ANSI EIA-468-C-2008 LEAD TAPING OF COMPONENTS IN THE RADIAL CONFIGURATION FOR AUTOMATIC HANDLING《自动处理用径向结构元件的引线用带系扎》.pdf

上传人:orderah291 文档编号:434651 上传时间:2018-11-11 格式:PDF 页数:18 大小:1.21MB
下载 相关 举报
ANSI EIA-468-C-2008 LEAD TAPING OF COMPONENTS IN THE RADIAL CONFIGURATION FOR AUTOMATIC HANDLING《自动处理用径向结构元件的引线用带系扎》.pdf_第1页
第1页 / 共18页
ANSI EIA-468-C-2008 LEAD TAPING OF COMPONENTS IN THE RADIAL CONFIGURATION FOR AUTOMATIC HANDLING《自动处理用径向结构元件的引线用带系扎》.pdf_第2页
第2页 / 共18页
ANSI EIA-468-C-2008 LEAD TAPING OF COMPONENTS IN THE RADIAL CONFIGURATION FOR AUTOMATIC HANDLING《自动处理用径向结构元件的引线用带系扎》.pdf_第3页
第3页 / 共18页
ANSI EIA-468-C-2008 LEAD TAPING OF COMPONENTS IN THE RADIAL CONFIGURATION FOR AUTOMATIC HANDLING《自动处理用径向结构元件的引线用带系扎》.pdf_第4页
第4页 / 共18页
ANSI EIA-468-C-2008 LEAD TAPING OF COMPONENTS IN THE RADIAL CONFIGURATION FOR AUTOMATIC HANDLING《自动处理用径向结构元件的引线用带系扎》.pdf_第5页
第5页 / 共18页
点击查看更多>>
资源描述

1、 EIA STANDARD LEAD TAPING OF COMPONENTS IN THE RADIAL CONFIGURATION FOR AUTOMATIC HANDLING (Revision of EIA-468-B) EIA-468-CDECEMBER 2008 ANSI/EIA-468-C-2008 Approved: December 30, 2008 EIA-468-C EIA Standards Electronic Components Association NOTICE EIA Engineering Standards and Publications are de

2、signed to serve the public interest through eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for his particular need. Existence

3、 of such Standards and Publications shall not in any respect preclude any member or nonmember of EIA from manufacturing or selling products not conforming to such Standards and Publications, nor shall the existence of such Standards and Publications preclude their voluntary use by those other than E

4、IA members, whether the standard is to be used either domestically or internationally. Standards and Publications are adopted by EIA in accordance with the American National Standards Institute (ANSI) patent policy. By such action, EIA does not assume any liability to any patent owner, nor does it a

5、ssume any obligation whatever to parties adopting the Standard or Publication. This EIA Standard is considered to have International Standardization implication, but the International Electrotechnical Commission activity has not progressed to the point where a valid comparison between the EIA Standa

6、rd and the IEC document can be made. This Standard does not purport to address all safety problems associated with its use or all applicable regulatory requirements. It is the responsibility of the user of this Standard to establish appropriate safety and health practices and to determine the applic

7、ability of regulatory limitations before its use. (From Standards Proposal No. 5132 formulated under the cognizance of the Automated Component Handling Committee ACH). Published by: ELECTRONIC COMPONENTS ASSOCIATION 2008 EIA Standards and Technology Department 2500 Wilson Boulevard Suite 310 Arlingt

8、on, VA 22201 PRICE: Please call: Global Engineering Documents, USA and Canada (1-800-854-7179) http:/ All rights reserved Printed in U.S.A. PLEASE ! DONT VIOLATE THE LAW! This document is copyrighted by the EIA and may not be reproduced without permission. Organizations may obtain permission to repr

9、oduce a limited number of copies through entering into a license agreement. For information, contact: Global Engineering Documents 15 Inverness Way East Englewood, CO 80112-5704 or call USA and Canada (1-800-854-7179), International (303-397-7956) EIA-468-C 1 Lead Taping of Components in the Radial

10、Configuration for Automatic Handling CONTENTS SECTIONS PAGE 1. INTRODUCTION AND SCOPE 2 2. NORMATIVE REFERENCES 2 3. DIMENSIONS 2 4. REQUIREMENTS 6 5. ACKNOWLEDGEMENTS 10 FIGURES AND TABLES FIGURE 1 Coordinate System 2 FIGURE 2 Lead Taping Dimensions 3 FIGURE 3 Component Pitch 5 FIGURE 4 Reference P

11、lane 6 FIGURE 5 Reel Configuration 8 FIGURE 6 Fan Fold Box Configuration 8 FIGURE 7 Reel Label Location 9 FIGURE 8 Fan Fold Box Label and Marking Locations 9 TABLE 1 Lead Taping Dimensions 4 TABLE 2 Component Pitch 5 TABLE 3 Reel Dimensions 8 TABLE 4 Fan Fold Box Dimensions 8 EIA-468-C 2 LEAD TAPING

12、 OF COMPONENTS IN THE RADIAL CONFIGURATION FOR AUTOMATIC HANDLING Revision of EIA Standard 468-B, formulated under the cognizance of the EIA Automated Component Handling (ACH) Committee 1. INTRODUCTION AND SCOPE This standard was formulated to provide dimensions and tolerances necessary to lead tape

13、 components in the radial format (unidirectional leads) such that they may be automatically handled. Automatic handling includes insertion, preforming and other operations. The emphasis of this standard is on the requirements for high-speed automatic insertion. This standard covers the lead taping r

14、equirements for components having two or more radial configured leads, provided these components may be taped in accordance with the requirements of this document. 2. NORMATIVE REFERENCES The following standards contain provisions which, through reference in this Standard, constitute provisions of t

15、his Standard. All normative documents are subject to revision. 2.1 ANSI/ESD S541-2003 “Packaging Materials for ESD Sensitive Items“ 2.2 ANSI/ESD S20.20-2007 “Protection of Electrical and Electronic Parts, Assemblies and Equipment” 2.3 IPC/JEDEC J-STD-020C “Moisture/Reflow Sensitivity Classification

16、for Nonhermetic Solid State Surface Mount Devices” 2.4 IPC J-STD-033B “Handling, Packing, Shipping and Use of Moisture/Reflow Sensitive Surface Mount Devices” 2.5 BS EN ISO 14001:2004 Environmental Management 3. DIMENSIONS 3.1 The coordinate system common to tapes and taped components with radial co

17、nfigured leads shall be used. The abscissa is a straight line through the centers of the sprocket holes. The ordinate is a line perpendicular to the abscissa through the center of the sprocket hole that follows the component to be checked. All dimensions referencing the component leads are to the ce

18、nterline of the lead. EIA-468-C 3 Figure 2: Lead Taping Dimensions EIA-468-C 4 Table 1: Lead Taping Dimensions (See Figures 2 and 3) SYMBOL DESCRIPTION DIMENSIONS (mm) REFERENCE A Component Body Height 23 maximum Requirement 4.3 D0Sprocket Hole Diameter 4.00.2 d0Lead diameter 0.36 minimum 0.86 maxim

19、um Requirements 4.4 and 4.5 d1Lead width (non-circular leads) 0.35 minimum 0.75 maximum Requirement 4.5 d2Lead thickness (non-circular leads) 0.35 minimum 0.75 maximum Requirement 4.5 d3Lead diagonal (non-circular leads) 0.85 maximum Requirement 4.5 F 2 Leaded Component Lead Spacing See Table 2, +0.

20、6, -0.2 F1, F23 Leaded Component Lead Spacing 2.50 +0.4, -0.1 or 2.54 +0.4, -0.1 Requirement 4.6 F= 2.5 1.65 minimum F= 5.0 4.19 minimum F3Minimum inner spacing between leads F= 7.5 6.73 minimum F= 2.5 3.68 maximum F= 5.0 6.22 maximum F4Maximum outer spacing of leads F= 7.5 8.76 maximum H Height to

21、Seating Plane (Straight Leads) 18-20 Requirement 4.8 H0Height to Seating Plane (Formed Leads) 16.00.5 Requirement 4.7 H1Overall Height Above Abscissa 38.5 maximum Requirement 4.3 h Front-to-Back Deviation 1.0 maximum Requirement 4.9 L Cut Out Length 11 maximum L1Lead Protrusion 1.0 maximum P Compone

22、nt Pitch (Nominal Dimension) See Table 2 P0Sprocket Hole Pitch 12.70.3 or 15.00.3 Requirement 4.10 P1Ordinate to Adjacent Component Lead See Table 2, 0.7 Requirement 4.6 and Figure 3 P0= 12.7 6.350.7 P2Ordinate to Component Center Lead (3 Leaded Components) P0= 15.0 7.50.7 Fig. 3, Table 2 and Requir

23、ement 4.6 P3Lead Deviation in Carrier Tape 1.0 maximum Requirement 4.21 p Side-to-Side Deviation 1.3 maximum Requirement 4.9 t Composite Tape Thickness 0.9 maximum Requirement 4.11 t1Overall Tape and Lead Thickness 2.0 maximum Requirement 4.11 W Carrier Tape Width 18 +1, -0.5 Requirements 4.12 and 4

24、.13 W0Hold Down Tape Width 5 minimum Requirements 4.12 and 4.13 W1Sprocket Hole Position 9 +0.75, -0.5 W2Adhesive Tape Position 3 maximum Requirement 4.12 EIA-468-C 5 3.2 Component Pitch: The component pitch P depends on the pitch of the sprocket holes P0and the size of the component body, B. The po

25、sitioning of the components shall be symmetrical in relation to the sprocket holes on the tape. Table 2: Component Pitch Nominal Dimensions (See Table 1) HOLE PITCH P0COMPONENT PITCH P FIG. LEAD SPACING F (Multiples of 2.5mm) P1LEAD SPACING F (Multiples of 2.54mm) P112.7 12.7 3A 1.50* 5.60 12.7 12.7

26、 3A 2.00* 5.3512.7 12.7 3A 2.50 5.10 2.54 5.08 12.7 12.7 3A 5.00 3.85 5.08 3.8112.7 12.7 3A 7.50 2.60 7.62 2.54 12.7 12.7 3B 7.50 8.95 7.62 8.8912.7 12.7 3B 10.00* 7.70 10.16* 7.62 12.7 25.4 3B 12.50* 6.45 12.70* 6.3512.7 25.4 3B 15.00* 5.20 15.24* 5.08 12.7 25.4 3B 17.50* 3.95 17.78* 3.8112.7 25.4

27、3C 20.00* 9.05 20.32* 8.89 12.7 25.4 3C 22.50* 7.80 22.86* 7.6215.0 15.0 3A 5.00 5.00 5.08 4.96 15.0 15.0 3A 7.50 3.75 7.62 3.6915.0 15.0 3B 7.50 11.25 7.62 11.19 15.0 15.0 3B 10.00* 10.00 10.16* 9.9215.0 15.0 3B 12.50* 8.75 12.70* 8.65 15.0 15.0 3B 15.00* 7.50 15.24* 7.3815.0 30.0 3B 17.50* 6.25 17

28、.78* 6.11 15.0 30.0 3B 20.00* 5.00 20.32* 4.8415.0 30.0 3B 22.50* 3.75 22.86* 3.57 3.2.1 Lead spacings marked with an asterisk (*) are commonly available but may not be compatible with high-speed automatic insertion machines. 3.2.2 Care shall be taken that the leads do not interfere with the sprocke

29、t holes. 3.2.3 The maximum body size dimension B shall be less than the nominal component pitch P. The component pitch may be increased by P0when necessary to provide clearance between components. 3.2.4 Dimension F multiples of 2.54mm represent multiples of 0.100”. For new designs, multiples of 2.5

30、are recommended. EIA-468-C 6 4. REQUIREMENTS 4.1 Procurement documents and quotation requests should include the following information: (a) Reference to this Standard by title and number. (b) Container type. (c) Component orientation (Requirement 3.x) (d) Dimension H, for straight-leaded components

31、(Requirement 3.x) (e) Lead spacing and component pitch per Table x. (f) Shipping conditions, storage conditions, and storage time. (g) Container and/or reel marking requirements (including bar coding, if required). 4.2 The leads of the taped component shall be free of kinks or bends from the seating

32、 plane or reference plane downward to the carrier tape. 4.3 Taped components with dimensions exceeding A maximum and H1maximum are commonly available but may not be compatible with high-speed automatic insertion machines. 4.4 Lead diameters outside the range of d0in Table 1 are commonly available bu

33、t may not be compatible with high-speed automatic insertion machines. 4.5 Leads with cross-sections other than circular may be used. A circle with diameter d3going through the corners of the non-circular cross-section is considered to be the equivalent circular cross-section. 4.6 Dimensions F, F1, F

34、2, F3, F4, P1and P2, are measured at the egress from the carrier tape, on the component side. 4.7 The method for determining the seating plane is as follows: 4.7.1 For components with straight leads, the seating plane is determined by the bottom of the component body, which includes the meniscus or

35、any projections which support the component on the printed circuit board. The seating plane is a line parallel to the abscissa through the bottom of the component body nearest the tape (see Figure 2, Dimension H). 4.7.2 For components with crimped (or otherwise preformed) leads, the seating plane de

36、pends on the profile of the crimp, the diameter of the leads and the hole size in the printed circuit board. For this reason, a reference plane is defined, for components with crimped leads only, as follows: The line parallel to the abscissa through the lowest center of the radius of curvature of th

37、e bending of the crimp. 4.8 Dimension H will increase as the component height, thickness, or diameter increases. H dimensions outside the range shown in Table 1 may not function properly with all taping, placement or preforming machines. 4.9 h and p are the deviation between the actual center of the

38、 component, measured at the top of the component, and the theoretical centerline determined at its emergence from the tape. h represents front-to-back deviation. p represents side-to-side deviation (see Figure 2). 4.10 Cumulative sprocket hole pitch tolerance shall not exceed 1.0mm over 20 consecuti

39、ve pitches. 4.11 Splices shall be equal in strength to the original tape (15 newtons, minimum, break force) and shall not hamper the transport or the cutting of the tape. When splicing is applied, the misalignment of the EIA-468-C 7 holes at each side of the splice shall not be more than 0.3mm in an

40、y direction. Splices shall not interfere with sprocket feed holes, nor shall the overall thickness (including lead wires) exceed dimension t1(see Table 1). Staples shall not be used. 4.12 The hold-down tape shall not protrude beyond the carrier tape. No adhesive may be exposed. Two strips of adhesiv

41、e hold-down tape may be used. 4.13 The components shall be held sufficiently in the tape so that their position remains within the permitted tolerances. The vertical extraction force for components in the tape plane shall be greater than five (5) newtons. 4.14 All polarized components shall be orien

42、ted in one direction. Unless otherwise specified, the positive lead (i.e., anode or emitter) shall be the first lead off the reel or out of the box. The side of the fanfold box shall be marked to indicate the first lead out of the box when that side of the container is opened. Examples of marking in

43、clude but are not limited to “+“ for positive lead, “-“ for negative lead, “E“ for emitter, “B“ for base, “C“ for collector, and “Pin 1” (see Figure 8). 4.15 Protection between layers of components in reels only shall be provided for the length necessary to prevent component damage or lead distortio

44、n. All materials used for lead taping, container and packaging shall not cause deterioration of the component or diminish lead solderabilitv. 4.16 The components and the outer cover on the reel shall not extend beyond the outside edge of the flange. 4.17 Empty places in the tape (i.e., missing compo

45、nents ) shall not exceed 0.1%, or one (1), whichever is greater, of the total components per container. No consecutive empty places are allowed. Empty places, such as programmed empty places at the bend of fan-fold packing, shall be by agreement between the supplier and the customer. 4.18 “Hairpin”

46、devices are axial-leaded components which have one lead bent over such that it is essentially parallel to the other lead, thus forming a radial component for taping purposes (as in Figure 2, the component marked “H”). It is recommended that these devices have standoffs or kinks formed on both leads,

47、 to provide a seating plane for the device. 4.19 For “hairpin” devices, the body shall be on the trailing side as the tape comes off the reel or out of the box. 4.20 The width of the reel or fan fold box shall allow the taped components to feed with adequate guidance and without interference. 4.21 D

48、imension P3limits outward deviation of leads in the carrier tape to prevent interference with tape cutting in high-speed automatic insertion machines. P3is measured from the lead center to the lead tip. There is no limit to inward deviation. 4.22 Devices with leads in more than one plane, as shown i

49、n Fig. 2 “Unguided Leads”, are permitted, but may not be compatible with high-speed automatic insertion machines. EIA-468-C 8 Table 3: Reel Dimensions SYMBOL DESCRIPTION DIMENSION a Reel Diameter 370 maximum c Arbor Hole Diameter 14 38 n Hub Diameter 80 minimum w1Dimension Between Flanges (measured at hub) See Requirement 4.20 w2Width, including flanges and hubs 62 maximum Table 4: Fan Fold Box Dimensions SYMBOL DESCRIPTION MAXIMUM DIMENSION x Box Width 62 (See Requirement 4.20) y Box Length 372 z Box Height 372EIA-468-C 9 EIA-468-C 10 ACKNO

展开阅读全文
相关资源
  • ANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdfANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdf
  • ANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdfANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdf
  • ANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdfANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdf
  • ANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdfANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdf
  • ANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdfANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdf
  • ANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdfANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdf
  • ANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdfANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdf
  • ANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdfANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdf
  • ANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdfANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdf
  • ANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdfANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ANSI

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1