UL 2115-2017 UL Standard for Safety Processed Solid-Fuel Firelogs and Firestarters (Fourth Edition)《处理的固体燃料燃材和起火剂》.pdf

上传人:孙刚 文档编号:1067809 上传时间:2019-04-02 格式:PDF 页数:21 大小:767.13KB
下载 相关 举报
UL 2115-2017 UL Standard for Safety Processed Solid-Fuel Firelogs and Firestarters (Fourth Edition)《处理的固体燃料燃材和起火剂》.pdf_第1页
第1页 / 共21页
UL 2115-2017 UL Standard for Safety Processed Solid-Fuel Firelogs and Firestarters (Fourth Edition)《处理的固体燃料燃材和起火剂》.pdf_第2页
第2页 / 共21页
UL 2115-2017 UL Standard for Safety Processed Solid-Fuel Firelogs and Firestarters (Fourth Edition)《处理的固体燃料燃材和起火剂》.pdf_第3页
第3页 / 共21页
UL 2115-2017 UL Standard for Safety Processed Solid-Fuel Firelogs and Firestarters (Fourth Edition)《处理的固体燃料燃材和起火剂》.pdf_第4页
第4页 / 共21页
UL 2115-2017 UL Standard for Safety Processed Solid-Fuel Firelogs and Firestarters (Fourth Edition)《处理的固体燃料燃材和起火剂》.pdf_第5页
第5页 / 共21页
点击查看更多>>
资源描述

1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL ANSI/CAN/UL/ULC 2115:2017, Processed Solid-Fuel Firelogs and Firestarters STANDARD FOR SAFETY JOINT CANADA-UNITED STATES NATIONAL STANDARD ANSI/UL 2115-2017UL COPYRIGHTED MATERIAL NOT AUTHORIZE

2、D FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL SCC FOREWARD National Standard of Canada A National Standard of Canada is a standard developed by a Standards Council of Canada (SCC) accredited Standards Development Organization, in compliance with requirements and guidance set

3、out by SCC. More information on National Standards of Canada can be found at www.scc.ca. SCC is a Crown corporation within the portfolio of Innovation, Science and Economic Development (ISED) Canada. With the goal of enhancing Canadas economic competitiveness and social well-being, SCC leads and fac

4、ilitates the development and use of national and international standards. SCC also coordinates Canadian participation in standards development, and identies strategies to advance Canadian standardization efforts. Accreditation services are provided by SCC to various customers, including product cert

5、iers, testing laboratories, and standards development organizations. A list of SCC programs and accredited bodies is publicly available at www.scc.ca.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Processed Solid-

6、Fuel Firelogs and Firestarters ANSI/CAN/UL/ULC 2115 Fourth Edition, Dated November 7, 2017 Summary of Topics This is the Fourth Edition of the Standard for Processed Solid-Fuel Firelogs and Firestarters, ANSI/CAN/UL/ULC 2115. The new requirements are substantially in accordance with Proposal(s) on t

7、his subject dated February 3, 2017 and August 4, 2017. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides t

8、his Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of pro

9、ts, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this S

10、tandard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or devi

11、ation introduced while purchaser is storing an electronic Standard on the purchasers computer system. NOVEMBER 7, 2017 ANSI/CAN/UL/ULC 2115 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL NOVEMBER 7, 2017 ANSI/CAN/UL/ULC 2115 tr2 No Text

12、on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL November 7, 2017 1 UL/ULC 2115 Standard for Processed Solid-Fuel Firelogs and Firestarters First Edition February, 1999 Second Edition November, 2007 Third Edition October, 2015 Fou

13、rth Edition November 7, 2017 This ANSI/CAN/UL/ULC Standard for Safety consists of the Fourth edition. The most recent designation of ANSI/UL 2115 as an American National Standard (ANS) occurred on November 7, 2017. ANSI approval for a standard does not include the Cover Page, Transmittal Pages and T

14、itle Page. This standard has been approved as a National Standard of Canada (NSC) by the Standards Council of Canada (SCC). COPYRIGHT 2017 UNDERWRITERS LABORATORIES INC. ANSI/UL 2115-2017UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL NOVEMB

15、ER 7, 2017 PROCESSED SOLID-FUEL FIRELOGS AND FIRESTARTERS - UL/ULC 2115 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS Preface . 4 INTRODUCTION 1 Scope .7 2 Units of Measurement .7 3 Reference Publications 7 4

16、 Glossary .7 5 Compliance 7 PERFORMANCE - FIRELOGS AND FIRESTARTERS 6 Aging Test .8 7 Spontaneous Heating Test .8 8 Heat Release Rate Calorimeter Test 9 MARKINGS - FIRELOGS 9 Firelog Marking and Instructions .10 PERFORMANCE - FIRESTARTERS 10 Ignition and Burn Test .12 11 Liquid Residue Test .12 12 V

17、apour Hazard .12 13 Flash Fire 13 14 Properties Analysis .13 MARKING - FIRESTARTERS 15 Firestarter Markings and Instructions 13 ANNEX A(Informative) A1.1 Reference Standards .A1 NOVEMBER 7, 2017 PROCESSED SOLID-FUEL FIRELOGS AND FIRESTARTERS - UL/ULC 2115 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR

18、FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL Preface This is the Fourth Edition of the Standard for Processed Solid-Fuel Firelogs and Firestarters. This Edition of the Standard has been formally approved by the ULC Standards Committee on Factory-Built Fireplace, Chimneys and Vents

19、 and the UL Standards Technical Panel on Solid-Fuel Burning Appliances. This Standard has been developed in compliance with the requirements of SCC and ANSI for accreditation of a Standards Development Organization. Only metric SI units of measurement are used in this Standard. If a value for measur

20、ement is followed by a value in other units in parentheses, the second value may be approximate. The rst stated value is the requirement. Appendix A, identied as Informative, is for information purposes only. UL is accredited by the American National Standards Institute (ANSI) and the Standards Coun

21、cil of Canada (SCC) as a Standards Development Organization (SDO). ULC Standards is accredited by the Standards Council of Canada (SCC) as a Standards Development Organization (SDO). This ANSI/CAN/UL/ULC 2115 Standard for Safety is under continuous maintenance, whereby each revision is ANSI/CAN appr

22、oved upon publication. If no revisions occur, the initiation of the review of this Standard will commence within 5 years of the date of publication. The review and action to revise or reaffirm this Standard will not exceed 5 years from the date of publication, unless the Standard is identied as ttin

23、g within a stabilized category, whereby the review will commence within the appropriate time frame set out by ULC Standards and Underwriters Laboratories Inc. In Canada, there are two official languages, English and French. All safety warnings must be in French and English. Attention is drawn to the

24、 possibility that some Canadian authorities may require additional markings and/or installation instructions to be in both official languages. This is a Fourth Edition joint National Standard of Canada and American National Standard. Comments or proposals for revisions on any part of the Standard ma

25、y be submitted to UL or ULC at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at http:/. Attention is drawn to the possibility that some of the elements of this joint Canadian and American standard may be the subject of

26、 patent rights. ULC Standards shall not be held responsible for identifying any or all such patent rights. Requests for interpretation of this Standard should be sent to ULC Standards. The requests should be worded in such a manner as to permit a “yes” or “no” answer based on the literal text of the

27、 requirement concerned. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. NOVE

28、MBER 7, 2017 PROCESSED SOLID-FUEL FIRELOGS AND FIRESTARTERS - UL/ULC 2115 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL To purchase UL Standards, visit Comm 2000 at http:/m- or call tollfree 1-888-853-3503. Copies of this joint National S

29、tandard of Canada and American National Standard may also be ordered from ULC Standards. The following lists represents the membership when the nal text in this standard was balloted. Since that time, changes in the membership may have occurred. ULC Standards Committee on Factory-Built Fireplaces, C

30、himneys and Vents Name Representing Interest Category Region J. Wade (Chair) ULC Standards Chair - Non-voting Canada M. Brunt Flexmaster Canada Ltd. Producer Canada M. Byle Stove Parlour and Gallery Inc. User Ontario Q. Choudry Office of the Ontario Fire Marshal Regulator Ontario E. Dufour Security

31、Chimneys International Ltd. Producer Canada G. Faber SCM Risk Management Services General Canada Z. Gadomski Wood Energy Technicians of British Columbia User Canada T. Gottschalk Hearth, Patio and Barbecue Association Canada Producer Canada M. Harwood iv3Cus/iv3 Solutions General Canada J. Herald J

32、B Section 7 - Spontaneous Heating Test; C Section 8 - Heat Release Rate Calorimeter Test; and D Section 9 - Marking - Firelogs. 5.2 Solid fuel re starters shall comply with the requirements of the following Sections of this Standard : A Section 6 - Aging Test; B Section 7 - Spontaneous Heating Test;

33、 C Section 8 - Heat Release Rate Calorimeter Test; NOVEMBER 7, 2017 PROCESSED SOLID-FUEL FIRELOGS AND FIRESTARTERS - UL/ULC 2115 7UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL D Section 10 - Ignition and Burn Test; E Section 11 - Liquid Re

34、sidue Test; F Section 12 - Vapour Hazard; G Section 13 - Flash Fire; H Section 14 - Properties Analysis; and I Section 15 - Marking - Firestarters. PERFORMANCE - FIRELOGS AND FIRESTARTERS 6 Aging Test 6.1 The processed solid-fuel relog/restarter shall remain intact and show no visible signs of degra

35、dation after being subjected to the test described in 6.2 and 6.3. 6.2 Four relogs/restarters are to be placed in a full draft circulating air oven at a temperature of 70C (158F) for 60 days. 6.3 The relogs/restarters are to be removed from the oven after 60 days and visually examined for degradatio

36、n such as cracking, brittleness, or crumbling. 7 Spontaneous Heating Test 7.1 There shall be no evidence of spontaneous heating of the relog/restarter material when tested in accordance with 7.2 7.4. The relogs/restarters used for this test shall be previously conditioned as described in the Aging T

37、est, Section 6. 7.2 The apparatus used for the Spontaneous Heating Test is to consist of a vertical, cylindrical test chamber, 178 mm (7 inches) in height and 102 mm (4 inches) in diameter, surrounded at the side and bottom by an electrically heated water bath. The test chamber is to be provided wit

38、h a cover having two air vent tubes and an opening for introduction of a thermocouple or a maximum registering thermometer. The representative relog/restarter is to be contained within the test chamber by a cylinder of wire gauze, 152 mm (6 inches) in height and 38 mm (1-1/2 inches) in diameter. The

39、 cylinder is to be concentric with the axis of the test chamber and annular space through air of 32 mm (1-1/4 inch) is to exist between the cylinder and the wall of the chamber. 7.3 A minimum 74 g (2.6-oz) crumbled segment from the middle of a relog/restarter is to be prepared. The segment is to con

40、sist of ne particles not larger than 10 mm (3/8 inch) in diameter. The segment is to be loosely placed into the cylinder as described in 7.2, with cheesecloth used to close the bottom. The cylinder is then to be placed in the test chamber and a thermocouple is to be inserted at the center of the segment. The cover is then to be placed on the chamber, and the water bath surrounding the chamber is to be maintained at boiling for a period of 24 h. NOVEMBER 7, 2017 PROCESSED SOLID-FUEL FIRELOGS AND FIRESTARTERS - UL/ULC 2115 8

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1