ANSI ASTM F431-2004 Standard Specification for Air Performance Measurement Plenum Chamber for Vacuum Cleaners.pdf

上传人:tireattitude366 文档编号:433256 上传时间:2018-11-11 格式:PDF 页数:11 大小:538.84KB
下载 相关 举报
ANSI ASTM F431-2004 Standard Specification for Air Performance Measurement Plenum Chamber for Vacuum Cleaners.pdf_第1页
第1页 / 共11页
ANSI ASTM F431-2004 Standard Specification for Air Performance Measurement Plenum Chamber for Vacuum Cleaners.pdf_第2页
第2页 / 共11页
ANSI ASTM F431-2004 Standard Specification for Air Performance Measurement Plenum Chamber for Vacuum Cleaners.pdf_第3页
第3页 / 共11页
ANSI ASTM F431-2004 Standard Specification for Air Performance Measurement Plenum Chamber for Vacuum Cleaners.pdf_第4页
第4页 / 共11页
ANSI ASTM F431-2004 Standard Specification for Air Performance Measurement Plenum Chamber for Vacuum Cleaners.pdf_第5页
第5页 / 共11页
点击查看更多>>
资源描述

1、Designation: F431 04 (Reapproved 2013) An American National StandardStandard Specification forAir Performance Measurement Plenum Chamber for VacuumCleaners1This standard is issued under the fixed designation F431; the number immediately following the designation indicates the year of originaladoptio

2、n or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A superscriptepsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers the acceptable details andtolerances for the plen

3、um chamber used in specified airperformance measurement tests for vacuum cleaners.1.2 The plenum chamber is designed for vacuum measure-ments only. (WarningThe plenum chamber has been shownto accurately determine maximum air power values at varioustest points for vacuum cleaners. There is a possibil

4、ity that theairflow values measured with orifices larger than 2 in. at highflow rates may be erroneous due to the proximity of the top andbottom surfaces to the orifice plate inlet.)1.3 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathemati

5、calconversions to SI units that are provided for information onlyand are not considered standard.2. Referenced Documents2.1 ASTM Standards:2F558 Test Method for Measuring Air Performance Charac-teristics of Vacuum CleanersF820 Test Method for Measuring Air Performance Charac-teristics of Central Vac

6、uum Cleaning Systems2.2 ASTM Adjunct:Orifice Plate Holder Details (F431)33. Details3.1 Plenum chambers conforming to this specification shallbe fabricated in accordance with the dimensions, tolerances,and notes shown in the following figures:3.1.1 Plenum chamber assembly, see Fig. 1.3.1.2 Orifice pl

7、ate detail, see Fig. 2.3.1.3 Orifice plate holder and assembly, see Fig. 3.3.2 Manometer connection detail, see Fig. 1(f), Note 17.4. Orifice Plates4.1 Orifice plates conforming to this specification shall befabricated in accordance to the dimensions, tolerances, andnotes shown in the following figu

8、re:4.1.1 Orifice plate dimensional detail, see Fig. 2(a).4.1.2 Acceptable machined edges for orifice plates, see Fig.2(b).5. Keywords5.1 air performance; orifice plate; plenum chamber; vacuumcleaner1This specification is under the jurisdiction of ASTM Committee F11 onVacuum Cleaners and is the direc

9、t responsibility of Subcommittee F11.22 on AirPerformance.Current edition approved May 1, 2013. Published July 2013. Originally approvedin 1975. Last previous edition approved in 2008 as F431 04 (2008). DOI:10.1520/F0431-04R13.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orc

10、ontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from ASTM International Headquarters. Order Adjunct No.ADJF4031.Copyright ASTM International, 100 Barr Harbor Drive, PO Box

11、 C700, West Conshohocken, PA 19428-2959. United States1FIG. 1 (a) Plenum Chamber (Material: see Note 8)FIG. 1 (b) Hose Connector Plate (Material: 0.250-in. (6.35-mm) Steel) (continued)F431 04 (2013)2FIG. 1 (c) Hose Connector (Material: Aluminum or Steelsee Note 16) (continued)FIG. 1 (d) Flange Plate

12、 (Material: 0.250-in. (6.35-mm) Steel) (continued)F431 04 (2013)3FIG. 1 (e) Cleaner Plate (Material: 0.250-in. (6.35-mm) Steel) (continued)F431 04 (2013)4NOTE 1All dimensions are measured from inside surfaces.NOTE 2Interior must be clean, smooth, and free of projections or recesses on walls or attac

13、hment openings. Internal bracing should not be used tosupport plenum chamber walls.NOTE 3Attachment port edge to be smooth and well rounded.NOTE 4Orifice box must withstand 180 in. of water (336 mm Hg) negative static pressure without significant distortion of walls or joints afterchamber is complet

14、ely fabricated and attachment made.NOTE 5All joints and connections must be airtight.NOTE 6Tolerances (unless otherwise specified): one-place decimal 60.031 in. (0.080 mm); two-place decimal 60.01 in. (0.25 mm); three-placedecimal 60.005 in. (0.13 mm).NOTE 7Flange plate and manometer connection to b

15、e welded to chamber completely around the sides.NOTE 8Plenum chamber minimum material specification 0.187 in. (4.75 mm) thick low carbon steel.NOTE 90.060 in. (1.52 mm) thick rubber seal dimensioned similar to flange plate should be used to seal cleaner and hose connector plates.NOTE 10Bore 0.375 in

16、. (9.54 mm) through hole in plenum chamber for manometer connection and 3.000-in. (76.20-mm) diameter hole for orificeplate assembly.NOTE 11All mating holes to be concentric to within 0.005 in. (0.13 mm) T.I.R. after assembly.NOTE 12A 0.060-in. (1.52-mm) thick rubber seal dimensioned similar to hose

17、 connector should be used to seal the hose connector plate to hoseconnector.NOTE 13Six14-20 UNC-2B hex nuts or wing nuts should be used to fasten hose connector to hose connector plate.NOTE 14Thirty-six14-20 UNC-2A screws should be used to fasten either the cleaner plate or hose connector flange pla

18、te.NOTE 15Alternative materials, thicknesses, and construction methods may be used; however, requirements of Notes 2 and 4 and all internaldimensions must be complied with.NOTE 16Hose connector internal diameter and length may be changed to accommodate specific hose construction.NOTE 17If a water co

19、lumn manometer or electronic pressure gauge without integration is used, it is recommended that the inner diameter of themanometer connection port be 0.020 in. or as small as possible to minimize manometer overshoot and bounce. As an alternative to fabricating this holediameter, a hypodermic needle

20、with an inner diameter of 0.020 in. may be placed in the line between the plenum box and the manometer.FIG. 1 (f) Manometer Connection (Material: Steel) (continued)F431 04 (2013)5FIG. 2 (a) Orifice PlateNOTE 1Proper installation of the sharp orifice into the holder assembly of the plenum chamber is

21、with the sharp edge away from the chamber.Installing the sharp edge orifice toward the chamber may produce incorrect results.NOTE 2The circular sharp edge orifice should have neither wire edges nor burrs and is considered sharp if, when viewed with the naked eye, the edgedoes not seem to reflect a b

22、eam of light. The maximum diameter used shall not exceed 2.500 in. (60.350 mm) in diameter.NOTE 3Tolerance (unless other specified): one-place decimal 6 0.031 in. (0.80 mm): two-place decimal 6 0.010 in. (0.25 mm): three-place decimal60.005 in. (0.13 mm).NOTE 4The sizes of orifice plates required by

23、 Test Methods F558 and F820 are Plate Numbers 3, 5, 7, 9, 10, 11, 12, 13, 14, 15, and 16 (orifice platenos. 1, 2, 4, 6, and 8 are optional).NOTE 5AISI 4130 steel hardened to RC 42 to 47, finish black oxide, or 316 stainless steel plate 0.0595 6 0.0030 in. (1.511 6 0.076 mm) thick.FIG. 2 (b) Side Vie

24、w, Orifice Plate (continued)F431 04 (2013)6FIG. 3 Orifice Plate Holder AssemblyNOTE 1Hole in seal gasket, must center on hole in plenum chamber wall and on throat of mounting ring when in place.NOTE 2See orifice plate (Fig. 2) for tolerances.NOTE 3Material: rubber, elastomeric sealing material or ga

25、sket material for pressure joints.NOTE 4This part may be eliminated if male flange is sealed by weld, solder, or other mechanical methods that make an airtight seal.FIG. 3 (a) Flange Seal Gasket (continued)F431 04 (2013)7NOTE 1Screw holes must line up with holes in orifice plate holder (Fig. 3d).NOT

26、E 2See orifice plate drawing (Fig. 2) for tolerances.NOTE 3Material: brass or steel.FIG. 3 (b) Holder Ring (continued)NOTE 1See orifice plate drawing (Fig. 2) for tolerances.NOTE 2Material: nylon, polymer or elastomeric compounds.FIG. 3 (c) Washer (continued)F431 04 (2013)8NOTE 1With square corner o

27、rifice plates a relief is required for plate to bottom in holder 0.054 in. (1.47 mm) deep to match plane of recess.NOTE 2See orifice plate drawing (Fig. 2) for tolerances.NOTE 34.250 in. (107.95 mm) screw hole centerline and holes must match holder ring (Fig. 3b).NOTE 4Material: steel or brass.FIG.

28、3 (d) Orifice Holder (continued)F431 04 (2013)9APPENDIX(Nonmandatory Information)X1. SUGGESTED PROCEDURE FOR LEAK TESTING OF THE PLENUM CHAMBERX1.1 ScopeX1.1.1 This section covers a recommended procedure to beused in evaluating leaks in the plenum chamber.X1.2 ProcedureX1.2.1 Connect the plenum cham

29、ber to the manometerusing14 in. inside diameter vinyl tubing as shown in Fig. X1.1.X1.2.2 Seal off the test unit inlet using a gasketed plate orother suitable means.X1.2.3 Insert the sealed suction orifice plate into the orificeplate holder and secure.X1.2.4 Using a vacuum source, apply 80 to 90 in.

30、 of watercolumn vacuum to the suction source tubing inlet depicted inFig. X1.1. (This can be achieved by inserting and sealing thetubing inlet into a crevice nozzle connected to a canistervacuum product which utilizes a two stage vacuum motor/blower system).X1.2.5 Pinch off the suction source tubing

31、 using a clampand remove the inlet tubing from the vacuum source. Wait 15to 20 s, in order to allow the water column to drain andstabilize, and then record the initial manometer value to within0.1 in. of water column.X1.2.6 After 15 min has elapsed, record the final manom-eter value to within 0.1 in

32、. water column.X1.2.7 If the initial and final readings differ by more than0.1 in. of water column, investigate the source of plenumNOTE 1Holes are for centering and fastening the mounting ring to plenum chamber wall using screws and a sealing gasket. Optional methods ofmounting are acceptable, prov

33、ided mounting ring is centered on hole specified in plenum chamber wall and resulting joint is air tight.NOTE 2See orifice plate (Fig. 2) for tolerances.NOTE 3The mounting ring usually is positioned on the plenum chamber wall with the orifice plate vertical (when locked). Other positions resultingfr

34、om construction of the plenum chamber are acceptable.NOTE 4Surface “A” must be flat within 0.005 in. (0.13 mm); finish to be 63 in. (1.6 m).NOTE 5Material: Steel or brass.FIG. 3 (e) Mounting Ring(continued)F431 04 (2013)10chamber leaks and repair as required. Repeat this test until thedrop in plenum

35、 chamber pressure is less than 0.1 in. of watercolumn after 15 min.ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentionedin this standard. Users of this standard are expressly advised that determination of the validity of any

36、such patent rights, and the riskof infringement of such rights, are entirely their own responsibility.This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years andif not revised, either reapproved or withdrawn. Your comments are inv

37、ited either for revision of this standard or for additional standardsand should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of theresponsible technical committee, which you may attend. If you feel that your comments have not received

38、 a fair hearing you shouldmake your views known to the ASTM Committee on Standards, at the address shown below.This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,United States. Individual reprints (single or multiple copies) of th

39、is standard may be obtained by contacting ASTM at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.org). Permission rights to photocopy the standard may also be secured from the Copyright Clearance Center, 222Rosewood Drive, Danvers, MA 01923, Tel: (978) 646-2600; http:/ X1.1 Test ApparatusF431 04 (2013)11

展开阅读全文
相关资源
  • ANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdfANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdf
  • ANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdfANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdf
  • ANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdfANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdf
  • ANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdfANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdf
  • ANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdfANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdf
  • ANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdfANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdf
  • ANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdfANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdf
  • ANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdfANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdf
  • ANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdfANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdf
  • ANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdfANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ANSI

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1