1、AEROSPACE STANDARD HOSE ASSEMBLY, LINED SILICONE, 125 PSI, FIXED CAVITY COUPLING, POTABLE WATER,STRAIGHT FEMALE TO STRAIGHT MALE AS4796Copyright 2010 SAE International All rights reserved. No part of this publication may be reproduced, stored in a retrieval system or transmitted, in any form or by a

2、ny means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: +1 724-776-4970 (outside USA) Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae

3、.org ISSUED 1993-06REAFFIRMED 2007-01 REVISED 2010-11THIRD ANGLE PROJECTION CUSTODIAN: G-3/G-3D REV.CFEDERAL SUPPLY CLASS 4720 AS4796SHEET 1 OF 2REV. CPROCUREMENT SPECIFICATION: AS4468 /2/SAE Technical Standards Board Rules provide that: “This report ispublishedby SAE toadvance thestate of technical

4、andengineering sciences. Theuse ofthis report is entirely voluntary, andits applicability and suitability forany particular use,including any patent infringement arising therefrom, isthe soleresponsibilityofthe user.”SAE reviews eachtechnicalreport at least every five years at which time itmay berea

5、ffirmed, revised, orcancelled. SAE invites yourwrittencomments andsuggestions. SAE values your input. To provide feedbackon this Technical Report, please visit http:/www.sae.org/technical/standards/AS4796CRATIONALE CORRECTED “MATES WITH” REFERENCE. FIGURE 1 - HOSE ASSEMBLY TABLE 1 - BASIC HOSE AND E

6、ND FITTING DIMENSIONS BASIC NO. ANDSIZE CODE HOSE SIZE(REF) AMAXB(REF) CMAXID(REF) OD MINOD MAXAS4796-08 .500 1.60 .425 1.40 .500 .65 .73 AS4796-10 .625 1.60 .550 1.40 .625 .81 .85 AS4796-12 .750 1.84 .654 1.53 .750 .94 .98 AS4796-16 1.000 1.92 .909 1.73 1.000 1.19 1.23 TABLE 2 - LENGTH TOLERANCE HO

7、SE ASSEMBLY LENGTH PREFERRED INCREMENTS TOLERANCE UNDER 18 IN (NOT LESS THAN) .125 +.125/-.125 18 TO 36 IN EXCLUSIVE (NOT LESS THAN) .250 +.250/-.250 36 TO 100 IN EXCLUSIVE (NOT LESS THAN) .500 +.375/-.375 100 IN AND OVER (NOT LESS THAN) 1.000 +.5%/-.500 TABLE 3 - HOSE ASSEMBLY WEIGHT INFORMATION HO

8、SE SIZECODE HOSE LB/INNOM (REF) END FITTING LB/EAFEMALENOM (REF) END FITTING LB/EAMALENOM (REF) HOSE LENGTH CORRECTION FACTOR, INCH /9/ FEMALEHOSE LENGTH FITTING CORRECTION FACTOR, INCH /9/ MALE08 .0081 .055 .038 .96 .70 10 .0111 .067 .047 .96 .70 12 .0137 .110 .083 1.04 .75 16 .0182 .146 .118 1.12

9、.80 AEROSPACE STANDARD AS4796SHEET 2 OF 2REV. CHOSE ASSEMBLY, LINED SILICONE, 125 PSI, FIXED CAVITY COUPLING, POTABLE WATER, STRAIGHT FEMALE TO STRAIGHT MALE NOTES: 1. MATERIAL AND FINISH: PER AS4468, TABLE 1. ALL FITTING COMPONENTS 300 SERIES CORROSION RESISTANT STEEL, PASSIVATED./2/ PROCUREMENT SP

10、ECIFICATION: AS4468 EXCEPT AS SPECIFIED ON THIS STANDARD. PRODUCT SUPPLIED TO THIS SPECIFICATION SHALL BE MANUFACTURED AND ASSEMBLED BY AN ACCREDITED MANUFACTURER OR ASSEMBLED BY AN ACCREDITED DISTRIBUTOR LISTED IN THE PERFORMANCE REVIEW INSTITUTE (PRI) QUALIFIED PRODUCTS LIST (QPL) PRI QPL AS4468 F

11、OR THIS STANDARD. SEE FOR CURRENT QPL ON LINE. 3. INTENDED USE: THESE HOSE ASSEMBLIES ARE INTENDED FOR USE IN POTABLE WATER SYSTEM INSTALLATIONS WHERE A HIGH DEGREE OF FLEXIBILITY IS REQUIRED. 4. IDENTIFICATION: PER AS4468. 5. OPERATING CHARACTERISTICS: a. OPERATING TEMPERATURE: -65 TO +160 F (-54

12、TO +71 C). b. OPERATING PRESSURE: 125 PSI MAX 6. FUNCTIONAL TEST AND CLEANING: PER AS4468. 7. CONSTRUCTION: PER AS4468. /8/ LENGTH “L” IS A FOUR-DIGIT NUMBER OF WHICH THE FIRST THREE DIGITS DESCRIBE THE HOSE ASSEMBLY LENGTH IN WHOLE INCHES, AND THE FOURTH DIGIT THE FRACTION OF AN INCH IN EIGHTHS. LE

13、NGTH “L” IS MEASURED FROM “GAGE POINT” TO “GAGE POINT”. SEE TABLE 2 FOR LENGTH TOLERANCES. /9/ HOSE WEIGHT PLUS EACH END FITTING WEIGHT EQUALS HOSE ASSEMBLY WEIGHT. FOR DETERMINING HOSE WEIGHT, DEDUCT APPROPRIATE LENGTH CORRECTION FACTOR FROM EACH END OF THE ASSEMBLY LENGTH. 10. DIMENSIONING AND TOL

14、ERANCING: ASME Y14.5M-1994. 11. DIMENSIONS IN INCHES. UNLESS OTHERWISE SPECIFIED, TOLERANCES: LINEAR DIMENSIONS .010, ANGULAR DIMENSIONS 2 DEGREES. 12. EXAMPLE OF PART NUMBER: AS4796 - 08 - 024 2FRACTIONAL LENGTH IN EIGHTHS OF AN INCH INCREMENTS (.25 IN) /8/ LENGTH IN WHOLE INCHES (24 IN) /8/ BASIC

15、HOSE ASSEMBLY SIZE CODE (.5 IN HOSE SIZE) (SEE TABLE 1) BASIC PART NUMBER 13. A CHANGE BAR (|) LOCATED IN THE LEFT MARGIN IS FOR THE CONVENIENCE OF THE USER IN LOCATING AREAS WHERE TECHNICAL REVISIONS, NOT EDITORIAL CHANGES HAVE BEEN MADE TO THE PREVIOUS ISSUE OF THIS DOCUMENT. AN (R) SYMBOL TO THE LEFT OF THE DOCUMENT TITLE INDICATES A COMPLETE REVISION OF THE DOCUMENT, INCLUDING TECHNICAL REVISIONS. CHANGE BARS AND (R) ARE NOT USED IN ORIGINAL PUBLICATIONS NOR IN DOCUMENTS THAT CONTAIN EDITORIAL CHANGES ONLY.

展开阅读全文
相关资源
猜你喜欢
  • DIN 44897-1-1977 Stationary electric water heaters dimensions and permissible pressure losses for mixing batteries for open-outlet water heaters above table《固定式电热水器 第1部分 台置式敝口热水器用混.pdf DIN 44897-1-1977 Stationary electric water heaters dimensions and permissible pressure losses for mixing batteries for open-outlet water heaters above table《固定式电热水器 第1部分 台置式敝口热水器用混.pdf
  • DIN 44899-4-1980 Thermal storage water heater calculation of thickness of the wall of boilers up to 50 litres rated capacity safety requirements《蓄水式热水器 第4部分 额定容量最高可达 50 升 的锅炉壁厚的计算 .pdf DIN 44899-4-1980 Thermal storage water heater calculation of thickness of the wall of boilers up to 50 litres rated capacity safety requirements《蓄水式热水器 第4部分 额定容量最高可达 50 升 的锅炉壁厚的计算 .pdf
  • DIN 44899-5-1971 Electrical water-heater directions of the calculation of thickness of the wall for containers of closed heaters from 50 up to 2000 liters《电热水器 容量50至2000升的封闭式热水器壳体壁.pdf DIN 44899-5-1971 Electrical water-heater directions of the calculation of thickness of the wall for containers of closed heaters from 50 up to 2000 liters《电热水器 容量50至2000升的封闭式热水器壳体壁.pdf
  • DIN 44899-6-1986 Electrical water heaters rated capacity up to 1000 litres requirements for low-noice level design《电热水器 额定容量为1000升以内 低噪声水平设计的要求》.pdf DIN 44899-6-1986 Electrical water heaters rated capacity up to 1000 litres requirements for low-noice level design《电热水器 额定容量为1000升以内 低噪声水平设计的要求》.pdf
  • DIN 44901-1-1985 Electric thermal storage water heater for floor-mounting 200 to 1000 litres dimensions for closed type《立式结构200至1000升的电蓄热水加热器 封闭式加热器的尺寸》.pdf DIN 44901-1-1985 Electric thermal storage water heater for floor-mounting 200 to 1000 litres dimensions for closed type《立式结构200至1000升的电蓄热水加热器 封闭式加热器的尺寸》.pdf
  • DIN 44901-2-1982 Electric water heater thermal storage water heater floor mounting type capacity 200 up to 1000 litres rated input《电热水器 第3部分 立地式额定注水量为 200 - 1000 升的储水电热水器》.pdf DIN 44901-2-1982 Electric water heater thermal storage water heater floor mounting type capacity 200 up to 1000 litres rated input《电热水器 第3部分 立地式额定注水量为 200 - 1000 升的储水电热水器》.pdf
  • DIN 44902-1-1980 Electric thermal storage water heater 5 to 15 litres mounting dimensions《5 - 15 升储水式电热水器 第1部分 安装尺寸》.pdf DIN 44902-1-1980 Electric thermal storage water heater 5 to 15 litres mounting dimensions《5 - 15 升储水式电热水器 第1部分 安装尺寸》.pdf
  • DIN 44902-2-1982 Electric thermal storage water heater for wall-mounting 30 to 150 liters mounting dimensions《30至150升悬挂式电蓄热水加热器 安装尺寸》.pdf DIN 44902-2-1982 Electric thermal storage water heater for wall-mounting 30 to 150 liters mounting dimensions《30至150升悬挂式电蓄热水加热器 安装尺寸》.pdf
  • DIN 44902-3-1982 Electric water heater thermal storage water heater wall mounting type capacity 5 up to 150 litres rated input《电热水器 第3部分 挂墙式额定注水量为 5 - 150 升的储水电热水器》.pdf DIN 44902-3-1982 Electric water heater thermal storage water heater wall mounting type capacity 5 up to 150 litres rated input《电热水器 第3部分 挂墙式额定注水量为 5 - 150 升的储水电热水器》.pdf