ANSI ASTM F1365-1991 Standard Test Method for Water Infiltration Resistance of Plastic Underground Conduit Joints Which Use Flexible Elastomeric Seals《采用柔性合成橡胶密封件的塑料地下管道接头耐水渗透性试验方法.pdf

上传人:刘芸 文档编号:432817 上传时间:2018-11-11 格式:PDF 页数:3 大小:100.42KB
下载 相关 举报
ANSI ASTM F1365-1991 Standard Test Method for Water Infiltration Resistance of Plastic Underground Conduit Joints Which Use Flexible Elastomeric Seals《采用柔性合成橡胶密封件的塑料地下管道接头耐水渗透性试验方法.pdf_第1页
第1页 / 共3页
ANSI ASTM F1365-1991 Standard Test Method for Water Infiltration Resistance of Plastic Underground Conduit Joints Which Use Flexible Elastomeric Seals《采用柔性合成橡胶密封件的塑料地下管道接头耐水渗透性试验方法.pdf_第2页
第2页 / 共3页
ANSI ASTM F1365-1991 Standard Test Method for Water Infiltration Resistance of Plastic Underground Conduit Joints Which Use Flexible Elastomeric Seals《采用柔性合成橡胶密封件的塑料地下管道接头耐水渗透性试验方法.pdf_第3页
第3页 / 共3页
亲,该文档总共3页,全部预览完了,如果喜欢就下载吧!
资源描述

1、Designation: F1365 91 (Reapproved 2013)Standard Test Method forWater Infiltration Resistance of Plastic UndergroundConduit Joints Which Use Flexible Elastomeric Seals1This standard is issued under the fixed designation F1365; the number immediately following the designation indicates the year oforig

2、inal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the waterinfiltrat

3、ion resistance of gasketed plastic underground conduitjoints using a pressurized water bladder apparatus.1.2 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not

4、considered standard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to

5、 use.2. Referenced Documents2.1 ASTM Standards:2D618 Practice for Conditioning Plastics for TestingD2122 Test Method for Determining Dimensions of Ther-moplastic Pipe and FittingsF512 Specification for Smooth-Wall Poly(Vinyl Chloride)(PVC) Conduit and Fittings for Underground Installation2.2 Underwr

6、iters Laboratories (UL) Standard:UL 651 Schedule 40 and 80 Rigid PVC Conduit32.3 National Electrical Manufacturers Association (NEMA)Standards:TC-2 Electrical Plastic Tubing (EPT) and Conduit (EPC-40and EPC-80)4TC-6 PVC and ABS Plastic Utilities Duct for UndergroundInstallation4TC-8 Extra-Strength P

7、VC Plastic Utilities Duct for Under-ground Installation43. Significance and Use3.1 Underground electrical and communication conduitshould be impervious to groundwater in order to preventdamage to conductors and utility vaults. The bladder testdescribed in this test method may be used to qualify pote

8、ntialgasketed conduit systems by indicating whether the jointsystem will prevent water infiltration.3.2 This test method can be used to qualify joints for plasticunderground conduits using flexible elastomeric seals.However, it should not be assumed that a joint system thatpasses this test method wi

9、ll be able to seal under cases ofmisinstallation or abuse, or both.3.3 This test method covers all of the following gasketedconduit types: encased burial (EB) excluding EB20, directburial (DB), telecommunications, cable television, and Sched-ule 40 conduit and Schedule 80 conduit. Trade sizes covere

10、dare 2-in. nominal size and larger. (See UL 651; NEMA TC-2,TC-6, and TC 8; and Specification F512.)3.4 This test method also covers fittings that are intended foruse with the conduit types described in 3.3 and which useflexible elastomeric seals.4. Apparatus4.1 GeneralOne type of bladder joint teste

11、r is shown inFig. 1.4.2 Bladder:4.2.1 The bladder shall be similar to that shown in Fig. 1.The bladder shall be comprised of a reinforced elastomerictube that is capable of providing a watertight capsule aroundthe subject joint specimen.4.2.2 The bladder shall be able to safely contain an internalwa

12、ter pressure of at least 11.0 psi (75 kPa).4.2.3 The bladder shall have plumbing connections thatallow the bladder to be pressurized with water and that allowtrapped air to be bled out of the bladder.4.2.4 The bladder shall have a pressure gage that indicatespressure in the bladder. This gage shall

13、be capable of measur-ing 11 psi (75 kPa) (gage) with an accuracy of 60.5 psi (63.5kPa) (gage).1This test method is under the jurisdiction of ASTM Committee F17 on PlasticPiping Systems and is the direct responsibility of Subcommittee F17.40 on TestMethods.Current edition approved Aug. 1, 2013. Publi

14、shed October 2013. Originallyapproved in 1991. Last previous edition approved in 2009 as F1365 91(2009) DOI:10.1520/F1365-91R13.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume informatio

15、n, refer to the standards Document Summary page onthe ASTM website.3Available from Underwriters Laboratories (UL), 333 Pfingsten Rd.,Northbrook, IL 60062-2096, http:/.4Available from National Electrical Manufacturers Association (NEMA), 1300N. 17th St., Suite 1752, Rosslyn, VA 22209, http:/www.nema.

16、org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States14.3 Support Fixture:4.3.1 The support fixture shall constrain movement of thetest specimen and bladder during testing.4.3.2 The support fixture shall be capable of axially deflect-in

17、g the joint specimen about the joint to the maximumdeflection angle recommended by the joint manufacturer.NOTE 1Axial deflection of a gasketed pipe joint will also inducediametric deformation of the bell and spigot if the angle of axial deflectionis large enough. This can be beneficial when evaluati

18、ng the sealing abilityof a gasketed pipe joint.5. Test Specimens5.1 The gasketed joint specimen shall be comprised of agasketed bell and a spigot with a chamfer on the outsidediameter edge. Both the bell and spigot shall be of sufficientlength to extend out beyond the bladder enough to provide amean

19、s by which to attach the specimen/bladder assembly to thesupport fixture.5.2 Bell specifications and spigot chamfer specificationsshall be determined by the manufacturer, but the specimensshall be representative of normal and customary production bythe manufacturer. (See Test Method D2122.)5.3 Three

20、 specimens shall be tested for each size of gas-keted conduit.6. Conditioning6.1 Condition specimens for at least2hinairatatemperature of 73.4 6 3.6F (23 6 2C) and conduct the testin a room maintained at the same temperature. (See PracticeD618.)7. Procedure7.1 Select and condition three sets of gask

21、eted bells andspigots of the same nominal size according to Sections 5 and 6of this test method.7.2 Mark the specimens with consecutive numbers, startingwith “1” and ending with “3.”7.3 Select a bell/spigot pair and apply a joint lubricantrecommended by the conduit manufacturer to both the bell ands

22、pigot according to the lubricant manufacturers directions.7.4 Insert the spigot into the bell until the insertion line onthe spigot is flush with the bell lip.7.5 Slide the bladder over the assembled conduit joint andcenter the bladder over the joint seam. Seal the ends of thebladder to the spigot a

23、nd bell.NOTE 2The type of clamps used to seal the bladder to the specimenand the location of the clamps on the specimen may influence the amountof bell and spigot deformation when the joint is deflected axially.7.6 Attach all plumbing in accordance with 4.2.3 and 4.2.4to the bladder assembly.7.7 Att

24、ach the bladder/specimen assembly to the test fixturein a horizontal, axially straight position.7.8 Fill the bladder with water and bleed off trapped air. Donot allow the bladder to pressurize past 5 psi (34 kPa) duringthe filling and air bleeding of the bladder.7.9 After all air is bled from the bl

25、adder, pressurize thebladder to 11 psi (75 kPa) and allow the bladder pressure tostabilize for 5 min.7.10 After the stabilization period, make the necessaryadjustments to the bladder pressure to return it to 11.0 6 0.5psi (75 6 3.5 kPa).7.11 Check for water leakage inside specimen. Leakage atthis po

26、int constitutes failure of the test.7.12 Visually check for leakage of the joint at 5, 10, and15-min intervals. If leakage is detected at any interval, discon-tinue the test. Any leakage constitutes a failure of the test.7.13 If no leakage has occurred to this point, repeat 7.12after axially misalig

27、ning the same joint to the maximumamount allowed by the joint manufacturer.7.14 Any leakage during any part of the test constitutesfailure of the test and the test may be suspended at that point.7.15 Repeat 7.3 through 7.14 for the remaining joints.7.16 If other sizes of conduit are to be tested, re

28、peat 7.1through 7.15.8. Report8.1 Each test of a nominal size of conduit (three specimens)shall generate a test report.8.2 The test report shall include the following:8.2.1 Identification of the bell and spigot specimens used inthe test, including nominal size, type of conduit, material ofmanufactur

29、e, type and source of gasket, and the name of thejoint manufacturer.FIG. 1 Bladder Test ApparatusF1365 91 (2013)28.2.2 Whether the joint passed or failed the test. If the jointfailed, state at what point in the test failure occurred.8.2.3 Date(s) of testing.8.2.4 Location of testing.8.2.5 Name(s) of

30、 personnel conducting test.8.2.6 Comments, if appropriate.9. Precision and Bias9.1 No statement is made about either the precision or biasof this test method for determining water infiltration resistancesince the result merely states whether there is conformance tothe criteria for success specified

31、in the procedure.10. Keywords10.1 bladder; gasketed conduit; underground conduit; waterinfiltrationASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentionedin this standard. Users of this standard are expressly advised that deter

32、mination of the validity of any such patent rights, and the riskof infringement of such rights, are entirely their own responsibility.This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years andif not revised, either reapproved or

33、withdrawn. Your comments are invited either for revision of this standard or for additional standardsand should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of theresponsible technical committee, which you may attend. If you feel that

34、 your comments have not received a fair hearing you shouldmake your views known to the ASTM Committee on Standards, at the address shown below.This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,United States. Individual reprints (

35、single or multiple copies) of this standard may be obtained by contacting ASTM at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.org). Permission rights to photocopy the standard may also be secured from the Copyright Clearance Center, 222Rosewood Drive, Danvers, MA 01923, Tel: (978) 646-2600; http:/ 91 (2013)3

展开阅读全文
相关资源
  • ANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdfANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdf
  • ANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdfANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdf
  • ANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdfANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdf
  • ANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdfANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdf
  • ANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdfANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdf
  • ANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdfANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdf
  • ANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdfANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdf
  • ANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdfANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdf
  • ANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdfANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdf
  • ANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdfANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ANSI

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1