ANSI CSA AM Z21.57A-2012 Standard for Recreational Vehicle Cooking Gas Appliances (Addenda to the Tenth Edition).pdf

上传人:eveningprove235 文档编号:434437 上传时间:2018-11-11 格式:PDF 页数:10 大小:461.73KB
下载 相关 举报
ANSI CSA AM Z21.57A-2012 Standard for Recreational Vehicle Cooking Gas Appliances (Addenda to the Tenth Edition).pdf_第1页
第1页 / 共10页
ANSI CSA AM Z21.57A-2012 Standard for Recreational Vehicle Cooking Gas Appliances (Addenda to the Tenth Edition).pdf_第2页
第2页 / 共10页
ANSI CSA AM Z21.57A-2012 Standard for Recreational Vehicle Cooking Gas Appliances (Addenda to the Tenth Edition).pdf_第3页
第3页 / 共10页
ANSI CSA AM Z21.57A-2012 Standard for Recreational Vehicle Cooking Gas Appliances (Addenda to the Tenth Edition).pdf_第4页
第4页 / 共10页
ANSI CSA AM Z21.57A-2012 Standard for Recreational Vehicle Cooking Gas Appliances (Addenda to the Tenth Edition).pdf_第5页
第5页 / 共10页
点击查看更多>>
资源描述

1、ANSI Z21.57a-2012Addenda to the Tenth Edition ANSI Z21.57-2010Standard forRecreational Vehicle Cooking Gas AppliancesLegal Notice for StandardsCanadian Standards Association and CSA America, Inc. (operating as “CSA Group”) develop standards through a consensusstandards development process approved b

2、y the Standards Council of Canada. This process brings together volunteers representingvaried viewpoints and interests to achieve consensus and develop a standard. Although CSA Group administers the process andestablishes rules to promote fairness in achieving consensus, it does not independently te

3、st, evaluate, or verify the content ofstandards.Disclaimer and exclusion of liabilityThis document is provided without any representations, warranties, or conditions of any kind, express or implied, including, withoutlimitation, implied warranties or conditions concerning this documents fitness for

4、a particular purpose or use, its merchantability, orits non-infringement of any third partys intellectual property rights. CSA Group does not warrant the accuracy, completeness, orcurrency of any of the information published in this document. CSA Group makes no representations or warranties regardin

5、g thisdocuments compliance with any applicable statute, rule, or regulation. IN NO EVENT SHALL CSA GROUP, ITS VOLUNTEERS, MEMBERS, SUBSIDIARIES, OR AFFILIATED COMPANIES, OR THEIR EMPLOYEES,DIRECTORS, OR OFFICERS, BE LIABLE FOR ANY DIRECT, INDIRECT, OR INCIDENTAL DAMAGES, INJURY, LOSS, COSTS, OREXPEN

6、SES, HOWSOEVER CAUSED, INCLUDING BUT NOT LIMITED TO SPECIAL OR CONSEQUENTIAL DAMAGES, LOST REVENUE,BUSINESS INTERRUPTION, LOST OR DAMAGED DATA, OR ANY OTHER COMMERCIAL OR ECONOMIC LOSS, WHETHER BASED INCONTRACT, TORT (INCLUDING NEGLIGENCE), OR ANY OTHER THEORY OF LIABILITY, ARISING OUT OF OR RESULTI

7、NG FROMACCESS TO OR POSSESSION OR USE OF THIS DOCUMENT, EVEN IF CSA GROUP HAS BEEN ADVISED OF THE POSSIBILITY OF SUCHDAMAGES, INJURY, LOSS, COSTS, OR EXPENSES.In publishing and making this document available, CSA Group is not undertaking to render professional or other services for or onbehalf of an

8、y person or entity or to perform any duty owed by any person or entity to another person or entity. The information inthis document is directed to those who have the appropriate degree of experience to use and apply its contents, and CSA Groupaccepts no responsibility whatsoever arising in any way f

9、rom any and all use of or reliance on the information contained in thisdocument. CSA Group is a private not-for-profit company that publishes voluntary standards and related documents. CSA Group has no power,nor does it undertake, to enforce compliance with the contents of the standards or other doc

10、uments it publishes. Intellectual property rights and ownershipAs between CSA Group and the users of this document (whether it be in printed or electronic form), CSA Group is the owner, or theauthorized licensee, of all works contained herein that are protected by copyright, all trade-marks (except

11、as otherwise noted to thecontrary), and all inventions and trade secrets that may be contained in this document, whether or not such inventions and tradesecrets are protected by patents and applications for patents. Without limitation, the unauthorized use, modification, copying, ordisclosure of thi

12、s document may violate laws that protect CSA Groups and/or others intellectual property and may give rise to aright in CSA Group and/or others to seek legal redress for such use, modification, copying, or disclosure. To the extent permitted bylicence or by law, CSA Group reserves all intellectual pr

13、operty rights in this document.Patent rightsAttention is drawn to the possibility that some of the elements of this standard may be the subject of patent rights. CSA Group shallnot be held responsible for identifying any or all such patent rights. Users of this standard are expressly advised that de

14、termination ofthe validity of any such patent rights is entirely their own responsibility.Authorized use of this documentThis document is being provided by CSA Group for informational and non-commercial use only. The user of this document isauthorized to do only the following:If this document is in

15、electronic form:load this document onto a computer for the sole purpose of reviewing it;search and browse this document; andprint this document if it is in PDF format. Limited copies of this document in print or paper form may be distributed only to persons who are authorized by CSA Group to havesuc

16、h copies, and only if this Legal Notice appears on each such copy.In addition, users may not and may not permit others toalter this document in any way or remove this Legal Notice from the attached standard;sell this document without authorization from CSA Group; ormake an electronic copy of this do

17、cument.If you do not agree with any of the terms and conditions contained in this Legal Notice, you may not load or use this document ormake any copies of the contents hereof, and if you do make such copies, you are required to destroy them immediately. Use of thisdocument constitutes your acceptanc

18、e of the terms and conditions of this Legal Notice. CSA Group 2012Permission is granted to republish material herein in laws or ordinances, and in regulations, administrative orders, or similar documents issued by public authorities. Those desiring permission for other republication should consult C

19、SA Group, 8501 East Pleasant Valley Road, Cleveland, Ohio 44131.PrefaceThe standards set forth herein apply to the tenth edition of the Standard for Recreational Vehicle Cooking Gas Appliances, ANSI Z21.57-2010, and supersede corresponding standards therein. Following their preparation by the superv

20、ising Technical Advisory Group, they were accepted by the American National Standards Institute (ANSI) and subsequently approved.NOTE: Changes, other than editorial, are denoted by a vertical line in the margin.ApprovedSeptember 21, 2012American National Standards Institute, Inc.Standard DeveloperCS

21、A AMERICA INC.,Operating as “CSA Group”8501 East Pleasant Valley RoadCleveland, Ohio 44131Published - September 20121September 2012ANSI Z21.57a-2012 2012 CSA GroupPart I: Construction1.1 Scope1.1.8An exhaust hood incorporated in an appliance shall comply with the applicable provisions of the Safety

22、Standard for Electric Fans, ANSI/UL507. Ventilation systems with provisions to direct air in a downward direction (Air Curtain Ventilation System), although not supplied with the range or cooktop, are a part of the listing of the range or cooktop as outlined in Section 1.25.13 and Section 2.23, Perf

23、ormance of Appliances Intended to be Utilized With Ventilations Systems That Direct Air In a Downward Direction.1.25 Instructions1.25.12For gas cooking appliances that have been tested under Section 2.33, Performance of Appliances Intended to be Utilized With Ventilations Systems That Direct Air In

24、a Downward Direction, the manufacturer shall detail the brands and model numbers of those ventilation systems found acceptable.A warning statement shall be also made that using models or brands that direct air in a downward direction other than the ones specified may lead to improper operation of th

25、e gas appliance and may result in personal injury or property damage. Ventilating systems that direct the air upwards do not have any restriction.Instructions that if the model number ventilation hood is no longer available the owner should contact the range manufacturer for acceptable replacement v

26、entilation system model numbers.For ranges not tested under Section 2.23 and not intended for use in conjunction with a ventilation system with provisions to direct air in a downward direction, instructions shall include a statement that the appliance should not be installed with a ventilation syste

27、m that blows air downward toward the range. The instructions shall also include that this type of ventilation system may cause ignition and combustion problems with the gas cooking appliance resulting in personal injury or unintended operation.1.25.13A statement that an air curtain or other overhead

28、 range hood, which operates by blowing a downward airflow onto a range, shall not be used in conjunction with a gas range unless the hood and range have been designed, and tested in accordance with the Standard for Recreational Vehicle Cooling Gas Appliances, ANSI Z21.57 and listed by an independent

29、 testing laboratory for combination use. The installation instructions for both the gas range and air curtain range hood shall include statements that the air curtain or overhead range hood is permitted to be used in conjunction with a gas range, and the gas range and air curtain range hood have bee

30、n designed and tested in accordance with the Standard for Household Cooking Gas Appliances, ANSI Z21.1, and listed by an independent testing laboratory for combination use.1.26 Marking1.26.13A Class VI marking shall include the following information:A statement that an air curtain or other overhead

31、range hood, which operates by blowing a downward airflow onto a range, shall not be used in conjunction with a gas range unless the hood and range have been designed, tested and listed by an independent testing laboratory for combination use. The marking 2September 2012Standard for recreational 2012

32、 CSA Group vehicle cooking gas appliancesshould also direct the purchaser/installer to review the installation instructions to determine if their range is acceptable for use with such a ventilation system and what are the acceptable manufacturer(s) and model number(s) of such products.3September 201

33、2ANSI Z21.57a-2012 2012 CSA GroupPart II: Performance2.4 Combustion2.4.1An appliance shall not produce a concentration of carbon monoxide in excess of 0.04 percent in an air-free sample of the flue gases when the appliance is tested in a room having approximately a normal oxygen supply.During combus

34、tion tests of a built-in unit, all cracks or other openings (other than the designed air openings) shall be sealed. At the conclusion of the combustion tests, the sealing means shall be removed.For ranges or cook tops intended for use in conjunction with a ventilation system with provisions to direc

35、t air in a downward direction, combustion testing shall be performed on any enclosed compartment (oven or broiler), specialty top section burners which operate automatically such as thermostatically controlled griddles, open top broilers, or any other burner hidden from view of the operator. After t

36、he burners have been in operation for 5 minutes under Test Conditions 2 and 3 in Table I, Gas Pressure and Input Conditions for Use in the Various Performance Tests, samples of the flues gases shall be procured and analyzed for CO and CO2. During these tests no test pots shall be placed on the open

37、top burners and no 75 percent coverage plate shall be used over the open top broiler. Method of TestBurners shall be adjusted as specified by 2.3.5. Thermostats shall be set at their maximum open position after they have been adjusted as specified in 2.11, Thermostats.a. A flat bottom utensil 71/2in

38、 (191 mm) in diameter (bottom) as shown in Figure 7, Combustion Utensil, containing 5 lb (2.3 kg) ( 1 percent) at approximately room temperature shall be placed over each top burner. A suitably designed hood shall then be placed on the cooking top. Oven burners, broiler burners and any other gas-fir

39、ed and electrical cooking sections, capable of simultaneous operation, if incorporated into the appliance, shall be placed in operation simultaneously with the top burners and shall be operated during the time the samples of flue gases from the top burners are being secured. After the top burners ha

40、ve been in operation for 5 minutes under Test Conditions 2 and 3a or 3b in Table I, Gas Pressure and Input Rate Conditions for Use in the Various Performance Tests (see 2.3.4), samples of the flue gases shall be secured from the hood vent and analyzed for carbon monoxide and carbon dioxide.b. Two ad

41、jacent top burners shall be covered as symmetrically as possible with cast iron griddle plates 91/2in (241 mm) in diameter having he bottom recessed 3/16in (4.8 mm) with approximately a 1/8in wide (3.2 mm) lip. (See Figure 8, Griddle Plate Used In Combustion Test.) When a burner having an input rati

42、ng of 12,000 Btu/hr (3 517 W) or more is provided, it shall be one of those covered by the griddle plates. If there is less than a 91/2 in (241 mm) clearance between adjacent top burner centers, only one burner need be covered with a griddle plate. A 71/2in (191 mm) diameter (bottom) water filled ut

43、ensil (see 2.4.1-a and Figure 7, Combustion Utensil, shall be placed on each of the griddle plates and over each of the remaining top burners.c. When the construction of the utensil supports is such that they can be positioned so as to cause the burner flames to impinge on the utensil support bars,

44、the top burner tests shall be conducted with the utensil supports in that position.d. A griddle burner section shall be tested with the manufacturers griddle installed in accordance with the manufacturers instructions. The range top burner test utensil described in Figure 7, Combustion Utensil, cont

45、aining 5 lb (2.3 kg) ( 1 percent) shall be placed on the griddle. A suitably designed 4September 2012Standard for recreational 2012 CSA Group vehicle cooking gas applianceshood shall be placed over the griddle in such a manner as to collect all of the griddle burner(s) flue gases. Oven burners, broi

46、ler burners and any other gas-fired and electrical cooking sections capable of simultaneous operation, if incorporated in the appliance, shall be placed in operation simultaneously with the griddle burner and shall be operated during the time the samples are being secured. After the griddle burner h

47、as been in operation for 5 minutes under Test Conditions 2 and 3a or 3b in Table I, Gas Pressure and Input Rate Conditions for Use in the Various Performance Tests, samples of the flue gases shall be secured from the hood vent and analyzed for carbon monoxide and carbon dioxide. If a griddle section

48、 can be operated with or without the manufacturers griddle installed, testing shall be conducted under both conditions.e. An open top broiler section or unit shall be tested with 75 percent of the effective grid area covered with a flat sheet-metal plate. This plate shall be shaped and positioned so

49、 the uncovered area is a space of equal width around the perimeter of the broiler grid. During each test a suitably designed test hood of sufficient size to collect the flue gases shall be placed over the broiler section or unit. With the appliance operating under Test Conditions 2 and 3a or 3b in Table I, Gas Pressure and Input Rate Conditions for Use in Various Performance Tests and all burners in operation, samples of the flue gases shall be secured from the hood vent and analyzed for carbon monoxide and carbon dioxide after the burner(s) has been in operation for 5 minutes

展开阅读全文
相关资源
  • ANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdfANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdf
  • ANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdfANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdf
  • ANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdfANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdf
  • ANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdfANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdf
  • ANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdfANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdf
  • ANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdfANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdf
  • ANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdfANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdf
  • ANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdfANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdf
  • ANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdfANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdf
  • ANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdfANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ANSI

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1