1、ANSI/AAMI/ISO 14160: 2011Sterilization of health care products Liquid chemical sterilizing agents for single-use medical devices utilizing animal tissues and their derivatives Requirements for characterization, development, validation and routine control of a sterilization process for medical device
2、sAmerican National StandardObjectives and uses of AAMI standards and recommended practices It is most important that the objectives and potential uses of an AAMI product standard or recommended practice are clearly understood. The objectives of AAMIs technical development program derive from AAMIs o
3、verall mission: the advancement of medical instrumentation. Essential to such advancement are (1) a continued increase in the safe and effective application of current technologies to patient care, and (2) the encouragement of new technologies. It is AAMIs view that standards and recommended practic
4、es can contribute significantly to the advancement of medical instrumentation, provided that they are drafted with attention to these objectives and provided that arbitrary and restrictive uses are avoided. A voluntary standard for a medical device recommends to the manufacturer the information that
5、 should be provided with or on the product, basic safety and performance criteria that should be considered in qualifying the device for clinical use, and the measurement techniques that can be used to determine whether the device conforms with the safety and performance criteria and/or to compare t
6、he performance characteristics of different products. Some standards emphasize the information that should be provided with the device, including performance characteristics, instructions for use, warnings and precautions, and other data considered important in ensuring the safe and effective use of
7、 the device in the clinical environment. Recommending the disclosure of performance characteristics often necessitates the development of specialized test methods to facilitate uniformity in reporting; reaching consensus on these tests can represent a considerable part of committee work. When a draf
8、ting committee determines that clinical concerns warrant the establishment of minimum safety and performance criteria, referee tests must be provided and the reasons for establishing the criteria must be documented in the rationale. A recommended practice provides guidelines for the use, care, and/o
9、r processing of a medical device or system. A recommended practice does not address device performance per se, but rather procedures and practices that will help ensure that a device is used safely and effectively and that its performance will be maintained. Although a device standard is primarily d
10、irected to the manufacturer, it may also be of value to the potential purchaser or user of the device as a frame of reference for device evaluation. Similarly, even though a recommended practice is usually oriented towards healthcare professionals, it may be useful to the manufacturer in better unde
11、rstanding the environment in which a medical device will be used. Also, some recommended practices, while not addressing device performance criteria, provide guidelines to industrial personnel on such subjects as sterilization processing, methods of collecting data to establish safety and efficacy,
12、human engineering, and other processing or evaluation techniques; such guidelines may be useful to health care professionals in understanding industrial practices. In determining whether an AAMI standard or recommended practice is relevant to the specific needs of a potential user of the document, s
13、everal important concepts must be recognized: All AAMI standards and recommended practices are voluntary (unless, of course, they are adopted by government regulatory or procurement authorities). The application of a standard or recommended practice is solely within the discretion and professional j
14、udgment of the user of the document. Each AAMI standard or recommended practice reflects the collective expertise of a committee of health care professionals and industrial representatives, whose work has been reviewed nationally (and sometimes internationally). As such, the consensus recommendation
15、s embodied in a standard or recommended practice are intended to respond to clinical needs and, ultimately, to help ensure patient safety. A standard or recommended practice is limited, however, in the sense that it responds generally to perceived risks and conditions that may not always be relevant
16、 to specific situations. A standard or recommended practice is an important reference in responsible decision-making, but it should never replace responsible decision-making. Despite periodic review and revision (at least once every five years), a standard or recommended practice is necessarily a st
17、atic document applied to a dynamic technology. Therefore, a standards user must carefully review the reasons why the document was initially developed and the specific rationale for each of its provisions. This review will reveal whether the document remains relevant to the specific needs of the user
18、. Particular care should be taken in applying a product standard to existing devices and equipment, and in applying a recommended practice to current procedures and practices. While observed or potential risks with existing equipment typically form the basis for the safety and performance criteria d
19、efined in a standard, professional judgment must be used in applying these criteria to existing equipment. No single source of information will serve to identify a particular product as “unsafe“. A voluntary standard can be used as one resource, but the ultimate decision as to product safety and eff
20、icacy must take into account the specifics of its utilization and, of course, cost-benefit considerations. Similarly, a recommended practice should be analyzed in the context of the specific needs and resources of the individual institution or firm. Again, the rationale accompanying each AAMI standa
21、rd and recommended practice is an excellent guide to the reasoning and data underlying its provision. In summary, a standard or recommended practice is truly useful only when it is used in conjunction with other sources of information and policy guidance and in the context of professional experience
22、 and judgment. INTERPRETATIONS OF AAMI STANDARDS AND RECOMMENDED PRACTICES Requests for interpretations of AAMI standards and recommended practices must be made in writing, to the AAMI Vice President, Standards Policy and Programs. An official interpretation must be approved by letter ballot of the
23、originating committee and subsequently reviewed and approved by the AAMI Standards Board. The interpretation will become official and representation of the Association only upon exhaustion of any appeals and upon publication of notice of interpretation in the “Standards Monitor“ section of the AAMI
24、News. The Association for the Advancement of Medical Instrumentation disclaims responsibility for any characterization or explanation of a standard or recommended practice which has not been developed and communicated in accordance with this procedure and which is not published, by appropriate notic
25、e, as an official interpretation in the AAMI News. American National Standard ANSI/AAMI/ISO 14160:2011 (Revision of ANSI/AAMI/ISO 14160:1998/(R)2008) Sterilization of health care products Liquid chemical sterilizing agents for single-use medical devices utilizing animal tissues and their derivatives
26、 Requirements for characterization, development, validation and routine control of a sterilization process for medical devices Approved 10 August 2011 by Association for the Advancement of Medical Instrumentation Approved 5 December 2011 by American National Standards Institute Abstract: Specifies r
27、equirements for the development, validation, process control and monitoring of the sterilization, by the use of liquid chemical sterilants, of single-use medical devices comprising, in whole or in part, materials of animal origin. Keywords: manufacturing, calibration, qualification, process control,
28、 certification, monitoring AAMI Standard This Association for the Advancement of Medical Instrumentation (AAMI) standard implies a consensus of those substantially concerned with its scope and provisions. The existence of an AAMI standard does not in any respect preclude anyone, whether they have ap
29、proved the standard or not, from manufacturing, marketing, purchasing, or using products, processes, or procedures not conforming to the standard. AAMI standards are subject to periodic review, and users are cautioned to obtain the latest editions. CAUTION NOTICE: This AAMI standard may be revised o
30、r withdrawn at any time. AAMI procedures require that action be taken to reaffirm, revise, or withdraw this standard no later than 5 years from the date of publication. Interested parties may obtain current information on all AAMI standards by calling or writing AAMI, or by visiting the AAMI website
31、 at www.aami.org. All AAMI standards, recommended practices, technical information reports, and other types of technical documents developed by AAMI are voluntary, and their application is solely within the discretion and professional judgment of the user of the document. Occasionally, voluntary tec
32、hnical documents are adopted by government regulatory agencies or procurement authorities, in which case the adopting agency is responsible for enforcement of its rules and regulations. Published by Association for the Advancement of Medical Instrumentation 4301 N. Fairfax Drive, Suite 301 Arlington
33、, VA 22203-1633 www.aami.org 2012 by the Association for the Advancement of Medical Instrumentation All Rights Reserved This publication is subject to copyright claims of ISO, ANSI, and AAMI. No part of this publication may be reproduced or distributed in any form, including an electronic retrieval
34、system, without the prior written permission of AAMI. All requests pertaining to this document should be submitted to AAMI. It is illegal under federal law (17 U.S.C. 101, et seq.) to make copies of all or any part of this document (whether internally or externally) without the prior written permiss
35、ion of the Association for the Advancement of Medical Instrumentation. Violators risk legal action, including civil and criminal penalties, and damages of $100,000 per offense. For permission regarding the use of all or any part of this document, complete the reprint request form at www.aami.org or
36、contact AAMI at 4301 N. Fairfax Drive, Suite 301, Arlington, VA 22203-1633. Phone: (703) 525-4890; Fax: (703) 525-1067. Printed in the United States of America ISBN 1-57020-433-0 Contents Page Glossary of equivalent standards vi Committee representation viii Background of AAMI adoption of ISO 14160:
37、2011 ix Foreword v Introduction xi 1 Scope. 1 2 Normative references 2 3 Terms and definitions 2 4 Quality management system elements 6 4.1 Documentation . 6 4.2 Management responsibility . 6 4.3 Product realization . 6 4.4 Measurement, analysis and improvement Control of non-conforming products 7 5
38、 Sterilizing agent characterization . 7 5.1 General 7 5.2 Sterilizing agent . 7 5.3 Microbicidal effectiveness 7 5.4 Effects on materials . 8 5.5 Safety and the environment 8 6 Process and equipment characterization 8 6.1 General 8 6.2 Process characterization 8 6.3 Equipment characterization 9 7 Pr
39、oduct definition 9 8 Process definition 10 8.1 Purpose . 10 8.2 Determination of the inactivation kinetics. 10 8.3 Method for neutralization 11 8.4 Safety quality and performance . 11 9 Validation 11 9.1 General 11 9.2 Installation qualification 12 9.3 Operational qualification . 12 9.4 Performance
40、qualification . 13 9.5 Review and approval of validation . 15 10 Routine monitoring and control . 16 11 Product release from sterilization 17 12 Maintaining process effectiveness 18 12.1 General 18 12.2 Maintenance of equipment 18 12.3 Requalification . 18 12.4 Assessment of change 18 Annex A (infor
41、mative) Guidance for the application of this International Standard 19 Annex B (normative) Determination of lethal rate of the sterilization process . 31 Annex C (informative) Flowchart for microbicidal effectiveness (see 5.3), process definition (see Clause 8), and microbiological performance quali
42、fication (see 9.4.2) . 35 Bibliography 36 2012 Association for the Advancement of Medical Instrumentation ANSI/AAMI/ISO 14160:2011 v Glossary of equivalent standards International Standards adopted in the United States may include normative references to other International Standards. For each Inter
43、national Standard that has been adopted by AAMI (and ANSI), the table below gives the corresponding U.S. designation and level of equivalency to the International Standard. NOTE: Documents are sorted by international designation. The code in the U.S. column, “(R)20xx” indicates the year the document
44、 was officially reaffirmed by AAMI. For example, ANSI/AAMI/ISO 10993-4:2002/(R)2009 indicates that 10993-4, originally approved and published in 2002, was reaffirmed without change in 2009. Other normatively referenced International Standards may be under consideration for U.S. adoption by AAMI; the
45、refore, this list should not be considered exhaustive. International designation U.S. designation Equivalency IEC 60601-1:2005 Technical Corrigendum 1 and 2 ANSI/AAMI ES60601-1:2005 and ANSI/AAMI ES60601-1:2005/A2:2010 ANSI/AAMI ES60601-1:2005/C1:2009 (amdt) Major technical variations C1 Identical t
46、o Corrigendum 1 inevitably this means that there is always a finite probability that a microorganism may survive regardless of the extent of treatment applied. For a given treatment, the probability of survival is determined by the number and resistance of microorganisms and by the environment in wh
47、ich the organisms exist during treatment. It follows that the sterility of any one medical device in a population of items subjected to sterilization processing cannot be guaranteed and the sterility of a processed population is defined in terms of the probability of there being a viable microorgani
48、sm present on a medical device. Attention also has to be given to a number of factors, including the microbiological status (bioburden) of incoming raw materials and/or components and their subsequent storage, and to the control of the environment in which the product is manufactured, assembled and
49、packaged (see also ISO 13485). Requirements for quality management systems for medical device production are given in ISO 13485. The standards for quality management systems recognize that, for certain processes used in manufacturing, the effectiveness of the process cannot be fully verified by subsequent inspection and testing of the product. Sterilization is an example of such a process. For this reason, sterilization processes are validated for use, the performance of the sterilization process is monitored routinely and the equipment is maintained. Animal tissues and th