1、C22.2 No. 4-16Enclosed and dead-front switchesLegal Notice for StandardsCanadian Standards Association (operating as “CSA Group”) develops standards through a consensus standards development process approved by the Standards Council of Canada. This process brings together volunteers representing var
2、ied viewpoints and interests to achieve consensus and develop a standard. Although CSA Group administers the process and establishes rules to promote fairness in achieving consensus, it does not independently test, evaluate, or verify the content of standards.Disclaimer and exclusion of liabilityThi
3、s document is provided without any representations, warranties, or conditions of any kind, express or implied, including, without limitation, implied warranties or conditions concerning this documents fitness for a particular purpose or use, its merchantability, or its non-infringement of any third
4、partys intellectual property rights. CSA Group does not warrant the accuracy, completeness, or currency of any of the information published in this document. CSA Group makes no representations or warranties regarding this documents compliance with any applicable statute, rule, or regulation.IN NO EV
5、ENT SHALL CSA GROUP, ITS VOLUNTEERS, MEMBERS, SUBSIDIARIES, OR AFFILIATED COMPANIES, OR THEIR EMPLOYEES, DIRECTORS, OR OFFICERS, BE LIABLE FOR ANY DIRECT, INDIRECT, OR INCIDENTAL DAMAGES, INJURY, LOSS, COSTS, OR EXPENSES, HOWSOEVER CAUSED, INCLUDING BUT NOT LIMITED TO SPECIAL OR CONSEQUENTIAL DAMAGE
6、S, LOST REVENUE, BUSINESS INTERRUPTION, LOST OR DAMAGED DATA, OR ANY OTHER COMMERCIAL OR ECONOMIC LOSS, WHETHER BASED IN CONTRACT, TORT (INCLUDING NEGLIGENCE), OR ANY OTHER THEORY OF LIABILITY, ARISING OUT OF OR RESULTING FROM ACCESS TO OR POSSESSION OR USE OF THIS DOCUMENT, EVEN IF CSA GROUP HAS BE
7、EN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES, INJURY, LOSS, COSTS, OR EXPENSES.In publishing and making this document available, CSA Group is not undertaking to render professional or other services for or on behalf of any person or entity or to perform any duty owed by any person or entity to anot
8、her person or entity. The information in this document is directed to those who have the appropriate degree of experience to use and apply its contents, and CSA Group accepts no responsibility whatsoever arising in any way from any and all use of or reliance on the information contained in this docu
9、ment.CSA Group is a private not-for-profit company that publishes voluntary standards and related documents. CSA Group has no power, nor does it undertake, to enforce compliance with the contents of the standards or other documents it publishes.Intellectual property rights and ownershipAs between CS
10、A Group and the users of this document (whether it be in printed or electronic form), CSA Group is the owner, or the authorized licensee, of all works contained herein that are protected by copyright, all trade-marks (except as otherwise noted to the contrary), and all inventions and trade secrets t
11、hat may be contained in this document, whether or not such inventions and trade secrets are protected by patents and applications for patents. Without limitation, the unauthorized use, modification, copying, or disclosure of this document may violate laws that protect CSA Groups and/or others intell
12、ectual property and may give rise to a right in CSA Group and/or others to seek legal redress for such use, modification, copying, or disclosure. To the extent permitted by licence or by law, CSA Group reserves all intellectual property rights in this document.Patent rightsAttention is drawn to the
13、possibility that some of the elements of this standard may be the subject of patent rights. CSA Group shall not be held responsible for identifying any or all such patent rights. Users of this standard are expressly advised that determination of the validity of any such patent rights is entirely the
14、ir own responsibility.Authorized use of this documentThis document is being provided by CSA Group for informational and non-commercial use only. The user of this document is authorized to do only the following:If this document is in electronic form: load this document onto a computer for the sole pu
15、rpose of reviewing it; search and browse this document; and print this document if it is in PDF format.Limited copies of this document in print or paper form may be distributed only to persons who are authorized by CSA Group to have such copies, and only if this Legal Notice appears on each such cop
16、y.In addition, users may not and may not permit others to alter this document in any way or remove this Legal Notice from the attached standard; sell this document without authorization from CSA Group; or make an electronic copy of this document.If you do not agree with any of the terms and conditio
17、ns contained in this Legal Notice, you may not load or use this document or make any copies of the contents hereof, and if you do make such copies, you are required to destroy them immediately. Use of this document constitutes your acceptance of the terms and conditions of this Legal Notice.Standard
18、s Update ServiceC22.2 No. 4-16February 2016Title: Enclosed and dead-front switchesTo register for e-mail notification about any updates to this publication go to shop.csa.ca click on CSA Update ServiceThe List ID that you will need to register for updates to this publication is 2423692.If you requir
19、e assistance, please e-mail techsupportcsagroup.org or call 416-747-2233.Visit CSA Groups policy on privacy at www.csagroup.org/legal to find out how we protect your personal information.Association of Standardization and CertificationNMX-J-162-ANCE-2016Fourth EditionCSA GroupCSA-C22.2 No. 4-16Eight
20、h EditionUnderwriters Laboratories Inc.UL 98Fourteenth EditionEnclosed and Dead-Front SwitchesFebruary 12, 2016ANSI/UL 98-2016Commitment for AmendmentsThis standard is issued jointly by the Association of Standardization and Certification (ANCE), theCanadian Standards Association (operating as “CSA
21、Group”), and Underwriters Laboratories Inc. (UL).Comments or proposals for revisions on any part of the standard may be submitted to ANCE, CSAGroup, or UL at anytime. Revisions to this standard will be made only after processing according to thestandards development procedures of ANCE, CSA Group, an
22、d UL. CSA Group and UL will issuerevisions to this standard by means of a new edition or revised or additional pages bearing their dateof issue. ANCE will incorporate the same revisions into a new edition of the standard bearing the samedate of issue as the CSA Group and UL pages.Copyright 2016 ANCE
23、Rights reserved in favor of ANCE.ISBN 978-1-77139-928-9 2016 CSA GroupAll rights reserved. No part of this publication may be reproduced in any form whatsoever without theprior permission of the publisher.This Standard is subject to review five years from the date of publication, and suggestions for
24、 itsimprovement will be referred to the appropriate committee. To submit a proposal for change, pleasesend the following information to inquirescsagroup.org and include Proposal for change in thesubject line: Standard designation (number); relevant clause, table, and/or figure number; wording ofthe
25、proposed change; and rationale for the change.To purchase CSA Group Standards and related publications, visit CSA Groups Online Store atshop.csa.ca or call toll-free 1-800-463-6727 or 416-747-4044.Copyright 2016 Underwriters Laboratories Inc.ULs Standards for Safety are copyrighted by UL. Neither a
26、printed nor electronic copy of a Standardshould be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regardingthose Standards shall remain the sole and exclusive property of UL.This ANSI/UL Standard for Safety consists of the Fourteenth edition. The most recent desi
27、gnation ofANSI/UL 98 as an American National Standard (ANSI) occurred on February 12, 2016. ANSI approvalfor a standard does not include the Cover Page, Transmittal Pages, Title Page (front and back), or thePreface.Comments or proposals for revisions on any part of the Standard may be submitted to U
28、L at any time.Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative StandardsDevelopment System (CSDS) at http:/.To purchase UL Standards, visit Comm 2000 at http:/m- call toll-free 1-888-853-3503.CONTENTSPreface .51 Scope .62 Normative References .73 Components 74 Units
29、of Measurement .85 Definitions 86 Construction .116.1 General 116.2 Enclosure 126.3 Operating mechanism 136.4 Accessibility of live parts .146.5 Electrical insulation material 146.6 Spacings .156.7 Current-carrying parts 216.8 Fusing .266.9 Field conversion .276.10 Enclosed switch wiring and bending
30、 space 296.11 Disconnecting means of the grounded service conductor 336.12 Provision for grounding .336.13 Provision for bonding .356.14 Electrically tripped switches 366.15 Additional service equipment requirements for Canada .367 Test methods 377.1 General 377.2 Heating test 397.3 Overload test .4
31、27.4 Endurance test 467.5 Dielectric voltage-withstand test .497.6 Clamped joint test 497.7 Close-open test .507.8 Short-circuit withstand test 517.9 Low-level dielectric voltage-withstand test 567.10 Short-circuit closing test .567.11 Strength of insulating base and support test .567.12 Electricall
32、y tripped switches 577.13 Mold stress relief test .597.14 Insulating barriers test 598 Ratings .598.1 General 598.2 Current .608.3 Voltage 608.4 Horsepower or kilowatts 628.5 Short-circuit current 649 Marking .649.1 General 649.2 All switches .659.3 Electrically tripped switches .72FEBRUARY 12, 2016
33、 NMX-J-162-ANCE-2016 CSA-C22.2 NO. 4-16 UL 98 3SUPPLEMENT SA - Enclosed and Deadfront Switches Intended for Marine UseSA1 Scope .77SA2 Definitions 77SA3 General 78SA4 Construction 78SA4.1 Enclosure protection against corrosion 78SA4.2 Current-carrying parts .79SA4.3 Insulating material 795 Performan
34、ce 79SA5.1 Vibration test .79SA5.2 Shock test .80SA5.3 Ignition protection test .80SA5.4 Dripproof enclosure test .81SA5.5 Watertight enclosure test 81SA6 Markings .81ANNEX A (normative)ANNEX B (informative)ANNEX C (normative)ANNEX D (informative)ANNEX E (informative)E1 Instrumentation .89E2 Galvano
35、meter Calibration 89E3 Alternating Current Circuits 10,000 A and Less .90E4 Alternating Current Circuits Greater than 10,000 A .91E5 Recovery Voltage AC .93E6 Direct Current Circuits .94ANNEX F (informative)FEBRUARY 12, 2016NMX-J-162-ANCE-2016 CSA-C22.2 NO. 4-16 UL 984PrefaceThis is the harmonized A
36、NCE, CSA Group, and UL standard for Enclosed and Dead-Front Switches.Itisthe Fourth edition of NMX-J-162-ANCE, the Eighth edition of CSA C22.2 No. 4, and the Fourteenth editionof UL 98. This harmonized standard has been jointly issued February 12, 2016.This harmonized standard was prepared by the As
37、sociation of Standardization and Certification (ANCE),CSA Group, and Underwriters Laboratories Inc., (UL). The efforts and support of the TechnicalHarmonization Committee for Enclosed Switches, of the Council on the Harmonization of ElectrotechnicalStandards of the Nations of the Americas (CANENA),
38、are gratefully acknowledged.This standard is considered suitable for use for conformity assessment within the stated scope of thestandard.This standard was reviewed by the CSA Subcommittee on Enclosed and Dead-Front Switches, under thejurisdiction of the CSA Technical Committee on Industrial Product
39、s and the CSA Strategic SteeringCommittee on Requirements for Electrical Safety, and has been formally approved by the CSA TechnicalCommittee.This standard has been approved by the American National Standards Institute (ANSI) as an AmericanNational Standard.Where reference is made to a specific numb
40、er of samples to be tested, the specified number shall beconsidered a minimum quantity.Note: Although the intended primary application of this standard is stated in its scope, it is important to note that it remainsthe responsibility of the users of the standard to judge its suitability for their pa
41、rticular purpose.Level of harmonizationThis standard uses the IEC format but is not based on, nor is it considered equivalent to, an IEC standard.This standard is published as an equivalent standard for ANCE, CSA Group, and UL.An equivalent standard is a standard that is substantially the same in te
42、chnical content, except as follows:Technical national differences are allowed for codes and governmental regulations as well as thoserecognized as being in accordance with NAFTA Article 905, for example, because of fundamental climatic,geographical, technological, or infrastructural factors, scienti
43、fic justification, or the level of protection thatthe country considers appropriate. Presentation is word for word except for editorial changes.Reasons for differences from IECThe THC determined the safe use of enclosed and dead-front switches is dependent on the design andperformance of the product
44、s in relation to the North American Electrical Codes with which they areintended to be installed.InterpretationsThe interpretation by the standards development organization of an identical or equivalent standard isbased on the literal text to determine compliance with the standard in accordance with
45、 the proceduralrules of the standards development organization. If more than one interpretation of the literal text has beenidentified, a revision is to be proposed as soon as possible to each of the standards developmentorganizations to more accurately reflect the intent.FEBRUARY 12, 2016 NMX-J-162
46、-ANCE-2016 CSA-C22.2 NO. 4-16 UL 98 51 Scope1.1 These requirements cover individually enclosed air switches, rated 4000 A or less at 600 V or less,having all current-carrying parts enclosed, manually operable by means of external handles, and intendedto be employed in accordance with the national in
47、stallation codes listed in Annex A, Ref. No. 1.1.2 As used in this Standard, the term switch is intended to mean an enclosed switch or deadfront switchunless specifically stated otherwise.1.3 These requirements also cover deadfront switches that have all current-carrying parts enclosed whenmounted i
48、n an enclosed panelboard, deadfront switchboard, or the like. These switches are manuallyoperable by means of external handles and are intended to be employed in accordance with the nationalinstallation codes listed in Annex A, Ref. No. 1.1.4 These requirements cover enclosed switches with or withou
49、t provision for fuses suitable for use asbranch circuit, feeder, and service overcurrent protection.1.5 The following fuses are deemed suitable for use as branch circuit, feeder, and service overcurrentprotection:a) Cartridge Fuses (Ref. Annex B, Low-Voltage Fuses Parts 1 10, 12 and 15),b) Plug Fuses (Ref. Annex B, Low-Voltage Fuses Parts 1 and 11), andc) Special Purposes Fuses marked as meeting the performance specifications of a specificClass Fuse.1.6 These requirements cover enclosed switche