1、*USACE / NAVFAC / AFCESA / NASA UFGS-06 10 00 (February 2012)-Preparing Activity: NAVFAC SupersedingUFGS-06 10 00 (May 2011)UFGS-06 10 00 (November 2009)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated January 2012*SECTION TABLE OF CONTENTSDIVISION 06 - WOOD, PLASTI
2、CS, AND COMPOSITESSECTION 06 10 00ROUGH CARPENTRY02/12PART 1 GENERAL1.1 REFERENCES1.2 SUBMITTALS1.3 DELIVERY AND STORAGE1.4 GRADING AND MARKING1.4.1 Lumber1.4.2 Structural Glued Laminated Timber1.4.3 Plywood1.4.4 Structural-Use and OSB Panels1.4.5 Preservative-Treated Lumber and Plywood1.4.6 Fire-Re
3、tardant Treated Lumber1.4.7 Hardboard, Gypsum Board, and Fiberboard1.4.8 Plastic Lumber1.5 SIZES AND SURFACING1.6 MOISTURE CONTENT1.7 PRESERVATIVE TREATMENT1.7.1 Existing Structures1.7.2 New Construction1.8 FIRE-RETARDANT TREATMENT1.9 QUALITY ASSURANCE1.9.1 Drawing Requirements1.9.2 Data Required1.9
4、.3 Certificates of Grade1.9.4 Humidity Requirements1.9.5 Plastic Lumber Performance1.10 ENVIRONMENTAL REQUIREMENTS1.11 SUSTAINABLE DESIGN REQUIREMENTS1.11.1 Local/Regional Materials1.11.2 Certified Wood1.11.3 Forest Stewardship Council (FSC) CertificationPART 2 PRODUCTS2.1 MATERIALSSECTION 06 10 00
5、Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-2.1.1 Virgin Lumber2.1.2 Salvaged Lumber2.1.3 Recovered Lumber2.1.4 Engineered Wood Products2.1.5 Natural Decay- and Insect-Resistant Wood2.1.6 Plastic Lumber2.1.6.1 Shear Parallel to Length2.1.6.
6、2 Density2.1.6.3 Compressive Strength2.1.6.4 Flexural Strength2.1.6.5 Tensile Strength2.1.6.6 Coefficient of Thermal Expansion2.1.6.7 Screw Withdrawal2.1.6.8 Nail Withdrawal2.2 LUMBER2.2.1 Structural Lumber2.2.2 Framing Lumber2.2.3 Structural Glued Laminated Timber2.3 PLYWOOD, STRUCTURAL-USE, AND OR
7、IENTED STRAND BOARD (OSB) PANELS2.3.1 Subflooring2.3.1.1 Plywood2.3.1.2 Structural-Use and OSB Panels2.3.2 Combination Subfloor-Underlayment2.3.2.1 Plywood2.3.2.2 Structural-Use Panel2.3.3 Wall Sheathing2.3.3.1 Plywood2.3.3.2 Structural-Use and OSB Panels2.3.4 Roof Sheathing2.3.4.1 Plywood2.3.4.2 St
8、ructural-Use Panel2.3.5 Diaphragms2.3.5.1 Plywood2.3.5.2 Structural-Use and OSB Panels2.3.6 Shear Walls2.3.6.1 Plywood2.3.6.2 Structural-Use and OSB Panels2.3.7 Other Uses2.3.7.1 Plywood2.3.7.2 Structural-Use and OSB Panels2.4 UNDERLAYMENT2.4.1 Hardboard2.4.2 Particleboard2.4.3 Plywood2.4.4 Oriented
9、 Strand Board2.4.5 Fiberboard2.4.6 Strawboard Panels2.4.7 Cork2.5 OTHER MATERIALS2.5.1 Hardboard Underlayment2.5.2 Fiberboard Wall Sheathing2.5.3 Gypsum Wall Sheathing2.5.4 Foil-Faced Insulative Sheathing2.5.5 Cellulose Honeycomb Panels2.5.6 Building Paper2.5.7 Trussed Rafters2.5.8 Trussed Joists2.5
10、.9 Roof Decking2.5.10 Miscellaneous Wood MembersSECTION 06 10 00 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-2.5.10.1 Nonstress Graded Members2.5.10.2 Wood Bumpers2.5.10.3 Sill Plates2.5.10.4 Blocking2.5.10.5 Rough Bucks and Frames2.5.11 Ad
11、hesives2.6 ROUGH HARDWARE2.6.1 Bolts, Nuts, Studs, and Rivets2.6.2 Anchor Bolts2.6.3 Expansion Shields2.6.4 Lag Screws and Lag Bolts2.6.5 Wood Screws2.6.6 Nails and Staples2.6.7 Wire Nails2.6.8 Timber Connectors2.6.9 Clip Angles2.6.10 Joist Hangers2.6.11 Tie Straps2.6.12 Joist Anchors2.6.13 Door Buc
12、k Anchors2.6.14 Metal Bridging2.6.15 Toothed Rings and Shear Plates2.6.16 Beam Anchors2.6.17 Metal Framing Anchors2.6.18 Panel Edge Clips2.7 AIR INFILTRATION BARRIERPART 3 EXECUTION3.1 INSTALLATION3.1.1 Sills3.1.1.1 Anchors in Masonry3.1.1.2 Anchors in Concrete3.1.2 Beams and Girders3.1.3 Roof Frami
13、ng or Rafters3.1.4 Joists3.1.4.1 Floor (Ceiling) Framing3.1.4.2 Doubled Joists3.1.4.3 Tie Straps3.1.4.4 Joist Anchors3.1.5 Bridging3.1.5.1 Wood Cross-Bridging3.1.5.2 Metal Cross-Bridging3.1.6 Subflooring3.1.6.1 Plywood, Structural-Use, and OSB Panels3.1.6.2 Combination Subfloor-Underlayment3.1.6.3 W
14、ood3.1.6.4 Depressed Subfloors3.1.7 Underlayment3.1.8 Columns and Posts3.1.9 Wall Framing3.1.9.1 Studs3.1.9.2 Plates3.1.9.3 Firestops3.1.9.4 Diagonal Bracing3.1.10 Wall Sheathing3.1.10.1 Plywood, Structural-Use, and OSB Panel Wall Sheathing3.1.10.2 Fiberboard Wall Sheathing3.1.10.3 Gypsum Sheathing
15、BoardSECTION 06 10 00 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-3.1.10.4 Foil-Faced Insulative Sheathing3.1.10.5 Particleboard3.1.10.6 Cellulose Honeycomb Panels3.1.11 Wood Sheathing3.1.12 Building Paper3.1.13 Ceiling Joists3.1.14 Metal F
16、raming Anchors3.1.15 Trusses3.1.16 Structural Glued Laminated Timber Members3.1.17 Plywood and Structural-Use Panel Roof Sheathing3.1.18 Stair Framing3.1.19 Plastic Lumber3.2 MISCELLANEOUS3.2.1 Wood Roof Nailers, Edge Strips, Crickets, Curbs, and Cants3.2.1.1 Roof Nailing Strips3.2.1.2 Roof Edge Str
17、ips and Nailers3.2.1.3 Crickets, Cants, and Curbs3.2.2 Rough Wood Bucks3.2.3 Wood Blocking3.2.4 Wood Grounds3.2.5 Wood Furring3.2.6 Wood Bumpers3.2.7 Temporary Closures3.2.8 Temporary Centering, Bracing, and Shoring3.2.9 Wood Sleepers3.2.10 Diaphragms3.2.11 Shear Walls3.2.12 Bridging3.2.13 Corner Br
18、acing3.2.14 Sill Plates3.3 INSTALLATION OF TIMBER CONNECTORS3.4 ERECTION TOLERANCES3.5 SPECIAL INSPECTION AND TESTING FOR SEISMIC-RESISTING SYSTEMS3.6 WASTE MANAGEMENT3.7 SCHEDULE- End of Section Table of Contents -SECTION 06 10 00 Page 4Provided by IHSNot for ResaleNo reproduction or networking per
19、mitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-06 10 00 (February 2012)-Preparing Activity: NAVFAC SupersedingUFGS-06 10 00 (May 2011)UFGS-06 10 00 (November 2009)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated January 2012*SECTION 06 10 0
20、0ROUGH CARPENTRY02/12*NOTE: This guide specification covers framing, grounds, nailers, blocking, and sheathing of light wooden structures and includes the use of preassembled components and plastic lumber. Wood finished flooring, trim, millwork, siding, heavy timber work, custom woodwork, and finish
21、 carpentry are specified in other sections.Adhere to UFC 1-300-02 Unified Facilities Guide Specifications (UFGS) Format Standard when editing this guide specification or preparing new project specification sections. Edit this guide specification for project specific requirements by adding, deleting,
22、 or revising text. For bracketed items, choose applicable items(s) or insert appropriate information.Remove information and requirements not required in respective project, whether or not brackets are present.Comments, suggestions and recommended changes for this guide specification are welcome and
23、should be submitted as a Criteria Change Request (CCR).*NOTE: The following information should be shown on the project drawings:1. Sizes and spacing of all wood framing members including trussed rafters and trusses2. Location, size, type, and thickness of all materials3. Size and spacing of anchor b
24、olts4. Details of all connections and anchorage where special conditions exist such as high wind, SECTION 06 10 00 Page 5Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-hurricane, and earthquake areas5. Design loads6. Design unit stresses for structu
25、ral lumber7. Details of depressed floors to receive ceramic tile.*PART 1 GENERAL1.1 REFERENCES*NOTE: Issue (date) of references included in project specifications need not be more current than provided by the latest guide specification. Use of SpecsIntact automated reference checking is recommended
26、for projects based on older guide specifications.*The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.AMERICAN FOREST R 2004) Basic HardboardAMERICAN INSTITUTE OF TIMBER CONSTRUCTION
27、(AITC)AITC 111 (2005) Recommended Practice for Protection of Structural Glued Laminated Timber During Transit, Storage and ErectionAITC TCM (2004; Errata 2010) Timber Construction Manual, 5th EditionANSI/AITC A190.1 (2007) American National Standard, Structural Glued Laminated TimberAMERICAN LUMBER
28、STANDARDS COMMITTEE (ALSC)ALSC PS 20 (2010) American Softwood Lumber StandardAMERICAN RAILWAY ENGINEERING AND MAINTENANCE-OF-WAY ASSOCIATION (AREMA)AREMA Eng Man (2010) Manual for Railway EngineeringSECTION 06 10 00 Page 6Provided by IHSNot for ResaleNo reproduction or networking permitted without l
29、icense from IHS-,-,-AMERICAN WOOD PROTECTION ASSOCIATION (AWPA)AWPA BOOK (2009) AWPA Book of StandardsAWPA M2 (2007) Standard for Inspection of Treated Wood ProductsAWPA M6 (2007) Brands Used on Forest ProductsAWPA P18 (2007) Nonpressure PreservativesAWPA P49 (2010) Standard for Fire Retardant FR-1A
30、WPA P5 (2009) Standard for Waterborne PreservativesAWPA T1 (2009) Use Category System: Processing and Treatment StandardAWPA U1 (2009) Use Category System: User Specification for Treated WoodAPA - THE ENGINEERED WOOD ASSOCIATION (APA)APA E30 (2011) Engineered Wood Construction GuideAPA E445 (2002) P
31、erformance Standards and Qualification Policy for Structural-Use Panels (APA PRP-108)APA EWS R540 (2007) Builder Tips Proper Storage and Handling of Glulam BeamsAPA EWS T300 (2007) Technical Note: Glulam Connection DetailsAPA F405 (1999) Performance Rated PanelsAPA L870 (2010) Voluntary Product Stan
32、dard, PS 1-09, Structural PlywoodAPA S350 (2011) Performance Standard for Wood-Based Structural-Use PanelsASME INTERNATIONAL (ASME)ASME B18.2.1 (2010) Square and Hex Bolts and Screws (Inch Series)ASME B18.2.2 (2010) Standard for Square and Hex NutsASME B18.5.2.1M (2006; R 2011) Metric Round Head Sho
33、rt Square Neck BoltsASME B18.5.2.2M (1982; R 2010) Metric Round Head Square Neck BoltsASME B18.6.1 (1981; R 2008) Wood Screws (Inch Series)SECTION 06 10 00 Page 7Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-ASTM INTERNATIONAL (ASTM)ASTM A153/A153M
34、 (2009) Standard Specification for Zinc Coating (Hot-Dip) on Iron and Steel HardwareASTM A307 (2010) Standard Specification for Carbon Steel Bolts and Studs, 60 000 PSI Tensile StrengthASTM A653/A653M (2011) Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (
35、Galvannealed) by the Hot-Dip ProcessASTM C1136 (2010) Standard Specification for Flexible, Low Permeance Vapor Retarders for Thermal InsulationASTM C1396/C1396M (2011) Standard Specification for Gypsum BoardASTM C208 (2008a) Cellulosic Fiber Insulating BoardASTM D1435 (2005) Standard Practice for Ou
36、tdoor Weathering of PlasticsASTM D1972 (1997; R 2005) Standard Practice for Generic Marking of Plastic ProductsASTM D198 (2009) Standard Test Methods of Static Tests of Lumber in Structural SizesASTM D2344/D2344M (2000; R 2006) Standard Test Method for Short-Beam Strength of Polymer Matrix Composite
37、 Materials and Their LaminatesASTM D2898 (2010) Accelerated Weathering of Fire-Retardant-Treated Wood for Fire TestingASTM D3498 (2011) Adhesives for Field-Gluing Plywood to Lumber Framing for Floor SystemsASTM D6007 (2002; R 2008) Standard Test Method for Determining Formaldehyde Concentration in A
38、ir from Wood Products Using a Small Scale ChamberASTM D6108 (2009) Standard Test Method for Compressive Properties of Plastic Lumber and ShapesASTM D6109 (2010) Standard Test Methods for Flexural Properties of Unreinforced and Reinforced Plastic Lumber and Related ProductsASTM D6111 (2009) Standard
39、Test Method for Bulk SECTION 06 10 00 Page 8Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Density and Specific Gravity of Plastic Lumber and Shapes by DisplacementASTM D6112 (2010) Compressive and Flexural Creep and Creep-Rupture of Plastic Lumber
40、and ShapesASTM D6117 (2010) Standard Test Methods for Mechanical Fasteners in Plastic Lumber and ShapesASTM D6330 (1998; R 2008) Standard Practice for Determination of Volatile Organic Compounds (Excluding Formaldehyde) Emissions from Wood-Based Panels Using Small Environmental Chambers Under Define
41、d Test ConditionsASTM D696 (2008) Standard Test Method for Coefficient of Linear Thermal Expansion of Plastics Between -30 degrees C and 30 degrees C With a Vitreous Silica DilatometerASTM E1333 (2010) Determining Formaldehyde Concentrations in Air and Emission Rates from Wood Products Using a Large
42、 ChamberASTM E96/E96M (2010) Standard Test Methods for Water Vapor Transmission of MaterialsASTM F 1667 (2011) Driven Fasteners: Nails, Spikes, and StaplesASTM F 547 (2006) Nails for Use with Wood and Wood-Base MaterialsCOMPOSITE PANEL ASSOCIATION (CPA)CPA A208.1 (2009) Medium Density Fiberboard (MD
43、F) For Interior ApplicationsFM GLOBAL (FM)FM 4435 (2004) Roof Perimeter FlashingFOREST STEWARDSHIP COUNCIL (FSC)FSC STD 01 001 (2000) Principles and Criteria for Forest StewardshipGREEN SEAL (GS)GS-36 (2000) Commercial AdhesivesINTERNATIONAL CODE COUNCIL (ICC)ICC IBC (2009; Errata First Printing) In
44、ternational Building CodeSECTION 06 10 00 Page 9Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-NATIONAL HARDWOOD LUMBER ASSOCIATION (NHLA)NHLA Rules (2007) Rules for the Measurement R 2005) Adhesive and Sealant ApplicationsSOUTHERN CYPRESS MANUFACTU
45、RERS ASSOCIATION (SCMA)SCMA Spec (1986; Supple. No. 1, Aug 1993) Standard Specifications for Grades of Southern CypressSOUTHERN PINE INSPECTION BUREAU (SPIB)SPIB 1003 (2002) Standard Grading Rules for Southern Pine LumberTRUSS PLATE INSTITUTE (TPI)TPI 1 (2002) National Design Standard for Metal Plate Connected Wood Truss Construction; Commentary and AppendicesTPI HIB (1991) Commentary and Recommendations for Handling, Installing and Bracing Metal Plate Connected Wood TrussesU.S. DEPARTMENT OF COMMERCE (DOC)DOC/NIST PS56 (1973)