ANSI ASTM F820-2017 Standard Test Method for Measuring Air Performance Characteristics of Central Vacuum Cleaning Systems.pdf

上传人:inwarn120 文档编号:433300 上传时间:2018-11-11 格式:PDF 页数:17 大小:329.87KB
下载 相关 举报
ANSI ASTM F820-2017 Standard Test Method for Measuring Air Performance Characteristics of Central Vacuum Cleaning Systems.pdf_第1页
第1页 / 共17页
ANSI ASTM F820-2017 Standard Test Method for Measuring Air Performance Characteristics of Central Vacuum Cleaning Systems.pdf_第2页
第2页 / 共17页
ANSI ASTM F820-2017 Standard Test Method for Measuring Air Performance Characteristics of Central Vacuum Cleaning Systems.pdf_第3页
第3页 / 共17页
ANSI ASTM F820-2017 Standard Test Method for Measuring Air Performance Characteristics of Central Vacuum Cleaning Systems.pdf_第4页
第4页 / 共17页
ANSI ASTM F820-2017 Standard Test Method for Measuring Air Performance Characteristics of Central Vacuum Cleaning Systems.pdf_第5页
第5页 / 共17页
点击查看更多>>
资源描述

1、Designation: F820 17 An American National StandardStandard Test Method forMeasuring Air Performance Characteristics of CentralVacuum Cleaning Systems1This standard is issued under the fixed designation F820; the number immediately following the designation indicates the year of originaladoption or,

2、in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A superscriptepsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers procedures for determining airperformance characteristics

3、 of household central vacuumcleaning systems, which use a flexible cleaning hose assemblyand incorporates a series universal motor(s). This test methoddoes not apply to the carpet cleaning mode of operation wheredirt or debris is involved.1.2 These tests and calculations include determination ofsuct

4、ion, airflow, air power, maximum air power, and inputpower under standard operating conditions (see Note 1).NOTE 1For more information on air performance characteristics, seeRefs (1-6).21.3 The values stated in inch-pound units are to be regardedas the standard. The values given in parentheses are p

5、rovidedfor information only.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety, health, and environmental practices and deter-mine the applicability of regulat

6、ory limitations prior to use. Aspecific precautionary statement is given in Note 4.1.5 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards, Guid

7、es and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:3E1 Specification for ASTM Liquid-in-Glass ThermometersE177 Practice for Use of the Terms Precision and Bias inASTM Test MethodsE691 Practice for Conduc

8、ting an Interlaboratory Study toDetermine the Precision of a Test MethodE2251 Specification for Liquid-in-Glass ASTM Thermom-eters with Low-Hazard Precision LiquidsF431 Specification for Air Performance Measurement Ple-num Chamber for Vacuum Cleaners2.2 AMCA Standard:421085 Laboratory Methods of Tes

9、ting Fans for Rating2.3 IEC Standard:5IEC 62885-2 Surface Cleaning Appliances Part 2: DryVacuum Cleaners for Household or Similar Use Meth-ods for Measuring the Performance3. Terminology3.1 Definitions:3.1.1 air power, AP, W, nin a vacuum cleaner, the net timerate of work performed by an air stream

10、while expendingenergy to produce an airflow by a vacuum cleaner underspecified air resistance conditions.3.1.2 automatic bleed valve, nany device a part of avacuum cleaners design, which automatically introduces anintentional leak within the vacuum cleaners system whenmanufacturer specified conditio

11、ns are met.3.1.3 corrected airflow, Q, cfm, nin a vacuum cleaner, thevolume of air movement per unit of time under standardatmospheric conditions.3.1.4 input power, W, nthe rate at which electrical energyis absorbed by a vacuum cleaner.3.1.5 model, nthe designation of a group of vacuumcleaners havin

12、g the same mechanical and electrical construc-tion with only cosmetic or nonfunctional differences.3.1.6 population, nthe total of all units of a particularmodel vacuum cleaner being tested.1This test method is under the jurisdiction of ASTM Committee F11 on VacuumCleaners and is the direct responsi

13、bility of Subcommittee F11.22 on Air Perfor-mance.Current edition approved Sept. 1, 2017. Published October 2017. Originallyapproved in 1988. Last previous edition approved in 2016 as F820 16. DOI:10.1520/F0820-17.2The boldface numbers in parentheses refer to the list of references at the end ofthis

14、 standard.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.4Available from Air Movement and Control Associatio

15、n, Inc., 30 West Univer-sity Dr., Arlington Heights, IL 600041893.5Available from the IEC Web store, webstore.iec.ch, or American NationalStandards Institute (ANSI), 25 W. 43rd St., 4th Floor, New York, NY 10036.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA

16、19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Te

17、chnical Barriers to Trade (TBT) Committee.13.1.7 repeatability limit (r), nthe value below which theabsolute difference between two individual test results obtainedunder repeatability conditions may be expected to occur with aprobability of approximately 0.95 (95 %).3.1.8 reproducibility limit (R),

18、nthe value below which theabsolute difference between two test results obtained underreproducibility conditions may be expected to occur with aprobability of approximately 0.95 (95 %).3.1.9 repeatability standard deviation (Sr), nthe standarddeviation of test results obtained under repeatability con

19、di-tions.3.1.10 reproducibility standard deviation (SR), nthe stan-dard deviation of test results obtained under reproducibilityconditions.3.1.11 sample, na group of vacuum cleaners taken from alarge collection of vacuum cleaners of one particular model,which serves to provide information that may b

20、e used as a basisfor making a decision concerning the larger collection.3.1.12 standard air density, std, lb/ft3,natmospheric airdensity of 0.075 lb/ft3(1.2014 kg/m3).3.1.12.1 DiscussionThis value of air density correspondsto atmospheric air at a temperature of 68 F (20 C), 14.696 psi(101.325 kPa),

21、and approximately 30 % relative humidity.3.1.13 suction, inch of water, nin a vacuum cleaner, theabsolute difference between ambient and subatmospheric pres-sure.3.1.14 test run, nthe definitive procedure that producesthe singular result of calculated maximum air power.3.1.15 test station pressure,

22、Bt, inch of mercury, nfor avacuum cleaner, the absolute barometric pressure at the testlocation (elevation) and test time.3.1.15.1 DiscussionIt is not the equivalent mean sea levelvalue of barometric pressure typically reported by the airportand weather bureaus. It is sometimes referred to as theunc

23、orrected barometric pressure (that is, not corrected to themean sea level equivalent value). Refer to 5.4 for additionalinformation.3.1.16 unit, na single vacuum cleaner of the model beingtested.4. Significance and Use4.1 The test results allow the comparison of the maximumair power available when n

24、o dirt has been introduced into thevacuum cleaning system, that is, a completely clean filter or anempty, clean dirt container.5. Apparatus5.1 Plenum ChamberSee Specification F431 or IEC62885-2, Section 5.8.3.5.2 Water Manometers, or equivalent instruments. One tomeasure from 0 to 6 in. (152.4 mm) i

25、n increments of 0.01 in.(0.254 mm), and one with increments of 0.1 in. (2.54 mm) foruse in making measurements above 6 in. (152.4 mm). A singleinstrument having a resolution of 0.01 in. (0.254 mm) over theentire required range may be used instead of two separateinstruments.5.3 Power analyzer, to pro

26、vide measurements accurate towithin 61%.5.4 Barometer, with an accuracy of 60.05 in. (1.27 mm) ofmercury, capable of measuring and displaying absolute baro-metric pressure, scale divisions 0.02 in. (0.51 mm) or finer.5.4.1 Mercury barometers, in general, measure and displaythe absolute barometric pr

27、essure. Some corrections may beneeded for temperature and gravity. Consult the ownersmanual.5.4.2 When purchasing an aneroid or electronic barometer,be sure to purchase one which displays the absolute barometricpressure, not the mean sea level equivalent barometric pressurevalue. These types of baro

28、meters generally have temperaturecompensation built into them and do not need to be correctedfor gravity.5.5 Sharp-Edge Orifice PlatesSee Specification F431.5.6 ThermometerSolid-stem, ambient thermometer hav-ing a range from 18 to 89F (or 8 to +32C) with graduationsin 0.2F (0.1C), conforming to the

29、requirements for thermom-eter 63F (17C) as prescribed in Specification E1.Asanalternative, thermometers S63F or S63C, as prescribed inSpecification E2251, may be used. In addition, thermometricdevices such as resistance temperature detectors (RTDs),thermistors, or thermocouples of equal or better ac

30、curacy maybe used.5.7 PsychrometerThermometers graduated in 0.2 F (0.1C).5.8 Voltage-Regulator System, to control the input voltageto the vacuum cleaner. The regulator system shall be capable ofmaintaining the vacuum cleaners rated voltage 61 % andrated frequency 61 Hz having a wave form that is ess

31、entiallysinusoidal with 3 % maximum harmonic distortion for theduration of the test.5.9 Orifice Adapter TubeSee Fig. 1.6. Sampling6.1 A minimum of three units of the same model vacuumcleaner selected at random in accordance with good statisticalpractice, shall constitute the population sample.6.1.1

32、To determine the best estimate of maximum air powerfor the population of the vacuum cleaner model being tested,the arithmetic mean of the maximum air power of the samplefrom the population shall be established by testing it to a 90 %confidence level within 65%.6.1.2 Annex A2 provides a procedural ex

33、ample for deter-mining the 90 % confidence level and when the sample sizeshall be increased.NOTE 2See Annex A2 for method of determining 90 % confidencelevel.7. Test Vacuum Cleaners7.1 New Test Vacuum CleanerRun the vacuum cleaner inat rated voltage 61% and rated frequency with filters in placefor 1

34、 h with a wide-open inlet (without hose).7.2 Used Test Vacuum CleanersRecondition a used testvacuum cleaner; prior to the initial test run as follows:F820 1727.2.1 Thoroughly remove excess dirt from the vacuumcleaner. Without using tools for disassembly, clean the entireouter surface, brushes, nozzl

35、e chamber, ductwork, inside of thechamber surrounding the primary filter, and inside hose andwands.7.2.2 For vacuum cleaners using disposable filters as theprimary filters, use a new disposable primary filter from themanufacturer for each test. Install it as recommended by thevacuum cleaner manufact

36、urer.7.2.3 For vacuum cleaners using non-disposable dirtreceptacles, empty in accordance with the manufacturersinstructions and clean the receptacle until its weight is within0.07 oz (2 g) of its original weight and install it as recom-mended by the vacuum cleaner manufacturer.7.2.4 For vacuum clean

37、ers using non-disposable dirtreceptacles, empty in accordance with the manufacturersinstructions and clean the receptacle until its weight is within0.07 oz (2 g) of its original weight and install it as recom-mended by the vacuum cleaner manufacturer.NOTE 3It is preferable to conduct this test metho

38、d on new test vacuumcleaners prior to any otherASTM test methods to avoid contamination thatcould cause performance variations.7.3 Test Vacuum Cleaner SettingsIf various settings areprovided, set the motor speed setting or suction regulator usingthe manufacturers specifications as provided in the in

39、structionmanual for normal operation. If a different setting is used,make a note of the deviation in the test report.8. Procedure8.1 Preparation for Test:8.1.1 Prepare the test unit in accordance with Section 7.Set-up the test system as shown in Fig. 2. On the intake side,use an adapter terminating

40、with the wall inlet valve. This wallinlet is to be the one specified for installation with the powerunit being tested. All joints should be made in accordance withthe manufacturers specifications and be free of leaks. Insertinto the wall valve a flexible cleaning hose as provided with thesystem. The

41、 hose assembly should be that which is offerednormally with the particular unit being tested. For thosesystems, which provide for an external exhaust, connect 2 ft(0.6 m) of exhaust comprised of tubing and exhaust muffler, ifa muffler is provided as part of the system.8.1.2 Set the manometers to zer

42、o and check all instrumentsfor proper operation.8.1.3 Record the test station pressure and the dry-bulb andwet-bulb temperature readings within 6 ft (1.8 m) of the testarea. Read the barometric pressure to the nearest 0.02 in. (0.51mm) of mercury, and the dry-bulb and wet-bulb temperaturesto the nea

43、rest 0.2 F (or 0.1 C).8.1.3.1 The test area shall be free of major fluctuatingtemperature conditions due to air conditioners or air drafts thatwould be indicated by a thermometer at the immediate testarea.8.1.4 Connect the manometer or equivalent instrument tothe plenum chamber.FIG. 1 Orifice Adapte

44、r TubeF820 1738.1.5 Connect a power analyzer.8.2 Test Procedure:8.2.1 Connect the hose assembly to the plenum chamberhose adapter and seal only this connection (see Fig. 3).8.2.1.1 The end of the hose assembly should be insertedinside the hose connector adapter and be perpendicular to theplenum cham

45、ber.8.2.1.2 The end of the hose assembly shall not project intothe plenum chamber.8.2.1.3 Any automatic bleed valve, which affects the airperformance of the vacuum cleaner, shall not be defeated.8.2.2 The hose should be supported and kept straight andhorizontal over its entire length.Allowance shoul

46、d be made forthe foreshortening of the hose assembly under the vacuum.Maintain the power unit and dirt canister in their normaloperating orientation.8.2.3 Operate the vacuum cleaner with no orifice plateinserted in the plenum chamber inlet at nameplate rated voltage61 % and frequency 61 Hz prior to

47、the start of the test run toallow the unit to reach its normal operating temperature. Forvacuum cleaners with dual nameplate voltage ratings, conducttesting at the highest voltage.Allow the unit to reach its normaloperating temperature before each test run.8.2.4 The vacuum cleaner is to be operated

48、at its nameplaterated voltage 61 % and frequency 61 Hz throughout the test.For vacuum cleaners with dual nameplate voltage ratings,conduct the test at the highest voltage.8.2.4.1 Allow the vacuum cleaner to operate at the openorifice for 1 to 2 min between test runs.8.2.5 While operating the vacuum

49、cleaner in accordancewith 8.2.4, insert orifice plates sequentially into the orificeplate holder of the plenum chamber starting with the largestsize orifice and following it with the next smaller orifice plate.Use the following orifice plates: 2.0, 1.5, 1.25, 1.0, 0.875, 0.75,0.625, 0.5, 0.375, 0.25, 0.0 in. (50.8, 38.1, 31.7, 25.4, 22.2,19.0, 15.8, 12.7, 9.5, 6.3 mm). The following optional orificeplates also may be used: 2.5, 2.25, 1.75, 1.375, 1.125 in. (63.5,57.2, 44.5, 34.9, 28.6 mm).8.2.6 For each orifice plate, record

展开阅读全文
相关资源
  • ANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdfANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdf
  • ANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdfANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdf
  • ANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdfANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdf
  • ANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdfANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdf
  • ANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdfANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdf
  • ANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdfANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdf
  • ANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdfANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdf
  • ANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdfANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdf
  • ANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdfANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdf
  • ANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdfANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ANSI

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1