1、*USACE / NAVFAC / AFCESA / NASA UFGS-10 51 13 (May 2011)-Preparing Activity: NAVFAC SupersedingUFGS-10 51 13 (July 2007)UFGS-10 51 13 (April 2006)UFGS-10 51 00.00 40 (April 2007)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated April 2011*SECTION TABLE OF CONTENTSDIV
2、ISION 10 - SPECIALTIESSECTION 10 51 13METAL LOCKERS05/11PART 1 GENERAL1.1 REFERENCES1.2 SUBMITTALS1.3 DELIVERY, HANDLING, AND STORAGE1.4 FIELD MEASUREMENTS1.5 QUALITY ASSURANCE1.5.1 Color ChipsPART 2 PRODUCTS2.1 TYPES2.1.1 Single-tier Lockers2.1.2 Double-Tier2.2 MATERIAL2.2.1 Galvanized Steel Sheet2
3、.2.2 Chromium Coating2.2.3 Finish2.2.3.1 Color2.3 COMPONENTS2.3.1 Built-In Locks2.3.2 Coat Hooks2.3.3 Hanger Rods2.3.4 Door Handles2.3.5 Doors2.3.5.1 Hinges2.3.5.2 Latching Mechanisms2.3.6 Latch Strikes2.3.7 Silencers2.3.8 Back and Side Panels, Tops, and Bottoms2.3.9 Sloping Locker Tops2.3.10 Shelve
4、s2.3.11 Base Panels2.3.12 LegsSECTION 10 51 13 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-2.3.13 Number Plates2.3.14 Label Holders2.3.15 Fastening DevicesPART 3 EXECUTION3.1 ASSEMBLY AND INSTALLATION3.2 NUMBERING SYSTEM3.3 FIELD QUALITY CO
5、NTROL3.3.1 Testing3.3.2 Repairing3.3.3 Cleaning- End of Section Table of Contents -SECTION 10 51 13 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-10 51 13 (May 2011)-Preparing Activity: NAVFAC SupersedingU
6、FGS-10 51 13 (July 2007)UFGS-10 51 13 (April 2006)UFGS-10 51 00.00 40 (April 2007)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated April 2011*SECTION 10 51 13METAL LOCKERS05/11*NOTE: This guide specification covers the requirements for permanently installed metal lo
7、ckers; single and double tier, used for temporary storage and security of personal belongings.Adhere to UFC 1-300-02 Unified Facilities Guide Specifications (UFGS) Format Standard when editing this guide specification or preparing new project specification sections. Edit this guide specification for
8、 project specific requirements by adding, deleting, or revising text. For bracketed items, choose applicable items(s) or insert appropriate information. Remove information and requirements not in respective project, whether or not brackets are present.Comments, suggestions and recommended changes fo
9、r this guide specification are welcome and should be submitted as a Criteria Change Request (CCR).*NOTE: Show the following information on the drawings:1. Location, type and size, quantity, and color of lockers2. Mounting details and whether legs, base panels, or pre-built bases are required.*PART 1
10、 GENERAL1.1 REFERENCES*NOTE: This paragraph is used to list the publications cited in the text of the guide SECTION 10 51 13 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-specification. The publications are referred to in the text by basic de
11、signation only and listed in this paragraph by organization, designation, date, and title.Use the Reference Wizards Check Reference feature when you add a RID outside of the Sections Reference Article to automatically place the reference in the Reference Article. Also use the Reference Wizards Check
12、 Reference feature to update the issue dates.References not used in the text will automatically be deleted from this section of the project specification when you choose to reconcile references in the publish print process.*The publications listed below form a part of this specification to the exten
13、t referenced. The publications are referred to within the text by the basic designation only.ASTM INTERNATIONAL (ASTM)ASTM A1008/A1008M (2010) Standard Specification for Steel, Sheet, Cold-Rolled, Carbon, Structural, High-Strength Low-Alloy and High-Strength Low-Alloy with Improved Formability, Solu
14、tion Hardened, and Bake HardenedASTM A568/A568M (2009a) Standard Specifications for Steel, Sheet, Carbon, Structural, and High-Strength, Low-Alloy, Hot-Rolled and Cold-Rolled, General Requirements forASTM A653/A653M (2010) Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron
15、 Alloy-Coated (Galvannealed) by the Hot-Dip ProcessASTM A924/A924M (2010a) Standard Specification for General Requirements for Steel Sheet, Metallic-Coated by the Hot-Dip ProcessASTM B 456 (2003; R 2009) Standard Specification for Electrodeposited Coatings of Copper Plus Nickel Plus Chromium and Nic
16、kel Plus ChromiumASTM D 6386 (2010) Standard Practice for Preparation of Zinc (Hot-Dip Galvanized) Coated Iron and Steel Product and Hardware Surfaces for PaintingU.S. DEPARTMENT OF DEFENSE (DOD)MIL-PRF-22750 (1994; Rev F) Coating, Epoxy, High SolidsMIL-PRF-23377 (2007; Rev J; Am 2 2007) Primer Coat
17、ings: SECTION 10 51 13 Page 4Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Epoxy, High SolidsU.S. GENERAL SERVICES ADMINISTRATION (GSA)FS AA-L-00486 (Rev J) Lockers, Clothing, Steel1.2 SUBMITTALS*NOTE: Review submittal description (SD) definitions
18、in Section 01 33 00 SUBMITTAL PROCEDURES and edit the following list to reflect only the submittals required for the project. Submittals should be kept to the minimum required for adequate quality control.A “G” following a submittal item indicates that the submittal requires Government approval. Som
19、e submittals are already marked with a “G”. Only delete an existing “G” if the submittal item is not complex and can be reviewed through the Contractors Quality Control system. Only add a “G” if the submittal is sufficiently important or complex in context of the project.For submittals requiring Gov
20、ernment approval on Army projects, a code of up to three characters within the submittal tags may be used following the “G“ designation to indicate the approving authority. Codes for Army projects using the Resident Management System (RMS) are: “AE“ for Architect-Engineer; “DO“ for District Office (
21、Engineering Division or other organization in the District Office); “AO“ for Area Office; “RO“ for Resident Office; and “PO“ for Project Office. Codes following the “G“ typically are not used for Navy, Air Force, and NASA projects.Choose the first bracketed item for Navy, Air Force and NASA projects
22、, or choose the second bracketed item for Army projects.*Government approval is required for submittals with a “G“ designation; submittals not having a “G“ designation are for Contractor Quality Control approval.for information only. When used, a designation following the “G“ designation identifies
23、the office that will review the submittal for the Government. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:SD-02 Shop DrawingsTypes; G; G, _Location; G; G, _Installation Numbering systemSECTION 10 51 13 Page 5Provided by IHSNot for ResaleNo reproduction or networking
24、 permitted without license from IHS-,-,-SD-03 Product DataMaterialLocking Devices*NOTE: Delete the following paragraph if built-in combination locks or built-in key locks are not required.* Lock Control ChartHandlesFinishLocker componentsAssembly instructionsSD-04 SamplesColor chips; G; G, _1.3 DELI
25、VERY, HANDLING, AND STORAGEDeliver lockers and associated materials in their original packages, containers, or bundles bearing the manufacturers name and the name of the material. Protect from weather, soil, and damage during delivery, storage, and construction.1.4 FIELD MEASUREMENTSTo ensure proper
26、 fits, make field measurements prior to the preparation of drawings and fabrication. Verify correct location1.5 QUALITY ASSURANCE1.5.1 Color ChipsProvide a minimum of three color chips, not less than 75 mm 3 inches square, of each color scheduled indicated.Government may request performance-characte
27、ristic tests on assembled lockers. Tests and results must conform to FS AA-L-00486. Lockers not conforming will be rejected.PART 2 PRODUCTS2.1 TYPES*NOTE: Locker type and quantities must be indicated.*Locker must have the following type and size in the location and quantities indicated. Locker finis
28、h colors will be as scheduled.SECTION 10 51 13 Page 6Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-2.1.1 Single-tier LockersSingle-tier lockers must be as follows:*NOTE: Delete the paragraph heading and the following paragraphs if single-tier locke
29、rs are not required.Select from the following for single-tier lockers with legs to suit the project. Delete inapplicable paragraphs.* Type STL-1: Single-tier locker 380 millimeter wide, 380 millimeter deep, and 1830 millimeter high 15 inches wide, 15 inches deep, and 72 inches high, attached to 150
30、millimeter 6-inch high legs Type STL-2: Single-tier locker 380 millimeter wide, 457 millimeter deep, and 1830 millimeter high 15 inches wide, 18 inches deep, and 72 inches high, attached to 150 millimeter 6-inch high legs Type STL-3: Single-tier locker 457 millimeter wide, 533 millimeter deep, and 1
31、830 millimeter high 18 inches wide, 21 inches deep, and 72 inches high, attached to 150 millimeter 6-inch high legs Type STL-4: Single-tier locker 457 millimeter wide, 610 millimeter deep, and 1830 millimeter high 18 inches wide, 24 inches deep, and 72 inches high, attached to 150 millimeter 6-inch
32、high legs*NOTE: Select from the following for single-tier lockers with a closed base to suit the project. Delete inapplicable paragraphs.* Type STC-1: Single-tier locker 380 millimeter wide, 380 millimeter deep, and 1830 millimeter high 15 inches wide, 15 inches deep, and 72 inches high, attached to
33、 150 millimeter 6-inch closed base Type STC-2: Single-tier locker 380 millimeter wide, 457 millimeter deep, and 1830 millimeter high 15 inches wide, 18 inches deep, and 72 inches high, attached to 150 millimeter 6-inch high closed base Type STC-3: Single-tier locker 457 millimeter wide, 533 millimet
34、er deep, and 1830 millimeter high 18 inches wide, 21 inches deep, and 72 inches high, attached to 150 millimeter 6-inch high closed base Type STC-4: Single-tier locker 457 millimeter wide, 610 millimeter deep, and 1830 millimeter high 18 inches wide, 24 inches deep, and 72 inches high, attached to 1
35、50 millimeter 6-inch high closed base*NOTE: Select from the following for single-tier lockers without a base to be installed on a prebuilt base. Base must be detailed on the drawings.*SECTION 10 51 13 Page 7Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS
36、-,-,- Type STW-2: Single-tier locker 380 millimeter wide, 457 millimeter deep, and 1830 millimeter 15 inches wide, 18 inches deep, and 72 inches high, without base Type STW-3: Single-tier locker 457 millimeter wide, 533 millimeter deep, and 1830 millimeter 18 inches wide, 21 inches deep, and 72 inch
37、es high, without base Type STW-4: Single-tier locker 457 millimeter wide, 610 millimeter deep and 1830 millimeter 18 inches wide, 24 inches deep, and 72 inches high, without base2.1.2 Double-TierDouble-tier lockers must be as follows:*NOTE: Delete the paragraph heading and the following paragraphs i
38、f double-tier lockers are not required.Select from the following for double-tier lockers with legs to suit the project. Delete inapplicable paragraphs.*Type DTL-1: Double-tier locker 380 millimeter wide, 380 millimeter deep, and 1830 millimeter 15 inches wide, 15 inches deep, and 72 inches high, att
39、ached to 150 millimeter 6-inch high legsType DTL-2: Double-tier locker 380 millimeter wide, 457 millimeter deep, and 1830 millimeter 15 inches wide, 18 inches deep, and 72 inches high, attached to 150 millimeter 6-inch high legs*NOTE: Select from the following for double-tier lockers with a closed b
40、ase to suit the project. Delete inapplicable paragraphs.*Type DTC-1: Double-tier locker 380 millimeter wide, 380 millimeter deep, and 1830 millimeter 15 inches wide, 15 inches deep, and 72 inches high, attached to a 150 millimeter 6-inch high closed baseType DTC-2: Double-tier locker 380 millimeter
41、wide, 457 millimeter deep, and 1830 millimeter 15 inches wide, 18 inches deep, and 72 inches high, attached to a 150 millimeter 6-inch high closed base*NOTE: Select from the following for double-tier lockers without a base to be installed on a prebuilt base. Base details must be detailed.*Type DTW-1: Double-tier locker 380 millimeter wide, 380 millimeter deep, and 1830 millimeter 15 inches wide, 15 inches deep, and 72 inches high, without baseSECTION 10 51 13 Page 8Provided by IHSNot for ResaleNo reproduction or networking permitted wi