ANSI ASTM E2555-2007 Standard Practice for Factors and Procedures for Applying the MIL-STD-105 Plans in Life and Reliability Inspection《基于维泊尔分布的寿命和可靠度测试的实施规程和取样程序》.pdf

上传人:arrownail386 文档编号:432635 上传时间:2018-11-11 格式:PDF 页数:24 大小:316.10KB
下载 相关 举报
ANSI ASTM E2555-2007 Standard Practice for Factors and Procedures for Applying the MIL-STD-105 Plans in Life and Reliability Inspection《基于维泊尔分布的寿命和可靠度测试的实施规程和取样程序》.pdf_第1页
第1页 / 共24页
ANSI ASTM E2555-2007 Standard Practice for Factors and Procedures for Applying the MIL-STD-105 Plans in Life and Reliability Inspection《基于维泊尔分布的寿命和可靠度测试的实施规程和取样程序》.pdf_第2页
第2页 / 共24页
ANSI ASTM E2555-2007 Standard Practice for Factors and Procedures for Applying the MIL-STD-105 Plans in Life and Reliability Inspection《基于维泊尔分布的寿命和可靠度测试的实施规程和取样程序》.pdf_第3页
第3页 / 共24页
ANSI ASTM E2555-2007 Standard Practice for Factors and Procedures for Applying the MIL-STD-105 Plans in Life and Reliability Inspection《基于维泊尔分布的寿命和可靠度测试的实施规程和取样程序》.pdf_第4页
第4页 / 共24页
ANSI ASTM E2555-2007 Standard Practice for Factors and Procedures for Applying the MIL-STD-105 Plans in Life and Reliability Inspection《基于维泊尔分布的寿命和可靠度测试的实施规程和取样程序》.pdf_第5页
第5页 / 共24页
点击查看更多>>
资源描述

1、Designation: E2555 07 (Reapproved 2018) An American National StandardStandard Practice forFactors and Procedures for Applying the MIL-STD-105 Plansin Life and Reliability Inspection1This standard is issued under the fixed designation E2555; the number immediately following the designation indicates

2、the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice presents a procedure and related t

3、ables offactors for adapting Practice E2234 (equivalent to MIL-STD-105) sampling plans to acceptance sampling inspection whenthe item quality of interest is life length or reliability. Factorsare provided for three alternative criteria for lot evaluation:mean life, hazard rate, and reliable life. In

4、spection of thesample is by attributes with testing truncated at the end of someprearranged period of time. The Weibull distribution, togetherwith the exponential distribution as a special case, is used asthe underlying statistical model.1.2 A system of units is not specified by this practice.1.3 Th

5、is standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety, health, and environmental practices and deter-mine the applicability of regulatory limitations prior to use.1.4 T

6、his international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trad

7、e (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2E456 Terminology Relating to Quality and StatisticsE2234 Practice for Sampling a Stream of Product by Attri-butes Indexed by AQL2.2 Other Documents:MIL-STD-105E Sampling Procedures and Tables for In-spection by Attributes33. Terminology3.1

8、 Definitions:3.1.1 The terminology defined in Terminology E456 appliesto this practice unless modified herein.3.1.2 acceptance quality level (AQL), nquality limit that isthe worst tolerable process average when a continuing series oflots is submitted for acceptance sampling. E22343.1.2.1 DiscussionT

9、his term is often referred to as the“acceptance quality limit.”3.1.2.2 DiscussionThis definition supersedes that given inMIL-STD-105E.3.1.2.3 DiscussionA sampling plan and an AQL are cho-sen in accordance with the risk assumed. Use of a value ofAQL for a certain defect or group of defects indicates

10、that thesampling plan will accept the great majority of the lots orbatches provided the process average level of percent defective(or defects per hundred units) in these lots or batches are nogreater than the designated value of AQL. Thus, the AQL is adesignated value of percent defective (or defect

11、s per hundredunits) for which lots will be accepted most of the time by thesampling procedure being used. The sampling plans providedherein are so arranged that the probability of acceptance at thedesignated AQL value depends upon the sample size, beinggenerally higher for large samples than for sma

12、ll ones, for agiven AQL. The AQL alone does not identify the chances ofaccepting or rejecting individual lots or batches but moredirectly relates to what might be expected from a series of lotsor batches, provided the steps indicated in this refer to theoperating characteristic curve of the plan to

13、determine therelative risks.1This practice is under the jurisdiction ofASTM Committee E11 on Quality andStatistics and is the direct responsibility of Subcommittee E11.40 on Reliability.Current edition approved April 1, 2018. Published May 2018. Originallyapproved in 2007. Last previous version appr

14、oved in 2012 as E2555 07 (2012).DOI: 10.1520/E2555-07R18.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3MIL

15、-STD-105E is also commonly referred to as “MIL-STD-105.” It is virtuallyidentical in content to its predecessor, MIL-STD-105D. These documents are out ofprint.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard

16、was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.13.1.3 cons

17、umers risk, nprobability that a lot havingspecified rejectable quality level will be accepted under adefined sampling plan.3.1.4 double sampling plan, na multiple sampling plan inwhich up to two samplings can be taken and evaluated toaccept or reject a lot.3.1.5 limiting quality level (LQL), nqualit

18、y level having aspecified consumers risk for a given sampling plan.3.1.6 lot, na definite quantity of a product or materialaccumulated under conditions that are considered uniform forsampling purposes.3.1.6.1 DiscussionThe lot for sampling may differ from acollection of units designated as a batch f

19、or other purposes, forexample, production, shipment, and so forth.3.1.7 multiple sampling plan, na sampling plan in whichsuccessive samples from a lot are drawn and after each sampleis inspected a decision is made to accept the lot, reject the lot,or to take another sample, based on quality level of

20、 thecombined samples.3.1.7.1 DiscussionWhen the quality is much less or muchmore than the AQL, the decision can be made on the firstsample, which is smaller than that of a single sampling planwith equivalent acceptance quality level. For samples that areclose to theAQLin quality, additional samples

21、are required andthe total sample size will be larger than the correspondingsingle sampling plan.3.1.8 sample, ngroup of items, observations, test results,or portions of material taken from a large collection of items,observations, test results, or quantities of material that serves toprovide informa

22、tion that may be used as a basis for making adecision concerning the larger collection. E22343.2 Definitions of Terms Specific to This Standard:3.2.1 acceptance number, nthe maximum number offailed items allowed in the sample for the lot to be acceptedusing a single or multiple sampling plan.3.2.2 h

23、azard rate, ndifferential fraction of items failing attime t among those surviving up to time t, symbolized by h(t).3.2.2.1 Discussionh(t) is also referred to as the instanta-neous failure rate at time t. It is related to the probabilitydensity and cumulative distribution functions by h(t) = f(t)/(l

24、 F(t).3.2.3 mean life, naverage time that items in the lot orpopulation are expected to operate before failure.3.2.3.1 DiscussionThis metric is often referred to as meantime to failure (MTTF) or mean time before failure (MTBF).3.2.4 rejection number, nthe minimum number of faileditems in the sample

25、that will cause the lot to be rejected undera given sampling plan.3.2.5 reliable life (r), nlife beyond which some specifiedproportion, r, of the items in the lot or population will survive.3.2.6 test truncation time (t), namount of time sampleditems are allowed to be tested.3.2.7 Weibull distributi

26、on, nprobability distribution hav-ing cumulative distribution:function Ft! 5 1 2 expS2St 2 DD, t. and probability densityfunction ft! 5St 2 D21expS2St 2 DD3.2.7.1 DiscussionThe Weibull distribution is widely usedfor modeling product life. It can take a wide variety of shapesand also the characterist

27、ics of other types of distributions basedon the value of its parameters. is called the location,minimum life, or threshold parameter and defines the lowerlimit of the distribution (Fig. 1). is called the scale orFIG. 1 Effect of the Parameter on the Weibull Probability Den-sity Function, f(t)E2555 0

28、7 (2018)2characteristic life parameter and is equal to the 63.2 percentileof the distribution, minus (Fig. 2). is the shape parameter(Fig. 3). The exponential distribution is the special case where = 0 and =l.4. Significance and Use4.1 The procedure and tables presented in this practice arebased on

29、the use of the Weibull distribution in acceptancesampling inspection. Details of this work, together with tablesof sampling plans of other forms, have been published previ-ously. See Refs (1-3).4Since the basic computations requiredhave already been made, it has been quite easy to provide thesenew f

30、actors. No changes in method or details of applicationhave been made over those described in the publicationsreferenced above. For this reason, the text portion of this reporthas been briefly written. Readers interested in further detailsare referred to these previous publications. Other sources ofm

31、aterial on the underlying theory and approach are alsoavailable (4-7).4.2 The procedure to be used is essentially the same as theone normally used for attribute sampling inspection. The onlydifference is that sample items are tested for life or survivalinstead of for some other property. For single

32、sampling, thefollowing are the required steps:4.2.1 Using the tables of factors provided in Annex A1,select a suitable sampling inspection plan from those tabulatedin Practice E2234.4.2.2 Draw at random a sample of items of the size specifiedby the selected Practice E2234 plan.4.2.3 Place the sample

33、 of items on life test for the specifiedperiod of time, t.4.2.4 Determine the number of sample items that failedduring the test period.4.2.5 Compare the number of items that failed with thenumber allowed under the selected Practice E2234 plan.4.2.6 If the number that failed is equal to or less than

34、theacceptable number, accept the lot; if the number failingexceeds the acceptable number, reject the lot.4.3 Both the sample sizes and the acceptance numbers usedare those specified by Practice E2234 plans. It will be assumedin the section on examples that single sampling plans will beused. However,

35、 the matching double sampling and multiplesampling plans provided in MIL-STD-105 can be used ifdesired. The corresponding sample sizes and acceptance andrejection numbers are used in the usual way. The specified testtruncation time, t, must be used for all samples.4.4 The probability of acceptance f

36、or a lot under thisprocedure depends only on the probability of a sample itemfailing before the end of the test truncation time, t. For thisreason, the actual life at failure need not be determined; onlythe number of items failing is of interest. Life requirements andtest time specifications need no

37、t necessarily be measured inchronological terms such as minutes or hours. For example, thelife measure may be cycles of operation, revolutions, or milesof travel.4.5 The underlying life distribution assumed in this standardis the Weibull distribution (note that the exponential distribu-tion is a spe

38、cial case of the Weibull). The Weibull model hasthree parameters. One parameter is a scale or characteristic lifeparameter. For these plans and procedures, the value for thisparameter need not be known; the techniques used are inde-pendent of its magnitude. A second parameter is a location or“guaran

39、teed life” parameter. In these plans and procedures, it isassumed that this parameter has a value of zero and that thereis some risk of item failure right from the start of life. If this isnot the case for some applications, a simple modification inprocedure is available. The third parameter, and th

40、e one of4The boldface numbers in parentheses refer to the list of references at the end ofthis standard.FIG. 2 Effect of the Parameter on the Weibull Probability Den-sity Function, f(t)E2555 07 (2018)3importance, is the shape parameter, .5The magnitude of theconversion factors used in the procedures

41、 described in thisreport depends directly on the value for this parameter. For thisreason, the magnitude of the parameter shall be known throughexperience with the product or shall be estimated from pastresearch, engineering, or inspection data. Estimation proce-dures are available and are outlined

42、in Ref (1).4.6 For the common case of random chance failures with thefailure rate constant over time, rather than failures as a result of“infant mortality” or wearout, a value of 1 for the shapeparameter shall be assumed. With this parameter value, theWeibull distribution reduces to the exponential.

43、 Tables ofconversion factors are provided in Annex A1 for 15 selectedshape parameter values ranging from12 to 10, the rangecommonly encountered in industrial and technical practice.The value 1, used for the exponential case, is included. Factorsfor other required shape parameter values within this r

44、angemay be obtained approximately by interpolation. A morecomplete discussion of the relationship between failure pat-terns and the Weibull parameters can be found in Refs (1-3).4.7 One possible acceptance criterion is the mean life foritems making up the lot (). Mean life conversion factors orvalue

45、s for the dimensionless ratio 100t/ have been determinedto correspond to or replace all the p or percent defective valuesassociated with Practice E2234 plans. In this factor, t repre-sents the specified test truncation time and the mean item lifefor the lot. For reliability or life-length applicatio

46、ns, thesefactors are used in place of the corresponding p valuesnormally used in the use of Practice E2234 plans for attributeinspection of other item qualities. The use of these factors willbe demonstrated by several examples (see Sections 5, 7, and 9).4.8 Annex Table 1A lists, for each selected sh

47、ape parametervalue, 100t/ ratios for each of the Practice E2234 AQLp(%) values. With acceptance inspection plans selected interms of these ratios, the probability of acceptance will be highfor lots whose mean life meets the specified requirement. Theactual probability of acceptance will vary from pl

48、an to plan andmay be read from the associated operating characteristic curvessupplied in MIL-STD-105. The curves are entered by using thecorresponding p(%) value. Annex Table 1B lists 100t/ ratiosat the LQL for the quality level at which the consumers risk is0.10. Annex Table 1C lists corresponding

49、100t/ ratios for aconsumers risk of 0.05.4.8.1 These ratios are to be used directly for the usual casefor which the value for the Weibull location or thresholdparameter () can be assumed as zero. If is not zero but hassome other known value, all that shall be done is to subtract thevalue for from t to get t0and from m to get m0. Thesetransformed values, t0and m0, are then employed in the use ofthe tables and for all other computations.Asolution in terms ofm0and t0can then be converted back to actual or

展开阅读全文
相关资源
  • ANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdfANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdf
  • ANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdfANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdf
  • ANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdfANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdf
  • ANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdfANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdf
  • ANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdfANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdf
  • ANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdfANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdf
  • ANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdfANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdf
  • ANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdfANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdf
  • ANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdfANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdf
  • ANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdfANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ANSI

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1