1、Designation: F2521 09 (Reapproved 2014) An American National StandardStandard Specification forHeavy-Duty Ranges, Gas and Electric1This standard is issued under the fixed designation F2521; the number immediately following the designation indicates the year oforiginal adoption or, in the case of rev

2、ision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers heavy-duty ranges that use gasor electrical heat sources, or both, for co

3、oking food in thecommercial and institutional food service establishments.1.2 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.3 This st

4、andard may involve hazardous materials,operations, and equipment. This standard does not purport toaddress all of the safety concerns, if any, associated with itsuse. It is the responsibility of the user of this standard toestablish appropriate safety and health practices and deter-mine the applicab

5、ility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D3951 Practice for Commercial PackagingF760 Specification for Food Service Equipment ManualsF1166 Practice for Human Engineering Design for MarineSystems, Equipment, and FacilitiesF1275 Test Method for Performanc

6、e of GriddlesF1496 Test Method for Performance of Convection OvensF1521 Test Methods for Performance of Range Tops2.2 ANSI Standards:3ANSI B1.1 Unified Inch Screw Threads (UN and UNRThread Form)ANSI Z1.4 Sampling Procedures and Tables for Inspectionby AttributesANSI Z21.41/CSA 6.9 Quick-Disconnect D

7、evices for UseWith Gas Fuel AppliancesANSI Z21.45 Flexible Connector of Other Than All-MetalConstruction for Gas AppliancesANSI Z83.11/CGA-1.8 Gas Food Service Equipment2.3 NSF Standard:4NSF/ANSI 4 Commercial Cooking, Rethermalization andPowered Hot Food Holding and Transport Equipment2.4 NFPA Stand

8、ard:5NFPA 70/ANSI Z223 National Electrical CodeNFPA 54/ANSI Z223 National Fuel Gas Code2.5 UL Standard:6UL/ANSI 197 Commercial Electrical Cooking Appliances2.6 Military Standards:7MIL-STD-167/1 Mechanical Vibration of Shipboard Equip-ment (Type 1Environmental and Type 2InternallyExcited)MIL-STD-461

9、Requirements for the Control of Electromag-netic Characteristics of Subsystems and EquipmentMIL-STD-1399/300 Interface Standard for Shipboard Sys-tems Section 300A Electric Power, Alternating Current3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 broiler, nopen cast iron or st

10、eel grate on which foodis laid, allowing highly directional intense heat under the grateto cook the food. Another type is an overfired heat source,using highly directional intense heat over the food.3.1.2 convection oven, nas used in this specification,adevice that combines the function of circulati

11、ng hot convectionair in an enclosed cavity by means of a fan or blower, which isoperated by an electric motor, for the purpose of baking orroasting food.3.1.3 cook-top electric element, nopen coil electrical ele-ments supported to withstand the weight of filled cookingutensils in direct contact with

12、 the burners.1This specification is under the jurisdiction of ASTM Committee F26 on FoodService Equipment and is the direct responsibility of Subcommittee F26.02 onCooking and Warming Equipment.Current edition approved April 1, 2014. Published May 2014. Originallyapproved in 2005. Last previous edit

13、ion approved in 2009 as F2521 09. DOI:10.1520/F2521-09R14.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Av

14、ailable from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036.4Available from NSF International, P.O. Box 130140, 789 N. Dixboro Rd., AnnArbor, MI 48113-0140.5Available from National Fire Protection Association (NFPA), 1 BatterymarchPark, Quincy, MA 02269-91

15、01.6Available from Underwriters Laboratories (UL), Corporate Progress, 333Pfingsten Rd., Northbrook, IL 60062.7Available from Standardization Documents Order Desk, DODSSP, Bldg. 4,Section D, 700 Robbins Ave., Philadelphia, PA 19111-5098, or from AcquisitionStreamlining and Standardization Informatio

16、n System (ASSIST) located at http:/dsp.dla.mil.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States13.1.4 French top, nsheathed electric burner with perma-nent cover over entire heating element; round and sealed to therange top to resist d

17、rips and splash.3.1.5 griddle, ndevice for cooking food by direct contactwith a hot surface.3.1.6 heavy-duty range, nappliance used for pot or pansurface cooking, griddling, frying, broiling, steaming, baking,roasting, and reheating food products with a standard oven orconvection oven. It is of the

18、most durable construction, varyingin size, offers increased heat input than medium (restaurant) orspecialty ranges. Typical industry widths are 32 in. (812 mm),34 in. (863 mm), and 36 in. (914 mm) for gas range tops andfor electric ranges. The top cooking surface can be13,23,orfull top options of an

19、y style noted. For purposes ofconvenience, nominal dimensions for each width will be usedin this specification.3.1.7 hot top, nflat cast iron surface sometimes called a“boiling plate” or “uniform heat top” with heat transferredfrom gas burners or electric heating elements under thecooking surface wh

20、ere pots are set to warm or keep hot foodcontained in the utensil.3.1.8 open top gas burner, nalso called grate top; has acast iron or steel burner top that supports the pot above the gasburner.3.1.9 standard oven, nas used in this specification, a spacewhere food is baked or roasted without recircu

21、lating air.4. Classification4.1 Type:4.1.1 Type IElectric range top with electric oven.4.1.2 Type IElectric range top with gas-fired oven.4.1.3 Type IElectric range top with storage base.4.1.4 Type IIGas-fired range top with gas-fired oven.4.1.5 Type IIGas-fired range top with electric oven.4.1.6 Ty

22、pe IIGas-fired range top with storage base.Type I Style, Electric RangesDimensions4.2 Widths:84.2.1 32 in. (812 mm)4.2.2 34 in. (863 mm)4.2.3 36 in. (914 mm)4.2.4 HeightsTypically 37 in. (939 mm) from floor towork surface.4.2.5 DepthTypically 37 in. (939 mm) to 41 in. (1040mm).4.3 Electrical Class:4

23、.3.1 Class 1208 V, 60 Hz, 1 phase.4.3.2 Class 2208 V, 60 Hz, 3 phase.4.3.3 Class 3240 V, 60 Hz, 1 phase.4.3.4 Class 4240 V, 60 Hz, 3 phase.4.3.5 Class 5480 V, 60 Hz, 3 phase.4.3.6 Class 6120 V, 60 Hz, 1 phase.4.3.7 Class 7230 V, 50 Hz, 1 phase.4.3.8 Class 8400 V, 50 Hz, 3 phase.4.3.9 Class 9440 V, 6

24、0 Hz, 3 phase (shipboard use).4.4 Cook Top Options4.4.1 Electric Griddles:4.4.1.113 top cover rated nominal 5 kW,23 other topoptions.4.4.1.212 top cover rated nominal 10 kW,12 other topoptions.4.4.1.3 Full top cover rated nominal 10 to 15 kW (Fig.A1.24).4.4.1.423 top cover rated nominal 10 kW (Fig.

25、A1.25).4.4.2 Electric Hot Tops (also known as Boiling Tops, Uni-form Heat Tops)Specify with or without thermostat.4.4.2.113 top cover rated nominal 5 kW,23 other topoptions.4.4.2.212 top cover rated nominal 10 kW,12 other topoptions.4.4.2.3 Full top cover rated nominal 10 to 15 kW (Fig.A1.21).4.4.2.

26、423 top cover rated nominal 10 kW (Fig. A1.22).4.4.3 Open Top Electric Element Burner:4.4.3.1 912-in. (241-mm) diameter closed element (Frenchtop) full cook top rated nominal kW each (Fig. A1.23).4.4.3.2 912-in. (241-mm) diameter open element cook toprated at nominal kW.4.4.4 Additional Electric Ran

27、ge Cook Top Options forElectric RangesAny combination of top cook devices in13,12,23, or full top coverage.4.4.4.1 Three hot tops with or without thermostat.4.4.4.2 Two hot tops and two 9-in. (229 mm) diameterFrench style electric burners.4.4.4.3 Two hot tops and two 9-in. (229 mm) diameter opentop

28、element burners.4.4.4.4 Six 9-in. (229 mm) diameter French stle electricelement burners.4.4.4.5 Six 9-in. (229 mm) diameter open top elementburners.4.4.4.613,12,23, or full top coverage with griddle.4.4.4.713 griddle, 4-top cook elements or hot tops.4.4.4.812 griddle 2-top cook elements or hot topsN

29、OTE 1All open top burners, French top burners, hot tops andgriddles may have temperature controls.4.4.4.9 With or without electric or gas oven (see 4.5 and4.11).4.5 Electric Ovens:4.5.1 Electric Standard Oven7.0 kW or greater.4.5.2 Electric Convection Oven7.0 kW or greater.Type II Style, Gas-Fired R

30、angesDimensions4.6 Widths:84.6.1 32 in. (812 mm)4.6.2 34 in. (863 mm)4.6.3 36 in. (914 mm) are typical4.6.4 HeightsTypically 37 in. (939 mm) from floor towork surface.8Tops can be either a full top of one type of cook top such as a griddle or dividedin sections with one or two or three cook top styl

31、es. Depending on range width, afull top and two sections for 32 and 34-in. (813 and 864-mm) widths and one, two,or three sections on 36-in. (914-mm) range tops.F2521 09 (2014)24.6.5 DepthTypically 37 in. (939 mm) to 41 in. (1040mm).4.7 Power:4.7.1 Natural gas.4.7.2 Propane.4.7.3 Manufactured gas.4.7

32、.4 Other gases (see 5.2.2).4.8 Gas-Fired Cook Top Options:4.8.113 range top. (Fig. A1.13).4.8.212 range top (Fig. A1.11).4.8.323 range top (Fig. A1.14).4.8.4 Full range top (Fig. A1.16).NOTE 2Griddle thickness may range from38 to 1.0 in. (9.5 to 25 mm)and should be specified.4.9 Hot Tops (also known

33、 as Boiling Tops, Uniform HeatTops):4.9.113 range top and23 other cook surface.4.9.212 range top and12 other cook surface (Fig. A1.2).4.9.323 range top and13 other cook surface.4.9.4 Full range top (Fig. A1.1).4.9.512 range top in horizontal top with open burners infront.4.10 Open Top Burners:4.10.1

34、13 range top and23 other cook surface (Fig. A1.13).4.10.212 range top and12 other cook surface (Figs. A1.9-A1.12).4.10.323 range top and13 other cook surface (Fig. A1.14).4.10.4 Full range top (Figs. A1.5-A1.8).4.10.512 range top in horizontal top with open burners infront (Fig. A1.11).4.11 Ovens:4.

35、11.1 Gas-Fired Standard Oven22 000 to 50 000 Btu/h(6.45 to 14.66 KW).4.11.2 Gas-Fired Convection Oven22 000 to 40 000 Btu/h(6.45 to 11.73 KW).4.12 Additional Gas Range Cook Top Options for GasRanges:4.12.1 Graduated hot top or radial fin burners; 1, 2, or 3concentric burner rings. Can be one center

36、location on rangetop or two locations, or two locations to front with hot tops aback of range top (Figs. A1.1 and A1.2).4.12.2 Graduated hot tops can be substituted for open topburners (Fig. A1.4) and have hot top plates in back.5. Ordering Information5.1 An order for a heavy-duty range(s) under thi

37、s specifi-cation shall specify:5.1.1 ASTM specification number and date of issue,5.1.2 Quantity to be furnished,5.1.3 Class,5.1.4 Style (references to figures is helpful), and5.1.5 Size.5.2 Additionally, the following options should be reviewedfor inclusion in the order:5.2.1 When Federal/Military p

38、rocurement(s) is involved,refer to the supplement pages.5.2.2 Type of Gas, as applicableNatural, propane, orwhen “other,” specify high heating value in BTU per hour,specific gravity, and composition of gas.5.2.3 Electrical Power Connection, if applicablePowercord with plug or conduit connection and

39、size (that is, hardwired).5.2.4 Fan Speed (convection ovens only)Single speed ortwo speed.5.2.5 Type of ControlsElectromechanical, solid state, orprogrammable/computer controlled.5.2.6 Interior Finish (convection ovens only)Porcelainenamel or stainless steel.5.2.7 When specified, with a quick-discon

40、nect gas supply,an approved quick disconnect (socket and plug) conforming toANSI Z21.41, and a flexible metal connector conforming toANSI Z21.45 and consisting of a male pipe thread fitting onone end and a union with female thread on the opposite endshall be provided with the convection oven.5.2.8 O

41、ther than the manufacturers standard, commercialand domestic packaging is required. Specify packaging re-quirements.5.2.9 When specified, a certification to ensure that samplesrepresenting each lot have been either tested or inspected asdirected and the requirements have been met. When specified,a c

42、opy of the certification or test results, or both, shall befurnished to the purchaser.5.2.10 When specified, additional options such as wireshelves, casters, oven stand, wash-down hose assembly, andfaucets shall be provided.5.2.11 Manufactured gas or overseas specified gas (may beother than CE gasse

43、s) are to be considered to be a specialrequirement and, if available, may be additional cost and mayinclude a non-standard gas train.5.2.12 Griddles shall be hot-rolled steel.5.2.13 When specified, surface finish other than manufac-turer finish shall be provided.5.2.14 Hot tops can be hot-rolled ste

44、el.6. Materials and Manufacture6.1 GeneralConvection ovens shall conform to the appli-cable documents listed in Section 2. Materials used shall befree from defects which would affect the performance ormaintainability of individual components or of the overallassembly. Materials not specified in this

45、 specification shall beof the same quality used for the intended purpose in commer-cial practice. Unless otherwise specified in this specification,all equipment, material, and articles incorporated in the workcovered by this specification are to be new or fabricated, usingmaterials produced from rec

46、overed materials to the maximumextent possible without jeopardizing the intended use. None ofthe above shall be interpreted to mean that the use of used orrebuilt products is allowed under this specification unlessotherwise specified.6.2 Hardware and FittingsUnless otherwise specified (seeSection 4)

47、, all hardware and fittings shall be corrosion resistantor suitably processed to resist corrosion in accordance with themanufacturers standard practice.F2521 09 (2014)36.3 Threaded PartsAll threaded parts shall conform toANSI B1.1.6.4 Service ConnectionsProvisions for service shall beprovided in the

48、 back or bottom of the convection oven. Accessto shut off gas valves and the like shall be from the front of therange.6.5 Electrical CharacteristicsAll electric elements shallbe designed for operation on nominal voltage ratings,frequency, and phases as specified by electrical Class (see 4.3).Access

49、to circuit breakers, fuses, and the like shall be from thefront of the range.6.6 Oven DoorProvisions shall be made to limit drippingwhen opened. Gasket, when provided, shall be replaceablewithout the use of tools of any type.6.7 Oven Fan and BaffleA motor-operated fan or blowershall be provided to ensure forced air circulation within theoven cavity. A single-speed or two-speed motor shall operatefan. Air baffle may be provided to maintain uniformity oftemperature within the oven cavity.

展开阅读全文
相关资源
  • ANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdfANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdf
  • ANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdfANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdf
  • ANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdfANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdf
  • ANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdfANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdf
  • ANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdfANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdf
  • ANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdfANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdf
  • ANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdfANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdf
  • ANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdfANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdf
  • ANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdfANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdf
  • ANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdfANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ANSI

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1