2/2, 440 VAC, 60 HZ, 3-PHASEENCLO
39、SURE: SUBMASTER PLAN 27324, SIZE 2/2, SINGLE-SPEED REVERSING MOTOR CONTROLLER (APPROVED BY EXTENSION)Ward Leonard Test Report No 13-12292 dated 5/9/13; NSWCCD-SSES Ltr to NAVSEA 05Z Ser 939/007 dated 1/25/13; Master Plan 2732363743 M Green Until: 21-OCT-15NCONTROLLERS: AC MAGNETICRATING: SIZE 2/2, 4
40、40 VAC, 60 HZ, 3-PHASEENCLOSURE: SUBMASTER PLAN 27324, SIZE 2/2, SINGLE-SPEED REVERSING MOTOR CONTROLLER (APPROVED BY EXTENSION)63743 P Green Until: 21-OCT-15NRELAYS: ELECTRONIC OVERLOAD RELAY, SINGLE/3-PHASE 110 OR 440 VAC POWER SUPPLY,CONFIGURATION: FIBER OPTIC/COPPER,I/O: 440, 115 VACTYPE: N302 E
41、LECTRONIC OVERLOAD RELAY 115V FIBER OPTIC;N302 ELECTRONIC OVERLOAD RELAY 440V FIBER OPTIC;N302 ELECTRONIC OVERLOAD RELAY 115V COPPER;N302 ELECTRONIC OVERLOAD RELAY 440V COPPER;SINGLE/3-PHASE 110 OR 440 VAC POWER SUPPLY;SINGLE SPEED REVERSING/NON-REVERSING APPLICATIONS;MULTI-SPEED REVERSING/NON-REVER
42、SING APPLICATIONS;I/O: 440, 115 VACWard Leonard Test Report Numbers 10-12091, 11-12108, 11-12105 and 11-1210663743 M Green Until: 28-JAN-15NQPL-22125 of 27Source: QPD at https:/assist.daps.dla.mil - QPL Date: 2013-12-06If past the certification date, contact Qualifying Activity for status.Provided b
43、y IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-GOVERNMENT DESIGNATION MANUFACTURER DESIGNATION TEST REFERENCE CAGE CODESupplier TypeCertified StatusStop ShipRELAYS: ELECTRONIC OVERLOAD RELAY, SINGLE/3-PHASE 110 OR 440 VAC POWER SUPPLY,CONFIGURATION: FIBER OPT
44、IC/COPPER,I/O: 440, 115 VACTYPE: N302 ELECTRONIC OVERLOAD RELAY 115V FIBER OPTIC;N302 ELECTRONIC OVERLOAD RELAY 440V FIBER OPTIC;N302 ELECTRONIC OVERLOAD RELAY 115V COPPER;N302 ELECTRONIC OVERLOAD RELAY 440V COPPER;SINGLE/3-PHASE 110 OR 440 VAC POWER SUPPLY;SINGLE SPEED REVERSING/NON-REVERSING APPLI
45、CATIONS;MULTI-SPEED REVERSING/NON-REVERSING APPLICATIONS;I/O: 440, 115 VAC63743 P Green Until: 28-JAN-15NRELAYS: ELECTRONIC OVERLOAD RELAY, SINGLE/3-PHASE 110 OR 440 VAC POWER SUPPLY,CONFIGURATION: FIBER OPTIC/COPPER,I/O: 440, 115 VACTYPE: NAVY ELECTRONIC MOTOR OPERATOR (NEMO) ELECTRONIC OVERLOAD RE
46、LAY FIBER OPTIC/ COPPERSINGLE/3-PHASE 110 OR 440 VAC POWER SUPPLYSINGLE SPEED REVERSING/NON-REVERSING APPLICATIONSMULTI-SPEED REVERSING/NON-REVERSING APPLICATIONSI/O: 440, 115 VACDRS Test Report Nos dated 12/21/10: MC-014012; MC-014056; MC-014057; MC-014058; MC-014059; MC-014062; MC-014063; MC-01406
47、4; MC-014067; MC-014068; MC-014069; MC-014070; MC-014071; MC-014089; MC-034648 dated 05/14/1327192 M Green Until: 08-MAR-15NRELAYS: ELECTRONIC OVERLOAD RELAY, SINGLE/3-PHASE 110 OR 440 VAC POWER SUPPLY,CONFIGURATION: FIBER OPTIC/COPPER,I/O: 440, 115 VACTYPE: NAVY ELECTRONIC MOTOR OPERATOR (NEMO) ELE
48、CTRONIC OVERLOAD RELAY FIBER OPTIC/ COPPERSINGLE/3-PHASE 110 OR 440 VAC POWER SUPPLYSINGLE SPEED REVERSING/NON-REVERSING APPLICATIONSMULTI-SPEED REVERSING/NON-REVERSING APPLICATIONSI/O: 440, 115 VAC27192 P Green Until: 08-MAR-15NCONTACTORS: AC LOW NOISE/QUIETRATING: SIZE 1, 10HP, 440V, 27 AMPSPOLE:
49、5IC5181D101 Ward Leonard Test Report No. 09-1206263743 M Green Until: 05-APR-14NCONTACTORS: AC LOW NOISE/QUIETRATING: SIZE 1, 10HP, 440V, 27 AMPSPOLE: 5IC5181D101 63743 P Green Until: 05-APR-14NRELAYS: THERMAL OVERLOAD; ONE POLEINTERCHANGEABLEHEATER ELEMENTADJUSTABLE TRIPSETTINGAPPLICABILITY:SIZE 0 5*SEE NOTE*TYPE: N154 Ward LeonardTest Report No. 10-12088 dated 8 March 201063743 M Green Until: 05-APR-14NRELAYS: THERMAL OVERLOAD; TWO POLE